• 제목/요약/키워드: retention rate

검색결과 1,064건 처리시간 0.033초

치면열구전색술 - Advanced technique (Pit and fissure sealing - Advanced technique)

  • 이상호
    • 대한치과의사협회지
    • /
    • 제49권1호
    • /
    • pp.22-32
    • /
    • 2011
  • This paper reviewed the following subheadings and a few selected references in each section were discussed: ${\cdot}$ Sealant placed over caries; is it possible? Initial caries which is not sticky during proving is possible to be placed with sealants. ${\cdot}$ Prophylaxis of fissure; which method is most effective? Mechanical preparation with fissurotomy or resin polishing bur is one of the most effective method to clean the pit and fissure. ${\cdot}$ Glassionomer cement as a sealant; GIC, wheather it released fluoride or not, cannot be as cost-effective as resin-based sealants. ${\cdot}$ Sealant products; Color(white vs opaque), fluoride(containing vs not), filler component(filled vs non-filled) do not influenced the quality and retention of sealants. ${\cdot}$ Use of intermediate bonding agent to improve retention; Intermediate bonding may increase the retention rate of sealants ${\cdot}$ Penetration method of sealants; Several methods including waiting before light curing are recommended.

WEAR BEHAVIOR OF ATTACHMENTS FOR IMPLANT RETAINED OVERDENTURE ACCORDING TO MATERIAL IN VITRO

  • Lee Seok-Hyung
    • 대한치과보철학회지
    • /
    • 제41권6호
    • /
    • pp.747-761
    • /
    • 2003
  • Statement of problem. The proper materials of attachments for implant retained overdenture are unknown, such as the correlation between retention and abrasion, as well as the types of materials that are suitable for patrix and for matrix individually. Purpose of this study. The aim of this study was to select a proper clinical attachment system for a successful treatment as well as patient satisfaction. Methods. Retention and abrasion of 14 commercial attachments were measured during 15,000 removes. Results. A retentive part (matrix) which requires elasticity has to be made of gold while the patrix part which does not require elasticity has to be made of titanium. This gold matrix / titanium patrix combination showed the most retentive force and the least retention loss.

히드록시알킬 메틸셀룰로오스가 시멘트 모르타르의 보수성에 미치는 영향에 관한 연구 (Study on the Factor of Water Retention Capacity of Cement Mortar by Hydroxyalkyl Methylcellulose Ether)

  • 이무진
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.153-160
    • /
    • 1999
  • Water soluble hydroxyalkyl methycellulose ethers are used in a variety of applications incluing building industry as a supplementary agent used for incresing adhesives, water retention capacity, workability and viscosity modify. Water retention capacity(WRC) is the capability to contain water in the ploymer chain under condition of being mixed with cement. In general, the WRC is affected by the viscosity, the adding amount, the particle size, the rate of dissolving and the amount of substituted chemical in cellulose ethers. In the other words, WRC is increased as higher the viscosity, more adding amount, finer the particle size and longer the dissolving time of cellulose ethers. This thesis investigated each factor that effect the WRC, particularly the relation between degree of substitution(DS), molar of substitution(MS) and WRC. It is observed that WRC is not nearly affected by DS of cellulose ethers, but is changes proportionally as MS increases in the narrow range(0.10~2.25)

Dispersion of Li[Ni0.2Li0.2Mn0.6]O2 Powder by Surfactant for High-power Li-ion Cell

  • Yun, Su-Hyun;Park, Yong-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권7호
    • /
    • pp.1598-1602
    • /
    • 2009
  • The particle size of Li[$Ni_{0.2}Li_{0.2}Mn_{0.6}]O_2$ cathode powder was controlled effectively by dispersion using lauric acid as a surfactant. The samples treated by lauric acid showed smaller particles of approximately half the original size compared to the particles of a pristine sample. A structural change due to the dispersion of Li[$Ni_{0.2}Li_{0.2}Mn_{0.6}]O_2$ powder was not detected. The rate performance of the Li[$Ni_{0.2}Li_{0.2}Mn_{0.6}]O_2$ cathode was improved by dispersion using lauric acid, which was likely due to the decrease of the particle size. In particular, a sample dispersed pristine powder using lauric acid (L2) presented a greatly enhanced discharge capacity and capacity retention at a high C rate. The discharge capacity of a pristine sample was only 133 m$Ahg^{-1}$ (3C rate) and 96 m$Ahg^{-1}$ (12C rate) at the tenth cycle. In contrast, the L2 electrode delivered higher discharge capacities of 160 m$Ahg^{-1}$ (3C rate) and 129 m$Ahg^{-1}$ (12C rate) at the tenth cycle. The capacity retention at a rate of 12C/2C was also enhanced from ~ 45% (pristine sample) to 57% (L2) by treatment with lauric acid.

하천수정화 연못-습지 시스템 부들 습지셀의 초기 질산성질소 제거 (Nitrate Removal Rate in Cattail Wetland Cells of a Pond-Wetland System for Stream Water Treatment)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제5권6호
    • /
    • pp.24-29
    • /
    • 2002
  • Nitrate removal rate in three cattail wetland cells was investigated. They were a part of a pond-wetland system for stream water treatment demonstration. The system was composed of two ponds and six wetland cells. The acreage of each cell was approximately $150m^2$. The earth works for the system were finished from April 2000 to May 2000 and cattails were planted in the three cells in June 2000. Waters of Sinyang Stream flowing into Kohung Estuarine Lake were pumped into a primary pond, whose effluent was discharged into a secondary pond. The reservoir was formed by a tidal marsh reclamation project and located in southern coastal area of Korean Peninsula. Effluents from the secondary pond were funneled into the three cells. Volumes and water quality of inflow and outflow were analyzed from July 2000 through January 2001. Inflow and outflow averaged $20.2m^3/day$ and $19.8m^3/day$, respectively. Hydraulic retention time was about 1.6 days. Average influent and effluent nitrate concentration was $1.98mg/{\ell}$, $1.38mg/{\ell}$, respectively. Nitrate removal rate averaged $82.6mg\;m^{-2}\;day^{-1}$. Seasonal changes of nitrate retention rates were closely related to those of wetland cell temperatures. The average nitrate removal rate in the cells was a little lower, compared with that of $125.0mg\;m^{-2}\;day^{-1}$ for the wetlands operating in North America. This could be attributed to the initial stage of the cells and inclusion of three cold months into the seven-month study period. Root rhizosphere in wetland soils and litter-soil layers on cell bottoms could not developed. Increase of standing density of cattails within a few years will establish both root zones suitable for the nitrification of ammonia to nitrates and substrates beneficial to the denitrification of nitrates into nitrogen gases, which may lead to increase of the nitrate retention rate.

한우 및 유우에서의 indocyanine green 배설시험 및 혈장효소 활성치의 변화 (Indocyanine green excretion test and changes of plasma enzyme activities in Korean native cattle and dairy cattle)

  • 손민수;김철호;최일관;김진구;허주형;강정부
    • 대한수의학회지
    • /
    • 제32권4호
    • /
    • pp.677-681
    • /
    • 1992
  • This experiment was carried out to establish a proper method of indocyanine green(ICG) excrection test for a applicable liver function test in three Korean native cattle average weighing about 450kg and dairy cattle parity of 3~5. The results obtained the half life($T^1/_2$), fractional clearance rate(KICG), retention rate and plasma enzyme activities before or after injection of ICG were as follows. 1. The maximum absorbance of ICG in plasma was at 805nm. 2. Average half life and fractional clearance rate following the injection of ICG 0.25mg/kg body weight were $5.53{\pm}1.27$ minute and $0.131{\pm}0.031$/minute in Korean native cattle, $4.55{\pm}0.68$ minute and $0.156{\pm}0.031$/minute in dairy cattle, respectively. The ICG removal rate was exponentially liner for the first 15 minutes after injection both of Korean native cattle and dairy cattle. 3. Average plasma retention rate when 10, 15, 30 minutes after injection was $35.7{\pm}13.9$, $23.2{\pm}7.1$, $10.8{\pm}3.5%$ in Korean native cattle, $26.8{\pm}3.3$, $14.2{\pm}1.2$, $5.5{\pm}2.2%$ in dairy cattle, respectively. 4. Plasma enzyme activities(AST, ALT, r-GTP) were no variation among the before, during and after injection of ICG. From these results, ICG excretion test to cattle is applicable to evaluation of liver funtion in both clinical and research, and adopted the 15 minutes plasma sample as the sample taken at the ideal time for comparative purposes.

  • PDF

Effect of remifentanil on intraoperative fluid balance: a retrospective statistical examination of factors contributing to fluid balance

  • Ohara, Sayaka;Nishimura, Akiko;Tachikawa, Satoshi;Iijima, Takehiko
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권3호
    • /
    • pp.129-135
    • /
    • 2020
  • Background: Postoperative fluid retention is a factor that causes delay in recovery and unexpected adverse events. It is important to prevent intraoperative fluid retention, which is putatively caused by intraoperative release of stress hormones, such as ADH (anti-diuretic hormone) or others. We hypothesized that intraoperative analgesia may prevent pathological fluid retention. We retrospectively explored the relationship between analgesics and in-out balance in surgical patients from anesthesia records. Methods: Anesthetic records of 80 patients who had undergone orthognathic surgery were checked in this study. Patients were anesthetized with either TIVA (propofol and remifentanil) or inhalational anesthesia (sevoflurane and remifentanil). During surgery, acetated Ringer's solution was infused for maintenance at a rate of 3-5 ml/kg/h at the discretion of the anesthetist. The perioperative parameters, including the amount of crystalloid and colloid infused, and the amount of urine and bleeding were checked. Furthermore, we checked the amount and administration rate of remifentanil during the surgical procedure. The correlation coefficient between the remifentanil dose and the in-out balance or the urinary output was analyzed using the Pearson correlation coefficient. The contributing factor to fluid retention, including urinary output, was statistically examined by means of multivariate logistic regression analysis. Results: A significant positive correlation was found between remifentanil dose and urinary output. Urinary output less than 0.04 ml/kg/min was suggested to cause positive fluid balance. Although in-out balance approaches zero balance with increase in remifentanil administration rate, no contributing factor for near-zero fluid balance was statistically picked up. The remifentanil administration rate was statistically picked up as the significant factor for higher urinary output (> 0.04 ml/kg/min) (OR, 2,644; 95% CI, 3.2-2.2 × 106) among perioperative parameters. Conclusions: In conclusion, remifentanil contributes in maintaining the urinary output during general anesthesia. Although further prospective study is needed to confirm this hypothesis, it was suggested that fluid retention could be avoided through suppressing intraoperative stress response by means of appropriate maintenance of remifentanil infusion rate.

CMP 패드 컨디셔너의 제조공법에 따른 패드 컨디셔닝 특성 (The properties of pad conditioning according to manufacturing methods of CMP pad conditioner)

  • 강승구;송민석;지원호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.362-365
    • /
    • 2005
  • Currently Chemical Mechanical Planarization (CMP) has become an essential step in the overall semiconductor wafer fabrication technology. Especially the CMP pad conditioner, one of the diamond tools, is required to have strong diamond retention. Strong cohesion between diamond grits and metal matrix prevents macro scratch on the wafer. If diamond retention is weak, the diamond will be pulled out of metal matrix. The pulled diamond grits are causative of macro scratch on wafer during CMP process. Firstly, some results will be reported of cohesion between diamond grits and metal matrix on the diamond tools prepared by three different manufacturing methods. A measuring instrument with sharp cemented carbide connected with a push-pull gauge was manufactured to measure the cohesion between diamond grits and metal matrix. The retention force of brazed diamond tool was stronger than the others. The retention force was also increased in proportion to the contact area of diamond grits and metal matrix. The brazed diamond tool has a strong chemical combination of the interlayer composed of chrome in metal matrix and carbon which enhance the interfacial cohesion strength between diamond grits and metal matrix. Secondly, we measured real-time data of the coefficient of friction and the pad wear rate by using CMP tester (CETR, CP-4). CMP pad conditioner samples were manufactured by brazed, electro-plated and sintered methods. The coefficient of friction and the pad wear rate were shown differently according to the arranged diamond patterns. Consequently, the coefficient of friction is increased according as the space between diamonds is increased or the concentration of diamonds is decreased. The pad wear rate is increased according as the degree of diamond protrusion is increased.

  • PDF

개에서의 indocyanine green 배설시험 및 혈장효소 활성치의 변화 (Indocyanine green excretion test and changes of plasma enzyme activites in dogs)

  • 김철호;최일관;손민수;김진구;강정부
    • 대한수의학회지
    • /
    • 제32권4호
    • /
    • pp.671-675
    • /
    • 1992
  • This experiment was carried out to establish a proper method of indocyanine green(ICG) excretion test for a applicable liver function test in dogs. The half life(T1/2), fractional clearance rate(KICG) and retention rate after injection of ICG with or without administred carbon tetrachloride($CCl_4$) were also invested. The results obtained were as follows ; 1. The maximum absorbance of ICG in plasma was at 810nm. 2. Half life and fractional clearance rate when administered 0.25 and 0.50mg of ICG per Kilogram body weight were $6.33{\pm}0.58$ minutes and $0.11{\pm}0.99$/minute in the former, $10.01{\pm}1.0$ minutes and $0.07{\pm}0.007$/minute in the latter, respectively. The ICG removal rate was exponentially linear for the first 15 minutes after injection both, of 0.25 and 0.50mg of ICG. 3. One day following the administration of $0.0042m{\ell}\;CCl_4$ kilogram body weight which injected 0.50mg of ICG, half life was more longer and fractional clearance rate was significantly reduced than that of ICG single injection. 4. Plasma retention rate when 15, 30, 45 minutes after injection dose of 0.25 and 0.50mg ICG per Kilogram body weight, $14.7{\pm}4.8$, $5.1{\pm}3.1$, $2.6{\pm}1.6%$ in the former, $26.9{\pm}1.8$, $11.1{\pm}2.4$, $4.8{\pm}1.3%$ in the latter, respectively. However, after administration of $CCl_4$, plasma retention rate of ICG at a dose of 0.50mg, it was $39.3{\pm}0.9$, $16{\pm}2.9$, $10.7{\pm}0.1%$, respectively. 5. Plasma enzyme(AST, ALT, r-GTP) activities administered with $CCl_4$ were increased, but there was no change which injected any dose of single ICG injection. From these results, ICG excretion test to dog is applicable to evaluation of liver function in both clinical and research.

  • PDF

Thermomechanical Properties and Shape Memory Effect of PET-PEG Copolymers Cross-linked with Pentaerythritol

  • Shim, Yong-Shik;Chun, Byoung-Chul;Chung, Yong-Chan
    • Fibers and Polymers
    • /
    • 제7권4호
    • /
    • pp.328-332
    • /
    • 2006
  • Poly(ethylene terephthalate) (PET) and poly(ethylene glycol) (PEG) copolymers cross-linked with pentaerythritol, a four-way cross-linker, are prepared to compare their mechanical and shape memory properties with the one cross-linked by glycerol. Composition of PEG and pentaerythritol is varied to search for the one with the best mechanical and shape memory properties. The highest shape recovery rate is observed for the copolymer composed of 30 mol% PEG-200 and 2.5 mol% pentaerythritol. Four-way cross-linking by pentaerythritol significantly improves shape recovery rate and retention of high shape recovery rate after repeated use compared to the one cross-linked by glycerol, a three-way cross-linker, and difference and advantage of additional cross-linking point are discussed.