• 제목/요약/키워드: response spectrum compatibility

검색결과 6건 처리시간 0.02초

Generation of critical and compatible seismic ground acceleration time histories for high-tech facilities

  • Hong, X.J.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제26권6호
    • /
    • pp.687-707
    • /
    • 2007
  • High-tech facilities engaged in the production of semiconductors and optical microscopes are extremely expensive, which may require time-domain analysis for seismic resistant design in consideration of the most critical directions of seismic ground motions. This paper presents a framework for generating three-dimensional critical seismic ground acceleration time histories compatible with the response spectra specified in seismic design codes. The most critical directions of seismic ground motions associated with the maximum response of a high-tech facility are first identified. A new numerical method is then proposed to derive the power spectrum density functions of ground accelerations which are compatible with the response spectra specified in seismic design codes in critical directions. The ground acceleration time histories for the high-tech facility along the structural axes are generated by applying the spectral representation method to the power spectrum density function matrix and then multiplied by envelope functions to consider nonstationarity of ground motions. The proposed framework is finally applied to a typical three-story high-tech facility, and the numerical results demonstrate the feasibility of the proposed approach.

Design response spectra-compliant real and synthetic GMS for seismic analysis of seismically isolated nuclear reactor containment building

  • Ali, Ahmer;Abu-Hayah, Nadin;Kim, Dookie;Cho, Sung Gook
    • Nuclear Engineering and Technology
    • /
    • 제49권4호
    • /
    • pp.825-837
    • /
    • 2017
  • Due to the severe impacts of recent earthquakes, the use of seismic isolation is paramount for the safety of nuclear structures. The diversity observed in seismic events demands ongoing research to analyze the devastating attributes involved, and hence to enhance the sustainability of base-isolated nuclear power plants. This study reports the seismic performance of a seismically-isolated nuclear reactor containment building (NRCB) under strong short-period ground motions (SPGMs) and long-period ground motions (LPGMs). The United States Nuclear Regulatory Commission-based design response spectrum for the seismic design of nuclear power plants is stipulated as the reference spectrum for ground motion selection. Within the period range(s) of interest, the spectral matching of selected records with the target spectrum is ensured using the spectral-compatibility approach. NRC-compliant SPGMs and LPGMs from the mega-thrust Tohoku earthquake are used to obtain the structural response of the base-isolated NRCB. To account for the lack of earthquakes in low-to-moderate seismicity zones and the gap in the artificial synthesis of long-period records, wavelet-decomposition based autoregressive moving average modeling for artificial generation of real ground motions is performed. Based on analysis results from real and simulated SPGMs versus LPGMs, the performance of NRCBs is discussed with suggestions for future research and seismic provisions.

An evaluation of the seismic response of symmetric steel space buildings

  • Yon, Burak
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.399-412
    • /
    • 2016
  • This paper evaluates the seismic response of three dimensional steel space buildings using the spread plastic hinge approach. A numerical study was carried out in which a sample steel space building was selected for pushover analysis and incremental nonlinear dynamic time history analysis. For the nonlinear analysis, three earthquake acceleration records were selected to ensure compatibility with the design spectrum defined in the Turkish Earthquake Code. The interstorey drift, capacity curve, maximum responses and dynamic pushover curves of the building were obtained. The analysis results were compared and good correlation was obtained between the idealized dynamic analyses envelopes with and static pushover curves for the selected building. As a result to more accurately account response of steel buildings, dynamic pushover envelopes can be obtained and compared with static pushover curve of the building.

Assessment of nonlinear static and incremental dynamic analyses for RC structures

  • Oncu, Mehmet Emin;Yon, Merve Sahin
    • Computers and Concrete
    • /
    • 제18권6호
    • /
    • pp.1195-1211
    • /
    • 2016
  • In this study, seismic behaviour of reinforced concrete buildings using the pushover and incremental dynamic analysis method was investigated. A numerical study was performed for a reinforced concrete frame building. Pushover analysis according to uniform and triangular load shapes and incremental dynamic analyses were performed for selected building. For the nonlinear analysis, three ground motion records were selected to ensure compatibility with the design spectrum defined in the Turkish Seismic Code. The maximum response, dynamic pushover curve, capacity curves, interstorey drifts and moment rotation curves for various element ends of the selected building were obtained. Results were compared each other and good correlation was obtained between the dynamic analyses envelope with static pushover curves for the building.

천연가스 생산기지 내 UPS시스템의 해석모델 개발 (Development of an Analysis Model for UPS System of LNG Receiving Terminal Facilities)

  • 국승규;홍성경;김준호;최원목;박영호
    • 한국전산구조공학회논문집
    • /
    • 제29권6호
    • /
    • pp.539-545
    • /
    • 2016
  • 천연가스 생산기지 내의 UPS시스템은 지진 시에도 기능성을 유지해야 하는 주요 설비 중 하나이다. 이 연구에서는 IEEE Std 693-2005 기준을 토대로 대형 진동대를 이용한 UPS시스템의 동특성 탐색시험을 수행하고 기기의 고유진동수와 모드감쇠, 모드형상 등을 도출하였다. 또한, 3축 시간이력시험을 통해 지진 시 기기의 거동 및 부재의 발생응력을 확인하였다. 유한요소모델을 생성하여 고유치해석을 수행하고 이를 동특성 탐색시험의 시험값과 비교, 분석하여 해석모델을 개선하고 자중해석과 응답스펙트럼 해석을 수행하여 조합응력을 3축 시간이력시험의 시험값과 비교하였다. 개선된 유한요소 해석모델의 동특성과 조합응력이 시험 결과와 유사함을 입증하여 개선된 UPS시스템 해석모델의 적합성을 제시하였다.

초동극성분포를 이용한 홍성지진의 Focal Mechanism 연구 (A Study on the Focal Mechanism of the Hongsung Earthquake from the P-Wave Polarity Distributions)

  • 김준경
    • 지질공학
    • /
    • 제1권1호
    • /
    • pp.121-136
    • /
    • 1991
  • 본 연구에서는 P파형의 초동극성 분포를 이용하여 홍성지진의 Focal Mechanism을 평가하였다. 비선형 전산처리과정을 이용하여 원지진진앙거리에서 관측된 9개의 P파형의 초동극성 분포와 주향, 경사 및 상반변위방향의 변화로부터 구한 Focal Mechanism과의 부합성을 조사하였다. 위의 과정을 이용하여 처리한 결과 주단층면의 주향 및 겅사는 약 247도 및 약 78도로서 홍성부근지역의 선구조와 잘 일치함을 보여주었다. 그러나, 주단층면의 상반변위 방향은 약 40도에서 약 160도 까지의 광범위한 값을 보여주었으나, 이는 관측점의 방위각 분포가 불충분하기 때문인 것으로 분석되었다. 위에서 결정된 Focal Mechanism이 의미하는 주응력 방향은 일본 트렌치를 따라서 태평양판이 유라시아판 아래로 Subduction할 때 가능한 지응력장가 상반되지 않음을 보여 주었다. 또한, 이러한 Focal Mechanism으로부터 원자력발전소나 핵폐기물 처리장 및 처분장 건설시, 부지고유응답 스펙트럼 및 강지진동 자료와 같은 내진설계기준을 위해 필요한 한반도의 지진지체구조 특성에 대한 정보를 얻을 수 있다.

  • PDF