• Title/Summary/Keyword: resin penetration

Search Result 163, Processing Time 0.023 seconds

Pit and fissure sealing - Advanced technique (치면열구전색술 - Advanced technique)

  • Lee, Sang-Ho
    • The Journal of the Korean dental association
    • /
    • v.49 no.1
    • /
    • pp.22-32
    • /
    • 2011
  • This paper reviewed the following subheadings and a few selected references in each section were discussed: ${\cdot}$ Sealant placed over caries; is it possible? Initial caries which is not sticky during proving is possible to be placed with sealants. ${\cdot}$ Prophylaxis of fissure; which method is most effective? Mechanical preparation with fissurotomy or resin polishing bur is one of the most effective method to clean the pit and fissure. ${\cdot}$ Glassionomer cement as a sealant; GIC, wheather it released fluoride or not, cannot be as cost-effective as resin-based sealants. ${\cdot}$ Sealant products; Color(white vs opaque), fluoride(containing vs not), filler component(filled vs non-filled) do not influenced the quality and retention of sealants. ${\cdot}$ Use of intermediate bonding agent to improve retention; Intermediate bonding may increase the retention rate of sealants ${\cdot}$ Penetration method of sealants; Several methods including waiting before light curing are recommended.

Chemical Evaluation of Corrosion Resistance for Stainless-Steel Plate Wet-Coated by Alumina-Fluoro Composite Coatings (알루미나-불소 복합 코팅제로 습식코팅된 스텐레스 강판의 화학 내식성 평가)

  • Jung, Ha-Young;Kim, Dae Sung;Lee, Seung-Ho;Lim, Hyung Mi;Kim, Kun;Jung, Min-Kyu
    • Korean Journal of Materials Research
    • /
    • v.22 no.12
    • /
    • pp.643-649
    • /
    • 2012
  • Coatings composited with alumina and Perfluoro alkoxyalkane (PFA) resin were deposited on stainless steel plate (SUS304) to further improve corrosion resistance. Plate (ca. $10{\mu}m$) and/or nanosize (27~43 nm) alumina used as inorganic additives were mixed in PFA resin to make alumina-fluoro composite coatings. These coatings were deposited on SUS304 plate with wet spray coating and then the film was cured thermally. According to the amount and ratio of the two kinds of alumina having plate morphology and nano size, corrosion resistance of the film was evaluated under strong acids (HF, HCl) and a strong base (NaOH). The film prepared with the addition of 5~10 wt% alumina powders in PFA resin showed corrosion resistance superior to that of pure PFA resin film. However, for the film prepared with alumina content above 10 wt%, the corrosion resistance did not improve with the physical properties, such as surface hardness and adhesion. The film prepared with plate/nanosize (weight ratio = 1/2) alumina especially enhanced the surface hardness and corrosion resistance. This can be explained as showing that the plate and the nanosize alumina dispersed in PFA resin effectively suppressed the penetration of cations and anions due to the long penetration length and fewer defects that accompany the improved surface hardness under a serious environment of 10% HF solution for over 120 hrs.

AN EXPERIMENTAL STUDY ON THE ETCHING PATTERNS AND THE PENETRATION OF THE COMPOSITE RESIN TO HUMAN DECIDUOUS ENAMEL ETCHED WITH PHOSPHORIC ACID (인산(燐酸) 부식(腐蝕)에 의(依)한 유치(乳齒) 표면(表面) 변화(變化) 및 복합(複合)레진 침투(浸透)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Shin, Wan-Young;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.10 no.1
    • /
    • pp.85-93
    • /
    • 1983
  • In one group that tested for the effects of grinding and etching on the deciduous teeth, S.E.M. examination on the ground or unground labial surface of deciduous maxillary central incisors were made after etching procedure with 40% phosphoric acid for 60 secs., 120 secs., 180 sees. each. In another group that tested for the degree of resin penetration to the ground and etched deciduous teeth, composite resin application was done to the ground deciduous maxillary central incisors that had been acid-etched for 30 secs., 60 secs., 90 sees., 120 sees., 180 secs. each. The tooth-resin specimens were cut at the middle 1/3 of the crown by 2mm thickness, and the adjacent tooth materials were demineralized by 10% hydrochloric acid, the author observed the tags of the resin replica with S.E.M.. Following results were obtained. 1. After 40% phosphoric acid etching, the unground deciduous enamel surface showed various types of etching pattern. 2. For the formation of regular micropores on deciduous enamel surface by acid etching with 40% phosphoric acid, the time over 120 secs. should be requested. 3. After 40% phosphoric acid etching, the ground deciduous enamel surface showed the same etching pattern that has been a preferential removal of prism peripheries despite different etching time. 4. On the ground group that etched over 60 secs. to 180 secs., the length of tags was $5{\mu}m$ to $8{\mu}m$, with a mean of $7{\mu}m$.

  • PDF

IN VITRO STUDY ON MARGINAL LEAKAGE OF COMPOSITE RESIN INLAY RESTORATIONS (광중합 복합레진 INLAY 수복물의 변연누출에 관한 실험적 연구)

  • Yoo, Je-Kug;Bae, Jeong-Sik;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.85-98
    • /
    • 1988
  • The primary aim of this study was to access the degree of marginal leakage in composite resin inlay restorations. Class V cavities were prepared on sixty extracted premolars. They were classified as control group and experimental group 1, 2 and each group was filled with BIS-FIL $I^{(R)}$ and $Silux^{(R)}$ composite resins. In the control group, the composite resin was inserted directly, the experimental group 2 was inserted as composite resin inlay after heat treatment on $125^{\circ}C$, 10 minutes. Then thermocycling was performed 1000 times. After staining with 1% Basic Fuchsin, they were cut in Buccolingual direction and the degree of penetration of the dye was examined under L/M. The following results were obtained : 1. In occlusal margin area, difference in marginal leakage was not observed in all groups. 2. In gingival margin area, cavities filled with composite resin inlay was less marginal leakage than filled directly in BIS-FIL $I^{(R)}$ group, and statistical significant difference was not existed in $Silux^{(R)}$ group. 3. The statistical significance was not existed between composite resin inlay and composite resin inlay heated secondarily. 4. In all groups, gingival margin area reveals more marginal leakage than occlusal margin area and statistical significance was existed.

  • PDF

EFFECT OF LIGHT IRRADIATION MODES ON THE MARGINAL LEAKAGE OF COMPOSITE RESIN RESTORATION (광조사 방식이 복합레진 수복물의 변연누출에 미치는 영향)

  • 박은숙;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • The aim of this study was to investigate the influence of four different light curing modes on the marginal leakage of Class V composite resin restoration. Eighty extracted human premolars were used. Wedge-shaped class Y cavities were prepared on the buccal surface of the tooth with high-speed diamond bur without bevel. The cavities were positioned half of the cavity above and half beyond the cemento-enamel junction. The depth, height, and width of the cavity were 2 mm, 3 mm and 2 mm respectively. The specimens were divided into 4 groups of 20 teeth each. All the specimen cavities were treated with Prime & Bond$^{R}$ NT dental adhesive system (Dentsply DeTrey GmbH, Germany) according to the manufacturer's instructions and cured for 10 seconds except group VI which were cured for 3 seconds. All the cavities were restored with resin composite Spectrum$^{TM}$ TPH A2 (Dentsply DeTrey GmbH, Germany) in a bulk. Resin composites were light-cured under 4 different modes. A regular intensity group (600 mW/${cm}^2$, group I) was irradiated for 30 s, a low intensity group (300 mW/${cm}^2$, group II) for 60 s and a ultra-high intensity group (1930 mW/${cm}^2$, group IV) for 3 s. A pulse-delay group (group III) was irradiated with 400 mW/${cm}^2$ for 2 s followed by 800 mW/${cm}^2$ for 10 s after 5 minutes delay. The Spectrum$^{TM}$ 800 (Dentsply DeTrey GmbH, Germany) light-curing units were used for groups I, II and III and Apollo 95E (DMD, U.S.A.) was used for group IV. The composite resin specimens were finished and polished immediately after light curing except group III which were finished and polished during delaying time. Specimens were stored in a physiologic saline solution at 37$^{\circ}C$ for 24 hours. After thermocycling (500$\times$, 5-55$^{\circ}C$), all teeth were covered with nail varnish up to 0.5 mm from the margins of the restorations, immersed in 37$^{\circ}C$, 2% methylene blue solution for 24 hours, and rinsed with tap water for 24 hours. After embedding in clear resin, the specimens were sectioned with a water-cooled diamond saw (Isomet$^{TM}$, Buehler Co., Lake Bluff, IL, U.S.A.) along the longitudinal axis of the tooth so as to pass the center of the restorations. The cut surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan) at ${\times}$25 magnification, and the images were captured with a CCD camera (GP-KR222, Panasonic, Japan) and stored in a computer with Studio Grabber program. Dye penetration depth at the restoration/dentin and the restoration/enamel interfaces was measured as a rate of the entire depth of the restoration using a software (Scion image, Scion Corp., U.S.A.) The data were analysed statistically using One-way ANOVA and Tukey's method. The results were as follows : 1. Pulse-Delay group did not show any significant difference in dye penetration rate from other groups at enamel and dentin margins (p>0.05) 2. At dentin margin, ultra-high intensity group showed significantly higher dye penetration rate than both regular intensity group and low intensity group (p<0.05). 3. At enamel margin, there were no statistically significant difference among four groups (p>0.05). 4. Dentin margin showed significantly higher dye penetration rate than enamel margin in all groups (p<0.05).

  • PDF

An Experimental Study on the Compressive Strength of Cement Mortar mixing Anion Exchange Resin (음이온교환수지 혼입 시멘트 모르타르의 압축강도에 관한 실험적 연구)

  • Jeong, Do-Hyun;Lee, Yun-Su;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.54-55
    • /
    • 2018
  • Reinforced concrete is a building material that is generally used in modern society. Securing the performance of reinforced concrete is directly connected to the durability and longevity of the building. One of the major factors that deteriorate the durability of concrete is harmful ion. Recently, the quality and improvement method of reinforced concrete for penetration of harmful ion has been studied. In this study, the bead type ion exchange resin is substituted for 0%, 3%, and 6% of the fine aggregate volume in the mortar. The speciments underwent underwater curing and were checked for compressive strengths of 3 days and 28 days. From the results of compressive strength, it can be seen that the higher the substitution ratio of the ion exchange resin, the lower the early strength and long-term strength development, especially the early strength development.

  • PDF

Corrosion-Inhibition and Durability of Polymer-Modified Mortars Using Bisphenol A and F Type Epoxy Resin with Calumite (비스페놀 A 및 F형 에폭시수지와 칼루마이트를 병용한 폴리머 시멘트 모르타르의 방청성 및 내구성)

  • Kim, Joo-Young;Kim, Wan-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.517-524
    • /
    • 2014
  • Nitrite-Type hydrocalumite (calumite) is a material that can adsorb chloride ions ($Cl^-$) that cause corrosion of reinforce bars and liberate the nitrite ions ($NO_2{^-}$) that inhibit corrosion in reinforced concrete. In this study, polymer-modified mortars using two types of epoxy resin with calumite are prepared with various polymer binder-ratios of 0, 5, 10, 15, 20% and calumite contents of 0, 5%. The specimens are tested for chloride ion penetration, carbonation, drying shrinkage and corrosion inhibition. As a result, the chloride ion penetration and carbonation depth of PMM using epoxy resin somewhat increases with increasing calumite contents, but those remarkably decreases depending on the polymer-binder ratios. The 28-d drying shrinkage shows a tendency to decrease with increasing polymer-binder ratio and calumite content. Unmodified mortars with calumite content of 5% did not satisfy quality requirement by KS. However, it was satisfied with KS requirement by the modification of epoxy resin in cement mortar. On the whole, the carbonation and chloride ion penetration depth of epoxy-modified mortars with calumite is considerably improved with an increase in the polymer-binder ratio regardless of the calumite content, and is remarkably improved over unmodified mortar. And, the replacement of the portland cement with the calumite has a marked effect in the corrosion-inhibiting property of the epoxy-modified mortars.

Analyses on Environment-friendliness of Root Barrier Materials based on Fish Toxicity Test (어독성 실험에 따른 방근재 친환경 특성 분석)

  • Woo, Ji-Keun;Kim, Sung-Kyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.4
    • /
    • pp.42-51
    • /
    • 2010
  • The purpose of this study is to analyze the characteristics of environment-friendliness of Root Barrier materials based on comprehensive experiments on harmfulness of Root Barrier materials and fish toxicity of Oryzias latipes mortality to verify eco-toxicity of each method of construction and Root Barrier material, which are to be applied by taking eco-toxicity into account when building ecological flows in upper areas on natural and artificial grounds. As a result, the following conclusions have been reached in this study: 1. In regard of the harmfulness analyzed, each material showed a different result of analytical value in each lab tank. Compared to lab tank, pH (la), DO (lb), T-N (VI) and T-coli (la) were in the same grade, but COD, SS, T-P and F-coli were less than that of control, respectively increased or decreased by material were analyzed. 2. In the experiment of fish toxicity, Barrier sheet was found to have 66.7% of fish mortality, indicating strong fish toxicity. Synthetic rubber system root barrier sheet (20.0%) was analyzed to have medium fish toxicity, while Synthetic resin system root barrier-waterproof sheet (3.3%), Synthetic rubber system membrane root barrier sheet (3.3%) and Synthetic resin system root barrier sheet (0.0%) showed relatively lower mortality and fish toxicity. To sum up such results as found in the experiment mentioned so far, the values of harmfulness and root penetration resistance analyzed were different in each lab tank, but there was absolutely little correlation with the mortality gained from the experiment on fish toxicity. In the experiment of fish toxicity, environment-friendly root barrier materials were analyzed, and it was found that Synthetic resin system root barrier sheet, Synthetic resin system root barrier waterproof sheet and Synthetic rubber system membrane root barrier sheet are highly environment-friendly. In contrast, Synthetic rubber system root barrier sheet was found to have medium-level environment-friendliness. Also, Barrier sheet was analyzed to have low environment-friendliness.

EFFECT OF DENTINAL TUBULES ORIENTATION ON PENETRATION PATTERN OF DENTIN ADHESIVES USING CONFOCAL LASER SCANNING MICROSCOPY (상아세관의 주행방향에 따른 상아질 접착제의 침투양상에 대한 공초점레이저주사현미경 연구)

  • Kim, Dong-Jun;Hwang, Yun-Chan;Kim, Sun-Ho;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.392-401
    • /
    • 2003
  • The purpose of this study was to evaluate the penetration pattern of dentin adhesives according to the orientation of dentinal tubules with confocal laser scanning microscopy. Specimens having perpendicular. parallel and oblique surface to dentinal tubules were fabricated. The primer of dentin adhesives (ALL $BOND^{\circledR}{\;}2,{\;}CLEARFIL^{TM}$ SE BOND and PQ1) was mixed with fluorescent material. rhodamine B isothio-cyanate (Aldrich Cherm. CO., Milw., USA), It was applied to the specimens according to the instructions of manufactures. The specimens were covered with composite resin (Estelite, shade A2) and then cut to a thickness of 500$\mu\textrm{m}$ with low speed saw (Isomet^{TM}, Buehler. USA). The adhesive pattern of dentin adhesives were observed by fluorescence image using confocal laser scanning microscopy. The results were as follows. 1. For the groups with tubules perpendicular to bonded surface. funnel shape of resin tag was observed in all specimen. However. resin tags were more prominent in phosphoric acid etching system (ALL $BOND^{\circledR}$ 2 and PQ1) than self etching system ($CLEARFIL^{TM}$ SE BOND). 2. For the groups with tubules parallel to bonded surface. rhodamine-labeled primer penetrated into peritubular dentin parallel to the orientation of dentinal tubules. But rhodamine-labeled primer of PQ1 diffused more radially into surrounding intertubular dentin than other dentin adhesive systems. 3. For the groups with tubules oblique to bonded surface. resin tags appeared irregular and discontinuous. But they penetrated deeper into dentinal tubules than other groups.

Environment-friendly Adhesives for Fancy Veneer Bonding of Engineered Flooring to Reduce Formaldehyde and TVOC Emissions

  • Kim, Sumin;Kim, Hyun-Joong;Xu, Guang Zhu;Eom, Young Geun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.58-66
    • /
    • 2007
  • The objective of this research was to develop environment-friendly adhesives for face fancy veneer bonding of engineered flooring. Urea-formaldehyde (UF)-tannin and melamine-formaldehyde (MF)/PVAc hybrid resin were used to replace UF resin in the formaldehyde-based resin system in order to reduce formaldehyde and volatile organic compound (VOC) emissions from the adhesives used between plywoods and fancy veneers. Wattle tannin powder (5 wt%) was added to UF resin and PVAc (30 wt%) to MF resin. These adhesive systems showed better bonding than commercial UF resin with a similar level of wood penetration. The initial adhesion strength was sufficient to be maintained within the optimum initial tack range. The standard formaldehyde emission test (desiccator method) and VOC analyzer were used to determine the formaldehyde and VOC emissions from engineered flooring bonded with commercial UF resin, UF-tannin and MF/PVAc hybrid resin. By desiccator method, the formaldehyde emission level of UF resin showed the highest but was reduced by replacing with UF-tannin and MF/PVAc hybrid resin. MF/PVAc hybrid satisfied the $E_1$ grade (below $1.5mg/{\ell}$). VOC emission results by VOC analyzer were similar with the formaldehyde emission results. TVOC emission was in the following order: UF > UF-tannin > MF/PVAc hybrid resin.