• 제목/요약/키워드: resonance wavelength

검색결과 199건 처리시간 0.024초

Photoluminescent Graphene Oxide Microarray for Multiplex Heavy Metal Ion Analysis

  • Liu, Fei;Ha, Hyun Dong;Han, Dong Ju;Park, Min Su;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.281.2-281.2
    • /
    • 2013
  • Since heavy metal ions included in water or food resources have critical effects on human health, highly sensitive, rapid and selective analysis for heavy metal detection has been extensively explored by means of electrochemical, optical and colorimetric methods. For example, quantum dots (QDs), such as semiconductor QDs, have received enormous attention due to extraordinary optical properties including high fluorescence intensity and its narrow emission peaks, and have been utilized for heavy metal ion detection. However, the semiconductor QDs have a drawback of serious toxicity derived from cadmium, lead and other lethal elements, thereby limiting its application in the environmental screening system. On the other hand, Graphene oxide (GO) has proven its superlative properties of biocompatibility, unique photoluminescence (PL), good quenching efficiency and facile surface modification. Recently, the size of GO was controlled to a few nanometers, enhancing its optical properties to be applied for biological or chemical sensors. Interestingly, the presence of various oxygenous functional groups of GO contributes to opening the band gap of graphene, resulting in a unique PL emission pattern, and the control of the sp2 domain in the sp3 matrix of GO can tune the PL intensity as well as the PL emission wavelength. Herein, we reported a photoluminescent GO array on which heavy metal ion-specific DNA aptamers were immobilized, and sensitive and multiplex heavy metal ion detection was performed utilizing fluorescence resonance energy transfer (FRET) between the photoluminescent monolayered GO and the captured metal ion.

  • PDF

금속선의 주기적인 배열을 이용하여 기계적으로 형성한 파장 가변 장주기 광섬유 격자 (Tunable Mechanically Formed Long-Period Fiber Gratings using Periodically Arrayed Metal Wires)

  • 손경락;김광택
    • 한국광학회지
    • /
    • 제16권5호
    • /
    • pp.401-405
    • /
    • 2005
  • 본 논문에서는 $250{\mu}m$ 직경의 황동선을 주기적으로 배열하여 기계적으로 형성한 장주기 광섬유 격자를 제안하였으며 전류제어로 파장가변 기능을 구현하였다. 광섬유 클래딩을 감싸고 있는 물질의 굴절률 변화가 공진파장의 함수임을 이용하여 클래딩 주위에 도포된 물질의 열 광학 계수가 금속선에 인가된 전력에 의해 제어되도록 함으로서 파장가변을 유도하였으며 주어진 파장 영역내에서 인가전력에 대한 공진파장의 가변 정도를 조사하였다. 글리세린의 열광학 효과를 이용한 경우 20 W 인가전력에 대하여 $LP_{03}$ 모드는 14nm, $LP_{04}$ 모드는 48 nm 정도의 파장가변이 가능함을 확인하였고, 단일모드 광섬유에 대한 기하 광학적 근사방법을 적용하여 해석한 결과와 잘 일치함을 보였다.

이차전지로 구동하기 위한 다른 발진 특성을 나타내는 조명용 광양자테 소자 개발 (Development of Photonic Quantum Ring Device with Different Oscillation Characteristics for Driving with Secondary Battery)

  • 김경보;이종필;김무진
    • 디지털융복합연구
    • /
    • 제19권11호
    • /
    • pp.341-349
    • /
    • 2021
  • 최근 조명 산업이 중요한 분야로 인식되면서 PQR (Photonic Quantum Ring) 소자는 LED(Light Emitting Diode)를 대체할 수 있는 차세대 광원이 될 전망이다. 본 연구에서는 기존 연구와 유사한 결과를 검증하고, 소자의 광특성을 분석하기 위해 광섬유가 연결된 스테이지에 x, y, z 좌표를 입력하면 자동으로 이동하며, 또한, 소자에 광섬유를 근접시키는 NSOM (Near field scanning optical microscopy) 장치를 추가한 측정 시스템을 이용하여 소자의 광특성 실험과 공진 및 어레이 소자의 광특성 시뮬레이션을 통해 조명용 소자로 가능성을 검증하고자 하였다. 이를 위해 메사와 홀 형태가 동시에 존재하는 메사 직경 40㎛, 홀 직경 3㎛의 소자를 제작하여 소자의 근접장으로 PQR 소자는 ㎂에서 동작하며, 메사와 홀 소자는 서로 독립적으로 구동됨을 관찰하였다. 위치에 따른 소자의 광파장 스펙트럼을 측정하여 메사와 홀 소자에 의한 커플링 현상을 처음으로 확인하였다.

격자 구조형 스트립 방향성 결합기에 기초한 광 바이오-센서의 고 민감도 분석 (High Sensitivity Analysis of Optical Bio-Sensor based on Grating-Assisted Strip Directional Coupler)

  • 호광춘
    • 한국인터넷방송통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.157-162
    • /
    • 2023
  • 격자 구조형 스트립 방향성 결합기를 기반으로 한 고 민감도 굴절률 bio-sensor를 제안하였다. 그 센서는 도파관 중 하나의 상단 층에 격자 구조가 구성된, 두 개의 비대칭 스트립 도파관을 사용하여 설계하였다. 위상정합 조건을 만족하는 공진 파장에서 한 도파관으로부터 다른 도파관으로 최대 광 결합이 발생하며, 도파관 표면 영역에 놓인 분석물질의 굴절률 변화에 따른 위상정합 조건의 변화가 민감도를 측정하는 척도로 사용될 수 있음을 보여주었다. 제안된 센서는 높은 굴절률 민감도를 가진 on-chip 장치로 설계될 수 있으며, 낮은 전파 손실을 제공하여 민감도가 향상되도록 센서를 구성되었다. 더욱이, 도파관 파라미터에 따른 민감도 변화가 센서의 설계 최적화를 위하여 분석되었다.

메타 물질 기법을 이용한 전방향성 복사 패턴을 갖는 평면형 S-DMB 안테나 설계 및 구현 (Design and Implementation of Plannar S-DMB Antenna with Omni-Directional Radiation Pattern Using Metamaterial Technique)

  • 안찬규;유주봉;전준호;김우찬;양운근;나병구;이재호
    • 한국전자파학회논문지
    • /
    • 제21권12호
    • /
    • pp.1343-1351
    • /
    • 2010
  • 본 논문에서는 metamaterial CRLH(Composite Right- and Left-Handed) 구조 기반의 새로운 패치 안테나를 설계 제작하여 측정하였다. 일반 마이크로스트립 패치 구조의 기본 공진 모드인 반파장 공진이나 반파장 공진의 양의 정수배와 달리 제안된 안테나는 구조 전체에 전계가 같은 위상을 갖게 한다. 본 논문에서 제안하는 안테나는 요구되는, $\lambda/4$ 모노폴 안테나의 전형적인 특성인 전방향 패턴을 갖는 동시에 low-profile의 장점을 가진다. 제안된 안테나의 전산 모의 실험에는 Ansoft사의 FEM(Finite Element Method) 방식의 HFSS(High Frequency Structure Simulator)를 사용하였다. 제안된 안테나는 두께 1.6 mm, 유전율 4.4의 FR-4 기판을 사용하여 제작하였다. 구현된 안테나는 S-DMB(Satellite-Digital Multimedia Broadcasting) 서비스에서 사용되는 2.63~2.655 GHz에서 VSWR(Voltage Standarding Wave Ratio)$\leq$2임을 만족하며, 측정된 최대 이득과 효율은 각각 2.65 dBi와 81.14 %이다.

A study on the Frequency Analysis Function of the Auricle Using A Notch Filter

  • Park, Dong-Cheol
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.241-255
    • /
    • 2021
  • The human auricle is the first part to receive sound from the outside. In this part, the frequency range of human recognizable form is divided and organized. In this study, we propose modeling by applying a single sound source to the surface of the human auricle. This means that when the sound pressure of a low frequency (low frequency) sound enters the pinna, the impedance felt at the tip of a part of the non-linear surface of the pinna is mainly due to the tensile force at the end of the part of the non-linear surface of the pinna. By expressing the situation of moving at a very small speed, the characteristic impedance of the pinna was confirmed to be negative infinity, and it was also confirmed that the speed at the tip of a part of the non-linear surface of the pinna was 0 in the anti-resonance state. It was found that the wave propagation phenomenon that determines the characteristics of the filter is determined by how large the wavelength, kL, is compared to the length of the tip of a part of the non-straight surface of the pinna. Humans first receive sounds from outside through their ears. The auricle is non-linear and has a curved shape, and it is known that it analyzes frequencies while receiving external sounds. The human ear has an audible frequency range of 20Hz - 20,000Hz. Through the study, we applied the characteristics of the notch filter to hypothesize that the human audible frequency range is separated from the auricle, and applied filter theory to analyze it, and as a result, meaningful results were obtained. The curved part and the inner part of the auricle function as a trumpet, collecting sounds, and at the same time amplifying the weak sound of a specific band. The point was found and the shape of the envelope detected in the auricle was found. Selectivity for selecting sounds coming from the outside is the formula of the pinna that implements the function of Q. The function of distinguishing human-recognizable sound from the pinna from low to high through frequency analysis is performed in the pinna, and the 2-3kHz area, where human hearing threshold is the most sensitive, is also the acoustic impedance of the most recessed area of the pinna. It can be seen that starting from.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

반응가스조성이 PET기판위에 ECR 화학증착법에 의해 제조된 SnO2 박막특성에 미치는 영향 (Reaction Gas Composition Dependence on the Properties of SnO2 Films on PET Substrate by ECR-MOCVD)

  • 김연석;이중기
    • 전기화학회지
    • /
    • 제8권3호
    • /
    • pp.139-145
    • /
    • 2005
  • 전자싸이크로트론공명(ECR: Electro Cyclotron Resonance)상온화학증착법에 의해 PET 폴리머기판위에 $SnO_x$ 박막을 제조하고, Sn의 전구체인 TMT(Tetra-methyl Tin)에 대한 산소와 수소의 몰 비 변화가 박막의 특성에 미치는 영향을 조사하였다 비화학양론적인 결합에 의해 성장된 투명 주석 산화막은 주입되는 산소/TMT, 수소/TMT몰 비에 의하여 조성비가 결정되고, 결정된 조성비에 의해 전기적 성질이 결정되는 것을 확인할 수 있었다. 산소/TMT의 몰 비 변화에 대하여 PET(polyethylene terephthalate)에 증착된 $SnO_x$ 박막의 최적 조성비는 1:2.4이다. 조성비는 반응에 참가하는 산소의 양이 증가할수록 점차적으로 증가하고, 과량의 몰 비로 산소가 주입될 경우 박막내의 Sn과 결합하지 않고 잉여 산소전하밀도를 증가시켜 bulk한 박막을 형성해 전기 비저항을 증가시키는 주요 원인이 된다. 수소/TMT의 몰 비는 산소 몰 비와 같이 증착되는 $SnO_x$의 몰 비에 영향을 주어 조성비를 변화시킴으로서 전기비저항을 결정하는데 크게 기여한다. 반응기내에 공급되는 수소량이 적으면 TMT의 불완전한 분해를 초래하여 반응에 필요한 $Sn^+$ 이온농도가 낮아지게 되고,상대적으로 잉여 산소함량이 증가하면서 높은 저항을 나타낸다. 임계값 이상으로 많은 양의 수소를 공급하면 플라즈마 내에 존재하는 $O^-$ 이온을 환원시켜 주석 산화막의 형성에 필요한 $O^-$ 이온의 감소로 전기저항이 오히려 증가하게 된다. 따라서 박막의 Sn:O의 조성비는 주입되는 산소량이 증가할수록 더욱 큰 값을 갖게 되고, 주입되는 수소량이 증가할수록 작은 값을 갖게 된다. 본 연구범위에서 TMP에 대한 산소의 몰 비는 80배, 수소의 몰 비는 40배일 때 가장 투명도와 전기전도도를 지니는 박막 특성을 나타내었다.

본초 광물로서의 활용을 위한 산지별 전기석의 광물학적 연구 (Mineralogical Studies of the Tourmaline for Medicinal Applications by Production Localities)

  • ;김선옥;박희율;박맹언
    • 자원환경지질
    • /
    • 제51권4호
    • /
    • pp.345-358
    • /
    • 2018
  • 이 연구는 전기석이 본초 광물의 활용 가능성을 평가하기 위하여 중국 산동성 흑색 전기석 5종, 브라질 미나스 제라이스(Minas Geraris)광산의 흑색 및 핑크색 전기석 2종, 한국 대유광산 흑색 전기석 1종을 대상으로 전자탐침미세분석, X-선 회절분석, 유도결합플라스마 분광방출분석, 퓨리에변환 적외선분광분석, 원적외선 분석, 핵자기공명분석 및 물-전기석 반응에 따른 pH-DO 변화를 수행하였다. 또한, 전기석 찜질방의 온열효과와 전기석 분말을 첨가한 비누가 피부에 미치는 영향을 검토하였다. 연구에 사용된 전기석 시료들은 철과 알루미늄 및 붕소 함량이 높은 유형으로 분류되며, 칼슘, 나트륨, 칼륨, 철과 붕소 함량변화는 전기석의 고용체 특성을 반영한다. $CaO/(CaO+Na_2O)$와 MgO/(FeO+MgO) 함량비는 높은 정(+)의 상관관계를 갖는다. 전기석 분말과 증류수와의 반응에서 DO값은 반응시간의 경과에 따라 낮아지며, DO=10에서 안정된다. pH는 6시간까지 증가되고, 24시간 이후에는 대체적으로 pH=8에서 안정된 상태를 유지한다. 전기석은 단파장에서 흡수 스펙트럼의 강도와 투과율이 낮아지며, 흡수 스펙트럼의 파장과 강도는 구성 원소의 함량과 결정학적 특징에 따라 달라진다. 특히, 철의 함량증가는 방사량을 감소시키는 원인이 되는 것으로 확인되었다. 전기석의 철 함량과 원적외선 방사량의 상관관계는 높은 정(+)의 상관성을 가지며, 알루미늄과 마그네슘 함량은 부(-)의 상관관계를 나타낸다. 증류수와 전기석 분말의 반응은 $^{17}O-NMR$ 반치폭을 감소시키는 것으로 확인되었다. 전기석에 의한 고온 찜질방(약 $100^{\circ}C$ 사우나)에서의 온열효과는 체온을 $0.5-1.5^{\circ}C$ 정도 높이며, 맥박은 평균 12회, 혈압은 10mg Hg 상승한다. 전기석 비누는 피부에 매우 좋은 효과를 나타내며, 알레르기와 아토피 등의 문제성 피부에서 보통이상의 개선 효과를 갖는 것으로 확인되었다.