• Title/Summary/Keyword: resonance ratio control

Search Result 93, Processing Time 0.03 seconds

Cerebral Hemodynamic Analysis in Pediatric Moyamoya Patients using Perfusion Weighted MRI (관류 강조 자기공명 영상을 이용한 소아 모야모야 환아의 뇌 혈역학 분석)

  • Chang, Won-Seok;Kim, Tae-Gon;Lee, Seung-Koo;Choi, Jung-Uhn;Kim, Dong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.207-212
    • /
    • 2005
  • Objective: Classically, single photon emission tomography is known to be the reference standard for evaluating the hemodynamic status of patients with moyamoya disease. Recently, T2-weighted perfusion magnetic resonance(MR) imaging has been found to be effective in estimating cerebral hemodynamics in moyamoya disease. We aim to assess the utility of perfusion-weighted MR imaging for evaluating hemodynamic status of moyamoya disease. Methods: The subjects were fourteen moyamoya patients(mean age: 7.21 yrs) who were admitted at our hospital between Sep. 2001 to Sep 2003. Four normal children were used for control group. Perfusion MR imaging was performed before any treatment by using a T2-weighted contrast material-enhanced technique. Relative cerebral blood volume(rCBV) and time to peak enhancement(TTP) maps were calculated. Relative ratios of rCBV and TTP in the anterior cerebral artery(ACA), middle cerebral artery(MCA) and basal ganglia were measured and compared with those of the posterior cerebral artery(PCA) in each cerebral hemispheres. Using this data, we analysed the hemodynamic aspect of pediatric moyamoya disease patients in regarding to the age, Suzuki stage, signal change in FLAIR MR imaging, and hemispheres inducing symptoms. Results: The mean rCBV ratio of ACA, MCA did not differ between normal children and moyamoya patients. However the significant TTP delay was observed at ACA, MCA territories (mean = 2.3071 sec, 1.2089 see, respectively, p < 0.0001). As the Suzuki stage of patients is advanced, rCBV ratio is decreased and TTP differences increased. Conclusion: Perfusion MR can be applied for evaluating preoperative cerebral hemodynamic status of moyamoya patients. Furthermore, perfusion MR imaging can be used for determine which hemisphere should be treated, first.

Quantitative MRI Assessment of Pancreatic Steatosis Using Proton Density Fat Fraction in Pediatric Obesity

  • Jisoo Kim;Salman S. Albakheet;Kyunghwa Han;Haesung Yoon;Mi-Jung Lee;Hong Koh;Seung Kim;Junghwan Suh;Seok Joo Han;Kyong Ihn;Hyun Joo Shin
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1886-1893
    • /
    • 2021
  • Objective: To assess the feasibility of quantitatively assessing pancreatic steatosis using magnetic resonance imaging (MRI) and its correlation with obesity and metabolic risk factors in pediatric patients. Materials and Methods: Pediatric patients (≤ 18 years) who underwent liver fat quantification MRI between January 2016 and June 2019 were retrospectively included and divided into the obesity and control groups. Pancreatic proton density fat fraction (P-PDFF) was measured as the average value for three circular regions of interest (ROIs) drawn in the pancreatic head, body, and tail. Age, weight, laboratory results, and mean liver MRI values including liver PDFF (L-PDFF), stiffness on MR elastography, and T2* values were assessed for their correlation with P-PDFF using linear regression analysis. The associations between P-PDFF and metabolic risk factors, including obesity, hypertension, diabetes mellitus (DM), and dyslipidemia, were assessed using logistic regression analysis. Results: A total of 172 patients (male:female = 125:47; mean ± standard deviation [SD], 13.2 ± 3.1 years) were included. The mean P-PDFF was significantly higher in the obesity group than in the control group (mean ± SD, 4.2 ± 2.5% vs. 3.4 ± 2.4%; p = 0.037). L-PDFF and liver stiffness values showed no significant correlation with P-PDFF (p = 0.235 and p = 0.567, respectively). P-PDFF was significantly associated with obesity (odds ratio 1.146, 95% confidence interval 1.006-1.307, p = 0.041), but there was no significant association with hypertension, DM, and dyslipidemia. Conclusion: MRI can be used to quantitatively measure pancreatic steatosis in children. P-PDFF is significantly associated with obesity in pediatric patients.

Improved Current Source Design to Measure Induced Magnetic Flux Density Distributions in MREIT

  • Oh Tong-In;Cho Young;Hwang Yeon-Kyung;Oh Suk-Hoon;Woo Eung-Je;Lee Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.1
    • /
    • pp.30-37
    • /
    • 2006
  • Injecting currents into an electrically conducting subject, we may measure the induced magnetic flux density distributions using an MRI scanner. The measured data are utilized to reconstruct cross-sectional images of internal conductivity and current density distributions in Magnetic Resonance Electrical Impedance Tomography (MREIT). Injection currents are usually provided in a form of mono-polar or bi-polar pulses synchronized with an MR pulse sequence. Given an MRI scanner performing the MR phase imaging to extract the induced magnetic flux density data, the current source becomes one of the key parts determining the signal-to-noise ratio (SNR) of the measured data. Since this SNR is crucial in determining the quality of reconstructed MREIT images, special care must be given in the design and implementation of the current source. This paper describes a current source design for MREIT with features including interleaved current injection, arbitrary current waveform, electrode switching to discharge any stored charge from previous current injections, optical isolation from an MR spectrometer and PC, precise current injection timing control synchronized with any MR pulse sequence, and versatile PC control program. The performance of the current source was verified using a 3T MRI scanner and saline phantoms.

The Prevalence of Cerebral Microbleeds in Non-Demented Parkinson's Disease Patients

  • Kim, Kyeong Joon;Bae, Yun Jung;Kim, Jong-Min;Kim, Beom Joon;Oh, Eung Seok;Yun, Ji Young;Kim, Ji Seon;Kim, Han-Joon
    • Journal of Korean Medical Science
    • /
    • v.33 no.46
    • /
    • pp.289.1-289.10
    • /
    • 2018
  • Background: Cerebral microbleeds (CMBs) are associated with cerebrovascular risk factors and cognitive dysfunction among patients with Parkinson's disease (PD). However, whether CMBs themselves are associated with PD is to be elucidated. Methods: We analyzed the presence of CMBs using 3-Tesla brain magnetic resonance imaging in non-demented patients with PD and in age-, sex-, and hypertension-matched control subjects. PD patients were classified according to their motor subtypes: tremor-dominant, intermediate, and postural instability-gait disturbance (PIGD). Other cerebrovascular risk factors and small vessel disease (SVD) burdens were also evaluated. Results: Two-hundred and five patients with PD and 205 control subjects were included. The prevalence of CMBs was higher in PD patients than in controls (16.1% vs. 8.8%; odds ratio [OR], 2.126; P = 0.019); CMBs in the lobar area showed a significant difference between PD patients and controls (11.7% vs. 5.9%; OR, 2.234; P = 0.032). According to the motor subtype, CMBs in those with PIGD type showed significant difference from controls with respect to the overall brain area (21.1% vs. 8.9%; OR, 2.759; P = 0.010) and lobar area (14.6% vs. 4.9%; OR, 3.336; P = 0.016). Among PD patients, those with CMBs had higher age and more evidence of SVDs than those without CMBs. Conclusion: We found that CMBs are more frequent in PD patients than in controls, especially in those with the PIGD subtype and CMBs on the lobar area. Further study investigating the pathogenetic significance of CMBs is required.

Development of MRI Phantom for Assessing MR Image Quality (자기공명영상 화질 평가용 팬텀 개발에 관한 연구)

  • Ahn, Chang-Beom;Na, Dong-Gyu;Kim, Kwang-Gi;Kim, Dong-Sung;Kim, In-Su;Lee, Jung-Whee;Hong, Suk-Joo;Byun, Jae-Ho;Khang, Hyun-Soo;Jang, Gi-Won;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • Purpose : To evaluate MR image qualities we developed a new MRI phantom with the fixation structures necessary to position it into coil firmly. Materials and methods : We designed MRI phantom for eight evaluation items such as slice thickness accuracy, high contrast spatial resolution, low contrast object detectability, geometry accuracy, slice position accuracy, image intensity uniformity, percent signal ghosting and signal to noise ratio. For the positioning of phantom at coils, the fixation structures were set up on the surface of phantom. Six different MRI units were used for test the possibility for the clinical application and their image qualities were evaluated. Results : We acquired appropriate MR image qualities enough for the evaluation on all used MR units and confirmed that their evaluations were within reliable values compared to real ones for some items. The positioning of our phantom into head coils with fixation structures worked well for proper imaging. Conclusion : We found that our prototype of MRI phantom had the possibility of clinical application for MR image quality assessment.

  • PDF

Effect of the Neutral Beam Energy on Low Temperature Silicon Oxide Thin Film Grown by Neutral Beam Assisted Chemical Vapor Deposition

  • So, Hyun-Wook;Lee, Dong-Hyeok;Jang, Jin-Nyoung;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.253-253
    • /
    • 2012
  • Low temperature SiOx film process has being required for both silicon and oxide (IGZO) based low temperature thin film transistor (TFT) for application of flexible display. In recent decades, from low density and high pressure such as capacitively coupled plasma (CCP) type plasma enhanced chemical vapor deposition (PECVD) to the high density plasma and low pressure such as inductively coupled plasma (ICP) and electron cyclotron resonance (ECR) have been used to researching to obtain high quality silicon oxide (SiOx) thin film at low temperature. However, these plasma deposition devices have limitation of controllability of process condition because process parameters of plasma deposition such as RF power, working pressure and gas ratio influence each other on plasma conditions which non-leanly influence depositing thin film. In compared to these plasma deposition devices, neutral beam assisted chemical vapor deposition (NBaCVD) has advantage of independence of control parameters. The energy of neutral beam (NB) can be controlled independently of other process conditions. In this manner, we obtained NB dependent high crystallized intrinsic and doped silicon thin film at low temperature in our another papers. We examine the properties of the low temperature processed silicon oxide thin films which are fabricated by the NBaCVD. NBaCVD deposition system consists of the internal inductively coupled plasma (ICP) antenna and the reflector. Internal ICP antenna generates high density plasma and reflector generates NB by auger recombination of ions at the surface of metal reflector. During deposition of silicon oxide thin film by using the NBaCVD process with a tungsten reflector, the energetic Neutral Beam (NB) that controlled by the reflector bias believed to help surface reaction. Electrical and structural properties of the silicon oxide are changed by the reflector bias, effectively. We measured the breakdown field and structure property of the Si oxide thin film by analysis of I-V, C-V and FTIR measurement.

  • PDF

Preliminary Design of ECR Ion Thruster (ECR 방식 이온추력기 기본 설계)

  • Kim, Su-Kyum;Yu, Myoung-Jong;Choi, Seung-Woon
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.14-21
    • /
    • 2010
  • Ion thruster is a kind of electrostatic thruster that use electrostatic field in order to accelerate ionized propellant. Ion thruster have characteristics of small thrust but very high specific impulse among the electric thrusters. High specific impulse can reduce propellant consumption significantly. So, ion thruster have advantage for long time and long distance mission. Recently, plans for space exploration is increasing gradually not only at traditional forward countries for space like USA, Russia and Europe, but also other countries like Japan, China and India. Exploration for superior planets and asteroids the propellant ratio can go up to about 99% when chemical propulsion is used as a cruising thruster. Therefore, latest space exploration vehicles use the ion thruster as main thruster for del-V burn and use monopropellant thrusters for attitude control. In this paper, the development process of preliminary ECR ion thruster and the ECR discharge test results will be presented.

Acoustic and Stroboscopic Characteristics of Normal Person's Voices with Advancing Age (연령증가에 따른 정상 노인의 음향분석학적 특징)

  • 진성민;권기환;강현국
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.44-48
    • /
    • 1997
  • Anatomic and physiological changes of the larynx with advancing age result in morphologic changes of the vocal fold and reduced control of the phonatory mechanism in elderly individuals and are reflected in increased unstability of fundamental frequency (Fo). The purpose of this study is to increase current understanding of acoustic and stroboscopic characteristics of normal elderly persons voices. First, phonated /a/ vowel productions by 40 normal adults (20 to 40 years, 20 men and 20 women) and 40 normal elderly persons (60 to 80 years,20 men and 20 women) were analyzed, using CSL (model 4300B) acoustic analysis software, to obtain acoustic measures related to fundamental frequency stability nd vocal resonance characteristics. Second, stroboscopic images of the vocal fold behavior in all subjects were analyzed by experienced specialists. In the men, fundamental frequency variation (vFe) (p<0.01), jitter. (p<0.05), and shimmer (p<0.05) for the older group were significantly higher than the value for the adult group. In the stroboscopic findings, edema of vocal fold had a significant finding in aged men (15%). In the women, vFo (p<0.05), jitter (p<0.05), and noise to harmonic ratio (NHR) (p<0.05) for the older group were significantly higher than the value for e adult group and first formant frequency (F1) (p<0.01) and second formant frequency (F2) (p<0.01) for. the older group were significantly lower than the value for the adult group. In the stroboscopic findings, vocal fold atrophy had a significant finding in aged women (25%). Frequency stability, as reflected by vFo, jitter, shimmer, and NHR, decreases with advancing age in men and women and spectral analysis of phonated /a/ vowel productions reveals the lowering of the frequency of F1 and second F2 with advancing age, especially in aged women. Change in the mass of vocal folds, due to atrophy or edema, is considered to be the greatest factor in these acoustic changes.

  • PDF

Probing Polarization Modes of Ag Nanowires with Hot Electron Detection on $Au/TiO_2$ Nanodiodes

  • Lee, Young Keun;Lee, Jaemin;Lee, Hyosun;Lee, Jung-Yong;Park, Jeong Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.225-225
    • /
    • 2013
  • Nanostructured noble metals have been attractive for their unusual optical properties and are widely utilized for various purposes. The optical properties mainly originating from collective electron oscillation can assist direct energy conversion via surface plasmon resonances. Here, we investigated the effect of surface plasmons of silver nanowires on the generation of hot electrons. It is reported that the surface plasmons of silver nanowires exhibit longitudinal and transverse modes, depending on the aspect ratio of the nanowires. In order to measure the hot electron flow through the metallic nanowires, chemically modified Au/TiO2 Schottky diodes were employed as the electric contact. The silver nanowires were deposited on a Au metal layer via the spray method to control uniformity and the amount of silver nanowire deposited. We measured the hot electron flow generated by photon absorption on the silver nanowires deposited on the Au/TiO2 Schottky diodes. The incident photon-to-current efficiency was measured a function of the photon energy, revealing two polarization modes of siliver nanowires: transverse and longitudinal modes. UV-Vis spectra exhibited two polarization modes, which are also consistent with the photocurrent measurements. Good correlation between the IPCE and UV-vis measurements suggests that hot electron measurement on nanowires on nanodiodes is a useful way to reveal the intrinsic properties of surface plasmons of nanowires.

  • PDF

Fractionated Stereotactic Radiotherapy in Pediatric Diffuse Intrinsic Brain Stem Gliomas

  • Choi, Woo-Jin;Yee, Gi-Taek;Han, Seong-Rok;Yoon, Sang-Won;Lee, Dong-Joon;Whang, Choong-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.3
    • /
    • pp.154-158
    • /
    • 2006
  • Objective : We treated 10 pediatric diffuse intrinsic brain stem glioma[BSG] patients with Novalis system [linac based radiotherapy unit, Germany] and examined the efficacy of the Fractionated Stereotactic Radiotherapy[FSRT]. Methods : A retrospective review was conducted on 10 pediatric diffuse intrinsic BSG patients who were treated with FSRT between May, 2001 and August, 2004. The mean age of the patient group was 7.7 years old. Male to female ratio was 4 to 1. The mean dose of FSRT was 38.7Gy, mean fractionated dose was 2.6Gy, mean fractionation size was 16.6, and target volume was $42.78cm^3$. The mean follow up period was 14 months. Results : Four weeks after completion of FSRT, improvements on neurological status and Karnofsky performance scale[KPS] score were recorded in 9/10 (90%] patients and magnetic resonance imaging[MRI] showed decrease in target tumor volume in 8 pediatric patients. The median survival period was 13.5 months after FSRT and treatment toxicity was mild. Conclusion : It is difficult for surgeons to choose surgical treatment for diffuse intrinsic BSG due to its dangerous anatomical structures. FSRT made it possible to control the tumor volume to improve neurological symptoms with minimal complications. We expect that FSRT is a feasible treatment modality for pediatric diffuse intrinsic BSG with tolerable toxicities.