• Title/Summary/Keyword: reuse of the effluent

Search Result 130, Processing Time 0.021 seconds

Disinfection of Total Coliforms in Sewage Treatment Effluent using Electron Beam (전자선을 이용한 하수처리장 방류수내 대장균군 살균)

  • Kim, Yuri;Han, Bumsoo;Kim, Jinkyu;Kang, Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.376-381
    • /
    • 2004
  • The use of electron beam irradiation was investigated to disinfect total coliforms in the secondary sewage treatment effluent. Unchlorinated secondary effluent was irradiated at different dose of 0.2~1.0 kGy by 1 MeV, ELV-4 Model electron beam accelerator. It is interesting to note that a 100 % reduction in total coliforms and total colonies were achieved until a dose of approximately 0.8 kGy. Even at low dose of 0.2 kGy, the total coliforms and total colonies were successfully inactivated to the level of satisfying the new effluent discharge guideline. Besides disinfection of total coliforms, approximately a 50% removal in biochemical oxygen demand was pronounced at a dose of 0.2 kGy. More than 20 % removal in suspended solids and turbidity was also observed at a dose of 1.0 kGy. The application of electron beam irradiation appeared to be one of options to reuse sewage treatment effluent as agricultural or industrial water.

Development of Water Reusing System by Using Net3FM (Net Fit Fiber Filter Module) (그물망 압착식 섬유여과장치를 이용한 물 재이용 시스템 개발)

  • Kim, Jeongsook;Kim, Mi-Ran;Jo, Myung-Chan;Jang, Jeong-Gook
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1523-1528
    • /
    • 2012
  • This study was carried out to develop pilot plant Net3FM(Net Fit Fiber Filter Module) system and to suggest optimum operating condition for municipal wastewater reuse. SS concentration of biologically treated sewage effluent was reduced from 1.5~5.4mg/L to 0.4~1.0mg/L without coagulant injection in Net3FM system, and the SS removal efficiency was average 84.7%. And also, the removal efficiencies of COD and T-P were decreased slightly due to the SS removal by filtration. Coagulation-Filtration test was conducted to enhance the removal efficiencies of SS and T-P. The optimum dosage of coagulant was injected automatically by auto-controlling system, which is controlled by detecting value of turbidity of secondary sewage effluent. SS, COD and T-P concentrations in filtrated effluent were 0.21~0.57, 1.6~6.2 and 0.137~0.392mg/L with coagulant injection by in-line mixer in Net3FM system, respectively. The removal efficiencies of SS and T-P were highly increased to 92.8% and 89.8%, respectively. It was due to the combined the processes of coagulation and filtration. Net3FM system was evaluated that the removal efficiency of pollutants in secondary sewage effluent and the utilization potential as reclaimed water technology were very high.

The Reclamation of Secondary Effluent to Industrial Water by Co-60 γ Irradiation (Co-60 γ선을 이용한 하수처리수의 공업용수로의 재이용)

  • Lee, Myun-Joo;Jeoung, Young-Do;Nho, Young-Chang;Shon, Jong-Sik
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.838-842
    • /
    • 1999
  • In order to reclaim the effluent discharged from sewage treatment facilities application of an irradiation technique was investigated in this study for industrial water reuse. Samples were filtered using a sand filter to remove particles. Co-60 was used as an irradiation source and the irradiation dose was varied from 0.1 kGy to 15 kGy. The major source of colour in secondary treatment effluent was humic substances, which could be easily removed by irradiation with a dose 5 kGy. Bacteria could be also disinfected even at low doses. It was possible to get high quality water for industrial water reuse. But the effluent still contained a small amount of organic compounds. Further treatment, of residual organic compounds will be necessry if the higher quality water is required.

  • PDF

Water Quality Changes in Wastewater Effluent from the Unsaturated and Saturated Soil Aquifer Treatment(SAT) Columns Simulating Shallow Aquifer (얕은 불포화 및 포화 대수층을 모사한 SAT 토양칼럼에서의 하수처리장 방류수 처리 수질 변화)

  • Cha Woo-Suk;Kim Jung-Woo;Choi Hee-Chul;Won Jong-Ho;Kim In-Soo;Cho Jae-Weon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.18-24
    • /
    • 2005
  • Water quality changes of wastewater effluent in the shallow aquifier condition was investigated using laboratory unsaturated and saturated SAT columns for over five months. Average DOC removal was 31.9% in the unsaturated SAT column whereas no removal occurred in the saturated SAT column. Under the shallow aquifer condition, nitrification was not completed in the unsaturated SAT column, releasing residual ammonium nitrogen into the saturated SAT column. Short retention time (one day) in the shallow unsaturated SAT column rendered DO of about 2 mg/L to the influent of the saturated SAT column. Phosphate was not removed at all in the unsaturated SAT column while complete removal was achieved in the saturated column. Consequently, organic and inorganic compounds were removed under the shallow aquifer condition as effectively as was in deep aquifer, except for the release of ammonium and relatively high DO into the saturated SAT column.

Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse (처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성)

  • Han, Dong-U
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.213-220
    • /
    • 2002
  • This reserch was focused upon experimental study for wastewater reuse and conducted to evaluate optimum operating conditions of rapid filtration process such as filter flow rate, filtration time and backwashing condition for reuse of secondary-treated effluent using the pilot plant installed in real wastewater treatment plant. Also, the experiment on treatment char-acteristics of coagulant-added activated sludge process was performed to compare with activated sludge succeeded to rapid filtration. As the filtration velocity was 100m/day, the filtration time of the rapid filter connected with activated sludge system was revealed to 40 hours. Backwashing of filter was conducted by water wash and air scour. The optimum backwashing time and backwash flow rate were 10min and 10LPM, respectively. The quantity of backwashing water of the rapid filter was about 2% of total treated water.

Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

Optimization of Water Reuse System under Uncertainty (불확실성을 고려한 하수처리수 재이용 관로의 최적화)

  • Chung, Gun-Hui;Kim, Tae-Woong;Lee, Jeong-Ho;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.2
    • /
    • pp.131-138
    • /
    • 2010
  • Due to the increased water demand and severe drought as an effect of the global warming, the effluent from wastewater treatment plants becomes considered as an alternative water source to supply agricultural, industrial, and public (gardening) water demand. The effluent from the wastewater treatment plant is a sustainable water source because of its good quality and stable amount of water discharge. In this study, the water reuse system was developed to minimize total construction cost to cope with the uncertain water demand in future using two-stage stochastic linear programming with binary variables. The pipes in the water reuse network were constructed in two stages of which in the first stage, the water demands of users are assumed to be known, while the water demands in the second stage have uncertainty in the predicted value. However, the water reuse system has to be designed now when the future water demands are not known precisely. Therefore, the construction of a pipe parallel with the existing one was allowed to meet the increased water demands in the second stage. As a result, the trade-off of construction costs between a pipe with large diameter and two pipes having small diameters was evaluated and the optimal solution was found. Three scenarios for the future water demand were selected and a hypothetical water reuse network considering the uncertainties was optimized. The results provide the information about the economies of scale in the water reuse network and the long range water supply plan.

pH Control for Dyebath Reuse in Dyeing of Nylon with Binary Mixtures of Acid Dyes

  • Joonseok Koh;Park, Sang-Hyuck;Shim, Goo-Hwan;Kim, Jae-Pil
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.233-234
    • /
    • 2003
  • There are many advantages of dyebath-reuse, including less water to heat, less effluent to treat, and a reduced consumption of energy, dyes, and chemical auxiliaries. Because of the potential economic and environmental advantages involved in this process, clearly it is deserving of further investigation. Dyebath-reuse using pH-sliding system has been investigated in the dyeing of polyamide with a single acid dye in a previous study. (omitted)

  • PDF

A Study on Flux Efficiency on Membrane for Water Reclamination according to Coagulations (하수처리수 재이용을 위한 막분리 공정시 응집조건에 따른 투과효율 변화에 관한 연구)

  • Jung, Jin-Hee;Jang, Sung-Ho;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.20 no.6
    • /
    • pp.767-773
    • /
    • 2011
  • The objectives of this research are to investigate the proper coagulation conditions which are a type and doses of coagulants, mixing conditions (velocity gradients and mixing times), pH and so on through Jar-test, to evaluate the flux variations, permeate, backwashing according to characteristics of pretreatment of the wastewater by means of MF membranes for river maintenance water reuse. The effluent water from B-city K-sewage treatment plant are used for this research. Turbidity and suspended solids(SS) are 14.2 NTU and 10.4 mg/L respectively. This condition causes fouling for membrane process. The flux decline could be reduced when coagulation pretreatment was carried out. Optimal coagulations PAC which are commonly used in the sewage treatment plant was observed in this research. The results indicate that an optimal coagulation dose and pH are 80 ppm and pH of 7 respectively, but coagulation efficiency was lower at strong acid or strong base. Results showed that continuous and steady operations in membrane separation process by means of the effective removal of organic matter and turbidity with coagulation pretreatment of sewage secondary effluent were achieved.

Characteristics of Filtration Treatment Using Diatomite Filter Aids for Sewage Water Reuse (하수처리수 재이용을 위한 가압식 규조토 여과의 처리성능평가)

  • Lim, Byung Ran;Kim, Hee Seo;Go, Yeon Sil;Kim, Hyun Kab;Kim, Jong Hak;Lee, Tae Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.2
    • /
    • pp.145-151
    • /
    • 2019
  • The purpose of this study was to investigate treatment characteristics of diatomite filtration, that would allow water recovery from biologically-treated effluent for reuse. Diatomite, Celpure 100, and acid clay were used as filter-aids, with a support filter manufactured from polyethylene (PE), and polypropylene (PP). This pre-coating process using diatomite filter-aids, is used in the filtration range of pressure filters, and has consistently provided high-quality separation. The results showed that variations in average removal efficiency of SS, and T-P from biologically treated effluent by the diatomite-coated PE filter, were approximately 82.2 ~ 88.9 % and 4.8 ~ 21.1 %, respectively. T-P treatment efficiency of the PP filter pre-coated with diatomite and $Celpure^{(R)}100$ at $57.64g/m^2$, was approximately $24{\pm}10%$ and $40{\pm}15%$ on average, respectively. Particle size distribution of secondary effluent varied from 0.05 to $200{\mu}m$, and $d_{50}$ value was $20.76{\mu}m$. The size distribution of particles in the diatomite filtrate ranged from 1.26 to $101.1{\mu}m$ when pre-coated with diatomite filter-aid, at a content of $57.64g/m^2$. Diatomite filter aids, i.e., the particles that form the pre-coating layer, capture very fine particles as well as macromolecules, owing to their complex structure with numerous fine microscopic pores, and surface properties. The filtration process using diatomite and $Celpure^{(R)}100$ as filter aids, has been successfully applied, to recover water from sewage for reuse. The disadvantage of the process, is that the particle size of the filter-aid is spent, because of pressurization.