• Title/Summary/Keyword: response spectrum method

Search Result 514, Processing Time 0.027 seconds

Probability density evolution analysis on dynamic response and reliability estimation of wind-excited transmission towers

  • Zhang, Lin-Lin;Li, Jie
    • Wind and Structures
    • /
    • v.10 no.1
    • /
    • pp.45-60
    • /
    • 2007
  • Transmission tower is a vital component in electrical system. In order to accurately compute the dynamic response and reliability of transmission tower under the excitation of wind loading, a new method termed as probability density evolution method (PDEM) is introduced in the paper. The PDEM had been proved to be of high accuracy and efficiency in most kinds of stochastic structural analysis. Consequently, it is very hopeful for the above needs to apply the PDEM in dynamic response of wind-excited transmission towers. Meanwhile, this paper explores the wind stochastic field from stochastic Fourier spectrum. Based on this new viewpoint, the basic random parameters of the wind stochastic field, the roughness length $z_0$ and the mean wind velocity at 10 m heigh $U_{10}$, as well as their probability density functions, are investigated. A latticed steel transmission tower subject to wind loading is studied in detail. It is shown that not only the statistic quantities of the dynamic response, but also the instantaneous PDF of the response and the time varying reliability can be worked out by the proposed method. The results demonstrate that the PDEM is feasible and efficient in the dynamic response and reliability analysis of wind-excited transmission towers.

Study on Improvement of Response Spectrum Analysis of Pile-supported Structure: Focusing on the Natural Periods and Input Ground Acceleration (잔교식 구조물의 응답스펙트럼 해석법 개선사항 도출 연구: 고유주기 및 입력지반가속도를 중점으로)

  • Yun, Jung-Won;Han, Jin-Tae;Kim, Jong-Kwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.6
    • /
    • pp.17-34
    • /
    • 2020
  • In response spectrum analysis of pile-supported structure, an amplified seismic wave should be used as the input ground acceleration through the site-response analysis. However, each design standard uses different input ground acceleration criteria, which leads to confusion in determining the appropriate input ground acceleration. In this study, the ground accelerations were calculated through dynamic centrifuge model test, and the response spectrum analysis was performed using the calculated ground acceleration. Then, the moments derived from the test and analysis were compared, and a method for determining the appropriate input ground acceleration in response spectrum analysis was presented. Comparison of the experimental and simulated results reveals that modeling of the ground using elastic springs allows proper simulation of the natural period of the structure, and the use of a seismic wave that is amplified at the ground surface as the input ground acceleration provided the most accurate results for the response analysis of pile-supported structures in sands.

Application of Response Spectrum Method for Analysis of a Floor System Subjected to Dynamic Loads on Multiple Locations (복수 절점에 가진되는 건물 바닥판의 해석을 위한 응답스펙트럼 해석법의 응용)

  • 김태호;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.21-32
    • /
    • 2002
  • In general, the response spectrum analysis method (R.S.A) is widely used for seismic analysis of building structure. But, it is not common to apply R.S.A for the analysis of structural vibration caused by dynamic loads of equipments, machines and moving leads, etc. The time history analysis method(T.H.A) for the vibration analysis, compared with R.S.A, is very complex, difficult and time consuming. So the application of R.S.A, that is convenient to calculate maximum responses for structural vibration, is proposed in this study. At first, the procedure for the application of the R.S.A to calculate of the maximum vibration response induced by dynamic load applied on the single point is described. And then, the process, which can save the time and the memory for calculation of the maximum vibration response induced by dynamic loads on the multi-point is proposed, and the maximum structural response caused by moving loads are obtained. Lastly, the accuracy of the proposed method is verified by comparing the results of R.S.A to T.H.A for some example models.

Generation of critical and compatible seismic ground acceleration time histories for high-tech facilities

  • Hong, X.J.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.6
    • /
    • pp.687-707
    • /
    • 2007
  • High-tech facilities engaged in the production of semiconductors and optical microscopes are extremely expensive, which may require time-domain analysis for seismic resistant design in consideration of the most critical directions of seismic ground motions. This paper presents a framework for generating three-dimensional critical seismic ground acceleration time histories compatible with the response spectra specified in seismic design codes. The most critical directions of seismic ground motions associated with the maximum response of a high-tech facility are first identified. A new numerical method is then proposed to derive the power spectrum density functions of ground accelerations which are compatible with the response spectra specified in seismic design codes in critical directions. The ground acceleration time histories for the high-tech facility along the structural axes are generated by applying the spectral representation method to the power spectrum density function matrix and then multiplied by envelope functions to consider nonstationarity of ground motions. The proposed framework is finally applied to a typical three-story high-tech facility, and the numerical results demonstrate the feasibility of the proposed approach.

Application of Response Spectrum Method to a Bridge subjected to Multiple Support Excitation (다지점(多支點) 지진하중(地震荷重) 받는 교량(橋梁)에 대한 응답(應答) 스펙트럼법(法)의 적용(適用))

  • Kang, Kee Dong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 1990
  • The dynamic behaviour of a four-span continuous girder railway bridge subjected to multiple support excitations is investigated using the response spectrum method. Small-amplitude oscillations and linear-elastic material behaviour are assumed. Soil-structure interaction effects are disregarded and only the out-of-plane response of the bridge is considered. The results of the response spectrum analysis are compared with those from a time history analysis. Different combination rules for the superposition of modal maxima as well as supports are employed, such as square-root-of-sum-squares, double sum and p-norm methods.

  • PDF

Inelastic Response Evaluation of Structures using Capacity Spectrum Method (역량스펙트럼 방법을 이용한 구조물의 비탄성 응답의 평가)

  • 송종걸
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.161-168
    • /
    • 2002
  • To evaluate seismic performance of bridges, two procedures far capacity spectrum method are presented. The capacity spectrum procedures include the reduction factor-ductility-period relationship in order to construct the inelastic demand spectra from the elastic demand spectra. Application of the procedures is illustrated by example analysis. Maximum displacements estimated by the procedures are compared to those by inelastic time history analysis for several artificial earthquakes. The results show that the maximum displacements estimated by the procedures are, on overall, smaller than those by the inelastic time history analysis

  • PDF

Determination of Shock Response Spectrum Using FRF of Statistical Energy Analysis Method (통계적 에너지 분석법의 FRF를 이용한 충격 응답 스텍트럼(SRS)의 결정)

  • 구성완;황철규;김인성
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.551-560
    • /
    • 2004
  • A method how to determine the shock response spectrum from the FRF of the statistical energy analysis( SEA ) is presented here. The system of 3 different Plates connected by bolt joints is selected simulating missile structural sections Joined together. First, the SEA model was rendered by SEA parameters which were determined from experimental SEA method. Then, the mobility power was input to the SEA model and we can verify the validity of the model in the medium to high frequency range checking the reproduction of output average velocity. And, the shock induced shock response spectrum(SRS) was obtained using SEA FRF and arbitrarily chosen experimental FRF. We have compared the thus obtained SRS with actually measured SRS and they were relatively in good agreement. In this paper, we used the measured SEA FRF and therefore we have got the SRS well agreed with actually measured SHS even in the low frequency range. If the SEA FRF of well verified SEA model is used, the good result will come out in SEA effective frequency range which is more important at SRS.

Seismic Qualification of the Air Cleaning Units for Nuclear Power Plant Ulchin 5&6 (울진 원자력발전소 5,6 호기용 공기정화기에 대한 내진검증)

  • Kim, Jin-Young;Rhee, Hui-Nam;Lee, Joon-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1376-1383
    • /
    • 2002
  • Seismic qualification of the Air Cleaning Units for nuclear power plant Ulchin 5&6 has been performed with the guideline of ASME Section III and IEEE 344 code. By using the structural and geometrical similarity analysis, the three models to be analyzed are condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper.

Determination of torsional irregularity in response spectrum analysis of building structures

  • Aliakbari, Fatemeh;Garivani, Sadegh;Shahmari, Ali
    • Structural Engineering and Mechanics
    • /
    • v.74 no.5
    • /
    • pp.699-709
    • /
    • 2020
  • Torsional irregularity is one of the most probable types of horizontal irregularity and existence of this irregularity in most of the structural loading codes is determined by calculating the ratio of the maximum to the average story drift. No specific method has been previously recommended by the codes to calculate the mentioned ratio in the response spectrum analyses. In the current investigation, nine steel building structures with different plan layouts and number of stories have been analyzed and designed in order to evaluate the efficiency of three methods for calculating the ratio of the maximum to the average story drift in the response spectrum analyses. It should be noted that one of these methods is the approach used by current version of ETABS software andother ones are proposed in this paper. The obtained results using the proposed methods are compared with the time history analysis results. The comparisons show that one of these methods underestimates the mentioned ratio in all studied models, however, the other two methods have shown similar results. It is also found that the plan layouts and irregularities can affect how these methods estimate the ratios compared to those obtained by the time history analysis. Generally, it can be concluded that all of these methods can properly predict the ratio with acceptable errors.

Seismic Qualification of the Air Cleaning Units for Nuclear Power Plant Ulchin 5&6 (울진 원자력발전소 5,6호기용 공기정화기에 대한 내진검증)

  • Lee, Joon-Keun;Kim, Jin-Young;Chung, Phil-Joong
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.404-409
    • /
    • 2001
  • Seismic qualification of the Air Cleaning Units for nuclear power plant Ulchin 5&6 has been performed with the guideline of ASME Section III and IEEE 344 code. By using the structural and geometrical similarity analysis, the three models to be analyzed is condensed into a single model and, at the same time, the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz, which is the upper frequency limit of the seismic load, response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and electric stability of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As the all combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, the authors confirm the safety of the nuclear equipments Air Cleaning Units studied in this paper.

  • PDF