• Title/Summary/Keyword: resonance measurements

Search Result 397, Processing Time 0.029 seconds

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.

Evaluation of Metabolic Abnormality in Brain Tumors by In Viuo $^1$H MR Spectroscopy at 3 Tesla (3T 양성자 자기공명분광에 의한 뇌종양의 대사물질 이상소견)

  • Choe, Bo-Young;Jeun, Sin-Soo;Kim, Bum-Soo;Lee, Jae-Mun;Chung, Sung-Taek;Ahn, Chang-Beom;Oh, Chang-Hyun;Kim, Sun I.;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.120-128
    • /
    • 2002
  • To investigate differences between the metabolic ratios of normal controls and brain tumors such as astrocytomas and glioblastoma multiforme (GM) by proton MR spectroscopy (MRS) at 37 high field system. Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio. The variation of metabolites measurements of the designated region in 10 normal volunteers was less than 10%. Normal ranges of NAA/Cr and Cho/Cr ratios were 1.67$\pm$018 and 1.16$\pm$0.15, respectively. NAA/Cr ratio of all tumor tissues was significantly lower than that of the normal tissues (P=0.005). Cho/Cr ratio of glioblastoma multiforme was significantly higher than that of astrocytomas (P=0.001). Lactate was observed in all tumor cases. The present study demonstrated that the neuronal degradation or loss was observed in all tumor tissues. Higher grade of brain tumors was correlated with higher Cho/Cr ratio, indicating a significant dependence of Cho levels on malignancy of gliomas. This results suggest that clinical proton MR spectroscopy could be useful to predict tumor malignancy.

  • PDF

Ultrasound Measurement of Coracohumeral Distance in Patients with or without Subcoracoid Impingement (오구돌기하 충돌 증후군 유무에 따른 초음파를 이용한 상완오구돌기 계측)

  • Jang, Suk Hwan;Kim, Sang Bum
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate coracohumeral distance (CHD) in patients with or without subcoracoid impingement with hypothesis that patients with subcoracoid impingement would have narrower CHD. Materials and Methods: One hundred twenty-four patients with subacromial impingement were evaluated. The subjects with subcoracoid impingement which was affirmed clinically and confirmed by ultrasound guided subcoracoid injection (n=28) was compared with patients with subacromial impingement only (n=96). Patients with stiffness and rotator cuff tear were excluded. Absolute CHD was measured on magnetic resonance imaging (MRI) axial images and on ultrasound with the humerus in neutral position and internal rotation. Also relative ratio of distance difference (RRDD) defined as the difference of CHD in neutral position and internal rotation compared with absolute CHD in neutral on ultrasound was also measured. Results: The distance measured in neutral position was similar between US imaging and MRI (p>0.05) and both measurements did not have significant difference between the two groups (p>0.05). On ultrasound, the difference in CHD in internal rotation between the two groups nearly met the level of significance (p=0.07). No significant difference of CHD difference in two humeral positions was seen between the two groups. However, RRDD value was significantly greater in subcoracoid impingement group (p<0.05). Conclusion: No significant difference of CHD was seen between the subcoracoid impingement group and the control group. RRDD value was greater in subcoracoid impingement group suggesting that individualized coracohumeral distance in internal rotation should be taken into account when assessing patients with subcoracoid impingement.

  • PDF

The Study On Quality Control of Magnetic Resonance Imaging System (자기공명영상장치의 정도관리에 관한 연구)

  • Jeong, Cheon-Soo;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.178-186
    • /
    • 2009
  • The quality control is needed to ensure the accuracy of medical information and achieved by evaluating the performance of and maintaining the system and practicing various measurements and evaluations. The Korean Institute for Accreditation of Medical Image, therefore, have held educational program for quality control of special medical equipments. The major of programs participants, however, are radiology specialists with only small number of radiological technologists from some hospitals, furthermore, the follow-up education and the share of information between participants and non-participants are insufficient in general, thus, the knowledge level of radiological technologists, regardless of their participation, is relatively low. This study carried out the questionnaire research for the 500 radiological technologists registered in Korean Society of MRI Technology, on the basis of 2008, and performed analysis for five months from May to Oct., 2008. The questionnaires were delivered by post to each radiological technologists and the response rate was 36%(n=180). The results of this revealed that the 86.7% of respondents felt the necessity of inspection on quality management, while only the 27.8% completed the educational program for manager of special medical equipment. and only the half(53.9%) had the knowledge about inspection on quality management. The completion of educational program had no correlations with sex, age, size of occupying hospital, the number of radiological technologists in occupying site and MRI laboratory, career year of general radiologist and in MRI laboratory, and the presence of biomedical engineering department in occupying hospital. The 78.0% of participants at the educational program for quality management held by the Korean Institute for Accreditation of Medical Image had the knowledge about inspection on quality management(p<.05) whereas the 43.9% of the hospitals held such program and the 54.4% of radiological technologists from those hospitals had related knowledge, which indicated that such programs held by hospitals had not effects on the knowledge level of radiological technologists. This indicates also that the contents, methods, and other conditional factors of educational programs are important for the outcome of them.

Studies on the Applications of PSL, TL and ESR Methods for the Detection of Dried Fruits and Mushrooms (PSL, TL 및 ESR 분석에 의한 건조과일류 및 버섯류에 대한 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Hwang, Cho-Rong;Kim, Jae-I;Lee, Kang-Bong;Jo, Tae-Yong;Eom, Mi-Ok;Park, Sue-Nie;Seong, Rack Seon;Jang, Young-Mi;Lee, Jae-Hwang;Park, Yong-Chjun;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods for various foods. The analysed samples consist of 11 items including dried fruits (6 items) and mushrooms (5 items). To compare between non-irradiated and irradiated food, all samples were irradiated with $^{60}Co$ gamma-ray source. In PSL study, the photon counts of all the unirradiated sample were identified negative (lower than 700). The photon counts irradiated (1, 5, 10 kGy) dried date-palm, dried jujube and mushrooms (Auricularia auricula, Phellinus linteus and Sarcodon aspratus) showed positive (higher than 5,000) and the results for the other samples were negative or intermediate (>700 and >5,000). In TL analysis most of items can be applicable to detect irradiated foods because of showing TL ratio above 0.1. The glow curves by TL method were estimated in the range of $150{\sim}250^{\circ}C$ in irradiated samples. In ESR measurements, the intensity of ESR signal (single-line) increased as the dose of irradiation increased. In particular, the specific ESR signals of irradiation-induced radical were detected in dried papaya, dried date-palm, dried banana, dried pineapple and S. aspratus. According to the results, PSL, TL and ESR methods were successfully applied to detect the irradiated foods. It is concluded that PSL, TL and ESR methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Studies on the Applications of TL and ESR Methods for the Detection of Spices, Berry Fruits and Pollen Extract Product (TL과 ESR 분석을 통한 일부 향신료, 장과류 및 화분가공추출물 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Kwak, Ji-Young;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.69-74
    • /
    • 2013
  • This study examined radiation detection characteristics of spices (cumin, caper and turmeric), other small fruits (hut-gae berry and boxthorn), and pollen extract product. Each samples were irradiated at dose of 1, 5, and 10 kGy and analyzed by the thermoluminescence (TL) and electron spin resonance (ESR) methods. To compare between non-irradiated and irradiated food, all samples were irradiated with $^{60}Co$ gamma-ray source. In TL analysis, most of samples could be applied to detect irradiated foods because of showing TL ratio above 0.1. The glow curves examined by TL method were estimated in the range of $150{\sim}250^{\circ}C$ in irradiated samples. In ESR measurements, the intensity of ESR signal (single-line) increased as the increase of irradiation dose. In particular, the specific ESR signals of irradiation-induced radical were detected in hut-gae berry and pollen extract product. As a results, it is considered that TL and ESR methods can be used to detect both hut-gae berry and pollen extract product. But cumin, caper, turmeric and boxthorn irradiated with gamma ray could be detected only by TL method. It is concluded that TL and ESR methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Studies on the Applications of PSL, TL and ESR Methods for The Detection of Irradiated Foods not Allowed to be Irradiated in Korea (광자극발광법, 열발광법 및 전자스핀공명법을 이용한 국내 방사선 조사 허용 외 식품에 대한 검지법 적용 연구)

  • Kim, Kyu-Heon;Choi, Eun-Jin;Chang, Ho-Won;Shin, Choon-Shik;Kim, Moon-Young;Hwang, Cho-Rong;Kim, Eun-Jeong;Jo, Tae-Yong;Park, Geon-Sang;Kang, Myung-Hee;Kim, Jae-I;Kim, Jin-Sook;Park, Sue-Nie;Seong, Rack-Seon;Jang, Young-Mi;Yoon, Hae-Sung;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.233-246
    • /
    • 2012
  • In this study, we investigated the applicability of the photostimulated luminescence(PSL), thermoluminescence(TL) and electron spin resonance(ESR) methods for various foods which are not allowed to be irradiated in Korea. All 15 foods including sesame, almond, peanut, cocoa powder etc. were analyzed. Samples were irradiated at 1~10 kGy using a $^{60}Co$ gamma-ray irradiator. In PSL study, the photon counts of all the unirradiated samples showed negative(lower than 700). The photon counts irradiated(1 kGy) dried shrimp, roasted peanut and seasoned peanut showed positive(higher than 5,000) and the other samples were negative or intermediate(> 700 and < 5,000). In TL analysis, results showed that it is possible to apply TL method to all foods containing minerals. In ESR measurements, the ESR signal(single-line) intensity of irradiated foods was higher than non-irradiated foods. In particular, the specific ESR signals of irradiation-induced crystalline sugar, cellulose and bone radical were detected in dried plum, raisin, dried cherry, mango(dried, frozen), rambutan, cocoa(powder), cinnamon, parsley, carrot, broccoli, dried arrow squid, dried pollack and dried shrimp. According to the results, PSL, TL and ESR methods were successfully applied to detect the irradiated foods because TL method is not able to detect the irradiated foods rarely composed of minerals. ESR is also a difficult method to detect the changes of ESR signal patterns of food. It is concluded that TL analysis or ESR assay is suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.