• 제목/요약/키워드: resin canal

검색결과 187건 처리시간 0.026초

촉진열화실험에 의한 소나무의 물성 및 조직 변화에 대한 연구 (Study on the Change of Physical and Anatomical Properties in the Pine Wood by Accelerated Weathering Test)

  • 김광철
    • 한국가구학회지
    • /
    • 제23권3호
    • /
    • pp.324-331
    • /
    • 2012
  • The domestic pine was used to investigate the change of specific gravity, moisture contents, color and anatomical structure by accelerated weathering test (AWT). According to visual inspection, a few knot separation and looseness as well as considerable surface discoloration was found out. However, the crack and split of surface texture have been never occurred till the last step of AWT. On the whole, as the time of accelerated weathering test has increased, the specific gravity has decreased. Finally, after the 9th week of AWT, the specific gravity was 0.38 that reached to 82% compared to the control specimen. In case of moisture content (MC), it showed rising trend in its early stages, however, after 3th week of AWT it have displayed steady state. A deterioration of cell-wall components was not remarkably observed by scanning electron microscope (SEM), however the ray fractures of AWT specimen were observed more than those of control specimen. The full fracture of epithelial cell around resin canal was observed by optical microscope. The fracture of ray of 2th cycle AWT specimen was first, followed by 1th week and control group. A distortion of tracheid for early spring wood and fracture of epithelial cell were generally observed by a similar level, regardless of duration time of AWT. Therefore, it is obvious that increasing duration time of AWT does not affect the deterioration of micro-structure for wood members from this study. Although a considerable change of anatomical properties was not found, there is a need of further research to understand how will the changes of specific gravity and MC on the physical properties of wood member.

  • PDF

시멘트의 종류에 따른 포스트의 인장강도 및 제거의 난이도에 관한 연구 (THE EFFECT OF VARIOUS CEMENTS ON THE TENSILE STRENGTH OF A POST AND DIFFICULTIES OF ULTRASONIC POST REMOVAL)

  • 박정원;노병덕;이정석
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.181-192
    • /
    • 1997
  • The difficulty of endodontic retreatment depends on various factors and it is affected by retention of post. In this experiment, root canal therapy was done in extracted human teeth and cut into 10mm length from the root apex, and then cemented by zinc phosphate cement, Vitremer$^{(R)}$(glass ionomer) luting cement and Panavia 21$^{(R)}$(resin cement). Post preparation was done by #4 Parapost drill at 6mm length and cement was inserted by lentulo spiral. After 24 hours, tensile bond strength, post removal time was measured after the ultrasonic application and the separation site was measured. The following results were obtained. 1. In measuring tensile bond strength, there is no statistical difference between zinc phosphate cement and Panavia 21$^{(R)}$, but Vitremer$^{(R)}$ showed lower value compared with those two cements. (p<0.001) 2. When the post removal time was measured after ultrasonic application, significant different value in order of Panavia 21$^{(R)}$, zinc phosphate cement and Vitremer$^{(R)}$ was shown. (p<0.001) 3. As a result of examining the separating site of each cement, all 16 of zinc phosphate cement group showed the fracture site between cement and post, Vitremer$^{(R)}$ was 13/16, and Panavia 2$^{(R)}$ was 8/16. In case of tooth restoration using Parapost, the use of Panavia 21 showed good retention property than Vitremer$^{(R)}$, but when retreatment is needed the difficulty of post removal will be increased.

  • PDF

Screw-in forces during instrumentation by various file systems

  • Ha, Jung-Hong;Kwak, Sang Won;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.304-309
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Materials and Methods: Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS-k, DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Results: Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest (p < 0.05). Conclusions: Geometrical differences rather than shaping motion and alloys may affect the screw-in force during canal instrumentation. To reduce screw-in forces, the use of NiTi files with smaller cross-sectional area for higher flexibility is recommended.

뇌병변 환아에서 외상성 손상을 받은 미성숙 영구치의 치험례 (TREATMENT OF AN IMMATURE, TRAUMATIZED PERMANENT TOOTH OF A PATIENT WITH CEREBRAL PALSY : A CASE REPORT)

  • 허선재;신터전;현홍근;김정욱;장기택;이상훈;김종철;김영재
    • 대한장애인치과학회지
    • /
    • 제12권2호
    • /
    • pp.72-76
    • /
    • 2016
  • 저자는 뇌병변 장애와 보행장애로 반복적인 외상성 치아손상을 받은 환아의 치료를 시행하였다. 최근 실활된 미성숙 영구치의 계속된 치근 형성을 위해 재생적 근관치료 술식이 많이 시도되어 성공적인 결과를 보이고 있다. 하지만 장애로 인해 반복적인 외상의 위험을 가진 환아에서 치수조직의 재생 보다는 치근단형성술을 통한 치근단의 폐쇄와 근관 충전이 비용과 장기적인 예후의 측면에서 유리한 치료방법이 될 수 있음을 확인하였다.

Observation of an extracted premolar 2.5 years after mineral trioxide aggregate apexification using micro-computed tomography

  • Lee, Gayeon;Chung, Chooryung;Kim, Sunil;Shin, Su-Jung
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.4.1-4.6
    • /
    • 2020
  • Although numerous studies have been conducted on apexification using mineral trioxide aggregate (MTA), direct observation of extracted human teeth after the procedure has been rarely reported. This case report describes a mandibular premolar treated 2.5 years ago and extracted recently for orthodontic treatment. The tubercle of the right mandibular premolar of a 12-year-old boy with dens evaginatus was fractured and the pulp was exposed. The tooth was diagnosed with pulp necrosis and asymptomatic periapical abscess. During the first visit, copious irrigation was performed with 2.5% sodium hypochlorite. Calcium hydroxide paste was placed as an intracanal medicament. The sinus tract had disappeared at the second visit after 3 weeks. MTA was applied on to the bleeding point as a 4-mm-thick layer, followed by a 3-mm-thick gutta-percha filling and resin core build-up. After 2.5 years, the tooth and three other premolars were extracted for orthodontic treatment. The right and left mandibular premolars were scanned with micro-computed tomography to determine the root shape and canal anatomy. Irregular root growth was observed and the root outline of the right mandibular premolar differed from that of the contralateral tooth. Apexification with MTA leads to the formation of roots with irregular morphology, without any pulpal space.

근관와동형태에 따른 근관치료된 하악절치의 파절강도 (THE INFLUENCE OF DIFFERENT ACCESS CAVITY DESIGNS ON THE FRACTURE STRENGTH IN ENDODONTICALLY TREATED MANDIBULAR ANTERIOR TEETH)

  • 이영균;신혜진;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.515-519
    • /
    • 2004
  • Straight access cavity design allows the operator to locate all canals, helps in proper cleaning and shaping, ultimately facilitates the obturation of the canal system. However, change in the fracture strength according to the access cavity designs was not clearly demonstrated yet. The purpose of this study was to determine the influence of different access cavity designs on the fracture strength in endodontically treated mandibular anterior teeth. Recently extracted mandibular anterior teeth that have no caries, cervical abrasion, and fracture were divided into three groups (Group 1 : conventional lingual access cavity, Group 2 : straight access cavity, Group 3 : extended straight access cavity) according to the cavity designs. After conventional endodontic treatment, cavities were filled with resin core material. Compressive loads parallel to the long axis of the teeth were applied at a crosshead speed of 2mm/min until the fracture occurred. The fracture strength analyzed with ANOV A and the Scheffe test at the 95% confidence level. The results of this study were as follows: 1. The mean fracture strength decrease in following sequence Group 1 (4558.90{\;}\pm{\;}77.40{\;}N$), Group 2 ($494.07{\;}\pm{\;}123.98{\;}N) and Group 3 ($267.33{\;}\pm{\;}27.02{\;}N). 2. There was significant difference between Group 3 and other groups (P = 0.00). Considering advantage of direct access to apical third and results of this study, straight access cavity is recommended for access cavity form of the mandibular anterior teeth.

A CAD/CAM-based strategy for concurrent endodontic and restorative treatment

  • Escobar, Patricia Maria;Kishen, Anil;Lopes, Fabiane Carneiro;Borges, Caroline Cristina;Kegler, Eugenio Gabriel;Sousa-Neto, Manoel Damiao
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.27.1-27.12
    • /
    • 2019
  • This case report describes a technique in which endodontic treatment and permanent indirect restoration were completed in the same clinical appointment with the aid of a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Two patients were diagnosed with irreversible pulpitis of the mandibular first molar. After access preparation, root canals were located, irrigation was performed until bleeding ceased, and the coronal tooth structure was prepared for indirect restoration. Then, utilizing an interim 3-mm build-up of the endodontic access cavity, a hemi-arch digital scan was performed with an intraoral scanner. Subsequent to digital scanning, restoration design was performed simultaneously with the endodontic procedure. The root canals were shaped using the Race system under irrigation with 2.5% sodium hypochlorite followed by root canal filling. The pulp chamber was subsequently filled with a 3-mm-thick composite resin restoration mimicking the interim build-up previously utilized to facilitate block milling in the CAD/CAM system. Clinical try-in of the permanent onlay restoration was followed by acid etching, application of a 5th generation adhesive, and cementation of the indirect restoration. Once the restoration was cemented, rubber dam isolation was removed, followed by occlusal adjustment and polishing. After 2 years of follow-up, the restorations were esthetically and functionally satisfactory, without complications.

Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth

  • Maria Aparecida Barbosa de Sa;Eduardo Nunes ;Alberto Nogueira da Gama Antunes ;Manoel Brito Junior ;Martinho Campolina Rebello Horta ;Rodrigo Rodrigues Amaral;Stephen Cohen ;Frank Ferreira Silveira
    • Restorative Dentistry and Endodontics
    • /
    • 제46권4호
    • /
    • pp.53.1-53.11
    • /
    • 2021
  • Objectives: This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. Materials and Methods: A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. Results: The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). Conclusions: The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.

Fiber reinforced composite post의 표면 처리에 따른 접착 강도 (Retentive bond strength of fiber-reinforced composite posts cemented with different surface treatments)

  • 노현식;노관태;우이형;배아란
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.113-120
    • /
    • 2014
  • 연구 목적: 본 연구는 근관치료된 치아에 레진 시멘트로 fiber reinforced composite post (FRC) post의 접착시 포스트의 다양한 표면처리를 비교하여, 새롭게 제안되고 있는 다용도 프라이머의 효용성에 대해 평가하고자 하였다. 연구 재료 및 방법: 근관치료된 소구치 중 치근길이 1.8 cm 이상 되는 치아만을 총 24개 선택하였다. 표면 처리하지 않은 대조군과 표면처리를 시행한 FRC posts (DT Light Post, Size3, Bisco Inc., Schaumburg, IL, US)를 다음과 같이 6개의 그룹으로 무작위 분류하였다: Group A: airborne-particle abrasion (Cojet sand, 3M ESPE), Group S: silanization (Bis-silane, Bisco Inc.), Group M: universal primer (Monobond-plus primer, Ivoclar Vivadent Inc.), Group AS: silanization after airborne-particle abrasion, Group AM: universal primer treatment after airborne-particle abrasion. 하였다. CEJ에서 1.5 cm 근관성형 후 레진 시멘트를 이용하여 표면처리된 총 24개의 FRC post를 접착하고 광중합하였다. 생리식염수에 24시간 보관한 후 포스트 장축에 수직으로 1 mm 두께로 절단하여 만능시험기로 push-out test를 시행하였다. 포스트가 탈락되는 접착 실패 강도를 측정하고 SEM을 관찰하여 접착 실패 양상을 분류하고, 접착 강도를 Kruskal-Wallis test와 Tukey HSD value of rank test를 이용하여 통계 분석하였다(${\alpha}=0.05$). 결과: Airborne-particle abrasion후 실란 처리한 실험군에서 유의할만하게 높은 접착 강도를 보였다. 실란 처리, airborne-particle abrasion후 다용도 프라이머를 처리한 실험군의 순서로 접착 강도가 높게 나타났다. FRC post의 표면에 특정 전처리를 하지 않은 대조군에서 가장 낮은 결합 강도를 보이고, 이어서 다용도 프라이머, airborne-particle abrasion 순으로 낮은 평균 접착 강도를 보였다. 결론: FRC post의 접착 전 표면 처리 과정으로서 실란 처리를 거친 실험군에서 높은 결합 강도를 보였으며, 다용도 프라이머를 이용한 표면 처리는 실란과 비교하여 유의성 있는 접착 강도의 변화를 보이지 않았다.

반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석 (EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS)

  • 황수연;오소람;이윤;임상민;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.424-429
    • /
    • 2009
  • 본 연구의 목적은 니켈 티타늄 전동파일의 피로 파절에 파일의 단면 형태가 미치는 영향을 평가하고자 하였다. 6 종의 ProFile (Dentsply), Mtwo (VDW), K3 (SybronEndo), Heroshaper (MicroMega), NRT (Mani), Alpha system (KOMET) 니켈-티타늄 전동 파일(ISO 30 size/.04 taper)을 각 10개씩 실험군으로 배정하고 실험을 진행하였다. 니켈 티타늄 전동파일에 반복적인 장력과 압축력을 재현시킬 수 있는 피로파절 실험기(Denbotix)와 연결된 토크 조절 전동모터(Aseptico)에 각 군의 파일을 연결하여 300rpm 속도로 만곡도가 60도이고 5mm의 반경을 가진 인공 금속 근관 내를 6 mm pecking depth로 작동시켰다. 각 파일의 파절시간을 측정하고 통계 분석하여 유의성을 분석하였으며, 각 군의 파절된 모든 파일의 파절면을 주사전자현미경을 이용한 fractographic analysis를 통해 파절 역학을 규명하였다. 또한 각 군에서 3개의 사용하지 않은 새 파일을 clear resin에 매몰하고tip에서부터 3mm 지점을 횡절단하여 Image-Pro Plus (Imagej 1.34n, NIH) 소프트웨어로 절단면의 단면적을 측정하고 단면적의 크기와 피로 파절과의 상관성도 평가하였다. 실험 결과 NRT와 ProFile이 다른 실험군에 비해서 유의성 있게 높은 피로 파절 저항성을 보였다(P < .05). 또한 파일의 단면적은 피로파절 저항성과 통계학적인 유의성은 보이지 않았다. Fractographic analysis 결과 모든 시편에서 파절면은 ductile fracture와 brittle fracture가 혼재된 양상으로 나타났다. 결론적으로 니켈 티타늄 전동 파일의 단면적의 크기는 피로파절 저항과는 상관성이 적었다.