• Title/Summary/Keyword: resonance evaluation

Search Result 855, Processing Time 0.057 seconds

Arthroscopic Release of the Extensor Carpi Radialis Brevis Tendon for Chronic Recalcitrant Lateral Epicondylitis (만성 불응성 외 상과염에서 시행한 관절경적 단 요 수근 신건 유리술)

  • Ku, Jung Hoei;Hwang, Tae Hyok;Lee, Jung Su;Cho, Hyung Lae;Kim, Jung Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.140-146
    • /
    • 2012
  • Purpose: The objective of this study was to assess the clinical outcome of arthroscopic release of the extensor carpi radialis brevis (ECRB) tendon in chronic recalcitrant lateral epicondylitis and tried to determine any prognostic factors. Materials and Methods: A retrospective review of 24 patients with lateral epicondylitis treated by arthroscopic ECRB release was performed. Outcome measures included a patient self rating and visual analog scale (VAS). Functional evaluation was made with Quick-disabilities of the arm, shoulder and hand (DASH) score system to identify preoperative factors that might be associated with the outcomes. Results: Twenty one (88%) elbows received benefit from the procedure. A mean preoperative VAS pain score and the mean Quick-DASH were significantly improved at final follow up. Age, sex, dominant arm and duration of symptom, presence of capsular tear or calcification did not correlate significantly with the clinical outcome. Three of four patients without T2-weighted high signal focus of the ECRB origin on preoperative magnetic resonance imaging (MRI) showed higher Quick-DASH score. Conclusion: Arthroscopic release of the ECRB is an effective option for chronic recalcitrant lateral epicondylitis. Lack of high signal focus on preoperative MRI is significantly associated with a poor surgical outcome and a considerable factor for the proper surgical indication.

  • PDF

Assessment of Detection Rate Applying the Digital Convergence Mammographic Imaging Methods(FFDM, DBT, BMRI): Based on Breast Density (디지털 융복합 유방 영상 검사기법(FFDM, DBT, BMRI)을 사용한 검출률 평가 : 유방밀도에 근거하여)

  • Jang, Eun-Hee;Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.281-291
    • /
    • 2017
  • This study aimed to assess detection rate applying the mammographic imaging methods. The evaluation of the shape and margin of tumor was conducted by score oriented to 180 patients who had undergone FFDM, DBT and BMRI scans among breast cancer patients, and the number of calcification was classified by size. There was no significant difference between DBT and BMRI for tumors larger than 1 cm in low-density breasts and for tumors larger than 2 cm in high-density breasts. Moreover, as for the detection rate of number of fine calcification, the highest rate was observed in FFDM followed by DBT and BMRI in the order named regardless of size. In conclusion, DBT was able to be detected even without BMRI if the mass was larger than 1 cm in the low-density breast and larger than 2 cm in the high-density breast. The detection rate of calcification turned out to be the highest in FFDM followed by DBT regardless of size, and calcification was not observed by BMRI. The appropriate use of FFDM, DBT and BMRI with respect to mass tumor will contribute to serving as a guide to examination methods of reducing burden of patients.

Evaluation of Traumatic Intracranial Hemorrhage Using Computed Tomography and Magnetic Resonance Imaging in Four Dogs (개에서 컴퓨터단층촬영술과 자기공명영상을 이용한 창상성 두개관내 출혈의 평가)

  • Choi Ho-Jung;Lee Ki-Ja;Kang Sang-Kyu;Lee Hee-Chun;Chang Dong-Woo;Lee Ki-Chang;Jeong Seong-Mok;Cho Sung-Whan;Lee Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.96-101
    • /
    • 2006
  • Four dogs with neurologic dysfunction resulted from intracranial hemorrhage by head trauma were referred to Veterinary Medical Teaching Hospital, Chungnam National University. There were no remarkable findings in survey radiography in four cases. CT and MRI scans were diagnostic in these cases. Three dogs underwent CT scanning. On CT images, the lesion was hyperdense and was not enhanced after intravenous contrast administration in dog 1 and dog 2. On CT of dog 4, there was no significant finding. All of four dogs were verified by dorsal, sagittal, and transverse T1-weighted (T1W) and T2-weighted (T2W) images. Appearance of the lesions in dog 1 and dog 2 was isointense (dog 2) or isointense with hyperintense rim (dog 1) on T1W images and hyperintense on T2W images. In dog 3 and dog 4, there were hypointense and hyperintense lesions on T1Wand T2W images respectively. The lesions in four dogs were located in the left intracerebral region, intracerebral and cerebellovestibular region, subdural space, and right cerebral hemisphere, respectively.

Estimating Concrete Compressive Strength Using Shear Wave Velocity (전단파 속도를 이용한 콘크리트의 압축강도 추정연구)

  • An, Ji-Hwan;Nam, Jeong-Hee;Kwon, Soo-Ahn;Joh, Sung-Ho
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.171-178
    • /
    • 2008
  • Compressive strength of concrete has been regarded as a very important parameter of the quality control both in new and existing concrete pavement. It has been used a lot as the concrete strength evaluation both in the various-mixture-using laboratory and construction field using the same mixture. An error usually occurs in the test experiments of the strength, even in the test experiments with evenly mixed and compacted specimens of the compressive strength. It is caused by the 'manually operated' compressing testing, or by the specimens preparation with eccentricity. When compressive strength of evenly mixed concrete is investigated by the curing ages at the construction field, there have to be lots of specimens. And it needs much labor and cost. To substitute the endlessly repeated test experiments of compressive strength, presumption of compressive strength, by nondestructive tests, is needed. In this study, elastic waves were used among various nondestructive tests. Compressive strength of concrete was presumed according to the curing ages, by using the shear wave velocity which is not affected by restricted conditions. In the result, shear wave velocity is very closely related to the compressive strength at the evenly mixed concrete.

  • PDF

Development of the New Hybrid Evolutionary Algorithm for Low Vibration of Ship Structures (선박 구조물의 저진동 설계를 위한 새로운 조합 유전 알고리듬 개발)

  • Kong, Young-Mo;Choi, Su-Hyun;Song, Jin-Dae;Yang, Bo-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.164-170
    • /
    • 2006
  • This paper proposes a RSM-based hybrid evolutionary algorithm (RHEA) which combines the merits of the popular programs such as genetic algorithm (GA), tabu search method, response surface methodology (RSM). This algorithm, for improving the convergent speed that is thought to be the demerit of genetic algorithm, uses response surface methodology and simplex method. The mutation of GA offers random variety to finding the optimum solution. In this study, however, systematic variety can be secured through the use of tabu list. Efficiency of this method has been proven by applying traditional test functions and comparing the results to GA. And it was also proved that the newly suggested algorithm is very effective to find the global optimum solution to minimize the weight for avoiding the resonance of fresh water tank that is placed in the rear of ship. According to the study, GA's convergent speed in initial stages is improved by using RSM method. An optimized solution is calculated without the evaluation of additional actual objective function. In a summary, it is concluded that RHEA is a very powerful global optimization algorithm from the view point of convergent speed and global search ability.

  • PDF

Recurrent Shoulder Dislocation and Proximal Humerus Fracture in Neurofibromatosis Type I - A Case Report - (제 1형 신경 섬유종증 환자에서 발생한 재발성 견관절 탈구 및 근위 상완골 골절 - 1예 보고 -)

  • Hwang, Tae Hyok;Cho, Hyung Lae;Wang, Tae Hyun;Yang, Hui Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.135-140
    • /
    • 2013
  • We report a case of recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I. A twenty-year-old male patient with known neurofibromatosis type I presented with right shoulder dislocation and proximal humerus fracture following a minor trauma. His injured arm also had large plexiform neurofibromas on the elbow, and the dislocation of the shoulder joint was proven to be recurrent. Bony deformation of the humerus and scapula were revealed on X-ray and computed tomography, as well as multiple neurofibromatic changes of the deltoid and periscapular muscles were noted on magnetic resonance imaging. Open reduction and capsular reconstruction were performed and humeral fracture was stabilized with a reconstruction plate. Satisfactory union and functional result were achieved and the dislocation did not recur until the 7-month followup after the procedure. Recurrent shoulder dislocation and combined proximal humerus fracture in neurofibromatosis type I are rare complications. However, it should still be considered in the orthopaedic evaluation process of the diseases.

Evaluation of the signal intensity of magnetic resonance angiography in accordance with the dilution rate of the contrast agent (조영제 희석률에 따른 조영증강 자기공명혈관조영검사의 신호강도 평가)

  • Choi, Kwan-Woo;Seo, Sung-Mi;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5124-5130
    • /
    • 2014
  • Dilution of the contrast agent by analyzing the change in the signal intensity during MR angiography in accordance with the viscosity and osmotic pressure minimizes the side effects, and improves the image quality. The contrast agent molarity changes by the dilution of the contrast agent in the blood, as it is injected, which leads to a change in signal intensity. Based on this principle, a phantom was prepared and experiments were performed. After the phantom experiment, a clinical experiment was conducted using the results of the phantom experiment. From November 2013 to January 2014, a group of patients were classified into diluted contrast agent (30 persons) and undiluted (30 persons), and the signal intensity of the cerebral vessels was compared. The signal intensity of the phantom according to the molarity of the contrast agent increased sharply from 0.0125 mmol, reached a peak at 20 mmol, and achieved equilibrium from 200 mmol. Based on the study results, the signal intensity of the blood vessels in the brain through were compared in a clinical experiment. All the brain vessels in the imaging range with diluting a high content of the gadolinium contrast agent showed high signal intensity. This result supports the phantom experiment and means that using the 500mmol diluted contrast agent is better than using 1000mmol undiluted contrast agent because it is easier to approach the 20mmol level needed to achieve the highest signal intensity. This study has significance in that it can minimize the high viscosity and osmotic pressure, which can cause side effects and improve the image quality using the method of the dilution rate.

Evaluation of Stability of Double Threaded Implant-Emphasis on Initial Stability Using Osstell MentorTM; Part I (이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I)

  • Kim, Si-Yeob;Kim, Byung-Kook;Heo, Jin-Ho;Lee, Ju-Youn;Jeong, Chang-Mo;Kim, Yong-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.327-336
    • /
    • 2007
  • Purpose This study was planned to compare and evaluate the stability of implant using $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Material and methods Artificial bone and RBM(resorbable blasting media) surface blasted implants(Osstem US II, SS II implants - diameter: 4mm, length: 13mm) were used. To measure the stability of installed implants, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ were used. In the first experiment, five implants were installed in D1(external type implants) and D3(internal type implants). In the second experiment, 4 internal type implants were divided in two groups and installed in D1 artificial bone with different depth. In the third experiment, two external implants were installed in D1 and D3 artificial bone each and two internal implants were installed in D1 and D3 artificial bone. In all groups, their stability were measured by $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Results In all groups, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ both showed reliable measurement values. The value difference between $Osstell^{TM}$ and Osstell $Mentor^{TM}$ was observed but the difference was small and clinically acceptable. Conclusion These results suggest that the use of Osstell $Mentor^{TM}$ has clinical relevance in the assessment of implant stability.

The Correlation between Caudal Epidurogram and Low Back Pain

  • Jo, Dae-Hyun;Jang, Sul
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.22-27
    • /
    • 2012
  • Background: The common causes of lower back pain with or without leg pain includes disk disease and spinal stenosis. A definitive diagnosis is usually made by means of magnetic resonance imaging (MRI), but treatment is often difficult because the MRI findings are not consistent with the symptoms of the patient in many cases. The objective of this study was to observe the correlation between the patterns of epidurography performed in patients having lower back pain with or without leg pain and the position or severity of the pain as subjectively described by the patients. Methods: The subjects of this study were 69 outpatients with lower back pain with or without leg pain who visited our clinic and complained of predominant pain on one side. We performed caudal epidural block using an image intensifier. A mixture of the therapeutic drug and the contrast agent (10 ml) was injected to observe the contrast flow pattern. The patients who complained of predominant pain on one side were divided into the left side group and the right side group. A judgment of inconsistency was made if the contrast agent flowed to the side of the pain, while a judgment of consistency was made if the contrast agent flowed to the opposite side of the pain. The degree of the drug distribution was evaluated by counting the number of cells to which the contrast agent's flowed for evaluating the correlation between the contrasted cell and the severity of pain (one group ${\leq}$ VAS 7, the other group ${\geq}$ VAS 8) the degree of the contrast agent's contrast was evaluated by dividing and counting an image into 15 cells (the left, right, and middle sections at each level of L4, L5, S1, S2, and S3). Results: Thirty out of the 69 patients who had laterality in pain, that is, those who complained of predominant pain on one side, showed that the laterality of the pain and the contrast agent flow was consistent, while 39 patients showed that the laterality was inconsistent (P: 0.137). The evaluation of the correlation between the pain and the contrast agent flow showed that the mean number of contrasted cells was $9.0{\pm}2.2$ for the 46 patients in the group with a VAS of 7 or lower and $6.5{\pm}2.0$ for the 23 patients in the group with a VAS of 8 or higher, indicating that the former group showed a significantly greater number of contrasted cells (P < 0.001). Conclusions: This study, conducted with patients having lower back pain with or without leg pain, showed that the contrast flow pattern of caudal epidurography had a significant correlation with the severity of the pain but not with the laterality of the pain.

Real-time Feedback Vibration Control of Structures Using Wireless Acceleration Sensor System - System Design and Basic Performance Evaluation - (무선 가속도센서 시스템을 이용한 건축물의 실시간 피드백 진동제어 - 시스템 구축 및 기초성능 평가 -)

  • Jeon, Joon Ryong;Park, Ki Tae;Lee, Chin Ok;Heo, Gwang Hee;Lee, Woo Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.21-32
    • /
    • 2013
  • This is a preliminary study for the real-time feedback vibration control of building structures. The study developed a wireless acceleration sensor system based on authentic technology capacities, to integrate with the Prototype AMD system and ultimately construct the feedback vibration control system. These systems were used to evaluate the basic performance levels of the control systems within model building structures. For this purpose, the study first developed a wireless acceleration sensor unit that integrates an MEMS sensor device and bluetooth communication module. Also, the study developed an operating program that enables control output based on real-time acceleration response measurement and control law. Furthermore, the Prototype AMD and motor driver system were constructed to be maneuvered by the AC servo-motor. Eventually, all these compositions were used to evaluate the real-time feedback vibration control system of a 2-story model building, and qualitatively measure the extent of vibrational reduction of the target structure within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within the laboratory validation tests. As a result of the tests, there was a definite vibrational reduction effect within 1st and 2nd resonance frequency as well as the random frequency of the model building structure. Ultimately, this study confirmed the potential of its wireless acceleration sensor system and AMD system as an effective tool that can be applied to the active vibration control of other structures.