• 제목/요약/키워드: reuse of the effluent

검색결과 130건 처리시간 0.022초

$\gamma$-선의 조사를 이용한 하수처리장 방류수 처리에 관한 연구 (A Study on the Treatment of Secondary Effluent by ${\gamma}-ray$ Irradiation)

  • 이면주;정영도;박순달
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.106-114
    • /
    • 1998
  • This study was carried out for the purpose of industrial reuse of effluent released from activated sludge unit by $\gamma $-ray irradiation technique. The dissolved organic carbon in the effluent of an activated sludge unit is mostly refractory or inert material which are difficult to be degraded by micro organism. The effluent generated from activated sludge unit was irradiated with Co$^{60}$ $\gamma $-ray under condition of air bubbling. The effects of irradiation on the pH, COD, TOC, color, molecular weight distribution were investigated by membrane filtration and u.v.-spectrum analysis. With increasing dose, the TOC was decreased smoothly. The COD was increased at lower dose, while the COD was decreased at higher dose. The TOC and COD, however, were decreased smoothly when TiO$_{2}$ was added to the solution. It was thought that the differential decreasing trend of COD and TOC in according to the absence or presence of TiO$_{2}$ was due to the molecular weight distribution shifted from group of higher molecular weight to group of lower one which are more easy to be decomposed. The removal efficiency of color was 71.5% and it was increased to 85.7% when TiO$_{2}$ was added to the solution. The $\gamma $-ray irradiation was effective on the production of chlorine.

  • PDF

물 부족국가에서 활용가능한 정화조의 최적모형 개발 (Development of Optimal Septic Tank in the Countries of Water Shortages)

  • 임봉수;경해룡
    • 한국물환경학회지
    • /
    • 제31권4호
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

하수처리수의 논 관개용수 재이용을 위한 미생물 위해성 평가 (Quantitative Microbial Risk Assessment of Wastewater Reuse for Irrigation in Paddy Field)

  • 윤춘경;한정윤;정광욱;장재호
    • 한국농공학회논문집
    • /
    • 제48권2호
    • /
    • pp.77-87
    • /
    • 2006
  • The reuse of wastewater for agricultural irrigation may cause human health risk as a result of exposure to pathogens. This study conducted the quantitative microbial risk assessment in paddy field irrigated with treated wastewater. Six treatments were used to irrigate the paddy field from Year 2003 to Year 2005: biofilter-effluent, UV-disinfected water (6, 16, 40, 68 $mW s cm^{-2}$), pond-treated water, wetland-treated water, conventional irrigation water and tap water. Total coliforms, fecal coliforms and E. coli were monitored during rice growing period. Beta - Poisson model was employed to calculate the microbial risk of pathogens ingestion that may occur to farmers and neighbor children. Uncertainty of risk was estimated using Monte Carlo simulation. In this study, the microbial risk was higher during initial cultivation (end of May$\sim$June), and it decreased with time. Biofilter effluent (secondary effluent) irrigation showed higher risk values than others (>$10^{-4}$) and irrigation with UV-disinfected water has the lowest risk range ($10^{-6}{\sim}10^{-5}$). The risk value estimated in 2005 was lower than risk value in 2003 and 2004, it is likely due to clean tap water irrigation in initial transplanting stage. It is suggested that irrigation with UV-disinfected water and pond-treated water would reduce the microbial risk associated with wastewater irrigation in paddy field. In addition, the first irrigation water quality significantly affected the subsequent microbial risk.

하수재이용을 위한 혐기성 유동상 생물반응기 처리수의 정삼투 여과막의 적용 (Forward Osmosis Membrane to Treat Effluent from Anaerobic Fluidized Bed Bioreactor for Wastewater Reuse Applications)

  • 권대은;김정환
    • 멤브레인
    • /
    • 제28권3호
    • /
    • pp.196-204
    • /
    • 2018
  • 하수처리 혐기성 유동상 생물반응기(Anaerobic Fluidized Bed Bioreactor : AFBR)는 높은 표면적을 갖는 입상활성탄을 유동 메디아로 적용함으로써 생물막 형성 및 유지에 유리하며 이로 인해 우수한 유기물 제거 효율을 나타내나 처리된 유출수 내의 질소와 같은 영양염류의 잔존이 여전히 문제로 남아있다. 본 연구에서는 AFBR에 의해 처리된 유출수 내의 질소 배제를 위하여 정삼투막(FO membrane)을 유도용액의 종류와 농도에 따라 적용하였다. 실험결과 유출수의 총질소 배제 효율은 FO막에 적용하는 유도용액(draw solution : DS)의 종류 및 농도에 크게 의존하였다. 유도용액 농도가 증가함에 따라 FO막의 수투과량이 증가하였으며, 1 M의 NaCl을 유도용액으로 사용한 경우 총질소 배제 효율은 55%이었으나 1 M의 glucose를 유도용액을 사용한 경우 거의 완벽한 총질소 배제 효율을 나타내었다. AFBR 유출수를 FO막으로 24시간 동안 여과를 진행하였으나 파울링에 의한 수투과량의 감소는 관찰되지 않았다.

물리, 화학 및 생물학적 방법에 의한 안료폐수의 적정처리 및 재이용 가능성 평가 (The Appropriate Treatment and Reuse Ability Assessment of Pigment Wastewater by Physical, Chemical, and Biological Process)

  • 정종식;옥치상
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.81-88
    • /
    • 1998
  • This study was conducted to assess the characteristics of plgment wastewater and the removal rates of appropriate treatment by physical, chemical and biological Process, and the possibility of reuse for effluent. Based on the results, the wastewater qualities of pigment were pH 5.1$\pm$3.4, temperature 43.0$\pm$ 15.$0^{\circ}C$, BOD 1,431.4$\pm$589.6mg/l, COD 2,282.8$\pm$466.5mg/l, turbidity 1,340$\pm$820NTU, color 243.0$\pm$147.0unit, Pb 36.5$\pm$9.5mg/l and $Cr^+6$ 10.3$\pm$ 1.3mg/l, respectively. The removal rates of adsorption by activated carbon and filter process were BOD 40.6% , COD 57.0% , turbidity 89.6%, color 87.2%, Pb 86.0% and $Cr^+6$ 10.6%, respectively. And the removal rates of reduction, neutralization, coagulation and aP floatation process were BOD 18.2%, COD 24.3%, turbidity 74.3%, color 56.7%, Pb 68.6% and $Cr^+6$ 97.8%, respectively. The removal rates of activated sludge process were BOD 95.9%, COD 86.0%, turbidity 27.8%, color 25. 2%. Pb 26.9% and $Cr^+6$ 50.0% , respectively. The total removal rates of treatment by physical, chemical and biological process were BOD 98.0% , COD 95.4%, turbidity 98.1%, color 95.8%, Pb 97.0% and $Cr^+6$ 99.0%, respectively. According to the test results for possibility of reuse with coagulation-adsorption by activated carbon process of effluent, COD was higher than that of raw water and others were similar to that of raw water thus, it Is considered to be reused.

  • PDF

하수처리수 재이용에 따른 하천과 해역의 환경복원 및 수질관리 모델링 (Environmental Restoration and Water Quality Management Modeling of Coastal Area by Reuse of Treated Wastewater)

  • 이대인;윤양호;박일흠;이규형;조현서
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.505-521
    • /
    • 2007
  • This study estimated response of water duality and pollutant behavior according to the discharge and reuse of treated wastewater by three-dimensional eco-hydrodynamic model, and suggest plan that water quality management and environmental restoration in the coastal area including urban stream of Yeosu, Korea. Dispersions of low-saline water and COD by treated wastewater loads (design facility capacity, about $110,000m^3/d$) were very limited in near of effluent site. Nutrients, however, increase compared to the other water quality factors, especially total nitrogen was very sensitive to input loads. When reuse some of treated wastewater to Yeondeung stream, nitrogen was big influence on estuarine water quality. Although current characteristics of treated wastewater such as discharge and water quality were negligible to the change of marine environment, effluent concentration of COD, TN and TP, especially 40% of TN, are reduced within the allowable pollutant loads for satisfy environmental capacity and recommended water duality criteria. Also, controls of input point/non-point sources to Yeondeung stream and base concentration of pollutants in coastal sea itself are very necessary.

하수재이용 막여과 공정에서 막오염 저감을 위한 마이크로버블 적용성 평가 (Applicability evaluation of microbubble for membrane fouling reduction in wastewater reuse membrane process)

  • 이창하;김건엽;김형수;김지훈;이경일
    • 상하수도학회지
    • /
    • 제31권2호
    • /
    • pp.169-175
    • /
    • 2017
  • This study applied microbubbles to reduce membrane fouling in wastewater reuse membrane processes, evaluated and compared the transmembrane pressure with or without the application of microbubbles and the cleaning efficiency with the application of aeration and microbubbles. In addition, this study analyzed foulants removed from the membrane surface. Changes in the transmembrane pressure of membranes with the presence or absence of microbubbles were observed. As a result, transmembrane pressure (TMP) increasing rate decreased twofold when applying microbubbles to realize stable operations. This study compared and evaluated cleaning efficiency applying aeration and microbubbles. As a result, the cleaning efficiency was 5% higher on average when applying microbubbles. In turbidity and total organic carbon (TOC), foulants were discharged when applying microbubbles twice as much as applying aeration. It is thought that particulate foulants precipitated on the membrane surface were more likely to desorb because the adhesion between the membrane surface and particle was weakened by microbubbles. Therefore, it is considered possible to effectively control membrane fouling because of the increase in cleaning efficiency when applying microbubbles to wastewater reuse membrane processes.

BAF 공정을 이용한 제직폐수의 재이용 (Reuse of Weaving Wastewater with BAF Process)

  • 정용준;배종홍;권구호;민경석
    • 한국물환경학회지
    • /
    • 제20권6호
    • /
    • pp.664-669
    • /
    • 2004
  • An upflow BAF(Biological Aerated Filter) equipped with an expanded clay media was applied to reuse weaving wastewater of water jet loom. The performance of lab-scale biofilter was investigated by the adjustment of EBCTs(Empty Bed Contact Time) and the packing ratio of media, which were changed 1.1 to 3.7hr and 38 to 63%, respectively. In most conditions except 1.1hr of EBCT, BOD, CODcr, SS and Turbidity of the effluent were 1~4mg/L, 7~16mg/L, 1~5mg/L and 5~14NTU, where their removal efficiencies were 76~95%, 82~93%, 63~94% and 59~81%, respectively. From the observation of SEM(Scanning Electron Microscope) photographs of porous clay media, it was revealed that this media provided good performance of retaining microbes effectively. In addition, $0.44~0.49kgVSS/kgBOD_{rem}$. of low sludge reduction was expected. The most efficient back washing cycle and procedure were once per 4 to 9 days and air including collapse-pulsing method, respectively. Therefore, this system can be of use as an weaving wastewater treatment for reuse.

물 재이용을 위한 하수처리장 방류수 색도의 자외선처리에 미치는 과산화수소의 영향 (Effect of Hydrogen Peroxide on UV Treatment of Color in Secondary Effluent for Reclamation)

  • 박기영;맹승규;김기팔;이석헌;권지향;안규홍
    • 상하수도학회지
    • /
    • 제18권3호
    • /
    • pp.377-384
    • /
    • 2004
  • In the present study, a feasibility of an advanced oxidation process using UV/Hydrogen peroxide($H_2O_2$) system equipped with a medium pressure lamp for secondary effluent reclamation was investigated. Initial concentration of $H_2O_2$ and pH were changed to determine the optimum operation condition for the system. The removal efficiency of color was than 80% with 14.3mg/L of initial $H_2O_2$ and 5 minute of contact time in the UV/$H_2O_2$ system. The color removal was analyzed using first-order reaction equation. The dependence of rate constant (k) on initial $H_2O_2$ represented the rational relationship with maximum value. Residual $H_2O_2$ caused increase of effluent COD, since analyzing agent, dichromate, reacted with $H_2O_2$ in the sample. Therefore, excess initial concentration of $H_2O_2$ would significantly affect effluent COD measurement. At pH variation experiment, both residual $H_2O_2$ and color showed peak in the neutral pH range with the same pattern. Effect of $H_2O_2$ dose also enhanced color removal but raised residual $H_2O_2$ problem in the continuous operation UV system. In conclusion, these results indicated that medium pressure UV/$H_2O_2$ system could be used to control color in the secondary effluent for reclamation and reuse.

A Simple and Effective Purification Method for Removal of U(VI) from Soil-Flushing Effluent Using Precipitation: Distillation Process for Clearance

  • Hyun-Kyu Lee;Ilgook Kim;In-Ho Yoon;Wooshin Park;Seeun Chang;Hongrae Jeon;Sungbin Park
    • Journal of Radiation Protection and Research
    • /
    • 제48권2호
    • /
    • pp.77-83
    • /
    • 2023
  • Background: The purpose of this study is to purify uranium (U[VI])-contaminated soil-flushing effluent using the precipitation-distillation process for clearance. Precipitation and distillation are commonly used techniques for water treatment. We propose using a combination of these methods for the simple and effective removal of U(VI) ions from soil-flushing effluents. In addition, the U concentration (Bq/g) of solid waste generated in the proposed treatment process was analyzed to confirm whether it satisfies the clearance level. Materials and Methods: Uranium-contaminated soil was decontaminated by soil-flushing using 0.5 M sulfuric acid. The soil-flushing effluent was treated with sodium hydroxide powder to precipitate U(VI) ions, and the remaining U(VI) ions were removed by phosphate addition. The effluent from which U(VI) ions were removed was distilled for reuse as a soil-flushing eluent. Results and Discussion: The purification method using the precipitation-distillation process proposed in this study effectively removes U(VI) ions from U-contaminated soil-flushing effluent. In addition, most of the solid waste generated in the purification process satisfied the clearance level. Conclusion: The proposed purification process is considered to have potential as a soil-flushing effluent treatment method to reduce the amount of radioactive waste generated.