Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.

측방가압충전시 Heated Spreader 사용유무가 근관밀폐에 미치는 영향 (INFLUENCE OF HEATED SPREADER ON THE SEALING ABILITY OF LATERAL CONDENSATION)

  • 정원균;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제24권1호
    • /
    • pp.222-232
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of heated spreader on the sealing ability of lateral condensation, compared with regular cold spreader. Forty two extracted human teeth with single canal were randomly placed into 3 experimental groups, and four additional teeth were used as positive and negative controls. Each group was prepared with Ni-Ti Profile #40 using step-down technique and obturated with standardized colored gutta-percha cone by standard(cold) lateral condensation technique, warm lateral condensation technique with Endotec and hot spreader soaked in glass bead sterilizer, each with Sealapex sealer. Control groups were not obturated, but prepared. After 2 days in 2% methylene blue, the teeth were invested and made into transparent resin blocks. And then, each block was sectioned horizontally with microtome at 1, 2, 3, 4, 5 mm levels from the apex. The linear extent of dye penetration was examined with stereomicroscope at ${\times}$20 magnification. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using an analysis of variance(ANOVA) and Scheffe test. The results were as follows ; 1. All experimental groups produced the apical microleakage. 2. The mean leakage was 1.57${\pm}$0.76mm for cold spreader group, 0.86${\pm}$0.95mm for Endotec spreader group, and 0.64${\pm}$0.93mm for hot spreader group. The difference between hot spreader group and cold spreader group was statistically significant(p<0.05). 1. At the 1 mm level, the mean ratio of area of gutta-percha was 74.58${\pm}$13.15(%) for cold spreader group, 65.42${\pm}$14.62(%) for Endotec spreader group, and 80.72${\pm}$14.63(%) for hot spreader group. There was statistically significant difference between hot spreader group and Endotec spreader group(p<0.05). 2. At the 2mm level, the mean ratio of area of gutta-percha was 87.86${\pm}$11.22(%) for cold spreader group, 66.55${\pm}$14.02(%) for Endotec spreader group, and 92.93${\pm}$7.24(%) for hot spreader group. There was statistically significant difference between Endotec spreader group and other two spreader groups(p<0.05). 3. At the level 3, 4, 5 mm, there was no statistically significant difference between each group. Within the limits of the results of this experiment, warm lateral condensation technique with hot spreader soaked in a glass bead sterilizer demonstrated favorable apical sealing effect and improved density of gutta-percha mass. Thus, it is thought that this obturation technique is effective for clinical use and beneficial to reduce condensation forces, also economical and easy. Lateral condensation, Heated spreader, canal sealing, Microleakage.

  • PDF

학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교 (COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES)

  • 강문성;김현철;허복;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.1-10
    • /
    • 2006
  • 본 연구의 목적은 학생들이 사용한 세 가지 Ni-Ti파일의 성형효율을 비교하고, 각 파일의 사용 경험 유무에 따른 차이를 비교하여 치과대학생을 위한 교육에 적합한 종류를 선택하는데 도움을 얻고자하는 것이다. Ni-Ti파일 사용 경험이 없는 학생 50명과 Ni-Ti파일을 사용한 근관치료 경력이 2년 이상인 경험자 10명이 세 종류의 Ni-Ti file - $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$ -을 사용하여 180개의 근관 모형을 성형하였다. 근관성형 시간 및 기구 변형, 근관 이형성을 조사하고 성형 전후 상을 중첩하여 근관 삭제폭, 근관변위량과 중심변위율을 1, 3. 5 mm에서 분석하였다. 1. 근관 성형시간은 HS군이 가장 빨랐으며, 총 삭제 량은 모든 지점에서 K3군이 다른 군보다 컸다 (P<0.05) . 2. 세 군 모두 1, 3 mm에서 외측 변이를 보였고, 1 mm지점에서 PF군이 가장 안정적이었다 (P<0.05). 3. 중심변위율은 1, 3 mm에서 HS, PF군이 K3군보다 작았다. 5 mm지점에서는 PF군이 가장 작았고, PF군 3 mm에서 학생은 경험자보다 유의하게 작았다 (P<0.05).

엔진의 토크 조절 능력과 니켈-티타늄 파일의 삭제 성향이 근관 성형에 미치는 영향 (THE EFFECT OF DIFFERENT FLUTE DESIGN AND TORQUE-CONTROLLED MOTOR ON THE SHAPING ABILITY OF SIMULATED RESIN ROOT CANALS)

  • 노형미;허복;김현철;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제30권6호
    • /
    • pp.486-492
    • /
    • 2005
  • 이 연구의 목적은 니켈-니타늄 파일의 삭제 성향과 엔진의 토크 조절 능력이 근관 성형에 미치는 영향을 평가하는 것이다 레진 모형 40개를 사용하였으며, Hero Shaper(R)와 Endo-Mate2을 이용한 HE군, Hero Shaper(R)와 Tecnika(R)를 이용한 HT군, Profile(R)과 Endo-Mate2(R)를 이용한 PE군, Profile(R)과 Tecnika(R)를 이용한 PT군으로 구분하여 근관성형 하였다. 각 군별 근관 성형 시간을 기록하였다. 근단공으로부터의 수직 이동 거리 1, 3 그리고 5mm 위치에서의 근관 삭제량, 중심이 동률을 산출하여 다음의 결론을 얻었다. 1. 근관 성형 시간은 HT군이 가장 빨랐다 (p<0.05). 2. 삭제량은 1mm지점에서 HE군이 PT군보다 컸고 (p<0.05), 3mm지점에서는 PT군이 다른 군들보다 작았다 (p<0.05). 5mm에서는 PE군이 PT군보다 컸다 (p<0.05). 3. 중심 이동률은 1mm 지점에서 HE군이 다른 군들보다 컸으며 (p<0.05), 5mm에서는 HT군이 PE군과 PT군보다 컸다 (p<0.05). 따라서 토크 조절이 되는 엔진을 사용하는 것이 근관의 변위를 적게 유발하고 과도한 삭제 량을 예방 할 수 있으며 근관 성형시간도 단축 할 수 있는 것으로 보이며 따라서 양호한 근관 성형 결과에 영향을 준다고 볼 수 있다.

Detection of laser doppler blood flow signal from human teeth

  • Ikawa, M.;Iiyama, M.;Shimauchi, H.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.546.1-546
    • /
    • 2003
  • Laser doppler flowmeter (LDF) has been applied to the measurement of pulpal blood flow (PBF) in human teeth. As far as we searched, the detection area of the pulp in the blood flow measurement has not been clarified, yet. Therefore, the purpose of this study was to obtain information of the detection area in PBF measurement using LDF. The experiments were performed on the artificial blood circulation in extracted human upper central incisors. The apical portions of examined teeth (n=6) were severed and root canals were enlarged from the apical end to the 2mm incisal to the level of enamel-cement junction. An individual resin cap of each tooth was prepared and a hole was drilled 2mm incisal to enamel-cement junction of the labial side of the cap. The measurement probe of LDF (MBF3D, Moor Instrument, UK) was plugged into the hole of the cap. Heparinized human peripheral blood, which was in advance collected and diluted 3 times with physiological saline, was pumped through the apical foramen of the teeth via a silicone tube and a disposable needle (o.d. 0.7mm) and blood flow signals were monitored. The flux signal significantly increased with the enlargement of the root canal to incisal direction (p<0.01, Friedman analysis). The result indicates that the performance of LDF in PBF with human teeth is limited.

  • PDF

학생들이 사용한 세 종류 Ni-Ti file systems의 근관성형 효율 비교 (Relative efficacy of three Ni-Ti file systems used by undergraduates)

  • 김현철;박정길;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제30권1호
    • /
    • pp.38-48
    • /
    • 2005
  • 이 연구의 목적은 Ni-Ti file을 사용한 경험이 없는 학생들이 세 종류 Ni-Ti file systems을 사용하였을 때 근관 형성 효율을 비교하는 것이다. Ni-Ti file의 사용 경험이 없는 부산대학교 치과대학 4학년 학생 50명이 세 종류의 Ni-Ti file system - $ProFile^{(R)}$ (PF : Dentsply Maillefer, Ballaigues, Switzerland), manual $ProTaper^{(R)}$ (MPT: Dentsply Maillefer, Ballaigues, Switzerland), rotary $ProTaper^{(R)}$ (RPT: Dentsply Maillefer, Ballaigues, Switzerland) -을 사용하여 각 system으로 하나의 근관씩, 모두 150개의 레진 블락 근관모형(Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland)을 형성하였다. 근관형성에 사용된 file의 파절이나 변형 및 근관형성 후 형태의 이상을 조사하고, 스캐너로 근관 형성 전후의 이미지를 채득하여 중첩 비교함으로써 근단부로부터 1mm, 3mm, 그리고 5mm 높이에서의 삭제된 근관의 폭경, 근관의 변위량, 그리고 중심변위율 등을 산출하고 통계학적 비교 분석을 하였다. 그리고 세 가지 systems에 관한 학생들의 주관적인 선호도를 조사하였다. 그 결과 졸업을 앞둔 치과대학 재학생들도 특별한 문제점 없이 세 가지 Ni-Ti file systems을 사용한 근관형성이 가능함을 확인하였다. 세 실험군을 비교하였을 때, 양적인 삭제 능력은 두 $ProTaper^{(R)}$ systems (manual and rotary)이 $ProFile^{(R)}$에 비해 우세하였지만, 근관의 변위는 두 $ProTaper^{(R)}$ systems에서 더 많이 유발되었다. 근관 중심 이동률 등의 질적 평가를 포함하여 학생들의 선호도를 종합적으로 고려할 때, 삭제 능력에 있어서는 rotary $ProTaper^{(R)}$가 더 효율적이지만 안전성을 고려하면 $ProFile^{(R)}$도 추천된다. 정규 교육과정에서 Ni-Ti file systems의 도입을 위해서 초심자와 관련한 더 많은 연구가 진행되어야 하겠다.

임플랜트 전산화단층사진에서 하악의 위치와 gantry각의 변화가 임플랜트 매식로 평가에 미치는 영향에 관한 연구 (The effect of mandibular position and gantry angle on the evaluation of implant site with implant CT)

  • 이설미;안창현;최항문;허민석;이삼선;최순철;박태원
    • Imaging Science in Dentistry
    • /
    • 제32권1호
    • /
    • pp.35-39
    • /
    • 2002
  • Purpose: The altered gantry angle during scanning for some multiplanar reconstruction CT program (CT/MPR) may cause distortion of the image. The aim of this study was to ascertain whether there is a image distortion in a reformatted image when the gantry and the object are equally inclined using ToothPix and DentaScan program. Materials and Methods: A resin block model with four cylindrical holes and a human dry mandible were used. Two MPR software packages, ToothPix and DentaScan program, were used for reformatted panoramic images. The block and the gantry were equally inclined at 0°, 15°, and 30°. Results: With ToothPix program, a resin block model with empty holes and a dry mandible showed inclined images in the reformatted panoramic image. Increasing the gantry angle, the depth and inclination of the holes were increased in the reformatted central panoramic images. However, a resin block model with gutta perch a in its holes and a dry mandible with a wire in its mandibular canal didn't show image distortion. With DentaScan program, image distortion was not seen in any situation. Conclusion: ToothPix program may distort the reformatted image when the gantry angle is not at zero degrees. However, with DentaScan program, the patient may be positioned comfortably and the gantry can be adjusted to the patient positioning.

  • PDF

쐐기형 5급 와동과 근관와동을 복합레진으로 수복한 상악 소구치에 대한 응력 분석: 3차원 유한요소법적 연구 (STRESS ANALYSIS OF MAXILLARY PREMOLARS WITH COMPOSITE RESIN RESTORATION OF NOTCH-SHAPED CLASSⅤCAVITY AND ACCESS CAVITY ; THREE-DIMENSIONAL FINITE ELEMENT STUDY)

  • 이선화;김현철;허복;김광훈;손권;박정길
    • Restorative Dentistry and Endodontics
    • /
    • 제33권6호
    • /
    • pp.570-579
    • /
    • 2008
  • 이 연구의 목적은 쐐기형 5급 와동과 근관와동을 복합레진으로 수복한 상악 제2소구치에 대한 응력 분포를 3차원 유한요소법으로 분석하여 평가하기 위한 것이다. 발치된 상악 제2소구치를 이용하여 Micro-CT로 스캔한 후 3D-DOCTOR로 3차원 유한요소 모형을 제작하였다. 제작된 소구치 모형에 근관 와동을 형성하고 쐐기형 5급 와동과 글래스 아이오노머 기저재의 사용 여부를 구분하여 근관 와동을 혼합형 복합레진으로 충전하였다. 협측 교두 또는 설측 교두에 500 N의 하중을 가하고, ANSYS 8.0 프로그램으로 인장 응력의 분포를 분석하여 평가한 결과 베이스 사용유무에 따른 응력 분포의 차이는 없었다. 협측 교두에 하중이 가해질 때, 하중점과 교합면의 중심구, 구개측 백악법랑경계부에 과도한 인장 응력이 집중되었으며, 5급 와동이 없는 경우보다 5급 와동이 있는 경우에 약간 더 높았다. 설측 교두의 협측 경사면에 하중이 가해질 때, 하중점과 교합면의 중심구, 협측 치경부에 과도한 인장 응력이 집중되었으며, 5급 와동이 있는 경우가 5급 와동이 없는 경우보다 약간 더 낮았다.

지리산(智異山) 잣나무집단(集團)의 변이(變異)에 관(關)한 연구(硏究) (The Variation of Population of Pinus koraiensis Sieb. et Zucc. in Mt. Jiri)

  • 이강영
    • 한국산림과학회지
    • /
    • 제34권1호
    • /
    • pp.1-14
    • /
    • 1977
  • 지리산(智異山) 일대(一帶)에 생육(生育)되고 있는 잣나무집단(集團)의 변이(變異)를 구명(究明)하기 위해 수형(樹形), 침엽(針葉), 자엽(子葉), 종자(種子), 묘목성장(苗木成長)의 특성(特性)을 조사하였다. 두개 집단(集團)을 비교(比較) 검토(檢討)하였던 바 그 결과(結果)를 요약(要約)하면 다음과 같다. 1. 침엽(針葉)의 엽장(葉長), 거치밀도(鋸齒密度), 종자충실율(種子充實率), 종자장(種子長), 종자후(種子厚), 자엽장(子葉長), 자엽폭(子葉幅), 자엽(子葉)의 기공선수(氣孔線數)와 묘고성장(苗高成長)에 있어서는 집단(集團), 개체간(個體間)에 유의차(有意差)를 인정(認定)할 수 있었다. 2. 수목(樹木)의 역지각(力枝角)과 목재(木材)의 비중(比重), 자엽(子葉)의 수지구수(樹脂溝數)의 형질(形質)에 있어서는 집단간(集團間)에 유의차(有意差)가 인정(認定)되었다. 3. 침엽(針葉)의 기공선수(氣孔線數), 종자폭(種子幅), 종자중량(種子重量), 자엽(子葉)의 거치밀도(鋸齒密度), 자엽수(子葉數)의 형질(形質)은 개체간(個體間)에 유의차(有意差)를 인정(認定)할 수 있었다. 4. 침엽(針葉)의 수지구(樹脂溝)는 집단(集團), 개체간(個體間) 모두 3개(個)의 주수지구(主樹脂溝)만 발달(發達)하여 변이폭(變異幅)은 인정(認定)할 수 없었다. 그리고 수간형(樹幹型)은 두 집단(集團) 모두 통직성(通直性)을 나타내었다. 5. 침엽(針葉)과 자엽(子葉) 형질(形質)의 변이계수(變異係數)는 대체로 자엽(子葉)의 것이 큰 경향(傾向)을 나타내었다.

  • PDF

레진 계통의 근관 충전재의 제거 용이성에 대한 평가 (Evaluation of retrievability using a new soft resin based root canal filling material)

  • 신수정;이윤;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제31권4호
    • /
    • pp.323-329
    • /
    • 2006
  • 본 실험의 목적은 새로운 레진계통의 근관 충전재로 개발된 Resilon (Epiphany, 미국 Pentron사)의 재 치료 시 제거의 용이성을 평가하는 것 이었다. 27개의 발거된 단근치를 사용하였으며, 치관부를 삭제하여 치근의 길이가 12 mm가 되도록 조정하였다. Crown-down 방법에 따라 ProFile system을 이용하여 3%의 차아염소산 나트륨 용액과 17% EDTA 용액으로 세척하면서 ISO 크기 35번, 0.04 taper ProFile이 근관장에 도달할 때까지 근관 형성을 시행하였다. 제 1군 (n = 12)은 가타퍼챠와 AH26 플러스 실러를 사용하여 열가소성 가압 충전법으로 충전 하였으며, 제 2군 (n = 15)은 같은 방법으로 제조사의 지시에 따라 Resilon으로 충전하였다. 충전 후 표본은 밀폐를 하여 습도 100%, 섭씨 37도가 유지되는 곳에 일주일간 보관하였다. 재 치료를 위하여 Gates Glidden bur와 ProFile system을 이용하여 근관 충전 물질을 제거 하였으며 이전 근관 형성 보다 한 단계 더 큰 크기의 ProFile이 근관장에 도달하는 시점까지의 시간을 기록 하였다. 최종 세척은 3% NaOCl, 17% EDTA 그리고 증류수가 사용되었다. 그 후 치아는 수직 절단하여 주사전자 현미경하에 근관의 전반적인 청결도 및 충전 물질의 잔존 정도를 치근단, 중간, 치관부로 나누어서 75배 확대상으로 평가하였다. 근관 충전 물질을 제거하는 데에 걸린 시간은 분 단위로 기록되어서 실험군 간의 차이는 Student-t 검정을 사용하여 그 유의성을 검증하였다 (오차범위 0.05 미만). 주사전자 현미경 사진은 두 명의 관찰자가 5단계로 평가하였으며 Chi-square 검정을 통해서 통계학적 유의성을 검증하였다 (오차범위 0.05 미만). 충전 후 충전재의 제거에 걸린 시간은 제 1군이 $3.25\;{\pm}\;0.32$분, 제 2 군이 $3.05\;{\pm}\;0.34$분으로 두 실험군간 통계학적으로 유의성 있는 차이가 없었다. 근관 충전재의 제거 후 근관 벽의 청결도는 두 실험 군 모두에서 치관부 1/3이 중간이나 치근단 1/3보다 우수한 결과를 보였으며 두 군 간의 차이는 없었다. 본 실험을 통해서 새로운 근관 충전 재료인 Resilon이 기존의 가타퍼챠와 실러를 사용한 충전과 비슷한 정도의 제거 용이성 및 근관 벽의 청결도를 보였음을 알 수 있었다.