정수기 공급수인 수돗물과 정수기 통과수의 수질차이 분석 (Water quality analyses between tap water and treated water by point-of-use water dispenser systems)

  • 박근영;박지원;김재혁;나영;맹승규;김성표;권지향
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.395-404
    • /
    • 2019
  • The point-of-use water dispenser systems are widely used because of convenience in handling and demand for high-quality drinking water. The application has been increased recently in the public places such as department stores, universities and the rest areas in express ways. Improvement of water qualities by the dispenser systems was compared with tap water in this study. The tap water is supplied to the dispenser as the influent of the dispenser system. The twelve dispensers in the public places were used. The five dispensers used reverse osmosis as the main filter and other dispensers used various filters such as ultrafiltration, nanofiltration, and alumina filter. The water quality indicators for sanitation safety, i.e., turbidity and total coliforms, were evaluated. Other water qualities such as pH, residual chlorine, heterotrophic plate count (HPC), and total cell counts were also analyzed. By the point-of-use water dispenser, the turbidity, residual chlorine and pH were decreased and the HPC and total cell counts were increased. The t-test results revealed that the HPC of the tap waters were not significantly different from the treated waters but the total cell counts of the two groups were significantly different. The low pH of the RO filter treatment was also significantly different from the tap waters. This study will contribute to understand the role of the point-of-use water dispenser in improving water quality and to identify key water quality for the proper maintenance of the dispenser systems.

유기물 농도가 낮은 고품질 정수 생산을 위한 고압막여과 공정 설계 시 고려사항 (Considerations to design high-pressure membrane system to produce high quality potable water with lower organic matter concentration)

  • 전종민;김성수;서인석;김수한
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.473-480
    • /
    • 2020
  • High-pressure membrane system like nanofiltration(NF) and reverse osmosis(RO) was investigated as a part of water treatment processes to produce high quality potable water with low organic matter concentration through membrane module tests and design simulation. River water and sand filtration permeate in Busan D water treatment plant were selected as feed water, and NE4040-90 and RE4040-Fen(Toray Chemical Korea) were used as NF and RO membranes, respectively. Total organic carbon(TOC) concentrations of NF and RO permeates were mostly below 0.5 mg/l and the average TOC removal rates of NF and RO membranes were 93.99% and 94.28%, respectively, which means NF used in this study is competitive with RO in terms of organic matter removal ability. Different from ions rejection tendency, the TOC removal rate increases at higher recovery rates, which is because the portion of higher molecular weight materials in the concentrated raw water with increasing recovery rate increases. Discharge of NF/RO concentrates to rivers may not be acceptable because the increased TDS concentration of the concentrates can harm the river eco-system. Thus, the idea of using NF/RO concentrate as the raw water for industrial water production was introduced. The design simulation results with feed water and membranes used in this work reveal that the raw water guideline can be satisfied if the recovery rate of NF/RO system is designed below 80%.

정밀여과와 역삼투를 이용한 방류수 재이용 시스템 개발 (Development of Wastewater Reclamation System With Use of Microfilter and Reverse Osmosis)

  • 강신경
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 춘계 총회 및 학술발표회
    • /
    • pp.119-122
    • /
    • 2004
  • 최근 들어 용수가격 상승과 갈수기 대비 대체용수 확보차원에서 폐수를 처리하여 공업용수를 재이용하는 사례가 증가하고 있다. 국내의 경우 단위 사업장에서 폐수재이용 시설을 설치한 사례는 비교적 많은 편이나, 정상적으로 가동하는 경우는 드문 것으로 조사되고 있다[1]. 이는 초기 시설 투자비를 줄이기 위하여 전처리를 소홀히 한 것이 가장 큰 원인으로 판단된다.(중략)

  • PDF

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF

Hybrid neutralization and membrane process for fluoride removal from an industrial effluent

  • Meftah, Nouha;Ezzeddine, Abdessalem;Bedoui, Ahmed;Hannachi, Ahmed
    • Membrane and Water Treatment
    • /
    • 제11권4호
    • /
    • pp.303-312
    • /
    • 2020
  • This study aims to investigate at a laboratory scale fluorides removal from an industrial wastewater having excessive F- concentration through a hybrid process combining neutralization and membrane separation. For the membrane separation operation, both Reverse Osmosis (RO) and Nanofiltration (NF) were investigated and confronted. The optimized neutralization step with hydrated lime allowed reaching fluoride removal rates of 99.1± 0.4 %. To simulate continuous process, consecutive batch treatments with full recirculation of membrane process brines were conducted. Despite the relatively high super saturations with respect to CaF2, no membrane cloaking was observed. The RO polishing treatment allowed decreasing the permeate fluoride concentration to 0.9± 0.3 mg/L with a fluoride rejection rate of 93± 2% at the optimal transmembrane pressure of around 100 psi. When NF membrane was used to treat neutralization filtrate, the permeate fluoride concentration dropped to 1.1± 0.4 mg/L with a fluoride rejection rate of 88± 5% at the optimal pressure of around 80 psi. Thus, with respect to RO, NF allowed roughly 20% decrease of the driving pressure at the expense of only 5% drop of rejection rate. Both NF and RO permeates at optimal operating transmembrane pressures respect environmental regulations for reject streams discharge into the environment.

해양심층수담수화를 위한 유무기계 분리막 개발(1) (Development of Hybrid Membrane composed of Organic and Inorganic Polymers for the Desalination of Deep Ocean Water (I))

  • 김현주;정동호;홍영기;송경헌
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.7-12
    • /
    • 2004
  • Desalination system of revers osmosis(RO) membrane has been proven to be the most economical not only for the desalination of water containing salts, but also for the concentration of solute. RO membranes were traditionally made of inorganic polymers such. as cellulose acetate(CA), Polyamide(PA). To retain more minerals in deep ocean water, a new hybrid membrane composed of tourmaline film as organic material onto inorganic layer of CA polymer in asymmetric structure was developed for RO membrane process. The performance tests were carried out in the permeability of pure water and the rejection of NaCl solution to evaluate the adaptability for DOW desalination. The results of these basic tests show possibility to apply the new hybrid RO membrane for the desalination with function control.

  • PDF

압력지연삼투(PRO) 공정에서 막 모듈 배치와 유입원수의 유입 흐름방식이 성능에 미치는 영향 (Effect of Membrane Module and Feed Flow Configuration on Performance in Pressure Retarded Osmosis)

  • 고길현;김동현;박태신;강임석
    • 상하수도학회지
    • /
    • 제30권3호
    • /
    • pp.271-278
    • /
    • 2016
  • Recently, reverse osmosis (RO) is the most common process for seawater desalination. A common problem in both RO and thermal processes is the high energy requirements for seawater desalination. The one energy saving method when utilizing the osmotic power is utilizing pressure retarded osmosis (PRO) process. The PRO process can be used to operate hydro turbines for electrical power production or can be used directly to supplement the energy required for RO desalination system. This study was carried out to evaluate the performance of both single-stage PRO process and two-stage PRO process using RO concentrate for a draw solution and RO permeate for a feed solution. The major results, were found that increase of the draw and feed solution flowrate lead to increase of the production of power density and water permeate. Also, comparison between CDCF and CDDF configuration showed that the CDDF was better than CDCF for stable operation of PRO process. In addition, power density of two-stage PRO was lower than the one of single-stage. However, net power of two-stage PRO was higher than the one of single-stage PRO.

RO/NF/ED 연계 공정에 의한 고경도 담수 제조 (The Hardness Water Production By RO/NF/ED Linking Process From Deep Seawater)

  • 문덕수;김광수;지호;최미연;정현지;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제16권4호
    • /
    • pp.227-238
    • /
    • 2013
  • 본 연구의 목적은 해수담수화 과정 중 황산이온과 염소이온은 제거하고 유용미네랄인 마그네슘, 칼슘은 잔존 시키는 미네랄 수질 조정 기술로 먹는물 수질기준에 맞는 고경수 제조 공정 개발에 있다. 역삼투막(RO)에 통과시켜 농축수(Concentrated deep seawater)와 탈염수(desalted deep seawater)를 제조하고, 나노여과막(NF)를 사용하여 염화나트륨이 제거되지 않은 1차 미네랄 농축수(Mineral enriched deep seawater)를 제조하여, 전기투석 이온교환막(ED)을 가동하여 염화나트륨을 제거한 탈염 미네랄농축수(Mineral enriched desalted water)를 제조하여 이를 RO 탈염수와 희석하여 고경도 먹는해양심층수를 제조하였다. 역삼투막은 해수(해양심층수) 원수에서 용존물질과 담수를 분리할 수 있으며, 2차에 걸쳐 역삼투막을 사용하면, 용존성분 중 99.9% 이상 제거되고, 경도 1이하, 염소이온의 농도 2.3 mg/L인 용존물질이 완전히 제거된 탈염수(순수)를 제조할 수 있었다. 나노여과막 (NF 막)의 간극은 $10^{-9}$ m으로 마그네슘과 칼슘은 50%정도 통과시키며, 염소이온과 나트륨 같은 일가이온은 95%이상 통과한다. 나노여과막은 마그네슘과 칼슘과 같은 경도 성분과 나트륨과 염소이온과 같은 염분성분을 분리 농축할 수 있지만, 완벽하게 분리하지는 못한다. 전기투석막(ED)은 전기전도도에 따라 경도성분의 이가이온과 염분성분인 일가이온이 분리된다. 전기전도도 20 mS/cm 이상에서 경도성분(마그네슘이온, 칼슘 이온 등)은 제거되지 않는 반면, 염분성분 (나트륨이온, 염소이온 등)은 지속적으로 제거되었다. 따라서, 나노여과막을 이용하여 마그네슘과 칼슘과 같은 경도 성분을 농축하고, 전기투석막을 이용하여 경도농축수에서 염분성분을 분리하여 경도농도 12,600 mg/L, 염소이온 농도 2,446 mg/L의 염분성분이 배제된 고경도 농축수를 제조할 수 있었다. 이러한 고경도수를 역삼투막을 이용하여 용존물질이 모두 제거된 2차 RO 생산수로 10배 희석하면 염소이온 농도 244 mg/L 로 먹는물 수질기준에 적합하면서 경도농도 1,260 mg/L 인 고경도 수 제조도 가능하였다. RO/NF/ED 또는 NF/ED 연계공정은 해수의 증발 없이 역삼투막, 나노여과막과 전기투석막만을 이용하여 염소이온과 나트륨, 칼륨, 황산이온과 같은 염분성분을 제거하면서 마그네슘과 칼슘과 같은 경도성분은 농축할 수 있어서 먹는물 수질기준에 적합한 고경도수 제조가 가능하였으며, 이 과정 중 소모되는 에너지를 줄일 수 있었다.

RO/PRO 공정에 의한 물/에너지/상호변환기술에 관한 연구 (Study on Water / Energy / Mutual-changing Technology by RO/PRO Process)

  • 최영권;윤택근;손진식;이상호;최준석
    • 한국유체기계학회 논문집
    • /
    • 제16권1호
    • /
    • pp.61-65
    • /
    • 2013
  • Water is an integral part of energy production because it is used directly in many power generation systems such as hydroelectric power plants and thermoelectric power plants. Water is also used extensively in energy-resource extraction, oil, natural gas, and alternative fuels refining and processing. Recently, osmotic power systems using seawater and freshwater has been also investigated to produce electricity in a sustainable way. This study focused on the use of RO and PRO for the mutual conversion of water and energy. This system allows the production of water from seawater if there is not enough water. It can also generate electricity from salinity gradient of brine water and fresh water if there is not enough energy. To demonstrate the feasibility of this technology, a set of laboratory-scale experiments were carried out using a specially-designed RO/PRO system. The efficiency of energy conversion was theoretically estimated based on the results from the experiments. The results indicated that water and energy could be easily converted using a single device. Nevertheless, a lack of optimum membrane for this purpose was identified as a major barrier for practical application.

SWRO 플랜트의 RAM 분석을 위한 시뮬레이션 모델 연구 (A Study on Simulation Model for RAM Analysis of SWRO Plant)

  • 김용수;박정원;최석호;강준규
    • 한국시뮬레이션학회논문지
    • /
    • 제28권4호
    • /
    • pp.1-10
    • /
    • 2019
  • 해수담수화(SWRO, Sea Water Reverse Osmosis) 플랜트는 장기적이고 지속적인 담수 생산을 위하여 설계단계부터 플랜트의 가용도를 고려하여야 하며, 시간의 흐름에 따라 다양한 형태의 노후 현상이 진행되어 시스템 성능의 저하가 발생하므로 가용도 유지를 위한 고장정비 및 예방정비 계획 수립 등이 필요하다. 해수담수화 플랜트와 같이 복잡한 공학구조로 구성된 플랜트 분야에서는 시스템의 신뢰도 혹은 가용도를 수리적인 방법으로 추정하는데 어려움이 있다. 본 연구는 해수담수화 플랜트에 특화된 소프트웨어 개발을 위하여, RAM 분석 프레임워크와 모델링 방법을 개발하고, 가용도 산출을 위한 이산사건 시뮬레이션 모델을 제안한다. 플랜트 정비의 특성을 고려하여 고장 정비 발생 시, 단일 부품의 수리/교체 뿐만 아니라 분해 정비 수준에 따라 접근 가능한 모든 부품을 동시 정비하는 예방정비 정책을 제안하고, 제안된 방법론에 따라 시뮬레이션 모델 및 프로토타입을 개발하였다. 이를 활용하여 국내외에 건설된 해수담수화 플랜트의 현장 데이터를 기반으로 시스템의 가용도 및 가동률 등을 추정 사례 연구를 수행하였고, 그 결과 실제 플랜트의 가용도와 근접한 결과를 얻었다.