• Title/Summary/Keyword: reverse osmosis (RO)

Search Result 230, Processing Time 0.024 seconds

Evaluation of Water Quality using ICR Mouse 1-cell Embryo (ICR계 생쥐 1세포배를 이용한 수질의 평가)

  • Kim, Chung-Hyon;Cheong, Kyung-Soon;Park, So-Hyun;Hwang, Do-Yeong;Kim, Ki-Chul;Min, Eung-Gi
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.63-68
    • /
    • 1994
  • To confirm the overcome of in vitro 2-cell block, ICR mouse I-cell embryos were cultured in CZB media. All embryos in CZB were overcome in vitro 2-cell block and 92% of embryos were developed to the blastocyst at day 4. However, in m-KRB group(control) only 20% of embryos were developed over 2-cell. Any embryos in m-KRB did not develop to the morular stage. Developments and degenerations of ICR mouse I-cell embryos were compared in CZB medium prepared with water of three quality:(l) Milli-Q ultrafiltration water(UF);(2) Milli-Q reverse osmosis water(RO);(3) tap water(TAP). The objective was to evaluate the potential of quality control using ICR mouse 1-cell embryos. The more water was purified, the better embryo developments were supported and the less embryos were degenerated. As a quality control system, the culture of ICR 1-cell mouse embryos in CZB was useful.

  • PDF

Measurements and methods for analyzing zeta potential of the external surface of hollow fiber membranes (중공사막 외부표면의 제타전위 측정방법 고찰)

  • Lee, Taeseop;Lee, Sangyoup;Lee, Joohee;Hong, Seungkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.353-362
    • /
    • 2009
  • A new method and equipment for measuring the zeta potential of the external surface of hollow fiber (HF) membranes is reported. An existing commercial streaming potential analyzer in conjunction with home-made test cells was used to determine the electrokinetic surface characteristics of various HF membranes. It was shown that measurements of the external surface of HF membrane using the home-made test cells designed in this study were easy and reliable. The zeta potential values were quite accurate and reproducible. By varying the physical shape of the test cells to adjust hydrodynamics inside the test cells, several upgrade versions of home-made test cells were obtained. It was shown that the zeta potential of the external surface of HF membranes was most influenced by membrane materials as well as the way of surface modification. However, the overall surface charge of tested HF membranes were much less than that of commercial polyamide thin-film-composite (TFC) reverse osmosis (RO) membranes due to the lack of surface functional groups. For the HF membranes with the same material, the effect of pore size on the zeta potential was not significant, implying the potential of accurate zeta potential measurements for various HF membranes. The results obtained in this study are expected to be useful for better understating of electrokinetic surface characteristics of the external surface of HF membranes.

Study of MF membrane as pretreatment option using various backwash process from wastewater reuse pilot plant (전처리 MF의 다양한 역세 공정을 적용한 하수재이용 파일럿 플랜트 연구)

  • Park, Kwang-Duck;Park, Chansoo;Lee, Chang-Kyu;Kim, Jong-Oh;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.335-341
    • /
    • 2016
  • Various studies have forwarded an outstanding wastewater effluent treatment systems toward securing sustainable supply of water sources. In this paper, a broad overview of the performance of MF membrane as pretreatment option for wastewater reuse will be presented based on the literature survey and experiments conducted over the wastewater reuse pilot plant. The pilot plant was operated with a continuous data acquisition for about 300days under various chemical enhanced backwash (CEB) system with subsequent treated water quality analysis. Accordingly, assessment of the effluent revealed that the pretreated water is suitable enough to be used as an input for Reverse Osmosis (RO) unit and significant effect of CEB and concentration of NaOCl is also conceived from the analysis. Moreover, it's also observed that the application of various CEB condition over long operational hours induced a constant declination of overall performance of MF membrane.

Oxidation of Endocrine Disrupting Chemicals Using Sodium Persulfate (과황산나트륨을 이용한 내분비계장애물질 산화제거)

  • Lim, Chan Soo;Yun, Yeo Bog;Kim, Do Gun;Ko, Seok Oh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.609-617
    • /
    • 2013
  • The objective of this study was to evaluate the oxidation method to remove endocrine disrupting chemicals in reverse osmosis(RO) retentate for the reuse of wastewater effluent. Oxidation of organic pollutants was induced by the persulfate catalyzed by Fe(II). Affecting factors such as initial pH and ionic strength on the Fe(II) catalyzed persulfate oxidation were evaluated. $17{\alpha}$-ethynylestradiol (EE2) degradation efficiency decreased as pH and ionic strength increased. However, the efficiency increased as chloride ion concentration increased due to the influence of radical transfer.

The review of optimal location for enhanced energy efficiency in seawater desalination plant (해수담수화 시설의 에너지 효율 향상을 위한 최적위치 검토)

  • Shim, Kyu Dae;Jang, Boo Keun;Park, Yong Gyun;Choung, Joon Yeon;Kim, Dong Kyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.201-201
    • /
    • 2019
  • 세계적인 기상이변으로 가뭄발생 빈도 및 영향이 증가하고 있으며, 급속한 산업화로 사용 가능한 수자원이 점차 고갈되어 있어, 국내에서도 해수담수화(Seawater Desalination)는 새로운 대체수자원으로 많은 관심을 받고 있다. 해수담수에 필요한 에너지 약 50~70%는 역삼투(Reverse Osmosis) 공정에서 발생되며, 해수온도 및 염분도에 따라 많이 변동될 수 있으므로 국립해양조사원(KHOA)의 과거 20년 자료를 이용하여 해수담수화 시설물 위치에 따른 영향을 분석하였다. 해수담수화에 필요한 에너지는 막 제조사에서 제공하는 RO Projection Software를 적용하여 에너지 소모량을 평가하고, 이를 고려한 시설물 위치에 대한 평가 모델을 구축하였다. 기존 해수담수화 시설은 대규모 물 공급이 필요한 지역을 우선적으로 고려했기 때문에 시설물 위치에 대한 객관적인 평가기준 마련이 어려웠다. 그러나 해수담수화 플랜트는 한번 설치되면 장기적인 시설물 유지 및 관리가 필요함으로 경제성을 고려한 최적 입지의 선정은 매우 중요하다. 본 연구는 국립해양조사원의 수집된 자료를 바탕으로 해수담수화 시설물 입지선정을 정량적으로 평가함으로서, 시설물 위치에 대한 의사결정시 참고할 수 있는 기초자료로 활용될 것으로 기대한다.

  • PDF

Fouling behaviours of two stages microalgae/membrane filtration system applied to palm oil mill effluent treatment

  • Teow, Yeit Haan;Wong, Zhong Huo;Takriff, Mohd Sobri;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • v.9 no.5
    • /
    • pp.373-383
    • /
    • 2018
  • Fouling by solids and microorganisms is the major obstacle limiting the efficient use of membrane wastewater treatment. In our previous study, two stages microalgae/membrane filtration system was proposed to treat anaerobic digested palm oil mill effluent (AnPOME). This two stages microalgae/membrane filtration system had showed great potential for the treatment of AnPOME with high removal of COD, $NH_3-N$, $PO_4{^{3-}}$, TSS, turbidity, and colour. However, fouling behavior of the membrane in this two stages microalgae/membrane filtration system was still unknown. In this study, empirical models that describe permeate flux decline for dead-end filtration (pore blocking - complete, intermediate, and standard; and cake layer formation) presented by Hermia were used to fit the experimental results in identifying the fouling mechanism under different experimental conditions. Both centrifuged and non-centrifuged samples were taken from the medium with 3 days RT intervals, from day 0 to day 12 to study their influence on fouling mechanisms described by Hermia for ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) filtration mode. Besides, a more detailed study on the use of resistance-in-series model for deadend filtration was done to investigate the fouling mechanisms involved in membrane filtration of AnPOME collected after microalgae treatment. The results showed that fouling of UF and NF membrane was mainly caused by cake layer formation and it was also supported by the analysis for resistance-in-series model. Whereas, fouling of RO membrane was dominated by concentration polarization.

Rheological Properties of Radish Juice Concentrates (무우쥬스 농축액의 Rheological Properties)

  • Lee, Se-Eun;Lee, Boo-Yong;Jin, Jae-Soon;Kim, Dong-Man;Kim, Kil-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.261-265
    • /
    • 1992
  • To improve preservation and utilization of radish juice concentrates, radish juice were concentrated by reverse osmosis(RO) and thin layer evaporator(TLE) and their rheological properties were investigated. Radish juice concentrates were considered as nowtonian fluids. The apparent viscosity of conc. 1 (Heat treatment radish juice, concentrated by TLE), conc. 2 (Raw radish juice, concentrated by TLE), conc. 3 (Heat treatment radish juice, concentrated by RO) were 0.0503, 0.0578 and 0.0655 Pa.s at 10(1/s), respectively. The yield stress of these concentrates were ranged from 0.0001 to 0.0580 Pa. The activation energy for the flow of the radish juice conc. 1 were increased from 2.7057 to $4.1159{\times}10^4KJ/kg.mol$ by increasing concentration of radish juice.

  • PDF

Optimization of energy efficiency through comparative analysis of factors affecting the operation with energy recovery devices on SWRO desalination process (역삼투막 해수담수화 공정에서 에너지 회수장치의 운영인자 비교분석을 통한 에너지 효율 최적화 연구)

  • Kim, Pooreum;Kim, Hyungsoo;Park, Junyoung;Kim, Taewoo;Kim, Minjin;Park, Kitae;Kim, Jihoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Recently, interest in the development of alternative water resources has been increasing rapidly due to environmental pollution and depletion of water resources. In particular, seawater desalination has been attracting the most attention as alternative water resources. As seawater desalination consumes a large amount of energy due to high operating pressure, many researches have been conducted to improve energy efficiency such as energy recovery device (ERD). Consequently, this study aims to compare the energy efficiency of RO process according to ERD of isobaric type which is applied in scientific control pilot plant process of each $100m^3/day$ scale based on actual RO product water. As a result, it was confirmed that efficiency, mixing rate, and permeate conductivity were different depending on the size of the apparatus even though the same principle of the ERD was applied. It is believed that this is caused by the difference in cross-sectional area of the contacted portion for pressure transfer inside the ERD. Therefore, further study is needed to confirm the optimum conditions what is applicable to the actual process considering the correlation with other factors as well as the factors obtained from the previous experiments.

Study on the Membrane Cleaning-in-place (CIP) Conditions for the Dye Wastewater Treatment Process Using Polyamide Composite Membranes (폴리아마이드계 복합막을 이용한 염료 폐수 처리 공정 분리막 세척 조건 연구)

  • JeGal, Jong-Geon;Lee, Yong-Hwan;Hwang, Jeong-Eun;Jaung, Jae-Yun
    • Membrane Journal
    • /
    • v.18 no.1
    • /
    • pp.94-102
    • /
    • 2008
  • For the treatment of the dye wastewater, a polyamide nano-composite membrane and reverse osmosis (RO) membranes were prepared using interfacial polymerization technique, in which piperazine, meta-phenylene diamine, and trimesoyl chloride were used as monomers, Their permselective properties were characterized with aqueous solutions of PEG 600, $Na_2SO_4$, and NaCl, and their performance was compared with that of Osmonics Co, They were found to be a typical nano-composite membrane and a low pressure RO membrane. Using them, a real dye wastewater supplied from the Kyungin Corporation, one of the domestic dye producer, was treated, studying the separation performances of the membranes, Also, during the wastewater treatment, cleaning in place (CIP) of the membranes was carried out regularly to recover the flux of the membranes. Three different chemical cleaners were employed for the CIP process and their performance were compared in this study.

Study on the Fouling Reduction of the RO Membrane by the Coating with an Anionic Polymer (역삼투막 표면에 음이온 고분자 코팅을 통한 파울링 현상 감소연구)

  • Cho, Eun Hye;Cheong, Seong Ihl;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.22 no.6
    • /
    • pp.481-488
    • /
    • 2012
  • The anionic exchange polymer, poly(vinyl amine)(PVAm), was coated onto polyamide (PA) reverse osmosis (RO) membranes by using 'salting-out' method. The effects of the fouling phenomena for these PVAm coated membranes were investigated using the model foulants, bovine serum albumin (BSA), humic acid (HA), and sodium alginate (SA). The surface coating and the fouling phenomena were observed by the scanning electron microscopy. And the flux was measured for each 100 ppm of above foulant aqueous solution at the operating pressure, 2, 4, 8 bar. The PVAm-coated PA membranes showed somewhat fouling improvements and the fouling reduction was shown in the order of HA > SA > BSA, particularly HA case was distinct.