A Study of the Noise Discrimination by use of Different Sensors and Pulse Analysis Algorithms in Measuring Partial Discharge (부분방정 측정에서 센서 및 펄스 분석 알고리즘에 따른 노이즈 제거 연구)

  • Kim, Ji-Hong;Koo, Ja-Yoon;Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.183-188
    • /
    • 2006
  • Abstract - In order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis by use of a HFCT, pulse shapes measured by a resistive sensor and a HFCT were analyzed and adequate PA(pulse analysis) algorithms were studied. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively. As a result, it is possible to separate partial discharges and noises through the PA method using the $100kHz{\sim}20MHz$ frequency range HFCT. It is expected to apply the developed system to on-site PD measurements for the electric equipments.

Leakage Current Analysis of 18 kV Lighting Arrester (18kV 배전용 피뢰기의 누설전류 분석)

  • Park, J.N.;Lee, Y.H.;Shin, Y.S.;Su, J.M.;Jang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1906-1908
    • /
    • 2002
  • In general, ZnO lighting arrester are known to exhibit an increases in resistive current with time, the rate of increase being exacerbated with increasing applied voltage. In addition, since the resistive leakage current caused by deterioration of ZnO lighting arrester mainly caused an increase of the third harmonic component, thereby it is possible the arrester degradation diagnosis by measuring the third harmonic component in the total leakage current. So, in this paper, we presents a leakage current measuring and analysis system of 18[kV] ZnO lighting arrester.

  • PDF

Evaporation characteristics of materials from resistive heating sources(I) (저항가열원에 의한 물질의 증발특성(I))

  • 정재인;임병문;문종호;홍재화;강정수;이영백
    • Journal of the Korean institute of surface engineering
    • /
    • v.24 no.1
    • /
    • pp.25-30
    • /
    • 1991
  • The evaporation characteristics of Ag, Al, Au, Cr. Cu, In, Mg, Mn, Pb, Pd, Si, SiO, Sn, Ti and Zn with the various resistive heating sources have been studied. The employed sources are refractory metal (Mo, Ta and W) boats, W-wire, ceramic (usually Al2O3)-coated and -barriered refractory metal boats, and special boats such as baffled boats and intermetallic boats (nitride compound and graphite). We investigated the melting mode, evaporation rate at a specific power, and lifetime of the sources. A special boat holder is also discussed which is needed to cool the sources at a large heat capacity.

  • PDF

Development of the Neural Network Steering Controller based on Magneto-Resistive Sensor of Intelligent Autonomous Electric Vehicle (자기저항 센서를 이용한 지능형 자율주행 전기자동차의 신경회로망 조향 제어기 개발)

  • 김태곤;손석준;유영재;김의선;임영철;이주상
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.196-196
    • /
    • 2000
  • This paper describes a lateral guidance system of an autonomous vehicle, using a neural network model of magneto-resistive sensor and magnetic fields. The model equation was compared with experimental sensing data. We found that the experimental result has a negligible difference from the modeling equation result. We verified that the modeling equation can be used in simulations. As the neural network controller acquires magnetic field values(B$\_$x/, B$\_$y/, B$\_$z/) from the three-axis, the controller outputs a steering angle. The controller uses the back-propagation algorithms of neural network. The learning pattern acquisition was obtained using computer simulation, which is more exact than human driving. The simulation program was developed in order to verify the acquisition of the teaming pattern, teaming itself, and the adequacy of the design controller. The performance of the controller can be verified through simulation. The real autonomous electric vehicle using neural network controller verified good results.

  • PDF

A Resistive-Type Humidity Sensor Using PMMA Thin Film (PMMA를 이용한 저항형 습도감지소자)

  • Lee, Sung-Pil;Rim, Jae-Young;Yoon, Yeo-Kyoung
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.125-130
    • /
    • 1992
  • A resistive-type humidity sensors have been fabricated using cross-linked PMMA thin film as sensing material and their humidity characteristics have been investigated. The sensor coated of the cross-linked PMMA with PVA exhibited largely variation of resistance by increase of relative humidity and less than 3% of hysteresis. Furthermore, the fabricated sensor exhibited superior long-term stability. The response time of the PMMA humidity sensor was about 7 min. for adsorption and about 5 min. for desorption respectively.

  • PDF

The Study on Current Limiting Characteristic Analysis of Magnetic Shielding Type Fault Current Limiter

  • Lee, Jae;Lim, Sung-Hun;Kang, Hyeon-Gon;Ko, Seok-Cheol;Han, Byoung-Sung
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.235-240
    • /
    • 2002
  • In this paper, we investigated the current limiting characteristic in the magnetic shielding type fault current limiter(MSFCL). The circuit analysis was executed by using finite differential method(FDM). This paper suggests that the current limiting performance can be achieved in two ways (resistive and inductive one), according to design parameter. By comparing current limiting characteristics in two ways and surveying the important parameters which determine the operational way after fault occurs in the design of MSFCL, it is shown that the magnetic shielding type fault current limiter can be operated in either resistive or inductive way.

  • PDF

Negative Induced Polarization Effects for Two-Dimensional Structures (2차원 구조에 대한 음수의 유도분극 효과)

  • Kim, Hee Joon
    • Economic and Environmental Geology
    • /
    • v.21 no.2
    • /
    • pp.165-169
    • /
    • 1988
  • Negative induced polarization (IP) responses are examined for two-dimensional structures using a modeling technique with finite difference method. Percent frequency effect is used for IP parameter because it can be efficiently computed by a perturbation method. Thin conductive, polarizable overburden causes obvious negative IP responses on IP pseudosection. This fact means that IP responses from resistive, polarizable body below the overburden can be masked solely as a function of the resistivity distribution. Resistive, non-polarizable body below the overburden, however, can be detected by the negative IP responses.

  • PDF

Researching of the Tesla's Bifilar Coils, as a Sources of Electrical Energy

  • CHERVINSKY, L.;USENKO, S.;SPODOBA, M.
    • The Korean Journal of Food & Health Convergence
    • /
    • v.5 no.4
    • /
    • pp.19-23
    • /
    • 2019
  • In recent years, the Internet was a lot of information on the use of Tesla coils bifilar [1] in conjunction with induction cooker, for "free" electricity during power resistive load, including different incandescent lamps. With the development of scientific and technological progress, the demand for electricity in each year is increasing, and at the same time, the need to increase the capacity of electricity production, which entails large investments and, consequently, increase of prices for consumers. As before today, the search for free electric energy is an up-to-date and still open topic. The purpose of research - simplification of information on the possibility of using bifilar coils as an electric current source in conjunction with induction cooker. Consequently, it can be concluded from the above that the use of Tesla coils in combination with induction cooker has very low k.k.d. and it is not possible to obtain excessive electric energy using the Tesla coil under the connection schemes considered.

The Simulation on the Design and the Characteristic of Shielded Inductive $High-T_c$ Superconducting Fault Current Limiter (차폐유도형 고온초전도 전류제한기의 설계 및 특성시뮬레이션)

  • Im, Seong-Hun;Choe, Myeong-Ho;Lee, Hyeon-Su;Han, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.173-178
    • /
    • 1999
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed. After determining parameters fo design for superconducting tube, iron core and primary coil, simple power system composed of shielded inductive FCL was simulated by the numerical analysis. The currents flowing under the fault condition could be limited below 50 A successfully. It was suggested that as the important factors of operational characteristics, the turns of primary coil and size of iron core play a major role for whether the shielded inductive SCFCL operated as inductive type or resistive type FCL.

  • PDF