• 제목/요약/키워드: resistance of load

검색결과 2,437건 처리시간 0.027초

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

지하공간의 화재하중을 고려한 슬래브 내화 가열 실험 (A Experimental Study on the slab of fire resistance considering the fire load in Underground space)

  • 강승구;김동준;이재영;原田和典;한병찬;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.327-329
    • /
    • 2012
  • The validity of the numerical model used in the program is established by comparing the prediction from the computer program with results from full-scale fire resistance tests. Details of fire resistance experiments carried out on reinforced concrete slab, together with results, are presented. The results obtained from experimental test indicated in that the proposed numerical model and the implemented codes are accurate and reliable.

  • PDF

탄소섬유와 L형강을 이용한 벽-슬래브 접합부의 보강성능 (Structural Performance of Seismic Resistance Capacity of Carbon Sheet-Angle Retrofitting Method in Wall-Slab Joint)

  • 노공기;박태원;박현수;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.65-68
    • /
    • 2004
  • In the seismical capacity evaluation for RC structure wall-slab joint is very important factor. Because lateral load is resistance element and gravity load resistance element are acted mutually in the wall-slab joint. In this paper, to improve the seismic capacity of the wall-slab joint in the existing wall type apartments experiment which improve and retrofit a seismic capacity by unequal angle bracing and carbon sheet attachment are carried out. These methods are also economic and simple in mitigating seismic hazard, improve earthquake-resistance performance, and reduce risk level of building occupants. From the experimental results, the change of strength, degration of stiffness, and energy dissipation are evaluated. It can be concluded that these methods are effective in improving the seismic performance.

  • PDF

양방향재하시험에서 재하장치 위치 선정에 관한 연구 (A Study of Point Selection for Loading Cells in Bi-directional Pile Load Test)

  • 윤민승;김준우;김명학
    • 한국지반환경공학회 논문집
    • /
    • 제14권10호
    • /
    • pp.11-16
    • /
    • 2013
  • 양방향재하시험의 성공여부는 상향력과 하향력의 균형을 이룰 수 있는 재하장치 위치 선정에 달려있다. 상향력과 하향력의 균형을 이루기 위해서는 발휘되는 단위주면마찰력과 단위선단지지력의 산정이 중요한데, 국내에서 시행되는 양방향재하시험은 주로 사용말뚝에 적용되어 극한지지력까지 재하되지 않고 설계지지력을 확인하는 것이 일반적이다. 하지만 국내 외 제안된 암반층의 극한단위주면마찰력 및 허용단위주면마찰력 산정식은 암반의 일축압축강도를 기반으로 되어있고, 또한 국내 풍화암층과 RQD가 극히 낮은 연암층은 일축압축강도시험을 할 수 있는 코아를 얻기가 어려워 적용이 어려운 실정이다. 따라서 이 연구에서는 국내에서 시행되었던 양방향재하시험에서 얻은 각 지층별 발휘된 단위주면마찰력과 환산된 SPT N/cm과 관계도표를 제안하고 이 관계도표를 이용하여 실제 국내 현장의 양방향재하시험을 위한 상향력과 하향력의 균형위치를 선정하였다. 또한 선정된 균형위치에 양방향재하장치를 설치한 후 재하시험을 실시하여 측정된 각 지층의 발휘된 단위주면마찰력 값들과 균형위치 선정 시 적용한 관계도표의 값들을 비교하여 관계도표의 적정성을 분석하였다. 분석결과 풍화토층과 풍화암층에서는 거의 유사한 결과를 보였고, 연암층에서는 재하장치 상부연암층과 하부연암층에서 발휘된 측정값(상부 $1,151kN/m^2$, 하부 $1,500kN/m^2$)의 평균값($1,325kN/m^2$)도 산정값($1,250kN/m^2$)과 큰 차이를 보이지 않아 관계도표는 적정한 것으로 판단되었다.

압전특성 및 부하변화에 따른 압전트랜스포머의 전기적 특성 (Electrical Characteristics of the Piezoelectric Transformer as a Function of Piezoelectric Properties and Load Variations)

  • 민석규;윤광희;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.289-296
    • /
    • 2001
  • The piezoelectric transformers of 2.0x10x48 ㎣ size were fabricated with PSN-PMN-PZT(T10 and PNW-PMN-PZT(T2) composition ceramics. Effects of micro structural and piezoelectric properties on the electrical characteristics of the piezoelectric transformers were investigated. Under the fixed output power of 6 W, temperature rise of T1 transformer at the optimum load was smaller than T2 one because of fine grain size effect. Voltage step-up ratio of T1 transformer showed higher value than T2 one T1 transformer showed an excellent properties with voltage step-up ratio of 12.41, efficiency of 95.23% and temperature rise of 7.2$^{\circ}C$ at 200㏀ load resistance. And also, T2 transformer showed an excellent properties with voltage step up ratio of 9.81, efficiency of 95.51% and temperature rise of 9$^{\circ}C$ at 150㏀ load resistance.

  • PDF

풍화 화연토와 loess의 붕괴특성 비교 (The Comparison of Collapsible Characteristics on Decomposed Granite Soil and Loess)

  • 도덕현
    • 한국지반공학회지:지반
    • /
    • 제2권1호
    • /
    • pp.7-14
    • /
    • 1986
  • The structure of the collapsible soils, such as decomposed granite soil and loess, were examined by the odeometer test, SEM & XES analysis and static & cyclic triaxial test, and hove this structure have influences upon the collapsible behaviour under static and cyclic load was investigated. The study results obtained are as follows; 1. The macropores space of decomposed granite soil (rd=1.50g/cm3) and loess (rd=1.43g/cm3) used in this test were well developed, and showed the behaviour of collapsible soil. 2. Collapsible soil has high resistance on the strain under natural moisture content, however, the resistance on the strain was sharply decreased by the absorption and increasing load since its special structure was destructed. 3. Under the static load, the strain of collapsible soil was high by the viscous flow of the cyclic bonds with time lapse, but Infer the cyclic load, the strain of collapsible soil was low since the tinge needed to destruct the bonding force of clay was not enough. 4. The understanding about the cyclic behaviour of collapsible soil may be helpful to predict the elastic & residual strain of the foundations by the earthquake together with the damage by the additional failure.

  • PDF

권상용량 증가에 따른 컨테이너 크레인의 내풍특성 비교 (A Comparison of the Wind Resistance Characteristic of a Container Crane According to the Increase to the Lifting Capacity)

  • 이성욱;김형훈;한동섭;한근조;김태형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.204-209
    • /
    • 2007
  • This study was carried out to analyze the effect of wind load on the structural stability of a container crane according to the increase of the lifting capacity using wind tunnel test and provided a container crane designer with data which can be used in a wind resistance design of a container crane assuming that a wind load at 75m/s wind velocity is applied on a container crane. Data acquisition conditions for this experiment were established in accordance with the similarity. The scale of a container crane dimension, wind velocity and time were chosen as 1/200, 1/13.3 and 1/15. And this experiment was implemented in an Eiffel type atmospheric boundary-layer wind tunnel with $11.52m^{2}$ cross-section area. Each directional drag and overturning moment coefficients were investigated.

  • PDF

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

부저항발진기의 최대주파수 해석(I보) (Analysis of Negative Resistance Maximum Oscillating Frequeney)

  • 김영권;서정홍
    • 대한전자공학회논문지
    • /
    • 제6권2호
    • /
    • pp.6-20
    • /
    • 1969
  • 부저항소자인 턴넬다이오드와 수동선형부하로 부저항발진기를 구성하고 수동부하를 가변하여 주파수최대화에 관해서 연구했다. 이론적인 해석과 복소평면상의 임피이던스 궤적을 도시하고 병렬-RL부하와 저항부하의 두 경우의 최대발진주파수를 측정하여 두 경우의 실험결과를 보면 병렬-RL부하의 폭이 훨씬 높은 주파수를 발진하는 것을 알았다.

  • PDF

마그네슘/공기연료전지의 과도특성에 관한 연구 (Transient Characteristics of Mg/Air Fuel Cell)

  • 김용혁
    • 전기학회논문지P
    • /
    • 제65권3호
    • /
    • pp.210-215
    • /
    • 2016
  • The transient characteristics of the Mg/Air fuel cell were ascribed to the load current, electrolyte concentrations, air electrode area and electrode distance. It was found that transient phenomena occurred in the load current, which is due to activate of the oxidation and reduction reaction process. The transient time increase with the load current increase. The transient characteristics were investigated with regard to internal resistance. The maximum power output analysis was employed in order to explain the delayed action under various experimental conditions. The internal resistances had a significant effect on the transient characteristics. The transient curves thus obtained were in almost agreement with internal resistance characteristics.