• 제목/요약/키워드: resistivity ratio

검색결과 477건 처리시간 0.026초

Evaluation of grout penetration in single rock fracture using electrical resistivity

  • Lee, Hangbok;Oh, Tae-Min;Lee, Jong-Won
    • Geomechanics and Engineering
    • /
    • 제24권1호
    • /
    • pp.1-14
    • /
    • 2021
  • In this study, a new approach using electrical resistivity measurement was proposed to detect grout penetration and to evaluate the grouting performance for such as waterproof efficiency in single rock fracture. For this purpose, an electrical resistivity monitoring system was designed to collect multi-channel data in real time. This was applied to a system for grout injection/penetration using a transparent fracture replica with various aperture sizes and water-cement mix ratio. The electrical resistivity was measured under various grout penetration conditions in real time, which results were directly compared to the visual observation images of grout penetration/distribution. Moreover, the grouting success status after the curing process was evaluated by measuring the electrical resistivity in relation to changes in frequency in fracture cells where grout injection and penetration were completed. Consequently, it was determined that the electrical resistivity monitoring system could be applied effectively to the detection of successful penetration of grouting into a target area and to actual field evaluation of the grouting performance and long-term stability of underground rock structures.

Spontaneous Hall Effect in Amorphous Tb-Fe and Sm-Fe Thin films

  • Kim, T. W.;S. H. Lim;R. J. Gambino
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2000년도 International Symposium on Magnetics The 2000 Fall Conference
    • /
    • pp.337-345
    • /
    • 2000
  • The spontaneous Hall effect in amorphous Tb-Fe and Sm-Fe thin films, which possess excellent magnetic softness, is investigated in this work to seek a possibility of practical applications of these thin films as sensors. The resistivity of Tb-Fe thin films ranges from 180 to 250 Ωcm as the Tb content varies from 35 to 46 at. %. Tb-Fe thin films show negative Hall resistivity ranging from - 7.3 to - 5.0 Ωcm in the same composition range, giving the normalized resistivity ratio in the range of -4.1 to -2.0 %. On the other hand, the resistivity of Sm-Fe thin films ranges from 150 to 166 Ωcm as the Sm content varies from 22 to 31 at. %. Sm-Fe thin films show positive Hall resistivity which varies from 7.1 to 2.8 Ωcm in the same composition range, giving the normalized resistivity ratio in the range of 4.8 to 1.7 %. These values are significantly high compared with the values of other R-T alloys, Tb-Co alloys for example, where the highest reported value is 2.5 %. Between the two different sets of samples, Tb-Fe thin films with perpendicular anisotropy are considered to be more suitable for practical applications, since saturation is reached at a los magnetic field, approximately 2 kOe in a Tb$\sub$35.1/ Fe$\sub$64.9/ thin film, for example.

  • PDF

2층 대지모델에서 대지저항률의 비율에 따른 접촉전류에 의한 감전의 위험성 분석 (Analysis of Electric Shock Hazards due to Touch Current According to Soil Resistivity Ratio in Two-layer Earth Model)

  • 이복희;김태기;조용승;최종혁
    • 조명전기설비학회논문지
    • /
    • 제25권6호
    • /
    • pp.68-74
    • /
    • 2011
  • The touch or step voltages which exist in the vicinity of a grounding electrode are closely related to the earth structure and resistivity and the ground current. The grounding design approach is required to determine the grounding electrode location where the hazardous voltages are minimized. In this paper, in order to propose a method of mitigating the electric shock hazards caused by the ground surface potential rise in the vicinity of a counterpoise, the hazards relevant to touch voltage were evaluated as a function of the soil resistivity ratio $\rho_2/\rho_1$ for several practical values of two-layer earth structures. The touch voltage and current on the ground surface just above the test electrode are calculated with CDEGS program. As a consequence, it was found that burying a grounding electrode in the soil with low resistivity is effective to reduce the electric shock hazards. In the case that the bottom layer soil where a counterpoise is buried has lower resistivity than the upper layer soil, when the upper layer soil resistivity is increased, the surface potential is slightly raised, but the current through the human body is reduced with increasing the upper layer soil resistivity because of the greater contact resistance between the earth surface and the feet. The electric shock hazard in the vicinity of grounding electrodes is closely related to soil structure and resistivity and are reduced with increasing the ration of the upper layer resistivity to the bottom layer resistivity in two-layer soil.

Titanium nitride thin films for applications in thin film resistors

  • Cuong, Nguyen Duy;Kim, Dong-Jin;Kang, Byoung-Don;Yoon, Soon-Gil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.283-283
    • /
    • 2007
  • Titanium nitride thin films were deposited on $SiO_2$/Si substrate by rf-reactive magnetron sputtering. The structural and electrical properties of the films were investigated with various $N_2/(Ar+N_2)$ flow ratios (nitrogen/argon flow ratio). The resistivity as well as temperature coefficient of resistance (TCR) of the films strongly depends on phase structure. For the films deposited at nitrogen/argon flow ratio of below 5%, the resistivity increased with increasing nitrogen/argon flow ratios. However, the resistivity of the film deposited at nitrogen/argon flow ratio of 7% decreased drastically; it is even smaller than that of metal titanium nitride. A near-zero TCR value of approximately 9 ppm/K was observed for films deposited at nitrogen/argon flow ratio of 3%.

  • PDF

Filling of Cu-Al Alloy Into Nanoscale Trench with High Aspect Ratio by Cyclic Metal Organic Chemical Vapor Deposition

  • Moon, H.K.;Lee, S.J.;Lee, J.H.;Yoon, J.;Kim, H.;Lee, N.E.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.370-370
    • /
    • 2012
  • Feature size of Cu interconnects keep shrinking into several tens of nanometer level. For this reason, the Cu interconnects face challenging issues such as increase of electro-migration, line-width dependent electrical resistivity increase, and gap-filling difficulty in high aspect ratio structures. As the thickness of the Cu film decreases below 30 nm, the electrical resistivity is not any more constant, but rather exponential. Research on alloying with other elements have been started to inhibit such escalation in the electrical resistivity. A faint trace of Al added in Cu film by sputtering was reported to contribute to suppression of the increase of the electrical resistivity. From an industrial point of view, we introduced cyclic metal organic chemical vapor deposition (MOCVD) in order to control Al concentration in the Cu film more easily by controlling the delivery time ratio of Cu and Al precursors. The amount of alloying element could be lowered at level of below 1 at%. Process of the alloy formation was applied into gap-filling to evaluate the performance of the gap-filling. Voidless gap-filling even into high aspect ratio trenches was achieved. In-depth analysis will be discussed in detail.

  • PDF

콘크리트의 탄산화가 전기저항에 미치는 영향 (Influence of Carbonation of Concrete on Electrical Resistivity)

  • 윤인석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.27-33
    • /
    • 2014
  • 전기저항은 콘크리트의 내구성을 판단하기 위하여 빠르고 간단히 측정하여 활용될 수 있으나, 탄산화가 진행되면 콘크리트의 미세구조가 크게 변화하기 때문에 측정의 오차를 초래한다. 본 연구의 목적은 콘크리트의 탄산화가 전기저항에 미치는 영향을 분석하고 정량화 하는데 있다. 다양한 물시멘트비 조건에서 시험편을 제조하여 330일동안 탄산화 촉진을 시키면서 전기저항의 변화율을 고찰하였다. 탄산화된 콘크리트에서 전기저항 측정치가 높은 것으로 나타났으며, 이러한 경향은 탄산화가 진행됨에 따라 더욱 뚜렷한 경향을 보였다. 전기저항과 탄산화깊이와의 상관관계를 도출하였으며, 기중 상태 대비 탄산화된 콘크리트의 전기저항 비율은 일정한 탄산화깊이까지는 급격히 낮아지는 경향을 보였으나, 포화상태 대비 탄산화된 콘크리트의 전기비율은 탄산화 깊이와 선형관계를 보였다. 본 연구를 토대로 탄산화로 인하여 전기저항치의 측정오차를 보정할 수 있는데 실질적으로 활용될 수 있을 것으로 기대된다.

Correlation Between Bulk and Surface Resistivity of Concrete

  • Ghosh, Pratanu;Tran, Quang
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권1호
    • /
    • pp.119-132
    • /
    • 2015
  • Electrical resistivity is an important physical property of portland cement concrete which is directly related to chloride induced corrosion process. This study examined the electrical surface resistivity (SR) and bulk electrical resistivity (BR) of concrete cylinders for various binary and ternary based high-performance concrete (HPC) mixtures from 7 to 161 days. Two different types of instruments were utilized for this investigation and they were 4 point Wenner probe meter for SR and Merlin conductivity tester for bulk resistivity measurements. Chronological development of electrical resistivity as well as correlation between two types of resistivity on several days was established for all concrete mixtures. The ratio of experimental surface resistance to bulk resistance and corresponding resistivity was computed and compared with theoretical values. Results depicted that bulk and SR are well correlated for different groups of HPC mixtures and these mixtures have attained higher range of electrical resistivity for both types of measurements. In addition, this study presents distribution of surface and bulk resistivity in different permeability classes as proposed by Florida Department of Transportation (FDOT) specification from 7 to 161 days. Furthermore, electrical resistivity data for several HPC mixtures and testing procedure provide multiple promising options for long lasting bridge decks against chloride induced corrosion due to its ease of implementation, repeatability, non-destructive nature, and low cost.

증착조건에 따른 ZnO 박막의 전기적 특성 (Electrical characteristics of ZnO Thin Film according to deposition conditions)

  • 이동윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.131-135
    • /
    • 2003
  • Zinc Oxide(ZnO) thin films on Si (100) substrate were deposited by RF magnetron sputter with changing sputtering conditions such as argon/oxygen gas ratios, RF power, and substrate temperature, chamber pressure and target-substrate distance. To analyze a crystallographic properties of the films, $\theta/2\theta$ mode X-ray diffraction, SEM, and AFM analyses. C-axis preferred orientation, resistivity, and surface roughness highly depended on $Ar/O_2$ gas ratios. The resistivity of ZnO thin films rapidly increased with increasing oxygen ratio and the resistivity value of $9{\times}10^7{\Omega}cm$ was obtained at a working pressure of 10 mTorr with $Ar/O_2$=50/50. The surface roughness was also improved with increasing oxygen ratio and the ZnO films deposited with $Ar/O_2$=50/50 showed the excellent roughness value of $28.7{\AA}$.

  • PDF

3차원 구조를 고려한 전기비저항 탐사자료 해석을 통한 국내 저수지 제체 안전성 분석 (Safety Analysis of Reservoir Dikes in South Korea through the Interpretation of the Electrical Resistivity Data Considering Three-dimensional Structure)

  • 송성호;용환호;이규상;조인기
    • 지구물리와물리탐사
    • /
    • 제22권3호
    • /
    • pp.160-167
    • /
    • 2019
  • 저수지 제체는 3차원 전기비저항 구조로 구성되어 있기 때문에, 전기비저항 격자구조에 담수호의 수위변화에 따른 제체 내부의 침윤선 변동과 함께 담수호의 전기전도도가 고려되지 않는 경우 전기비저항 역산 결과가 왜곡될 수 있다. 이 연구에서는 3차원 전기비저항 탐사 모델링을 통하여, 저수지의 3차원 비저항 구조와 저수지 수위의 변화에 따른 제체 내부의 비저항 변화를 해석하였다. 이 분석 결과에 근거하여 국내 283개소 저수지를 대상으로 3차원 모델링에 의한 2차원 이론자료와 현장 2차원 탐사자료에 대한 역산 결과를 비교하였다. 마지막으로 두 역산의 비가 50% 이상이 되는 저수지를 추가 정밀조사 대상 저수지로 선정하였다.

오염토양의 전기 비저항치 변화 연구 (Electrical Resistivity Variations of Contaminated Soils)

  • 윤길림;이용길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2000년도 창립총회 및 춘계학술발표회
    • /
    • pp.84-89
    • /
    • 2000
  • Parametric studies based on laboratory pilot tests were performed to investigate the relationships between electrical resistivity and contaminated soil properties. Three kinds of sandy soils sampled and leachates from a industrial waste landfill were mixed to model the contaminated soils. Electrical resistivity of soils were measured by using a simulated resistivity cone penetrometer probe. In the experiments, the electrical resistivity were observed with changing the water content, void ratio, unit weight, degree of saturation, and concentration of the leachate. The test results show that the electrical resistivity of soils depends largely on the water content and the electrical property of pore water rather than unit weight and types of soils.

  • PDF