• Title/Summary/Keyword: resonance evaluation

Search Result 855, Processing Time 0.031 seconds

Evaluation of Effects on Impact Resonance Test for Determining Modulus of Asphalt Concrete (아스팔트 콘크리트 탄성계수 결정을 위한 충격공진시험 영향요소 평가)

  • Kweon, Gi-Chul;Lee, Jae-Hoan
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.89-99
    • /
    • 2007
  • The stiffness of the asphalt concrete is represented by the complex modulus $E^*$, which is very important properties in the mechanistic design of flexible pavement system. The moduli of asphalt concrete were generally determined by dynamic modulus test. However, the dynamic modulus testing method is too complex, expensive, and time consuming to be applicable on a production basis. The IR(Impact Resonance) method has been shown to be a truly simple nondestructive testing method which produces very repetitive, consistent results. The major object of this study was to estimate of the effects on IR tests for determining modulus of asphalt concrete including impact position, specimen support condition, impact steel ball size and sampling rate. The variations of IR test results with various testing conditions are within ${\pm}2.7%$.

  • PDF

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

Carotid Intraplaque Hemorrhage is Associated with Acute Cerebral Ischemic Events and Progression of Stenosis on Magnetic Resonance Imaging

  • Ryu, Hye Ji;Jeon, Se Jeong;Choi, See Sung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.242-251
    • /
    • 2017
  • Purpose: To investigate the association of carotid intraplaque hemorrhage (IPH) with acute cerebral ischemic events and progression of stenosis using magnetic resonance (MR) imaging. Materials and Methods: From April 2014 to December 2016, 53 patients underwent carotid plaque MR imaging, including magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequence. A total of 66 carotid arteries in 53 patients had carotid stenosis, and they were included in this study. Carotid arteries were classified according to the presence of IPH, the age of hemorrhage, and degree of stenosis. We assessed ipsilateral cerebrovascular event rates and progression of stenosis between the IPH and no-IPH groups. Results: Of the 61 carotid arteries assessed, 34 (56%) had IPH, and 27 (44%) had no IPH. Acute cerebral ischemic events were more frequent in the IPH group (47% vs. 22%, P = 0.045), especially in the < 30%-stenosis group (100% vs. 0%, P = 0.028). However, there was no significant difference in the incidence of ischemic events according to the age of hemorrhage (50% vs. 44%, P = 0.492). Among the 61 carotid arteries, 20 carotid arteries had previously undergone carotid artery imaging and were evaluated for plaque progression. The trend for progression of stenosis favored the IPH group versus the no-IPH group, with a marginal P-value ($20%{\pm}12.7$ vs. $9.6%{\pm}5.7$, P = 0.063). Conclusion: IPH was associated with an increased incidence of acute ischemic events, especially in the mild-stenosis group and it was also associated with progression of stenosis. Evaluation of the carotid IPH by carotid plaque MR could improve discrimination of carotid plaques that cause ischemic events and progression of stenosis.

Detection of Micro-Crack Using a Nonlinear Ultrasonic Resonance Parameters (비선형 초음파공명 특성을 이용한 미세균열 탐지)

  • Cheong, Yong-Moo;Lee, Deok-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.369-375
    • /
    • 2012
  • In order to overcome the detection limit by the current nondestructive evaluation technology, a nonlinear resonant ultrasound spectroscopy(NRUS) technique was applied for detection of micro-scale cracks in a material. A down-shift of the resonance frequency and a variation of normalized amplitude of the resonance pattern were suggested as the nonlinear parameter for detection of micro-scale cracks in a materials. A natural-like crack were produced in a standard compact tension(CT) specimen by a low cycle fatigue test and the resonance patterns were acquired in each fatigue step. As the exciting voltage increases, a down-shift of resonance frequency were increases as well as the normalized amplitude decrease. This nonlinear effects were significant and even greater in the cracked specimen, but not observed in a intact specimen.