• 제목/요약/키워드: resin penetration

검색결과 163건 처리시간 0.021초

수종(數種) 수복물(修復物)의 색소침투(色素浸透)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON PENETRATION OF DYE IN FILLING MATERIALS)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제4권1호
    • /
    • pp.29-34
    • /
    • 1978
  • The purpose of this study was to measure penetration of dye stuff(5% Methylene blue, Hematoxylin, Crystal violet and Safranin-O) on silicate cement, Adaptic, Hi-pol and unfilled resin. Each filling material was mixed on the mixing pad and the mixed material was inserted with condensation force of 500gr, 1000gr and 2000gr and without condensation force into preformed glass tube (10mm in diameter and 10mm in height). The specimen was stored in the air for 24 hours, then specimen was immersed in various dye solution (5% methylene blue, hematoxin, crystal violet and safranin-O) for different period of time (l hour and 24 hours). These dye-treated specimen was cut horizontally at the middle portion and the dye penetration in cut surface was measured. Following results were obtained. 1. Pentration of various dye was excessive in silicate cement with and without Condensation force. 2. There has been no evidence of dye penetration in unfilled resin. 3. Dye penetration occurced with in 1 hour period and the extending time didn't affect the dye penetration.

  • PDF

유치의 레진침투법을 위한 레이저 형광법의 진단적 활용 (Diagnostic Utilization of Laser Fluorescence for Resin Infiltration in Primary Teeth)

  • 박소영;정태성;김지연;김신
    • 대한소아치과학회지
    • /
    • 제46권3호
    • /
    • pp.265-273
    • /
    • 2019
  • 이 연구는 레진침투법(resin infiltration, RI)을 적용하기 적합한 초기 유아기 우식증 병소를 동정하는데 있어 레이저 형광법(laser fluorescence, LF)의 활용 가능성을 평가하기 위해 수행되었다. 인접면 우식을 가진 20개의 자연 탈락 유구치를 이용, 중심와를 지나도록 협설로 절단하여 근원심 치면을 별개의 시편으로 간주하였다. ICDAS code 1과 2에 해당하는 시편 27개를 선별하였고 LF값을 측정하였다. 현미경 평가를 위해 RI 시행 시 이중 염색을 병행하였고, 절편을 제작하였다. 현미경 영상으로부터 병소깊이(최대 탈회깊이, $LD_{max}$), 최대 침투깊이($PD_{max}$), 평균 레진 침투율(Penetration rate, PR)을 측정하고, 상관분석을 시행하였다. LF값은 PR과 양의 상관관계를 보였으나 $LD_{max}$$PD_{max}$와는 유의성을 보이지 않았다. 얕은 법랑질 우식군을 제외하고, 깊은 법랑질 우식군과 상아질 우식군에서는 LF값과 PR 간에 유의한 상관관계가 확인되었다. 활동성 우식은 RI를 적용할 경우 침투율이 높고, LF 값이 보다 높게 측정될 수 있다. 진행 정도가 유사한 우식병소의 활성도를 평가하고자 할 경우, 레이저 형광법이 유용할 것으로 사료되었다.

Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구 (GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER)

  • 박태일;신동훈;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

교합면 우식열구에서 열구성형술 방법에 따른 유동성 레진의 침투도와 미세누출 평가 (Penetration and Microleakage Assessment of Flowable Resin Applied on Carious Fissure Following Various Fissurotomy Techniques)

  • 권세옥;이상호;이난영;지명관;윤영미
    • 대한소아치과학회지
    • /
    • 제45권1호
    • /
    • pp.90-97
    • /
    • 2018
  • 본 연구의 목적은 교합면 우식열구에서 열구성형술이 유동성 레진의 침투와 미세누출에 미치는 영향을 평가하는데 있다. 교합면 우식증이 있는 발거된 소구치 250개를 대상으로 열구 성형술을 시행하지 않는 군을 대조군(n = 50), 열구성형술을 시행한 군을 실험군으로 하였으며, 실험군은 $Fissurotomy^{(R)}$ original bur (n = 50), $Fissurotomy^{(R)}$ Miro NTF bur (n = 50), SF104R tapered diamond bur (n = 50), 1/2 round carbide bur (n = 50) 등 4가지 유형의 bur를 이용하여 열구성형술을 시행한 후 2가지 종류의 유동성 레진($UniFil^{(R)}Flow$, $Filtek^{(R)}Flow$)을 적용하고 침투도와 미세누출의 평가를 통하여 전색효과를 비교하였다. 열구성형술을 시행한 군이 시행하지 않은 대조군에 비해 침투도가 컸으며 미세누출은 적었다. 1/2 round bur를 사용하여 열구성형술을 시행한 군이 다른 bur를 사용한 군에 비해 유동성 레진의 열구내로의 침투도는 높았으나 미세누출은 차이가 없었다. 유동성 레진의 종류($Unifil^{(R)}Flow$$Filtek^{(R)}Flow$)에 따른 침투도의 차이는 있었으나 미세누출은 차이가 없었다.

수종 상아질 접착제의 제 V급 와동에서의 미세 변연누출에 관한 비교연구 (AN EXPERIMENTAL STUDY FOR THE EFFECT OF ALL-BOND 2, GLUMA, SCOTCH BOND MULTI-PURPOSE)

  • 강창성;박성호;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.261-274
    • /
    • 1995
  • This study aimed to evaluate the marginal microleakage of Class V cavities of All-bond 2 (Wet - bonding system), Gluma (Adhesion of resin to exposed collagen fibers), and Scotchbond Multi-purpose(Mild Etching System). Hundred extracted human teeth divided into a control and three experimental groups consisting of eight teeth. The experimental group was further subdivided into All- bond2, Gluma and Scotchbond MP groups, Vitrebond served as the control. The positive control group consisted of specimens filled with resin and with no etching, primer and bonding procesure. Polished specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ a thousand times. After thermocycling, speciemens were placed in 2 % methylene blue dye solution for 24 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a stereomicroscoped(*20). The following results were obtained. 1. Both the control and the experimental group showed a lower degree of dye penetration on enamel than on dentin margins(p<0.05) 2. Gluma exhibited a statistically significant lower degree of dye penetration than All-bond 2 on enamel margins(p<0.05) Scotchbond MP also exhibited a lower degree of dye penetration than All-bone 2 but was no statistically significant. Gluma and Scotchbond MP exhibited a similar degree of dye penetration. 3. The degree of dye penetration of All-bond 2, Gluma and Scotch bond MP showed no statistically singnificance on enamel margins but was significantly lower than in the control using Vitrebond. 4. All-bond 2 exhibited a statistically significant lower degree of dye penetration than Gluma on dentin margins. All- bond 2 and Scotchbond MP showed a similar degree of dye penetration. 5. The degree of dye penetration of All-bond 2, Gluma and Scotchbond MP showed no statistically significance on dentin margins. There was neither a statistical significance with the control.

  • PDF

Push-out bond strength and dentinal tubule penetration of different root canal sealers used with coated core materials

  • Sungur, Derya Deniz;Purali, Nuhan;Cosgun, Erdal;Calt, Semra
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.114-120
    • /
    • 2016
  • Objectives: The aim of this study was to compare the push-out bond strength and dentinal tubule penetration of root canal sealers used with coated core materials and conventional gutta-percha. Materials and Methods: A total of 72 single-rooted human mandibular incisors were instrumented with NiTi rotary files with irrigation of 2.5% NaOCl. The smear layer was removed with 17% ethylenediaminetetraacetic acid (EDTA). Specimens were assigned into four groups according to the obturation system: Group 1, EndoRez (Ultradent Product Inc.); Group 2, Activ GP (Brasseler); Group 3, SmartSeal (DFRP Ltd. Villa Farm); Group 4, AH 26 (Dentsply de Trey)/gutta-percha (GP). For push-out bond strength measurement, two horizontal slices were obtained from each specimen (n = 20). To compare dentinal tubule penetration, remaining 32 roots assigned to 4 groups as above were obturated with 0.1% Rhodamine B labeled sealers. One horizontal slice was obtained from the middle third of each specimen (n = 8) and scanned under confocal laser scanning electron microscope. Tubule penetration area, depth, and percentage were measured. Kruskall-Wallis test was used for statistical analysis. Results: EndoRez showed significantly lower push-out bond strength than the others (p < 0.05). No significant difference was found amongst the groups in terms of percentage of sealer penetration. SmartSeal showed the least penetration than the others (p < 0.05). Conclusions: The bond strength and sealer penetration of resin-and glass ionomer-based sealers used with coated core was not superior to resin-based sealer used with conventional GP. Dentinal tubule penetration has limited effect on bond strength. The use of conventional GP with sealer seems to be sufficient in terms of push-out bond strength.

공초점레이저주사현미경을 이용한 심미수복재와 상아질의 접착계면에 관한 연구 (A CONFOCAL LASER SCANNING MICROSCOPIC STUDY ON THE INTERFACE BETWEEN TOOTH COLORED RESTORATIVE MATERIALS AND DENTIN)

  • 박병철;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.313-320
    • /
    • 2000
  • The purpose of this study was to evaluate on the interfacial morphology between dentin and restorative materials. In this in vitro study, the cavity wall restorated with 3 different kinds of tooth colored restorative materials [resin-modified Glass Ionomer cement (Fuji II LC), composite resin (Z-100), compomer (Dyract)]. The thirty extracted human molar teeth without caries and/or restorations are used. The experimental teeth were randomly divided into three groups of ten teeth each. In each group, Wedge shaped cavities (width: 3mm, length: 2mm, depth: 1.5mm) were prepared at the cementoenamel junction on buccal and lingual surfaces. The adhesive of composite resin were mixed with rhodamine B. Primer of composite resin, Prime & Bond 2.1 of Dyract and liquid of Fuji II LC were mixed with fluorescein. In group 1, the cavity wall was treatment with dentin conditioner, and then restorated with Fuji II LC. In group 2, the cavity wall was treatment with Prime & Bond 2.1 and then restorated with Dyract. In group 3, the cavity wall was etching with 10% maleic acid, applied with primer and bonding agent and then restorated with Z-100. The interface between dentin and restorative materials was observed by fluoresence imaging with a confocal laser scanning microscope. The results were as follows : 1. In Glass ionomer group, adaptation of resin modified Glass-ionomer restoration against cavity wall is tight, but the crack formed inside of restoration were observed. 2. In Dyract group, the penetration of resin tag is shorter and the width of hybrid layer is narrower than composite resin group. 3. In Z-100 group, primer penetrated deeply through dentinal tubule. Also bonding agent was penetrated along the primer, but the penetration length is shorter than primer part, and in 3-D image, the resin tag is conical shape and lateral branch is observed.

  • PDF

유구치 아말감 수복물에서 레진 접착성 이장재의 미세 변연 누출에 관한 비교 연구 (AN EXPERIMENTAL STUDY FOR MICROLEAKAGE OF AMALGAM USING RESIN ADHESIVE LINERS IN PRIMARY MOLAR TOOTH)

  • 김종태;최병재;이제호;이종갑
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.401-414
    • /
    • 1996
  • The purpose of this study was to compare the marginal leakage of resin liner which was used as a liner to amalgam restoration. Control group composed of no liner group, copalite group and experimental group composed of All-bond 2, Vitrebond, Superbond D-liner applied groups were evaluated. Cl.V preparation with a size of $3{\times}2{\times}1.5mm$ on 70 extracted primary molars were made and applied appropriate liners for each groups. After amalgam filling and polishing, polished specimens underwent temperature changed from $5^{\circ}C\;to\;55^{\circ}C$ a thousand times. After thermocycling, specimens were placed in 2% methylene blue dye solution for 72 hours in an incubator set at $37^{\circ}C$. The teeth were sectioned buccolingually and the degree of dye penetration was observed with a spectroscopy. (${\times}30$) The following results were obtained. 1. Vitrebond, All-bond 2, Superbond D-liner group exhibited a statistically significant lower degree of dye penetration than no liner and copalite group. (Kruskal-Wallis analysis, P<0.05) 2. No liner group and copalite group exhibited a similar degree of dye penetration. (Mann-Whitney analysis, P>0.05) 3. All-bond 2 group exhibited a statistically significant lower degree of dye penetration than Vitrebond group, (Mann-Whitney analysis, P<0.05) Superbond D-liner group also exhibited a lower degree of dye penetration than Vitrebond group but was statistically insignificant. (Mann-Whitney analysis, P>0.05)

  • PDF

수종충전재의 변연누출에 관한 실험적 연구 (A Study of Marginal Leakage on Various Filling Materials)

  • 이윤상;김홍석;박가명
    • 대한치과의사협회지
    • /
    • 제11권5호
    • /
    • pp.337-340
    • /
    • 1973
  • The authers have studied the marginal leakage on various filing materials : Composite resin, Polycarboxylate cement, Zinc phosphate cement, Silicate cement and Zinc-oxide eugenol cement, by means of penetration of 2% aquous methylene blue between cavity walls and filing materials at body temperature and at thermal changs in the range of 4~60℃ The results revealed as follows. 1) All the filling materials revealed the penetration of dye between cavity walls and filling materials. 2) Zinc-oxide eugenol cement was the most effective to prevent the dye penetration on the contrary silicate cement cases showed greatest leakage at 37℃ and at temperature changes in range of 4-60℃. 3) The composite resin showed moderate leakage either at 37℃ or at thermal changes 4) Marginal obstructions of polycarboxylate cement were unsatisfactory at 37℃ and at temperature changes.

  • PDF

제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가 (A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES)

  • 김형수;박성호
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.