• Title/Summary/Keyword: respectively identical components

Search Result 35, Processing Time 0.052 seconds

Congruent Triangles Sufficient and Insufficient Conditions Suggested Milestones for Inquiry and Discussion

  • Patkin, Dorit;Plaksin, Olga
    • Research in Mathematical Education
    • /
    • v.15 no.4
    • /
    • pp.327-340
    • /
    • 2011
  • In this paper we propose an inquiry task on the subject of congruent triangles. The task deals with conditions that are sufficient for congruency, and conditions that are insufficient. The aim of the task is to find the minimal number of identical components in two triangles that is sufficient to ensure congruency.

Design of component layout and tool path for machining multiple components

  • 이창근;임석철
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.610-614
    • /
    • 1996
  • In machining muliple components fixed on the same pallet of a NC machine, it is very important to minimize the total time required to finish the machining by carefully determining the component layout on the pallet, and the tool path of NC machine, and the sequence of tools to be used. In this paper, a linear integer programming model is presented to obtain an efficient layout; and a two-phased heuristic algorithm is proposed to minimize the total time for machining multiple components. Numerical examples are given for the case of identical components and nonidentical components, respectively. The result of either case shows significant reduction of 7.2~15.0% in the total time required to finish the machining.

  • PDF

Effect of Sex on Estimates of Genetic Parameters for Daily Gain and Ultrasonic Backfat Thickness in Swine

  • Hicks, C.;Satoh, M.;Ishii, K.;Kuroki, S.;Fujiwara, T.;Furukawa, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.5
    • /
    • pp.677-681
    • /
    • 1999
  • Estimates were made of genetic parameters for average daily gain (ADG) and average backfat thickness (ABF), and of the effect of sex on estimates of variance-covariance components for average daily gain of boars (DGM) and gilts (DGF) and average bacfat thickness of boars (BFM) and gilts (BFF) by residual maximum likelihood (REML) under a bivariate animal model. Data included a total of 2233 records (757 for boars and 1476 for gilts) of the Large White breed born between 1981 and 1986 in Miyazaki and Iwate prefectures in Japan. Heritability estimates for ADG and ABF were 0.43 and 0.69, respectively, with a genetic correlation of -0.08. Heritability estimates for DGM and DGF were 0.54 and 0.46, respectively, with a genetic correlation of 0.79, including that the two traits are influenced by similar but not identical genes. Respective estimates for BFM and BFF were 0.71 and 0.72 with a genetic correlation of 0.95, indicating that identical genes influence backfat thickness in boars and gilts.

Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study

  • Kim, Hee-Kyung
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.252-258
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the repeatability and matching accuracy between two identical intraoral spectrophotometers. MATERIALS AND METHODS. The maxillary right central incisor, canine, and mandibular left central incisor of each of 30 patients were measured using 2 identical intraoral spectrophotometers with different serial numbers (EasyShade V). The color of each shade tab from 3 shade guides (VITA 3D-Master) was also determined with both devices. All measurements were performed by a single operator. Statistical analyses were performed to verify the repeatability, accuracy, and the differences between the devices with paired t-tests, one-way ANOVA, and intra-class correlation coefficients (ICCs) (${\alpha}=.05$). RESULTS. A high level of measurement repeatability (ICC>0.90) among $L^*$, $a^*$, and $b^*$ color components was observed within and between devices (P<.001). Intra-device matching agreement rates were 80.00% and 81.11%, respectively, while inter-device matching agreement rate was 51.85%. ANOVA revealed no significant different color values within each device, while paired t-test provided significant different color values between both devices. The CIEDE2000 color differences between both devices were $2.28{\pm}1.61$ ${\Delta}E_{00}$ for in-vivo readings. Regarding the clinical matching accuracy of both devices, ${\Delta}E_{00}$ values between teeth and matching shade tabs were $3.05{\pm}1.19$ and $2.86{\pm}1.02$, respectively. CONCLUSION. Although two EasyShade V devices with different serial numbers show high repeatability of CIE $L^*$, $a^*$, and $b^*$ measurements, they could provide different color values and shade for the same tooth.

Seasonal Changes in Sexual Allocation within Flowers of Chelidonium majus ( Papaveraceae ) (애기똥풀 ( 양귀비과 ) 꽃에서 일어나는 성적자원 분배의 계절적 변화)

  • Kang, Hye-Son;Rihard B. Primark;Nam-Kee Chang
    • The Korean Journal of Ecology
    • /
    • v.14 no.4
    • /
    • pp.415-433
    • /
    • 1991
  • Seasonal variation in size and number of floral structures was examined in two massachusetts populations of chelidonium major, a self-compatible herb. All floral charcters except for anther number per flower declind significantly during a 3 week period. However, temporal patterns were not identical among characters or between popolations. The result indicate that floral characters varied in conjunction with flower diameter,but that the pattern of changes in floral characters in response to environments may not be easy to predict. Principal components analysis was conducted to environments may not be easy to predict. principal compenents analysis was conducted tl identify the functional relationship among floral male function, and female function, respectively, perhaps reflecting the functional distinction of floral characters. Based on this pattern, the relative allocation to sexual structures within flowers was examined: male allocation was relatively greater than female allocation eary or in the middle of flowering season, depending upon populations. Temporalvariation in relative allocation within flowers was not independent of seed tield components:; different combinations of the size and number of floral characters were correlated with different seed yield components, for example, either seed size or number per fruit, during a season. in particular, allocations to attractive and male structures were highly correlated with mean seed weight only earlier in the season. These result provide some evidence that flowering phenolgy is an important comportant to be considered in the study of sexual allocation.

  • PDF

Occurrence of Toxic Alexandrium and Intoxification of Two Mollusk Species by Paralytic Shellfish Poisoning Toxins on the Southeastern Coast of Korea

  • Kim Young-Soo;Lee Jong-Soo;Jang Joon-Ho;Kim Keun-Yong;Kim Chang-Hoon
    • Fisheries and Aquatic Sciences
    • /
    • v.8 no.2
    • /
    • pp.76-82
    • /
    • 2005
  • We analyzed the paralytic shellfish poisoning (PSP) toxins of the toxic marine dinoflagellate Alexandrium tamarense collected from Dadaepo and Gaduck-do in Busan and from Sujeong-ri in Jinhae Bay, Korea, in April 2003. We also analyzed the PSP toxin of mussels (Mytilus galloprovincialis) and oysters (Crassostrea gigas) collected around Busan and Jinhae Bay. PSP toxin analyses were conducted by high performance liquid chromatography (HPLC). Fifteen cultured A. tamarense isolates contained 2.78 to 57.47 fmol/cell, with nearly identical toxin profiles: major components C2, GTX4; minor components C1, GTX1, NEO; and trace components GTX2, GTX3, STX. PSP toxin contents were 0 to $492\;\mu{g}$ STXeq/100 g in mussels and 0 to $48\;\mu{g}$ STXeq/100 g in oysters. Mussels at Gijang and Sujeong-ri contained the most PSP toxin contents ($492\;\mu{g}\;STXeq/100\;g\;and\;252\;\mu{g}\;STXeq/100\;g,\;respectively$), exceeding the quarantine level ($80\;\mu{g}$ STXeq/100 g). Their dominant toxin components were C2, C1, GTX2, and GTX3; the minor components GTX1, GTX4, GTX5, and NEO were sporadically detected. Phytoplankton contained 0.774 fmol/L seawater and 1.228 fmol/L seawater at Gijang and Sujeong-ri in April. At that time, Alexandrium cells were present in the water column at Gijang at 2,577 cells/mL and at Sujeong-ri at 6,750 cells/mL. Overall, we found the high and similar PSP toxin contents in AZexandrium isolates and mussels, and a correlation between occurrence of toxic Alexandrium cells in the water column and mussel intoxification. High densities of toxic Alexandrium cells in the water column immediately preceded shellfish intoxification at Gijang and Sujeong-ri in April.

Instantaneous Power Compensation Theory in Three-phase Four-wire Systems (3상 4선 계통에서의 순시전력 보상이론)

  • Kim, Hyo-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.172-183
    • /
    • 2006
  • This paper analyzes instantaneous power compensation theory through comparing p-q theory and cross-vector theory which were proposed by Akagi and Nabae respectively in three-phase four-wire systems. The two compensation theories are identical when there is no zero-sequence voltage component in three-phase three-wire systems, However, when the zero-sequence voltage and/or current components exist in three-phase four-wire systems, the two compensation theories we different in definition on instantaneous real power and instantaneous imaginary power. Based on the analysis, this paper presents instantaneous power compensation method that can eliminate neutral current completely without using energy storage element when the zero-sequence current and voltage components exist in three-phase four-wire systems.

Assessment of steel structures designed for progressive collapse under localized fires

  • Behrouz Behnam
    • Steel and Composite Structures
    • /
    • v.46 no.2
    • /
    • pp.279-292
    • /
    • 2023
  • Structural design against the progressive collapse has been a vital necessity for decades due to occasional tragic events. The question of whether designed structures against the progressive collapse are still robust if subjected to multi-hazard scenarios containing column removal and successive localized fires is ad-dressed in the current study. Two seven-story steel structures with an identical area but different structural configurations of 4- and 5-bays are designed against the progressive collapse; the structural components are also fireproofed for a 60 min fire resistance. The structures are then subjected to different column re-moval scenarios over different stories followed immediately by localized fires. Results indicate that the structures are not able to keep their stability under all of the considered scenarios; the 4-bay structure is more vulnerable than the 5-bay structure. It is also indicated that upper stories are more sensitive toward the considered scenarios than lower stories. To advance structural safety, two strategies are adopted: in-creasing the thickness of the insulation materials to reduce the thermal effects, or, increasing the safety fac-tor (ΩN) of the structures when designing against the progressive collapse. As for the first strategy, provid-ing a 35% and a 25% increase in the insulation thicknesses of the structural components of the 4-bay and 5-bay structures, respectively, can prevent a progressive collapse to trigger. As for the second strategy, in-creasing ΩN by 10% can enhance the structural integrity to where no collapse occurs under all of the sce-narios.

Development of Surgical Two-wavelegth Nd:YAG Laser (수술용 2파장 펄스형 Nd:YAG 레이저 개발)

  • 윤길원;김홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF

Evaluation of Sampling Methodology for the Measurement of Polycyclic Aromatic Hydrocarbons in the Atmosphere (대기 중 다환방향족 탄화수소의 측정을 위한 시료포집방법의 비교평가)

  • 백성옥;최진수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.43-62
    • /
    • 1998
  • This study was carried out to investigate the influence of different sampling methods on the measured concentrations of polycyclic aromatic hydrocarbons (PAH) both in the vapor and particulate phases, and to evaluate the effects of ambient temperature and sampling duration on the losses of PAH associated with particle samples due to volatilization. The experimental protocol of this study is consisted of two parts. The first part is related to the comparison of PAH concentrations measured by 4 different sampling systems, each of which involves different sampling principles for comparison purposes, including a medium-volume sampler with XAD-2 adsorbent, a high-volume sampler with polyurethane foam (PUF), two identical low-volume samplers: one with XAD-2 and the other with PUF, respectively. The second part of this study is to quantitatively estimate the losses of particulate PAH samples by volatilization during sampling, using two identical low-volume samplers: one was used for changing the filters every 3 hrs, 6 hrs, 12 hrs, and 24 hrs sampling, while the other was maintained for continuous 48 hours sampling without changing the filter. The concentrations of volatile PAH including 2-3 rings appeared to be significantly affected by the type of adsorbent. Measured levels of these lower-molecular weight PAH by XAD-2 adsorbent were much higher than those by PUF for both high-volume and low-volume sampling. PUF was found to give rise to unknown components that interfered with the PAH analysis, even after extensive clean-up. In addition, the retention efficiency of PUF for lower molecular weight PAH was subject to a large variation, being significantly influenced by sampling conditions such as ambient temperature. However, the effect of sampling methods with different adsorbents on the measured levels of semi-volatile compounds including 4 rings PAH such as fluoranthene, pyrene, BaA and chrysene, was not so much significant as more volatile PAH compounds. It was also clear from this study that volatilization losses of the semi-volatile PAH collected on the filters were inevitably occurred during prolonged sampling, and hence the results obtained from conventional sampling methods may not be expected to yield an accurate distribution of PAH between the vapor and particulate phases.

  • PDF