• Title/Summary/Keyword: reverse osmosis system

Search Result 130, Processing Time 0.023 seconds

The Characteristics of Seawater RO Membrane for High Recovery System (해수담수화용 역삼투막의 고회수율 공정에서의 투과 특성)

  • 김노원
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.182-191
    • /
    • 2002
  • Polyamide reverse osmosis (RO) membrane with thin film composite structure was commercialized for seawater desalination process. Recently, it has been reported that some RO processes for high pressure and recovery leads to reducing in energy cost and pretreatment scale compared with earlier process. The development of energy recovery, pumping device and RO elements with high pressure and rejection made high pressure and recovery process possible. In this study, permeation properties of commercialized seawater RO membrane were investigated under the condition of high pressure and recovery. In the RO sheet membrane test 3.5% NaCl of synthetic seawater was used. The synthetic seawater contained only sodium chloride. In the RO module test, natural seawater was used at Happo Bay, Masan city. As the results, RO membrane with high durability of pressure was better than that with high rejection of seawater for high pressure and recovery process. Seawater rejection of high concentrate tends to be improved by high pressure operation.

Permeation Property of Each Stage in Three Stage Reverse Osmosis System for Cold-mill Wastewater Reuse (냉연공장 폐수재이용을 위한 3단 역삼투시스템에서 각 단별 투과특성 연구)

  • 박영규
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.209-214
    • /
    • 1999
  • The purpose of this research was to investigate the permeation properties of each stage in three stage reverse osmosis system for cold-mill wastewater reuse. After construction of the three staged pilot plant which had 75% recovery and equipped with seven plate-and-frame modules, the change of each stage's penneate flow and quality were investigated in the process of membrane fouling. The order of average permeate flow was first, second, and third stage at the beginning. As the operation time passed, the permeate flow of first stage was decreased, the second stage was maintained steadily, and the third stage was increased. Accordingly, the fouling was initiated at the first stage and then progressed to the second and third stage. The first stage's permeate quality showed the best and the second and third stage was the next in that order. And the order of quality was maintained during the test periods. Therefore, the permeate quality was not affected by membrane fouling.

  • PDF

Reuse of Petroleum Refinery Wastewater Using Reverse Osmosis Membrane (역삼투막을 이용한 정유산업 폐수 재활용 연구)

  • Hwang, Jong-Sic;Sang, Byoung-In;Yoo, Je-Kang;Lee, Kyu-Hyun;Min, Byoung-Ryul;Kim, Byoung-Sik
    • Membrane Journal
    • /
    • v.4 no.4
    • /
    • pp.213-220
    • /
    • 1994
  • Reverse osmosis(R/O) pilot system, which consists of pretreatments and R/O membranes, was demonstrated to regenerate the petroleum refinery wastewater for the process feedwater supply. Despite of the unsteady quality of the wastewater effluent from the process facilities, relatively high salt rejection of 96~99% was obtained and the product water showed a feasible quality for the use of cooling tower feed water. The results of R/O membrane module cleaning with NaOH solution represented that there was some fouling effects on the membrane performance during the period of test due to the ineffective treatment processes proposed and used in this study.

  • PDF

Pre-concentration of Apple Juice with Different Reverse Osmosis Membranes (역삼투막을 이용한 사과쥬스의 예비농축)

  • Kim, Kil-Hwan;Park, Hyun-Jin;Kim, Dong-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.419-425
    • /
    • 1988
  • The clarified apple juice was pre-concentrated by reverse osmosis system as a trial for reduction of heat treating time and quality drop in concentration of the juice. The permeate fluxes through CA 865 and CA 960 membranes were higher than those of HR 95 and HR 98 membranes even at the low operating pressure. In the concentration limit depended on the membranes used, HR membranes operated at 60 bar showed $29.0^{\circ}$Brix, and the time required to reach the limit was 86 min for HR 95 and 71 min for HR 98. In cases of CA membranes run at 30 bar, the juice concentration was linearly increased without the limit, and longer time to reach the same concentration was required in comparison with HR membranes. As the juice concentration was increased, the loss of soluble solids was increased, and the average contents of soluble solids in the permeate passed through HR 95, HR 98, CA 865 and CA 960 were 1.3, 0.5, 7.5 and $2.3^{\circ}$ Brix, respectively, in the juice concentration range of 20.0 -$25.0^{\circ}$ Brix. The lower amounts of sugars, total acid and flavor volatiles were involved in the permeate through HR membranes, especially HR 98 than in the permeate through CA membranes.

  • PDF

Study on the Necessity of Energy Recovery Device in Small Scale Reverse Osmosis Desalination Plant (소규모 역삼투 담수화 시설에서 에너지 회수장치의 필요성에 대한 연구)

  • Jeon, Jongmin;Kwak, Kyungsup;Kim, Noori;Jung, Jaehak;Son, Dong-Min;Kim, Suhan
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.762-766
    • /
    • 2017
  • Energy recovery device (ERD) is used to save energy consumption in seawater reverse osmosis processes. However, small-scale ERDs (<$100m^3/d$) are hardly observed in seawater desalination market. In South Korea, most of seawater desalination plants for drinking water production are small-scaled and have been operated in island areas or on ships. Thus, the effect of ERDs for these small-scale SWRO processes should not be neglected. In this work, the small-scale SWRO processes are designed and analyzed in terms of energy consumption with/without ERD. The realistic efficiencies of high pressure pumps are considered for the energy analyses. The unit cost of electricity depending on the application place (e.g., inland and island areas, on ships) is investigated to calculate the energy cost for unit water production in various SWRO applications classified by plant capacity, application place, and the installation of ERD. As a result, the energy cost can be saved up to $1,640.4KRW/m^3$ when ERD is applied, and the saving effect increases at smaller plants on ships. In conclusion, the development of small-scale ERDs are necessary because small-scale SWRO processes are dominant in Korean seawater desalination market, and the electricity saving effect becomes higher at smaller-scaled system.

Power density and fouling propensity of pretreatments in SWRO/PRO hybrid system (전처리기술별 전력밀도 및 파울링에 관한 연구)

  • Koo, Jae-Wuk;Nam, Sookhyun;Sim, Jinwoo;Kim, Eunju;Choi, Yongjun;Hwang, Tae-Mun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.755-764
    • /
    • 2016
  • Pressure retarded osmosis (PRO) processes can be implemented on a number of water types, using different technologies and achieving various power outcomes. In this study, Sewage facility effluent was used for feed solution of PRO and synthetic NaCl water for draw solution. This study was conducted to investigate effect of water quality of pretreatment on power density and flux decline in PRO process. The results show that organic and particulate foulants have to be removed for more stable operation. Flourescence technique with EEM enables to investigate the chemical properties of aquatic organic matter by extracting spectral information. Humic/fulvic matters and soluble microbial by-products were analyzed as the most affecting factors on the PRO performance. As a result of analyzing the whole system based on the energy consumption of the unit process, specific energy consumption(SEC) of the applicable technology for PRO pre-treatment should be about $0.2kWh/m^3$ or less.

Treatment of natural rubber wastewater by membrane technologies for water reuse

  • Jiang, Shi-Kuan;Zhang, Gui-Mei;Yan, Li;Wu, Ying
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • A series of laboratory scale experiments were performed to investigate the feasibility of membrane separation technology for natural rubber (NR) wastewater treatment and reuse. Three types of spiral wound membranes were employed in the cross-flow experiments. The NR wastewater pretreated by sand filtration and cartridge filtration was forced to pass through the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membranes successively. The UF retentate, which containing abundant proteins, can be used to produce fertilizer, while the NF retentate is rich in quebrachitol and can be used to extract quebrachitol. The permeate produced by the RO module was reused in the NR processing. Furthermore, about 0.1wt% quebrachitol was extracted from the NR wastewater. Besides, the effluent quality treated by the membrane processes was much better than that of the biological treatment. Especially for total dissolved solids (TDS) and total phosphorus (T-P), the removal efficiency improved 53.11% and 49.83% respectively. In addition, the removal efficiencies of biological oxygen demand (BOD) and chemical oxygen demand (COD) exceeded 99%. The total nitrogen (T-N) and ammonia nitrogen (NH4-N) had approximately similar removal efficiency (93%). It was also found that there was a significant decrease in the T-P concentration in the effluent, the T-P was reduced from 200 mg/L to 0.34 mg/L. Generally, it was considered to be a challenging problem to solve for the biological processes. In brief, highly resource utilization and zero discharge was obtained by membrane separation system in the NR wastewater treatment.

UF pretreatment at elevated temperature within the scheme of hybrid desalination: Performance and environmental impact

  • Agashichev, Sergey;Kumar, Jayesh
    • Membrane and Water Treatment
    • /
    • v.8 no.3
    • /
    • pp.279-292
    • /
    • 2017
  • This study was aimed at ultrafiltration (UF) as a pretreatment before reverse osmosis (RO) within the scheme of hybrid reverse osmosis-multistage flush (RO-MSF) desalination. Seawater at elevated temperature (after MSF heat-exchangers) was used as a feed in this process. The pretreatment system was represented as a set of functionally-linked technological segments such as: UF filtration, backwashing, chemical- enhanced backwashing, cleaning, waste disposal, etc. The process represents the sequences of operating cycles. The cycle, in turn, consists of the following unit operations: filtration, backwashing and chemical-enhanced backwashing (CEB). Quantitative assessment was based on the following indicators: normalized permeability, transmembrane pressure, specific energy and water consumption, specific waste generation. UF pre-treatment is accompanied by the following waste streams: $W1=1.19{\times}10$ power of $-2m^3$ (disposed NaOCl with 0.0044% wt.)/$m^3$ (filtrate); $W2=5.95{\times}10$ power of $-3m^3$ (disposed $H_2SO_4$ with 0.052% wt.)/$m^3$(filtrate); $W3=7.26{\times}10$ power of $-2m^3$ (disposed sea water)/$m^3$ (filtrate). Specific energy consumption is $1.11{\times}10$ power of $-1kWh/m^3$ (filtrate). The indicators evaluated over the cycles with conventional (non-chemical) backwashing were compared with the cycles accompanied by CEB. A positive impact of CEB on performance indicators was demonstrated namely: normalized UF resistance remains unchanged within the regime accompanied by CEB, whereas the lack of CEB results in 30% of its growth. Those quantitative indicators can be incorporated into the target function for solving different optimization problems. They can be used in the software for optimisation of operating regimes or in the synthesis of optimal flow- diagram. The cycle characteristics, process parameters and water quality data are attached.

Bio-regeneration of Ion-exchange Resin for Treating Reverse Osmosis Concentrate (RO 농축폐액의 처리를 위한 이온교환수지의 생물재생)

  • Bae, Byung-Uk;Nam, Youn-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.517-523
    • /
    • 2014
  • In order to remove both nitrate and sulfate present in the concentrate of RO(reverse osmosis) process, a combined bio-regeneration and ion-exchange(IX) system was studied. For this purpose, both denitrifying bacteria(DNB) and sulfate reducing bacteria(SRB) were simultaneously cultivated in a bio-reactor under anaerobic conditions. When the IX column containing a nitrate-selective A520E resin was fully exhausted by nitrate and sulfate, the IX column was bio-regenerated by pumping the supernatant of the bio-reactor, which contains MLSS concentration of $125{\pm}25mg/L$, at the flowrate of 360 BV/hr. Even though the nitrate-selective A520E resin was used, the breakthrough curves of ionic species showed that sulfate was exhausted earlier than nitrate. The reason for this result is due to the fact that the concentration of sulfate in RO concentrate was 36 to 48 times higher than nitrate. The bio-reactor was successfully operated at a volumetric loading rate of 0.6 g $COD/l{\cdot}d$, nitrate-N loading rate of 0.13 g $NO_3{^-}-N/l{\cdot}d$, and sulfate loading rate of 0.08 g $SO_4{^{2-}}/l{\cdot}d$. The removal rate of SCOD, nitrate-N, sulfate was 90, 100, and 85%, respectively. When the virgin resin was fully exhausted and consecutively bio-regenerated for 2 days, 81% of nitrate and 93% of sulfate were reduced. When the virgin resin was repeatedly used up to 4 cycles of service and bio-regeneration, the ion-exchange capacity of bio-regenerated resin decreased to 95, 91, 88, and 81% of virgin resin.

A Study on Condition-based Maintenance Policy using Minimum-Repair Block Replacement (최소수리 블록교체 모형을 활용한 상태기반 보전 정책 연구)

  • Lim, Jun Hyoung;Won, Dong-Yeon;Sim, Hyun Su;Park, Cheol Hong;Koh, Kwan-Ju;Kang, Jun-Gyu;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.18 no.2
    • /
    • pp.114-121
    • /
    • 2018
  • Purpose: This study proposes a process for evaluating the preventive maintenance policy for a system with degradation characteristics and for calculating the appropriate preventive maintenance cycle using time- and condition-based maintenance. Methods: First, the collected data is divided into the maintenance history lifetime and degradation lifetime, and analysis datasets are extracted through preprocessing. Particle filter algorithm is used to estimate the degradation lifetime from analysis datasets and prior information is obtained using LSE. The suitability and cost of the existing preventive maintenance policy are each evaluated based on the degradation lifetime and by using a minimum repair block replacement model of time-based maintenance. Results: The process is applied to the degradation of the reverse osmosis (RO) membrane in a seawater reverse osmosis (SWRO) plant to evaluate the existing preventive maintenance policy. Conclusion: This method can be used for facilities or systems that undergo degradation, which can be evaluated in terms of cost and time. The method is expected to be used in decision-making for devising the optimal preventive maintenance policy.