• Title/Summary/Keyword: retaxation

Search Result 2, Processing Time 0.014 seconds

Studies on the Adrenotropic Receptors of the Isolated Urinary Bladder from Sebastes Inermis (볼낙(Sebastes inermis) 방광(膀胱)의 Adrenotropic Receptor에 관(關)한 연구(硏究))

  • Sohn, Yong-Seuk;Hong, Ki-Whan;Park, Jung-Yang
    • The Korean Journal of Pharmacology
    • /
    • v.5 no.2
    • /
    • pp.115-119
    • /
    • 1969
  • The authors studied the adrenotropic receptors of isolated urinary bladder from Sebastes inermis, using adrenergic activators such as epinephrine, nor-epinephrine, isoproterenol and phenylephrine and adrenergic blocking agents such as phenoxybenzamine, pronethalol and propranolol. The studies have revealed the following results. 1) The spontaneous motility of isolated bladder from Sebastes inermis was inhibited by epinephrine nor-epinephrine, isoproterenol and phenylephrine. 2) The inhibitory effect of phenylephrine on the Sebastes inermis bladder was blocked by phenoxybensamine. 3) The inhibitory effect of isoproterenol was blocked by pronethalol and propranolol. 4) The effect of epinephrine and nor-epinephrine on the Sebastes inermis bladder was usually not blocked by either kind of blocking agent alone, but was blocked by a combination of ${\alpha}\;and\;{\beta}$ blockades. 5) It is, therefore, concluded that the Sebastes inermis bladder has alpha and that both receptors, and that both receptors subserve retaxation or inhibition.

  • PDF

Shrinkage Stress Analysis of Concrete Slab with Shrinkage Strip in Multi-Story Building (수축대를 사용한 고층건물 콘크리트 슬래브의 건조수축응력 해석)

  • 김한수;조석희
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.726-733
    • /
    • 2002
  • Shrinkage strip or separation strip is a temporary joint that is left open for a certain time during construction to allow a significant part of the shrinkage to take place without inducing stress. A shrinkage stress analysis method of shrinkage strip in concrete slab of multi-story building considering the relaxation effect of creep and construction sequence is proposed. The analysis results of 10-story example building show that the effect of shrinkage strip can be analyzed easily by the proposed method. And shrinkage strip installed in a particular floor makes the stress of that floor reduced and the stress of the other floors increased a little. The rate and amount of stress reduced with closing time mainly depends on the development of shrinkage with time of concrete model used. The amount of stress reduced is determined by the amount of shrinkage strain developed before the closing of shrinkage strip.