• 제목/요약/키워드: resolution correction

검색결과 455건 처리시간 0.024초

GROUND RECEIVING SYSTEM FOR KOMPSAT-2

  • Kim, Moon-Gyu;Kim, Tae-Jung;Park, Sung-Og;Im, Yong-Jo;Shin, Ji-Hyun;Choi, Myung-Jin;Park, Seung-Ran;Lee, Jong-Ju
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.804-809
    • /
    • 2002
  • Remote sensing division of satellite technology research center (SaTReC), Korea advanced institute of science and technology (KAIST) has developed a ground receiving and processing system for high resolution satellite images. Developed system will be adapted and operated to receive, process and distributes images acquired from of the second Korean Multi-purpose Satellite (KOMPSAT-2), which will be launched in 2004. This project had initiated to develop and Koreanize the state-of-the-art technologies related to the ground receiving system fur high resolution remote sensing images, which range from direct ingestion of image data to the distribution of products through precise image correction. During four years development, the system has been verified in various ways including real operation of custom-made systems such as a prototype system for SPOT and a commercialised system for KOMPSAT-1. Currently the system is under customisation for installation at KOMPSAT-2 ground station. In this paper, we present accomplished work and future work.

  • PDF

고해상도 위성영상의 센서모델링을 위한 대기 및 속도 보정 (Atmospheric Correction and Velocity Aberration for Physical Sensor Modeling of High-Resolution Satellite Images)

  • 오재홍;이창노
    • 한국측량학회지
    • /
    • 제29권5호
    • /
    • pp.519-525
    • /
    • 2011
  • High-resolution earth-observing satellites acquire substantial amount of geospatial images. In addition to high image quality, high-resolution satellite images (HRSI) provide unprecedented direct georegistration accuracy, which have been enabled by accurate orbit determination technology. Direct georegistration is carried out by relating the determined position and attitude of camera to the ground target, i.e., projecting an image point to the earth ellipsoid using the collinearity equation. However, the apparent position of ground target is displaced due to the atmosphere and satellite velocity causing significant georegistration bias. In other words, optic ray from the earth surface to satellite cameras at 400~900km altitude refracts due to the thick atmosphere which is called atmospheric refraction. Velocity aberration is caused by high traveling speed of earth-observing satellites, approximately 7.7 km/s, relative to the earth surface. These effects should be compensated for accurate direct georegistration of HRSI. Therefore, this study presents the equation and the compensation procedure of atmospheric refraction and velocity aberration. Then, the effects are simulated at different image acquisition geometry to present how much bias is introduced. Finally, these effects are evaluated for Quickbird and WorldView-1 based on the physical sensor model.

Extraction of Ground Control Points from TerraSAR-X Data

  • Park, Jeong-Won;Hong, Sang-Hoon;Won, Joong-Sun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.328-331
    • /
    • 2008
  • It is possible to extract qualified ground control points (GCPs) solely from SAR data without published maps. TerraSAR-X is now in orbit and provides valuable data that have one of the highest spatial resolutions among civilian SAR systems. In this study, a sophisticated method for GCP coordinate extraction from TerraSAR-X stripmap mode data with a 3 m resolution was tested and the quality of the extracted GCPs was evaluated. An inverse-geolocation algorithm was applied to obtain GCPs from TerraSAR-X data. SRTM 90m DEM was used as an auxiliary data set for azimuth time correction of the SAR data. Mean values of the distance errors were 0.11 m and -3.96 m with standard deviations of 6.52 m and 5.11 m in easting and northing, respectively. The result is one of the best among GCPs possibly extracted from current civilian remote sensing systems. The extracted GCPs were used for geo-rectification of an IKONOS image, which demonstrated the applicability of the GCPs to geo-rectification of high resolution optic image. The method used in this study can be applied to KOMPSAT-5 for geo-rectification of high-resolution optic images acquired by KOMPSAT-2 or follow-up missions.

  • PDF

영상정보디스플레이용 비대칭 비구면 삼각 프리즘 광학계 연구 (Investigation of Asymmetric Aspherical Triangular Prism Optical System for Video Information Display)

  • 윤갑석;유경선;현동훈
    • 한국생산제조학회지
    • /
    • 제23권6호
    • /
    • pp.590-595
    • /
    • 2014
  • We have investigated anamorphic prism lenses with distortions of 0.3-0.5%. We designed the plastic triangular lens and confirmed the minimum resolution using MTF graphs. Also we confirmed that the SVGA optical system can realize a resolution of $864{\times}648$ 56 megapixels. A distortion of about 0.5% aberration appears in the maximum field, and a finite beam aberration of about $15{\mu}m$ is confirmed. We made a mold based on the design data and completed the prism lens through exodus molding. We confirmed the shape error (< $30{\mu}m$) and surface roughness (> 40 nm) of the three sides. We made the video-information-display prototype glasses using prism lens by measuring the performance, we determined the distortion aberration (0.3%) and SVGA resolution. Our approach will enable fabrication of a portable large-screen display device for glasses and sunglasses for the domestic market and, after 2015, for the world market.

A Test Result on the Positional Accuracy of Kompsat-3A Beta Test Images

  • Oh, Jae Hong;Seo, Doo Chun;Lee, Chang No
    • 한국측량학회지
    • /
    • 제34권2호
    • /
    • pp.133-142
    • /
    • 2016
  • KOMPSAT-3A (KOrea Multi-Purpose SATellite-3A) was launched in March 25 2015 with specification of 0.5 meters resolution panchromatic and four 2.2 meters resolution multi spectral sensors in 12km swath width at nadir. To better understand KOMPSAT-3A positional accuracy, this paper reports a test result on the accuracy of recently released KOMPSAT-3A beta test images. A number of ground points were acquired from 1:1,000 digital topographic maps over the target area for the accuracy validation. First, the original RPCs (Rational Polynomial Coefficients) were validated without any GCPs (Ground Control Points). Then we continued the test by modeling the errors in the image space using shift-only, shift and drift, and the affine model. Ground restitution accuracy was also analyzed even though the across track image pairs do not have optimal convergence angle. The experimental results showed that the shift and drift-based RPCs correction was optimal showing comparable accuracy of less than 1.5 pixels with less GCPs compared to the affine model.

Ground Receiving System for KOMPSAT-2

  • Kim, Moon-Gyu;Kim, Tae-Jung;Choi, Hae-Jin;Park, Sung-Og;Lee, Dong-Han;Im, Yong-Jo;Shin, Ji-Hyun;Choi, Myung-Jin;Park, Seung-Ran;Lee, Jong-Ju
    • 대한원격탐사학회지
    • /
    • 제19권3호
    • /
    • pp.191-200
    • /
    • 2003
  • Remote sensing division of satellite technology research center (SaTReC) , Korea advanced institute of science and technology (KAIST) has developed a ground receiving and processing system for high resolution satellite images. The developed system will be adapted and operated to receive, process and distributes images acquired from of the second Korean Multi-purpose Satellite (KOMPSAT-2), which will be launched in 2004. This project had initiated to develop and Koreanize the state-of-the-art technologies for the ground receiving system for high resolution remote sensing images, which range from direct ingestion of image data to the distribution of products through precise image correction. During four years development from Dec. 1998 until Aug. 2002, the system had been verified in various ways including real operation of custom-made systems such as a prototype system for SPOT and a commercialized system for KOMPSAT-1. Currently the system is under customization for installation at KOMPSAT-2 ground station. In this paper, we present accomplished work and future work.

차량용 근거리 계측을 위한 고분해능 FMCW 레이더의 구현 (Implementation of High Range Resolution FMCW Radar for Short-Range Automotive Applications)

  • 김찬헌;김수범;공영균;김영수
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2001년도 종합학술발표회 논문집 Vol.11 No.1
    • /
    • pp.324-327
    • /
    • 2001
  • In this paper, a 24GHz FMCW radar system which measures the range and the relative velocity of a vehicle in close range is described. The intended ranging accuracy is 15cm and a possible system concept to achieve this objective is presented. The VCO nonlinearity correction method using a reference delay-line and the data extrapolation algorithms based on AR(autoregressive) model are applied. The implemented system shows relatively satisfactory results in ranging accuracy.

  • PDF

Interleaved 나선 주사 영상 (Interleaved Spiral Scan Imaging)

  • 안창범;김휴정;신진교
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.98-99
    • /
    • 1998
  • In this paper, an interleaved spiral scan imaging is investigated for an ultra fast MR imaging. The interleaved spiral technique has relative advantage over single shot spiral imaging with improved resolution and less inhomogeneity-related artifact. An improved reconstruction algorithm is devised with DC-offset correction. Some preliminary experimental results are shown at 1.0 Tesla and 3.0 Tesla whole body MRI system.

  • PDF

세포교정영양요법(OCNT)을 이용한 장상피화생 환자 사례 연구 (Case Study of an Atrophic Gastritis Patient Using Ortho-Cellular Nutrition Therapy (OCNT))

  • 천능수
    • 셀메드
    • /
    • 제13권7호
    • /
    • pp.27.1-27.4
    • /
    • 2023
  • Objective: To report a case of improvement in atrophic gastritis using cell correction nutritional therapy. Methods: A 67-year-old Korean female with impaired digestive function and symptoms of abdominal bloating and hypochlorhydria. Results: Following the application of nutritional therapy, the severity of symptoms was alleviated, ultimately resulting in a complete resolution of atrophic gastritis. Conclusion: Nutritional therapy may be beneficial in alleviating symptoms and aiding in the treatment of patients presenting with atrophic gastritis symptoms.