Background: This study aims to introduce the formulation of the regulation for the selection of respirators for accident preparedness chemicals (APCs) according to chemical workplace situations and to determine on-site applicability. Methods: Workplaces were grouped into seven work categories, and APCs were classified into six groups to select adequate respirators. A survey was conducted to enhance the understanding of work situations and adequate respirators. The total number of subjects surveyed in 2018 was 201 managers and handlers, and that in 2019 was 91 handlers and 204 managers. Results: Adequate respirators were allocated to each cell using the matrix method. The study observed an overall lack of understanding of work situations, especially in the operation of open devices, which was the highest at 32.7%. Despite its implementation in 2015, 17.6% and 25.0% of the managers and APCs handlers, respectively, were unaware of the regulations for selecting respirators. Only 70.4% of the APCs handler wore respirators in compliance with regulations. Conclusion: The method for selecting respirators according to work situations using the matrix method is considered reasonable. Thus, this study suggests that the development of educational contents and reinforcing education should be essential steps to increasing awareness of regulations.
There was a difference in recognition of respirators according to the educational performance environment. they were showed higher recognition of respirators of group by internal and external mix trainer, less than 6 months, over 1hour, more than 5 times, variety of education. To identify the relationship between types of job classification(typical and atypical)and the levels of recognition of respirators, a total of 153 workers in a business workplace. mainly, typical workers showed higher recognition of respirators than atypical workers. Training of correct wearing showed high demands both typical and atypical workers. Descriptive statistics(SAS ver 9.2)was performed. the results of recognition of respirators were analyzed the mean and standard deviation by t-test, and anova, fit factor is used geometric means(geometric standard deviation), paired t-test, Wilcoxon analysis(P=0.05). Particulate filtering facepiece respirators (PFFR) is one of the most widely used items of personal protective equipments, and a tight fit of the respirators on the wearers is critical for the protection effectiveness. In order to effectively protect the workers through the respirators, it is important to find and evaluate the ways that can be readily applicable at the workplace to improve the fit of the respirators. This study was designed to evaluate effects of mask style (cup or foldable type) and donning training on fit factors (FF) of the respirators, since these are available at various workplace, especially at small business workplace. A total of 40 study subjects, comprised of employment type workers in metalworking industries, were enrolled in this study. The FF were quantitatively measured before and after training related to the proper donning and use of cup or foldable-type respirators. The pass/fail criterion of FF was set at 100. After the donning training for the cup-type mask, fit test were increased by 769%. but foldable-type mask was also increased after the donning training, the GM of FF for the foldable-type mask and it's increase rate were smaller as compared to the cup-type mask. Furthermore, the differences of the increase rates of the GM of FF in employment type of the subjects were not significantly for the foldable-type mask. These results imply that the raining on the donning and use of PFFR can enhance the protection effectiveness of cup or foldable-type mask, and that the training effects for the foldable-type mask is less significant than that for the cup-type mask. Therefore, it is recommended that the donning training and fit tests should be conducted before the use of the PFFR, and listening to workers opinion regularly.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.4
no.2
/
pp.180-188
/
1994
This study was designed to investigate qualitatively whether respirators now being used in workplaces tit workers iflfaces well or not. Leak sites were determined after exposing the subjects to fluorescent aerosol and were analyzed by gender, brand and manufacturing nation. The results were as follows ; 1. Among those leak sites which were classified into four areas(nose, cheek, lip and chin), test aerosol was mostly deposited on the nose and the cheek areas. 2. The mean number of leak sites observed from the female subjects were 2.3 while the number were 2.2 from the male subjects. The most frequently observed leak site was nose and followed by chin, lip and cheek in descending order of frequency. 3. Among different brands of respirators, different leak sites were observed. Test subjects wearing the Sand N brands were more heavily exposed than those of wearing the D and M brands. 4. No significant difference of the number of leak sites were found between Korean-made and American-made masks. However, the most frequent leak site observed for the Korean-made ones was the nose area while it was the chin area for the American-made ones. 5. Analyses of 97 leak sites by shape showed that 27(27.8%) were point types, 54(55.7%) diffuse types and 16(16.5%) streamline types. 6. Test subjects indicated that the facepieces of Korean-made respirators were harder and smaller in size than those of American-made one. The most comfortable respirator selected was the respirator by the N Co. and the most uncomfortable one was the respirator by the D Co. This study suggests that many half-mask respirators now being used in the workplaces may not fit to workers well. Therefore, when selecting respirators, employers are advised to test respirators if they fit to workers well. And manufacturers are recommended to produce effective and comfortable respirators tested qualitatively and quantitatively not only in the laboratory but also in the field.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.21
no.1
/
pp.62-71
/
2011
There is widespread concern that particulate filtering respirators (PFRs) available in Korea will be efficient for nanoparticles. The purpose of this review study was to analyse research literature and recommend PFRs suitable for protection against nanoparticles. In all studies, respirators containing electret filter media (N95, P100 and FFP2, FFP3) consistently have their MPPS below 100 nm and particle penetration levels at the MPPS can vary widely, but they comply with NIOSH or EN certification criterion. Electret filtering facepieces respirators (FFRs) were found to shift in the Most-Penetrating Particle Size(MPPS) from 30-60 to 200-300 nm range after the electric charges were removed, and FFRs were above their minimum penetrations of criterion. Korean special class and first class FFRs (the same as FFP3 and FFP2, respectively) would be effcient for nanoparticles unless FFRs are removed electric charges. It is difficult to evaluate if mechanical PFRs is efficient for nanoparticles due to the lack of related materials.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.24
no.3
/
pp.393-403
/
2014
Objectives: Korean Occupational Safety and Health Agency(KOSHA) intended to provide guidance to respirator program administrators on respirator selection. The purpose of this project is to suggest a preliminary respirator selection guide(PRSG) for the final guidance certified by KOSHA for the correct selection of respirators in the workplace. Materials: This PRSG was made on the based of current status of respirator usage including respirators available in Korea, foreign documents search and so on. PRSG was partially modified NIOSH pocket guide to chemical hazards, 3M Respirator Protection Resource Guide(RPRG) and OSHA Assigned Protection Factor(APF) rulemaking. Results: Respirators for chemicals having Korean Occupational Exposure Limits(KOELs) can be recommended in PRSG. For the others chemicals that have no KOELs, PRSG tells you what respirators you can select, using a simple step-by-step approach after health hazard assessment like HSE procedure. Conclusions: PRSG helps you to decide the right level of protection for a given hazardous substance and how to select the right respirators. PRSG is thus expected to reduce significant misuses of respirators for the work environment.
This review begins with a brief expression of aerosol capture mechanism of fibrous filter(s) and performance of particulate removing respirators. The more complicated and detailed discussion is not included in this articles. Filtration efficiency and pressure drop are introduced as quality factor ( $q_{F}$) and the way in which filtration efficiency varies with particle size is discussed. Quality factors fro filters recently certified in USA were found to be very higher than those of filters made in Korea, China and USA filters certified with old certified standards. Electrically charged filters are widely used because they have high filtration efficiency and low pressure drop, but their efficiency decreases sharply at the condition occurring wet and oil mist. A discussion is given of respirator leakage through face seal and filter media with fit testing and total inward leakage testing. Since fit factor (FF) refers to the reciprocal of the fraction of the total air entering a respirator through face seal leakage , the degree of fitting performance for respirators is expected with FF. Because respirators made in Korea had generally lower FFs than respirators made in USA, it is necessary to develope respirators that fit properly for Koreans or establish regulations for fit testing.g.
Lee Chang-Woo;Lee Young-Jae;Hyun Seong-Ho;Seong Jae-Man;Song Yun-Suk;Choi Don-Muk;Yoon Myung-O
Fire Science and Engineering
/
v.18
no.4
/
pp.16-21
/
2004
This paper has investigated influences of pollutants in air-breathing on the respirators and it by year of disused air respirators that fire fighter is using in domestic cutting done air respirators after collection observed state of cylinder material through instrumental analysis, and cut open pipe to confirm pollution degree of pipe from cylinder of air respirators to airline mask and confirm pollution availability. The metal surface inside the air respirators was corroded by moisture included in the compressed air. The material generated by corrosion is white powder of less then 100㎛, which is analyzed as aluminum hydroxide corroded by moisture. This aluminum hydroxide powder may get into the lung while one breathes in, and it is easy to be attached to the lung so it will cause a serious influences to human health. This study suggests that Korea should set out the standards for components and composition of breathing air as soon as possible.
This study is conducted to experiment on the performance test for 20 types of Filter-integrated Half-masks which could not only protect workers exposed to dusty environment, but also improve workability. Results and conclusions are as follows : 1) Respirators that removal efficiency of aerosols is 95 percent or more are 11 kinds(55%), and those who are 99.9 percent or more are 4 kinds(20%). Respirators that inhalation resistance is 4 mm in water or less are 13 kinds(65%), and those who are 6 mm in water or less are 17 kinds(85%). Respirators that efficiency of cumulative inhalation resistance is 100 percent or less are 11 kinds(55%) . 2) Respirators that resistance of moisture inhalation is 6 mm in water or less are 11 kinds(55%). and those who are 10 mm in water or less are 13 kinds(65cio), Respira'tors that ratio of removal efficiency for aerosols between dry and wet conditions is 95 percent or more are 9 kinds(45%). 3) Respirators which are not only 95 percent or more for removal efficiency of aersosls and 6 mm in water or less for inhalation resistance, but also 200 percent or less for efficiency of cumulative inhalation resistance, are 8 kinds(40%). Respirators which are not only 99.9 percent or more for removal efficiency and 6 mm in water or less for inhalation resistance, but also 100 percent or less for efficiency of cumulative inhalation resistance, are 3 kinds(15%). Respirators which are not only 95 percent or more for removal efficiency of aerosols and 6 mm in water or less for inhalation resistance, but also 200 percent or less for efficiency of cumulative inhalation resistance and 10 mm in water or less for resistance of moisture inhalation, are 6 kinds(30%) . 4) As standard rrlodel of artificial human head which would be perhaps different from the true one Is used to experiment fitness test, leakage rate is shown to be more or less high. However, artificial human head shall be accurately examined and follow-up studt. would be conducted in the future.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.11
no.2
/
pp.92-101
/
2001
This article reviewed previous studies on the 3D face recognition and anthropometric facial analysis to design suitable respirators for individuals. 3D facial anthropometric data have not been reported in Korea yet. With 3D facial data, it is possible to design and to manufacture respirators having more effective respirator-face seal and thus providing more comfortable wearing than donning of those respirators designed using 1 and 2-dimensional data. Also 3D data could be used for respirator fit-testing and selecting suitable respirator type and size by computer simulation without several steps of fit-test to each individual worker.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.7
no.1
/
pp.99-112
/
1997
A quantitative fit test, condensation nuclei counting(Portacount 8025, TSI), was performed concurrently with a qualitative fit test, sodium saccharin(FT-10, 3M) to evaluate FF values and to determine the correlation between two methods. Two brands of full facepieces, T, S and two brands of half masks, T, S, were fit tested, respectively, on 103 wearers one time. The FF values obtained by CNC QNFT were lognormally distributed. The FF values for T brand of respirators were statistically very much higher than those for S brand of respirators. For a full facepiece wearer combination having a $FF{\leq}100$, as determined by CNC QNFT, the point estimate of the probability of that combination not being rejected by the saccharin QLFT was found to be 0.09 with 90% confidence that this statistic is not expected to exceed 0.25. For a half mask wearer combination having a $FF{\leq}10$, as determined by CNC QNFT, the point estimate of the probability of that combination not being rejected by the saccharin QLFT was found to be 0.10 with 90%, confidence that this statistic is not expected to exceed 0.23. The uncertainty associated with each estimate, however, is large due to the small number of study subjects with inadequately fitting respirators. This result indicates that saccharin QLFT may be more suitable for adequately fitting respirators than inadequately fitting respirators.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.