• Title/Summary/Keyword: resonance field

Search Result 958, Processing Time 0.032 seconds

NMR Studies on the Structure of Human Annexin I

  • Han, Hee-Yong;Bang, Keun-Su;Na, Doe-Sun;Lee, Bong-Jin
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.182-182
    • /
    • 1996
  • Annexin I is a member of the annexin family of calcium dependent phospholipid binding proteins and has anti-inflammatory activity by inhibiting phospholipase A$_2$ (PLA$_2$). Recent X-ray crystallographic study of annexin I identified six Ca$\^$2+/ binding bites, which was different types (type II, III) from the well-known EF-hand motif (type I). In this work, the structure of annexin I was studied at atomic level by using $^1$H, $\^$15/N and $\^$l3/C NMR(nuclear magnetic resonance) spectroscopy, and the effect of Ca$\^$2+/ binding on the structure of annexin I was studied, and compared with that of Mg$\^$2+/ binding, When Ca$\^$2+/ was added to annexin I, NMR peak change was occured in high- and low-field regions of $^1$H-NMR spectra. NMR peak change by Ca$\^$2+/ binding was different from that by Mg$\^$2+/ binding. Because annexin I is a larger protein with 35 kDa molecular weight, site-specific (amide-$\^$15/N, carbonyl-$\^$l3/C) labeling technique was also used. We were able to detect methionine, tyrosine and phenylalanine peaks respectively in $\^$13/C-NMR spectra, and each residue was able to be assigned by the method of doubly labeling annexin I with [$\^$13/C] carbonyl-amino acid and [$\^$15/N] amide-amino acid. In $\^$l3/C-NMR spectra of [$\^$13/C] carbonyl-Met labeled annexin I, we observed that methionine residues spatially located near Ca$\^$2+/ binding Sites Were Significantly effected by Ca$\^$2+/ binding. From UV spectroscopic data on the effect of Ca$\^$2+/ binding, we knew that Ca$\^$2+/ binding sites of annexin I have cooperativity in Ca$\^$2+/ binding. The interaction of annexin I with PLA$_2$ also could be detected by using heteronuclear NMR spctroscopy. Consequently, we expect that the anti-inflammatory action mechanism of annexin I may be a specific protein-protein interaction. The residues involved in the interaction with PLA$_2$ can be identified as active site by assigning NMR peaks effected by PLA$_2$ binding.

  • PDF

Effect of bamboo shoot dietary fiber on gel properties, microstructure and water distribution of pork meat batters

  • Li, Ke;Liu, Jun-Ya;Fu, Lei;Zhao, Ying-Ying;Zhu, He;Zhang, Yan-Yan;Zhang, Hua;Bai, Yan-Hong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.7
    • /
    • pp.1180-1190
    • /
    • 2020
  • Objective: To develop healthier comminuted meat products to meet consumer demand, the gel properties, rheological properties, microstructure and water distribution of pork meat batters formulated with various amounts of bamboo shoot dietary fiber (BSDF) were investigated. Methods: Different levels of BSDF (0% to 4%) were added to pork batters, and the pH, color, water-holding capacity, texture and rheological properties of pork batters were determined. Then, pork batters were analyzed for their microstructure and water distribution using scanning electron microscopy (SEM) and low-field nuclear magnetic resonance (LF-NMR). Results: Compared with the control, BSDF addition into meat batters showed a significant reduction in L*-value and a significant increase in b*-value (p<0.05). BSDF addition of up to 4% reduced the pH value of pork batters by approximately 0.15 units; however, the cooking loss and expressible water loss decreased significantly (p<0.05) with the increased addition of BSDF. The hardness and gel strength were noticeably enhanced (p<0.05) as the content of BSDF increased. The rheological results showed that BSDF added into pork batters produced higher storage modulus (G') and loss modulus (G") values. The SEM images suggested that the addition of BSDF could promote pork batters to form a more uniform and compact microstructure. The proportion of immobilized water increased significantly (p<0.05), while the population of free water was decreased (p<0.05), indicating that BSDF improved the water-holding capability of pork batters by decreasing the fraction of free water. Conclusion: BSDF could improve the gel properties, rheological properties and water distribution of pork meat batters and decrease the proportion of free water, suggesting that BSDF has great potential as an effective binder in comminuted meat products.

Microbiological Features and Bioactivity of a Fermented Manure Product (Preparation 500) Used in Biodynamic Agriculture

  • Giannattasio, Matteo;Vendramin, Elena;Fornasier, Flavio;Alberghini, Sara;Zanardo, Marina;Stellin, Fabio;Concheri, Giuseppe;Stevanato, Piergiorgio;Ertani, Andrea;Nardi, Serenella;Rizzi, Valeria;Piffanelli, Pietro;Spaccini, Riccardo;Mazzei, Pierluigi;Piccolo, Alessandro;Squartini, Andrea
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.5
    • /
    • pp.644-651
    • /
    • 2013
  • The fermented manure derivative known as Preparation 500 is traditionally used as a field spray in biodynamic agriculture for maintaining and increasing soil fertility. This work aimed at characterizing the product from a microbiological standpoint and at assaying its bioactive properties. The approach involved molecular taxonomical characterization of the culturable microbial community; ARISA fingerprints of the total bacteria and fungal communities; chemical elemental macronutrient analysis via a combustion analyzer; activity assays for six key enzymes; bioassays for bacterial quorum sensing and chitolipooligosaccharide production; and plant hormone-like activity. The material was found to harbor a bacterial community of $2.38{\times}10^8$ CFU/g dw dominated by Gram-positives with minor instances of Actinobacteria and Gammaproteobacteria. ARISA showed a coherence of bacterial assemblages in different preparation lots of the same year in spite of geographic origin. Enzymatic activities showed elevated values of ${\beta}$-glucosidase, alkaline phosphatase, chitinase, and esterase. The preparation had no quorum sensing-detectable signal, and no rhizobial nod gene-inducing properties, but displayed a strong auxin-like effect on plants. Enzymatic analyses indicated a bioactive potential in the fertility and nutrient cycling contexts. The IAA activity and microbial degradation products qualify for a possible activity as soil biostimulants. Quantitative details and possible modes of action are discussed.

Radiological Apoplexy and Its Correlation with Acute Clinical Presentation, Angiogenesis and Tumor Microvascular Density in Pituitary Adenomas

  • Lee, Jung-Sup;Park, Yong-Sook;Kwon, Jeong-Taik;Nam, Taek-Kyun;Lee, Tae-Jin;Kim, Jae-Kyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.281-287
    • /
    • 2011
  • Objective : Pituitary apoplexy is life-threatening clinical syndrome caused by the rapid enlargement of a pituitary tumor due to hemorrhage and/or infarction. The pathogenesis of pituitary apoplexy is not completely understood. We analyzed the magnetic resonance imaging (MRI) of pituitary tumors and subsequently correlated the radiological findings with the clinical presentation. Additionally, immunohistochemistry was also performed to determine whether certain biomarkers are related to radiological apoplexy. Methods : Thirty-four cases of pituitary adenoma were enrolled for retrospective analysis. In this study, the radiological apoplexy was defined as cases where hemorrhage, infarction or cysts were identified on MRI. Acute clinical presentation was defined as the presence of any of the following symptoms: severe sudden onset headache, decreased visual acuity and/or visual field deficit, and acute mental status changes. Angiogenesis was quantified by immunohistochemical expression of fetal liver kinase 1 (Flk-1), neuropilin (NRP) and vascular endothelial growth factor (VEGF) expression, while microvascular density (MVD) was assessed using Endoglin and CD31. Results : Clinically, fourteen patients presented with acute symptoms and 20 for mild or none clinical symptoms. Radiologically, fifteen patients met the criteria for radiological apoplexy. Of the fifteen patients with radiologic apoplexy, 9 patients presented acute symptoms whereas of the 19 patient without radiologic apoplexy, 5 patients presented acute symptoms. Of the five biomarkers tracked, only VEGF was found to be positively correlated with both radiological and nonradiological apoplexy. Conclusion : While pituitary apoplexy is currently defined in cases where clinical symptoms can be histologically confirmed, we contend that cases of radiologically identified pituitary hemorrhages that present with mild or no symptoms should be designated subacute or subclinical apoplexy. VEGF is believed to have a positive correlation with pituitary hemorrhage. Considering the high rate of symptomatic or asymptomatic pituitary tumor hemorrhage, additional studies are needed to detect predictors of the pituitary hemorrhage.

Magnetic Resonant Wireless Power Transfer Using Reconfigurable Slit Ground Resonator for Laptop Computer (재구성 슬릿 그라운드 공진기를 이용한 노트북용 자기공진형 무선전력전송)

  • Kang, Seok Hyon;Jung, Chang Won
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • In this paper, slit ground resonator with slit and capacitor is proposed for practical use of magnetic resonant wireless power transfer(MR-WPT). And this paper presents the performance comparison of conventional loop resonator as Rx resonator to slit ground resonator. The proposed silt ground resonator with 31 cm width, 20.5 cm length, $35{\mu}m$ thickness is designed the crossing slit 1 cm width with only opened edge. And an external capacitors were connected at the opened edge of slit ground resonator for resonating at 6.78 MHz. The transfer efficiencies of MR-WPT were measured at open and short mode, and then the highest transfer efficiencies of MR-WPT according to the Rx resonators were plotted. In result, the transfer efficiency of MR-WPT with loop resonator was the highest. However, when the ground was inserted in receiver part at the bottom of laptop model, the transfer efficiency was closed 0 %. The transfer efficiency recovered the transfer efficiency of 67 % using slit ground resonator. The magnetic field was penetrated through the slit and proposed slit ground resonator works as resonator in MR-WPT.

Determination of Stereotactic Target Position with MR Localizer (자기공명영상을 이용한 두개부내 표적의 3차원적 위치결정)

  • 최태진;김옥배;주양구;서수지;손은익
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.67-77
    • /
    • 1996
  • Purpose: To get a 3-D coordinates of intracranial target position was investicated in axial, sagittal and coronal magnetic resonance imaging with a preliminary experimented target localizer. Material and methods : In preliminal experiments, the localizer is made of engineering plastic to avoid the distrubance of magnetic field during the MR image scan. The MR localizer displayed the 9 points in three different axial tomogram. The bright signal of localizer was obtjained from 0.1~0.3% of paramagnetic gadolinium/DTPA solution in T1WI or T2WI. In this study, the 3-D position of virtual targets were examined from three different axial MR images and the streotactic position was compared to that of BRW stereotactic system in CT scan with same targets. Results: This study provided the actual target position could be obtained from single scan with MRI localizer which has inverse N-typed 9 bars. This experiment was accomplished with shimming test for detection of image distortion in MR image. However we have not found the image distortion in axial scan. The maximum error of target positions showed 1.0 mm in axial, 1.3 mm for sagittal and 1.7 mm for coronal image, respectivelly. The target localization in MR localizer was investicated with spherical virtual target in skull cadaver. Furthermore, the target position was confirmed with CRW stereotactic system showed a 1.3 mm in discrepancy. Summary : The intracranial target position was determined within 1.7 mm of discrepancy with designed MR localizer. We found the target position from axial image has more small discrepancy than that of sagittal and coronal image.

  • PDF

Improved Transmission Path Visualization of Vibration Power Flow for Stiffened Plate Using Streamlines Representation (유선 표현법을 이용한 보강판의 진동파워흐름에 대한 개선된 전달경로 가시화)

  • Fawazi, Noor;Jeong, Un-Chang;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.7
    • /
    • pp.692-700
    • /
    • 2012
  • Vibration intensity has been used to localize vibration source of a vibrating system. Not only that, vibration intensity has also been used for structural diagnostic in identifying crack and mounted stiffeners. To clearly identify the location of vibration source and understand the changes of energy transmission path, clear flow visualization is required. Most of previous works used vectors to indicate the magnitude and direction of emerging vibration energy and transmission paths. However, due to the large surface area of a plate like-structure, clear transmission paths cannot be achieved using vector visualization. This becomes an issue when detail vector flow at all locations of the whole plate surface is required. In this study, streamlines visualization is used to clearly indicate the power flow transmission path at all plate surface. By using streamlines representation, not only clear transmission paths are obtained, but also improves the vector visualization which helps us to understand the changes of the energy flow especially for stiffened plates. In this study, vibration intensity computation is firstly compared to previous work to validate the vibration intensity computation. To clearly show the power flow transmission paths, streamlines representation is shown. This representation overcomes the unclear vector direction especially for stiffened plates. Different pattern of energy transmission path can be observed using streamlines representation for stiffened and unstiffened plate. The complex streamlines pattern can also be observed at high resonance frequencies which is unclear by using vector representation.

Noninvasive Method to Distinguish between Glucose and Sodium Chloride Solution Using Complementary Split-Ring Resonator (Complementary Split Ring Resonator(CSRR)를 이용한 포도당과 염화나트륨 수용액의 비침습적 구별)

  • Jang, Chorom;Park, Jin-Kwan;Yun, Gi-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • In this work, glucose solution and sodium chloride solution were distinguished noninvasively using a microwave complementary split-ring resonator (CSRR). Based on the electrical properties of the two solutions measured using a open-ended coaxial probe, a CSRR was designed and fabricated for operation at a specific frequency that facilitates differentiating the two solutions. Furthermore, a polydimethylsiloxane mold was fabricated to concentrate the solution at a region where the electric field of the resonator was strongest, and a laminating film was used to prevent contact between the solution and resonator. Experiments were performed by dropping $50{\mu}L$ of the solution in steps of 100 mg/dL up to a maximum human blood glucose level of 400 mg/dL. Our experiments confirmed that the transmission coefficients ($S_{21}$) of glucose solution and sodium chloride solution exhibit variations of -0.06 dB and 0.14 dB, respectively, per 100 mg/dL concentration change at the resonance frequency. Thus, the opposite trends in the variation of $S_{21}$ with change in the concentration of the two solutions can be used to distinguish between them.

Numerical Simulation of Irregular Airflow within Wave Power Converter Using OWC by Action of 3-Dimensional Irregular Waves (3차원불규칙파동장하의 진동수주형 파력발전구조물에서 불규칙공기흐름의 수치시뮬레이션)

  • Lee, Kwang-Ho;Park, Jung-Hyun;Kim, Do-Sam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.3
    • /
    • pp.189-202
    • /
    • 2012
  • An Oscillating Water Column (OWC) wave generation system uses the air flow induced by the vertical motion of water column in the air chamber as a driving force of turbine. It is well known that OWC is one of the most efficient devices to harness wave power. This study estimated the air flow velocity from the time variation of the water level fluctuation in the air chamber under regular wave conditions using 3-dimensional numerical irregular wave tank (3D-NIT) model that can simulate the 3-dimensional irregular wave field. The applicability of the 3D-NIT model was validated by comparing numerically predicted air flow velocities with hydraulic experimental results. In addition, the characteristics of air flow frequency spectrum variation due to the incident frequency spectrum change, and the variations of frequency spectrum and wave reflection due to the existence of converter inside the air chamber were discussed. It is found that the phase difference exists in between the air flow velocity and the water level fluctuation inside the air chamber, and the peak frequency of the spectrum in water level fluctuation is amplified by the resonance in the air chamber.

Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T. (강자성 인공물 발생에 대한 자기공명영상 질 평가: 1.5T와 3.0T 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.193-199
    • /
    • 2018
  • In this research, 15 patients were diagnosed with 1.5T and 3.0T MRI instruments (Philips, Medical System, Achieva) to minize Ferromagnetic artifact and find the optimized Tesla. Based on the theory that the 3.0T, when compared to 1.5T, show relatively high signal-to-ratio(SNR), Scan time can be shortened or adjust the image resolution. However, when using the 3.0T MRI instruments, various artifact due to the magnetic field difference can degrade the diagnostic information. For the analysis condition, area of interest is set at the background of the T1, T2 sagittal image followed by evaluation of L3, L4, L5 SNR, length of 3 parts with Ferromagnetic artifact, and Histogram. The validity evaluation was performed by using the independent t test. As a result, for the SNR evaluation, mere difference in value was observed for L3 between 1.5T and 3.0T, while big differences were observed for both L4, and L5(p<0.05). Shorter length was observed for the 1.5T when observing 3 parts with Ferromagnetic artifact, thus we can conclude that 3.0T can provide more information on about peripheral tissue diagnostic information(p<0.05). Finally, 1.5T showed higher counts values for the Histogram evaluation(p<0.05). As a result, when we have compared the 1.5T and 3.0T with SNR, length of Ferromagnetic artifact, Histogram, we believe that using a Low Tesla for Spine MRI test can achieve the optimal image information for patients with disk operation like PLIF, etc. in the past.