• Title/Summary/Keyword: resistance loss

Search Result 1,441, Processing Time 0.029 seconds

Thermal buckling resistance of simply supported FGM plates with parabolic-concave thickness variation

  • Benlahcen, Fouad;Belakhdar, Khalil;Sellami, Mohammed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.29 no.5
    • /
    • pp.591-602
    • /
    • 2018
  • This research presents an investigation on the thermal buckling resistance of FGM plates having parabolic-concave thickness variation exposed to uniform and gradient temperature change. An analytical formulation is derived and the governing differential equation of thermal stability is solved numerically using finite difference method. A specific function of thickness variation is introduced where it controls the parabolic variation intensity of the thickness without changing the original material volume. The results indicated that the loss ratio in buckling resistance is the same for any gradient temperature profile. Influencing geometrical and material parameters on the loss ratio in the thermal resistance buckling are investigated which may help in design guidelines of such complex structures.

Effect of column loss location on structural response of a generic steel moment resisting frame

  • Rezvani, Farshad Hashemi;Jeffers, Ann E.;Asgarian, Behrouz;Ronagh, Hamid Reza
    • Steel and Composite Structures
    • /
    • v.25 no.2
    • /
    • pp.217-229
    • /
    • 2017
  • The effect of column loss location on the structural response of steel moment resisting frames (MRF) is investigated in this study. A series of nonlinear static and dynamic analyses were performed to determine the resistance of a generic frame to an arbitrary column loss and detect the structural members that are susceptible to failure progression beyond that point. Both force-controlled and deformation-controlled actions based on UFC 4-023-03 and ASCE/SEI 41-06 were implemented to define the acceptance criteria for nine APM cases defined in this study. Results revealed that the structural resistance against an arbitrary column loss in the top story is at least 80% smaller than that of the bottom story. In addition, it was found that the dynamic increase factor (DIF) at the failure point is at most 1.13.

A Study on the Properties of Low-Heat Cement Concrete (저발열시멘트 콘크리트의 기초적 성질에 대한 연구)

  • 문한영;김성수;신화철;강석화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.57-60
    • /
    • 1997
  • The properties of Low-heat cement are especially in lower heat of hydration than that of other types of cement. In other respect, Low-heat concrete is more advantageous than OPC concrete in chemical resistance, long term age compressive strength, slump loss and resistance to seawater. This paper deals with 28 days age compressive strength and slump loss by elapsed time of mortar and concrete that made with Low-heat cement and 3 types of other cement.

  • PDF

Evaluation of Two Species of Soft Wood Decay Resistance for Heat-Treated Wood Using the Catalyst (H2SO4)

  • Won, Kyung-Rok;Hong, Nam-Euy;Jung, Su-Young;Kim, Byung-Ro;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.195-201
    • /
    • 2017
  • This study was conducted to evaluate the resistance of heat-treated wood using the catalyst to decay caused by fungi for sapwood and heartwood of two tree species, Korean red pine (Pinus densiflora) and Japanese larch (Larix kaempferi), respectively. Wood samples were immersed for 10 min in sulfuric acid (7.5%) and then heat-treated at $130^{\circ}C$ for 90 min. Fomitopsis palustris, a brown-rot fungus, was used to examine the decay resistance of Korean red pine and Japanese larch wood. Weight and density of wood from the all conditions increased after heat treatment using the catalyst. Weight loss after decay resistance test was also dropped with a heat treatment. The lowest weight loss indicated at heat-treated heartwood of Japanese larch. Heat treatment using the catalyst effectively increased the resistance of wood to decay caused by fungi.

Power Loss Characteristics according to Winding Method of High Frequency Transformer (고주파 트랜스포머의 권선기법 따른 손실특성)

  • Kim, Il-Nam;Yoon, Shin-Yong;Lee, Gong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.49-51
    • /
    • 2004
  • This paper researched the power loss characteristics according to winding method of high frequency transformer. Power loss was analyzed by PExprt using FEM software. The ferrite core model for analysis be used the EE type. Transformer model objected type applied to flyback converter. Therefore, analysis result was obtained the many parameter of DC, AC resistance, leakage inductance, copper loss, core loss, and temperature etc.

  • PDF

Three-dimensional finite element analysis on intrusion of upper anterior teeth by three-piece base arch appliance according to alveolar bone loss (치조골 상실에 따른 three-piece base arch appliance를 이용한 상악전치부 intrusion에 대한 3차원 유한요소법적 연구)

  • Ha, Man-Hee;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.209-223
    • /
    • 2001
  • At intrusion of upper anterior teeth in patient with periodontal defect, the use of three-piece base arch appliance for pure intrusion is required. To investigate the change of the center of resistance and of the distal traction force according to alveolar bone height at intrusion of upper anterior teeth using this appliance, three-dimensional finite element models of upper six anterior teeth, periodontal ligament and alveolar bone were constructed. At intrusion of upper anterior teeth by three-piece base arch appliance, the following conclusions were drawn to the locations of the center of resistance according to the number of teeth, the change of distal traction force for pure intrusion and the correlation to the change of vertical, horizontal location of the center of resistance according to alveolar bone loss. 1. When the axial inclination and alveolar bone height were normal, the anteroposterior locations of center of resistance of upper anterior teeth according to the number of teeth contained were as follows : 1) In 2 anterior teeth group, the center of located in the mesial 1/3 area of lateral incisor bracket. 2) In 4 anterior teeth group. the center of resistance was located in the distal 2/3 of the distance between the bracket of lateral incisor and canine. 3) In 6 anterior teeth group, the center of resistance was located in the central area of first premolar bracket .4) As the number of teeth contained in anterior teeth group increased, the center of resistance shifted to the distal side. 2. When the alveolar bone height was normal, the anteroposterior position of the point of application of the intrusive force was the same position or a bit forward position of the center of resistance at application of distal traction force for pure intrusion. 3. When intrusion force and the point of application of the intrusive force were fixed, the changes of distal traction force for pure intrusion according to alveolar bon loss were as follows :1) Regardless of the alveolar bone loss, the distal traction force of 2, 4 anterior teeth groups were lower than that of 6 anterior teeth group. 2) As the alveolar bone loss increased, the distal traction forces of each teeth group were increased. 4. The correlations of the vertical, horizontal locations of the center of resistance according to maxillary anterior teeth groups and the alveolar bone height were as follows : 1) In 2 anterior teeth group, the horizontal position displacement to the vortical position displacement of the center of resistance according to the alveolar bone loss was the largest. As the number of teeth increased, the horizontal position displacement to the vertical position displacement of the center of resistance according to the alveolar bone loss showed a tendency to decrease. 2) As the alveolar bone loss increased, the horizontal position displacement to the vertical position displacement of the center of resistance regardless of the number of teeth was increased.

  • PDF

A Study on Alkali-Treatment of Polyester/silk Union Cloth (폴리에스테르/견 교직물의 알칼리 감량가공에 관한 연구)

  • Lee, Seok-Young;Park, Sung-Woo;Seo, Mal-Yong;Cho, Kyu-Min;Gu, Kang
    • Textile Coloration and Finishing
    • /
    • v.10 no.5
    • /
    • pp.39-47
    • /
    • 1998
  • The purpose of this study was to investigate the effect of alkali treatment on EG solution of polyester/silk union cloth(P/S cloth) . Tensile strength, moisture regain, crease resistance, and reduction ratio of the treated P/S cloth were measured. The results of this study were as follows : 1) The weight loss of P/S cloth treated with EG solution was three times higher than those of P/S cloth treated with $H_2O$. The weight loss of P/S cloth was increased greatly with increasing concentration of NaOH, temperature, and time. Favorable weight reduction of treating condition could be obtained when lower concentration of NaOH was used with longer time. 2) If it was added $H_2O$ on EG solution, weight loss of polyester increased, while those of silk decreased. In addition, decreasing ratio of tensile strength warp direction (polyester) was lower, while those of weft direction(silk) was higher. 3) Moisture regain of P/S cloth treated with EG solution increased with weight loss up to 10% . Crease resistance of P/S cloth was the highest at weight loss of 10~15%.

  • PDF

Effect of the Neighboring Tape′s AC Currents on Transport Current Loss of a Bi-2223 Tape (인접 교류전류가 Bi-2223테이프의 통전손실에 미치는 영향)

  • 류경우;최병주
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.3
    • /
    • pp.251-256
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current simultaneously. AC loss taking into account such real applications is a crucial issue for power applications fo the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1./5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured trasprot losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents.The trasport losses do not depend on the frequency of the neighboring tape's AC currents but is arrangements in the range of small current especially.

  • PDF

A COMPARATIVE STUDY ON THE WEAR RESISTANCE OF POLYMERIC VENEERING MATERIALS (치관 전장용 레진의 내마모성에 대한 비교연구)

  • Youn, Soo-Sun;Lee, Sun-Hyung;Yang, Jae-Ho;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.33-43
    • /
    • 1986
  • The purpose of this study was to compare the wear resistance of heat pressure-cured microcomposite(SR-Isosit-N), photo-cured microcomposite(Dentalcolor), unfilled heat-cured resin(Thermojel) and that of human enmel. Specimens were made with specially designed die and finally polished with #3,000 diamond paste. After 100,000 strokes of tooth brushing at electric tooth-brushing machine, mean thickness loss of each specimen was measured by using surface profile and integration. The results were as follows 1. Mean thickness loss were $84.3{\pm}27.3{\mu}m$ in unfiled heat-cured resin, $9.4{\pm}2.5{\mu}m$ in photocured microcomposite, $7.6{\pm}2.1{\mu}m$ in heat.pressure-cured microcomposite and $0.97{\pm}0.42{\mu}m$ in enamel. 2. Heat.pressure-cured microcomposite and photo-cured microcomposite had no difference in mean thickness loss(p>0.05). 3. Unfilled resin and microcomposite had much differences in mean thickness loss (p<0.005). 4. ha resins used in this experiment had too much mean thickness loss as compared with enamel (p<0.005).

  • PDF

Dielectric loss of silicone oils for insulation due to the increase of viscosity (점도증가에 따른 절연용 실리콘유의 유전손실)

  • 이용우;조경순;김왕곤;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.587-593
    • /
    • 1995
  • Silicone oils used insulating substances exhibit the both of organic and inorganic properties, and it has many superior characteristics such as the high thermal resistance and low thermal oxidation level when compared to other insulation oils. In order to investigate the dielectric loss due to the increase of viscosity, silicone oils of viscosity 1, 2, 5[cSt] had been chosen as the specimen and experiment has been performed in the temperature range of -70[.deg. C] - 65[.deg. C] and frequency range of 30 - 1*10$\^$5/[Hz]. As a result, the linear decrease of loss at low frequency region in high temperature was due to the influence of applying frequency, whereas the increase of loss at high frequency region was contributed by electrode's resistance. And increasing viscosity, the activation energy increased from 3.77[kcal/mole] to 7.21[kcal/mole]. The dipole moment of specimen was become clear 1.48 - 2.26[debyel in high temperature region(5 - 65[.deg. C]) and 1.05 - 1.80[debye] in low temperature region (-70 - -25[.deg. C])respectively.

  • PDF