• 제목/요약/키워드: resonance reduction

검색결과 566건 처리시간 0.025초

Management of Unilateral Facet Dislocation of the Cervical Spine

  • Baek, Geum-Seong;Lee, Woo-Jong;Koh, Eun-Jeong;Choi, Ha-Young;Eun, Jong-Pil
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권5호
    • /
    • pp.295-300
    • /
    • 2007
  • Objective : Unilateral facet dislocation of the cervical spine occurs by flexion and rotation injuries and cannot be easily reduced by axial traction. We analyzed 14 consecutive patients with unilateral facet dislocation of the cervical spine to increase knowledge about anatomical reduction of locked facet and factors for successful reduction. Methods : Fourteen patients [10 men and 4 women] with unilateral facet dislocation of the cervical spine were retrospectively analyzed. Plain X-ray, computerized tomography scan, and magnetic resonance imaging were performed. All patients underwent manual reduction and surgery with anterior interbody fusion and plate fixation. The manual reduction was performed by neck flexion and rotation to the opposite side of dislocation, followed by rotation and flexion of the head toward the side of dislocation and extension with relaxation of traction. Mean follow-up period was 17 months. The level of spine, amount of subluxation, combined facet fracture, and time from injury to initial reduction were analyzed using the data obtained from medical records. Results : Thirteen [93%] patients were reduced successfully. Immediate reduction was achieved in 7 patients but failed in 7 patients. Seven patients underwent delayed closed reduction under general anesthesia, and successful reduction was achieved in 6 patients. Only one patient with bone chips between articular facets failed to achieve anatomical reduction. Conclusion : In order to reduce the locked facet more easily and safely, we recommend manipulative traction with anterior interbody fusion and plate fixation under general anesthesia after being aware of spinal cord injury with magnetic resonance imaging.

An Optimal Damping Control Algorithm of Direct Two-level Inverter for Miniaturization and Weight Reduction of Auxiliary Power Supply on Railway Vehicle

  • Lee, Chang-hee;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2335-2343
    • /
    • 2018
  • This paper proposes an optimal damping control algorithm of the DTI (Direct Two-level Inverter) to miniaturize and reduce the weight of auxiliary power supply for railway vehicles. The conventional auxiliary power supply for railway vehicles uses a DC-DC converter to maintain the inverter input power from the line voltage smoothly. The proposed topology does not use a DC-DC converter for reducing of manufacturing and maintenance costs. It also proposes a DTI topology removed damping resistors that generate ground signal noise in a certain period. At this time, a resonance phenomenon of DC-link voltage occurs due to variation of the inductive load, and a method of controlling the resonance phenomenon of DC-link voltage is required. In order to suppress the resonance phenomenon of the DC-link voltage, at a point before resonance occurs, this paper introduces an algorithm to suppress the resonance phenomenon of DC-link voltage by compensating the resonance component of the q axis voltage of the synchronous reference frame. The proposed algorithm verifies the effect through simulation and experiment.

공조용 압축기의 Cavity Resonance의 측정 및 저감에 관한 연구 (A Study on Measurement and Reduction of Cavity Resonance Based on the Internal Acoustic Modeling of Compressor)

  • 안병하
    • 동력기계공학회지
    • /
    • 제3권2호
    • /
    • pp.26-33
    • /
    • 1999
  • Pressure pulsation Inside the discharge and suction cavity of rotary and scroll compressor are often a major source of objectionable noise and vibration. The key factor of these noise and vibration is due to the cavity resonance. It is not only necessary to understanding the characteristics of pulsation in order to reduce the excitation force of gas to the cavity but also to verifying the phenomena of cavity resonance. For the purpose of these understandings, measurement and simulation of cavity resonance can lead to a better understandings how they occur and be very important to identify the ways to reduce the noise efficiently. In this paper, modeling of the cavity(internal acoustics inside the shell) is discussed and simulated using FEM. Results from the simulation are compared with those measurement in experiments. In describing of cavity mode by experiments, it is very important to specify the exact conditions under which they are measured. Finally, this paper shows the one example of reduced cavity resonance in the compressor.

  • PDF

Dynamic numerical analysis of single-support modular bridge expansion joints

  • Yuan, Xinzhe;Li, Ruiqi;Wang, Jian'guo;Yuan, Wancheng
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.1-12
    • /
    • 2016
  • Severe fatigue and noise problems of modular bridge expansion joints (MBEJs) are often induced by vehicle loads. However, the dynamic characteristics of single-support MBEJs have yet to be further investigated. To better understand the vibration mechanism of single-support MBEJs under vehicle loads, a 3D finite element model of single-support MBEJ with five center beams is built. Successive vehicle loads are given out and the vertical dynamic responses of each center beams are analyzed under the successive loads. Dynamic amplification factors (DAFs) are also calculated along with increasing vehicle velocities from 20 km/h to 120 km/h with an interval 20 km/h. The research reveals the vibration mechanism of the single-support MBEJs considering coupled center beam resonance, which shows that dynamic responses of a given center beam will be influenced by the neighboring center beams due to their rebound after the vehicle wheels depart. Maximal DAF 1.5 appears at 120 km/h on the second center beam. The research results can be utilized for reference in the design, operation and maintenance of single-support MBEJs.

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

KTX용 2경간 연속교량의 동적거동 및 공진감소 (Dynamic Behavior and Resonance Reduction of Two-Span Continuous Bridges for Korean Train eXpress)

  • 오주원
    • 대한토목학회논문집
    • /
    • 제28권1A호
    • /
    • pp.95-104
    • /
    • 2008
  • 본 연구에서는 경부고속철도상의 대표적인 교량인 2경간 연속보 형태의 고속철도 교량에 대하여 동적거동을 해석하고 공진발생의 감소방안들을 제시하였다. 하중은 한국형 고속철도하중인 총길이 380.15 m의 TGV-K 열차(2P+18T)가 일정한 속도로 이동하는 것으로 하였다. 동적거동을 모사하는 지배방정식은 질량과 강성이 분포된 연속계에서 만들어진 편미분방정식을 이용하여 구하였으며 Duhamel 적분을 이용한 모달계수의 처리를 수반하는 모드중첩법을 이용하여 동적해석을 수행하였다. 열차의 주행속도에 관계없이 동적거동을 급격히 감소시킬 수 있는 지간장이 존재하였으며 지금까지 연구된 단순보 형태의 교량에서 분석된 결과와는 달랐다. 열차의 주행속도에 의존하여 동적응답이 급격히 증가되어 공진현상을 일으키는 경우에도 공진을 감소시킬 수 있는 여러 방안들을 제시하였다.

흡음형과 공명형 덕트 소음기의 소음저감 성능에 관한 실험적 고찰 (An Experimental Investigation on Noise Reduction Performance of the Absorption and the Resonance Type Duct Silencers)

  • 이영섭;정광섭;이동훈
    • 설비공학논문집
    • /
    • 제22권12호
    • /
    • pp.897-901
    • /
    • 2010
  • A silencer has been widely used for the purpose of suppressing the noises propagated from duct of air conditioning system. The absorption type silencer is usually applied to reduce the noise with high frequency bandwidth. On the order hand, the resonance type silencer is applied to reduce the noise with low-middle frequency bandwidth. The insertion loss of silencer is measured in the reverberation room. The cut-off frequency of reverberation room is 100 Hz. The insertion loss of absorption type silencer is more larger than that for resonance type silencer regardless of changing the flow velocity.

Resonance of a rectangular plate influenced by sequential moving masses

  • Hassanabadi, Mohsen Ebrahimzadeh;Attari, Nader K.A.;Nikkhoo, Ali;Mariani, Stefano
    • Coupled systems mechanics
    • /
    • 제5권1호
    • /
    • pp.87-100
    • /
    • 2016
  • In this work, an improved semi-analytical technique is adopted to track the dynamic response of thin rectangular plates excited by sequential traveling masses. This technique exploits a so-called indirect definition of inertial interaction between the moving masses and the plate and leads to a reduction, in the equations of motion, of the number of time-varying coefficients linked to the changing position of the masses. By employing this optimized method, the resonance of the plate can be obtained according to a parametric study of relevant maximum dynamic amplification factor. For the case of evenly spaced, equal masses travelling along a straight line, the resonance velocity of the masses themselves is also approximately predicted via a fast methodology based on the fundamental frequency of the system only.

Sensitivity and vibration reduction of buffeting induced resonance of hangers

  • Zhang, Zhitian;Zhang, Weifeng
    • Wind and Structures
    • /
    • 제25권1호
    • /
    • pp.39-61
    • /
    • 2017
  • Buffeting induced resonance (BIR) of hangers on long-suspension bridges is briefly reviewed, including mechanism and experimental verification. Taken the Xihoumen suspension bridge as a numerical example, sensitivities of the BIR of hangers to wind properties are investigated, including types of wind spectrum, turbulence intensity, and spacial coherence of wind fluctuations. Numerical simulations indicate that the BIR of hangers occur to both cases of different wind spectra, showing that it is insensitive to types of wind spectrum. On the other hand, it is found that the turbulence intensity affects buffeting of main cables almost in a linear manner, and so it does to the BIR of the hangers; however, the resonance factors, namely the ratio of the response of the hanger to that of the main cable, are little affected by the turbulence intensity. The spacial coherence of the wind fluctuations, although plays an important role on the buffeting responses of the main structure, has no substantial effects on the BIR of the hangers. Finally, replacement of steel strand with CFRP material has been verified as a very effective countermeasure against the BIR of hangers.