• 제목/요약/키워드: resonance measurements

검색결과 399건 처리시간 0.03초

Role of Radio Frequency and Microwaves in Magnetic Fusion Plasma Research

  • Park, Hyeon K.
    • Journal of electromagnetic engineering and science
    • /
    • 제17권4호
    • /
    • pp.169-177
    • /
    • 2017
  • The role of electromagnetic (EM) waves in magnetic fusion plasma-ranging from radio frequency (RF) to microwaves-has been extremely important, and understanding of EM wave propagation and related technology in this field has significantly advanced magnetic fusion plasma research. Auxiliary heating and current drive systems, aided by various forms of high-power RF and microwave sources, have contributed to achieving the required steady-state operation of plasmas with high temperatures (i.e., up to approximately 10 keV; 1 eV=10000 K) that are suitable for future fusion reactors. Here, various resonance values and cut-off characteristics of wave propagation in plasmas with a nonuniform magnetic field are used to optimize the efficiency of heating and current drive systems. In diagnostic applications, passive emissions and active sources in this frequency range are used to measure plasma parameters and dynamics; in particular, measurements of electron cyclotron emissions (ECEs) provide profile information regarding electron temperature. Recent developments in state-of-the-art 2D microwave imaging systems that measure fluctuations in electron temperature and density are largely based on ECE. The scattering process, phase delays, reflection/diffraction, and the polarization of actively launched EM waves provide us with the physics of magnetohydrodynamic instabilities and transport physics.

LLC 공진현상을 이용한 제논 플래쉬램프 전원회로의 설계 및 방전특성분석 (Power supply design and discharge characteristics analysis of xenon flashlamp by using LLC resonance rhenomena)

  • 이희창
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.312-317
    • /
    • 2014
  • 본 논문에서 고체레이저 광원으로 쓰이는 제논 플래쉬램프 점등을 위해 LLC공진형 컨버터 설계방법을 제안한다. 1.5kW 대용량 LLC 공진형 컨버터 제작을 통해 램프 방전특성 실험을 수행하였으며 램프 아크방전 시에 부하급변으로 인한 돌입전류를 제한하기 위한 K값의 변화에 따라 램프부하에 최대전력을 전달할 수 있으며, 콘덴서 및 전류제한저항 등을 적절하게 조절함으로써 전원장치의 원가를 절감할 수 있도록 하였다. 램프 방전회로에 대한 수학적인 모델링은 실제 방전상황에 맞추어 구성한 회로 내부손실과 램프자체의 파라미터 값들을 포함시켜 고려하였다. 시뮬레이션 결과와 실측파형을 비교분석하여 제논램프 점등조건에 대한 최적화 방안을 제시하였다.

원형분류확산화염에서의 음파가진에 의한 혼합효과 (Mixing Effect by Tone-Excitation In Round Jet Diffusion Flame)

  • 김태권;박정;신현동
    • 대한기계학회논문집B
    • /
    • 제23권6호
    • /
    • pp.795-801
    • /
    • 1999
  • An experimental investigation has been conducted with the objective of studying the mixing mechanism near the nozzle exit in a tone-excited jet diffusion flame. The fuel jet was pulsed by means of a loudspeaker-driven cavity. The excitation frequencies were chosen for the two cases of the non-resonant and resonant frequency identified as a fuel tube resonance due to acoustic excitation. The effect of tone-excitations on mixing pattern near the nozzle exit and flame was visualized using various techniques, including schlieren photograph and laser light scattering photograph from $TiO_2$ seed particles. In order to clarify the details of the flame feature observed by visualization methods, hotwire measurements have been made. Excitation at the resonant frequency makes strong mixing near the nozzle. In this case, the fuel jet flow in the vicinity of nozzle exit breaks up into disturbed fuel parcels. This phenomena affects greatly the combustion characteristics of the tone excited jet and presumably occurs by flow separation from the wall inside the fuel nozzle. As a result, in the resonant frequency the flame length reduces greatly.

Quantification of Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking

  • Park Byung-Rae
    • 대한의생명과학회지
    • /
    • 제11권2호
    • /
    • pp.129-134
    • /
    • 2005
  • Three different deconvolution techniques for quantifying cerebral blood flow (CBF) from whole brain $T2^{\ast}-weighted$ bolus tracking images were implemented (parametric Fourier transform P-FT, parametric single value decomposition P-SVD and nonparametric single value decomposition NP-SVD). The techniques were tested on 206 regions from 38 hyperacute stroke patients. In the P-FT and P-SVD techniques, the tissue and arterial concentration time curves were fit to a gamma variate function and the resulting CBF values correlated very well $(CBF_{P-FT}\;=\;1.02{\cdot}CBF_{p-SVD},\;r^2\;=\;0.96)$. The NP-SVD CBF values correlated well with the P-FT CBF values only when a sufficient number of time series volumes were acquired to minimize tracer time curve truncation $(CBF_{P-FT}\;=\;0.92{\cdot}CBF_{NP-SVD},\;r^2\;=\;0.88)$. The correlation between the fitted CBV and the unfitted CBV values was also maximized in regions with minimal tracer time curve truncation $(CBV_{fit}\;=\;1.00{\cdot}CBV_{ Unfit},\;^r^2\;=\;0.89)$. When a sufficient number of time series volumes could not be acquired (due to scanner limitations) to avoid tracer time curve truncation, the P-FT and P-SVD techniques gave more reliable estimates of CBF than the NP-SVD technique.

  • PDF

선박용 디젤발전기의 진동 절연을 위한 설계 기준 (A Design Criterion for the Vibration Isolation of a Marine Diesel Generator Set)

  • ;;이돈출
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.329-338
    • /
    • 2006
  • The resilient mounts of a diesel engine installed onboard a ship should be designed for both static and dynamic loads. If possible, the resonance frequencies of the six rigid body modes of the installation and the flexible modes of the engine support structure should not lie within the engine operation range. In this paper a design criterion is proposed to evaluate an isolation system which involves the summation of dynamic forces transmitted through the resilient mounts and elastic potential energy index stored in the mounts. A case study is also presented in which a diesel engine generator, which had an elastic foundation and was mounted in a 5500 TEU container vessel, was studied both theoretically and experimentally. The theoretical analysis of the test model was performed by using a single mass 6 degree of freedom system. Actual measurements of mechanical vibration of the engine and its foundation onboard were carried out, which showed the importance of including the flexibility of the engine support structure in the mode.

Physical and Microbiological Approach in Proving the Identity of Gamma-irradiated Different Teas

  • Kausar, Tusneem;Kim, Byeong-Keun;Kim, Dong-Ho;Kwon, Joong-Ho
    • Food Science and Biotechnology
    • /
    • 제14권1호
    • /
    • pp.1-5
    • /
    • 2005
  • Photostimulated luminescence (PSL), thermoluminescence (TL), electron spin resonance (ESR), and direct epiflourescent filter technique/aerobic plate count (DEFT/APC) were applied to detect dried green, black, and oolong teas irradiated between 0-10 kGy. Teas irradiated at 2.5 kGy and higher showed over 5000 photon counts/60 sec, while non-irradiated teas yielded 650-1000 photon counts/60 sec. TL glow curves for minerals separated from teas were detected at about $300^{\circ}C$ with low intensity in non-irradiated samples, whereas around $150^{\circ}C$ with high intensity in all irradiated samples. Ratio of $TL_1/TL_2$ based on re-irradiation step, showing lower than 0.1 and higher than 1.44 for non-irradiated and irradiated samples, respectively, enhanced reliability of TL results. ESR measurements for irradiated teas showed signals specific to irradiation. Log DEFT/APC ratio increased with irradiation dose; this result could be applied to identify irradiated tea samples.

Aqueous Solubility Enhancement of Some Flavones by Complexation with Cyclodextrins

  • Kim, Hyun-Myung;Kim, Hyun-Won;Jung, Seun-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권3호
    • /
    • pp.590-594
    • /
    • 2008
  • The inclusion complexes of cyclodextrins (CDs) with flavones in aqueous solution were investigated by phase solubility measurements. The effect of b -cyclodextrin (b -CD), heptakis (2,6-di-O-methyl) b -cyclodextrin (DM-b -CD) and 2-hydroxypropyl-b -cyclodextrin (HP-b -CD) on the aqueous solubility of three flavones, namely, chrysin, apigenin and luteolin was investigated, respectively. Solubility enhancements of all flavones obtained with three CDs followed the rank order: HP-b -CD > DM-b -CD > b -CD, and besides, CDs show higher stability constant on luteolin than that on others flavones. 1H-nuclear magnetic resonance (NMR) spectroscopy and molecular modeling was used to help establish the model of interaction of the CDs with luteolin. NMR spectroscopic analysis suggested that A-C ring, and part of the B ring of luteolin display favorable interaction with the CDs, which was also confirmed by docking studies based on the molecular simulation. The observed augmentation of solubility of luteolin by three CDs was explained by the difference of electrostatic interaction of each complex, especially hydrogen bonding.

Effect of Cervical Spinal Decompression on the Cervical Muscle Tone and Disc Height in Patients with Cervical Intervertebral Disc Herniation

  • Kang, Jeong il;Jeong, Dae Keun;Choi, Hyun
    • 국제물리치료학회지
    • /
    • 제9권1호
    • /
    • pp.1420-1425
    • /
    • 2018
  • The purpose of this study was to investigate the effect of traction and decompression therapies on the cervical muscle tone and disc height. The decompression group (n=16) received decompression therapy and Mckenzie exercises once a day and four times a week respectively, for three weeks. The traction group (n=15) also received traction therapy and Mckenzie exercises for the same period. Muscle tone was measured with a myotonometer, and the disk height was measured using magnetic resonance imaging (MRI), before the interventions. Three weeks later, we investigated the therapeutic effect by repeating these measurements. The difference in disk height between the two groups was not significant. There was a significant difference in the disk herniation index (p<.05). A significant difference was found only in the upper trapezius muscle after comparison of muscle tone and stiffness between the groups (p<.05). Findings from this study suggest that the decompression therapy is a more effective intervention for patients with cervical intervertebral disc herniation.

Realization of Alignment-Free WPT System

  • Park, Byung-Chul;Son, Yong-Ho;Jang, Byung-Jun;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • 제14권4호
    • /
    • pp.329-331
    • /
    • 2014
  • A simple realization of an alignment-free wireless power transmission (WPT) system is presented in this letter. The WPT system consists of a transmitter with three reconfigurable modes corresponding to various controllable magnetic field directions in the azimuthal plane and an algorithm for the optimum mode selection carried by sensing the reflected voltage of the system. Twelve light emitting diodes (LEDs) are used to confirm the on- and off-state of LEDs powered wirelessly by the transmitter at every $15^{\circ}$ of the azimuthal plane. A criterion voltage from the reflected power of the system is found by using the correlation between the reflected voltage and the on- and off-state of the LEDs. Simply by continuous; monitoring of the voltage from the system, the system maintains power to the LEDs. The system is realized by MATLAB/Simulink and a National Instrument data acquisition device (DAQ) board. Measurements using the system show on-state LEDs in the azimuthal plane except at the angles of $60^{\circ}$, $75^{\circ}$, $180^{\circ}$, and $300^{\circ}$.

자기공명영상의 비지도 분할을 위한 통계적 모델기반 적응적 방법 (A Statistically Model-Based Adaptive Technique to Unsupervised Segmentation of MR Images)

  • 김태우
    • 한국정보처리학회논문지
    • /
    • 제7권1호
    • /
    • pp.286-295
    • /
    • 2000
  • 본 논문은 MR 영상의 비지도 분할을 위하여 MDL원리를 이용한 통계적 모델기반의 적응적 방법을 제안한다. 이 방법에서 조직 영역을 MRF로 모델링함으로써 잡음에 대응하고, 창으로 정의되는 국소영역 내의 밝기값을 가우스 혼합으로 모델링함으로써 영상의 비균일성을 흡수한다. 분할 알고리즘은 ICM을 기반으로 하며 MAP를 근사적으로 추정하고, 모델 파라미터를 국소영역으로부터 구한다. 파라미터 추정과 분할을 위한 창의 크기는 MDL원리를 이용하여 영상으로부터 추정한다. 실험에서 제안한 방법이 특히 비균일성이 있는 MR영상의 분할에서 국소영역의 영상특성을 잘 반영하였으며, 기존의 방법보다 더 좋은 결과를 보여주었다.

  • PDF