• 제목/요약/키워드: resin

Search Result 7,495, Processing Time 0.033 seconds

Evaluation of Microleakage and Penetration Ability of Flowable Resin in Occlusal Fissure (유동성 레진의 교합면 열구내 침투도와 미세누출 평가)

  • Cheong, Hyeran;Im, Sungok;Lee, Sangho;Lee, Nanyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.89-98
    • /
    • 2017
  • The aim of this study was to compared the penetration scores and microleakage levels of flowable resin in comparison to resin-based pit and fissure sealant. A total 120 extracted premolars were used and classified with group I (resin-based pit and fissure sealant), group II (flowable resin), group III (bonding agent + flowable resin), IV (fissurotomy + bonding agent + flowable resin) depending on the materials and the application methods. The penetration scores of the group treated with flowable resin following fissurotomy were similar to those of the group treated with resin-based sealant, but higher compared to those of the other groups treated with flowable resin without fissurotomy or bonding agent. The group treated with flowable resin following fissurotomy also exhibited the lowest microleakage levels. The group treated with resin-based sealant and the one treated with a bonding agent prior to the application of flowable resin showed similar microleakage levels. In conclusion, flowable resin may be applied as a pit and fissure sealant, and its application along with fissurotomy could increase the penetration scores.

Urea Resin Treat Effects on Silk Textiles (요소수지를 주체로 한 편직물구조 개선연구)

  • 최병희;이양후;김한수
    • Journal of Sericultural and Entomological Science
    • /
    • v.20 no.1
    • /
    • pp.15-23
    • /
    • 1978
  • This studies have been carried out for several years to develop more better urea resin treating process on silk textiles which may be better crease resist without harming on the textile touch feeling. Specially, this paper payed attention to minimize the necessary formaldehyde content to be condensed with urea and created a new processing method which is named as Homo Metalic Urea Resin found to be better than urea resin process. The obtained results are as followings. 1. The prepared urea resin was found to be smell-less because of minimized formaldehyde content is the least than any other reports carried out before than this. 2. A new type of urea resin has been created by using uric 2incchloride and formaldehyde which is named as Homo Metalic Urea Resin. This processing method may carry both weighing process and urea resin process. 3. Crease resistance, stiffness and bulkiness were increased through such resin treats. Homo metalic urea resin process showed better results than the urea resin process. 4. Spun silk or low twisted silk have shown better crease resistance than raw silk or high twisted silk upon the both resin treats. 5. Both treat methods were found to be good economical feasibility upon the silk finishing process. 6. Tenacity and elongation of silk fibers were found to decrease some what because of grafting or weighing results. 7. Wooly silk has been also created with specific urea resin process. Such silk could be obtained by formaldehyde gas treat with urea soaken silk in a chamber, which induced to form scale on the surface of silk fibers.

  • PDF

Study on Performance of Water Vapor-Permeation Through Hydrophilic Polymer Membranes (친수성 고분자 막을 이용한 수증기 투과 성능에 관한 연구)

  • Rhim Ji-Won;Yun Tae-Il;Seo Moo-Young;Cho Hyun-Il;Ha Seong-Yong
    • Membrane Journal
    • /
    • v.16 no.2
    • /
    • pp.115-122
    • /
    • 2006
  • In this study the membrane preparation and water vapor permeation of the hydrophilic polymer materials, polyaminosiloxane and polyhydroxylsiloxane, used as the coating materials for the preparation of asymmetric flat and hollow fiber membranes were investigated. And the water vapor permeation towards air permeation and their permselectivity were intensively studied for the resulting Resin A/Resin C (coupling agent) and Resin B/Resin C membranes. The water vapor permeability for 3 wt% Resin C introduced into Resin A (Resin A/Resin C) membrane was higher than for 1 and 5 wt% membranes and also water vapor permeability increased with increasing operating temperatures. In addition, at this content of 3 wt% Resin C, the absorption capability became maximum through dynamic equilibrium absorption experiment. Water vapor permeability, 43578 Barrer (1 Barrer = $10^{-10}cm^3(STP){\cdot}cm/cm^2{\cdot}s{\cdot}cmHg$) and 53000 Barrer, and the selectivity of $P(H_2O)P(Air)$, 101.3 and 102.6 were shown at 25 and $35^{\circ}C$, respectively.

Comparison of microleakage after load cycling for nanofilled composite resin fillings with or without flowable resin lining (Nanofilled 복합레진으로 와동 충전 시 flowable 레진 사용 유무에 따른 피로시험 후의 미세 변연 누출 비교)

  • Han, Sun-Deok;Kim, Won;Choi, Ji-Young;Oh, Nam-Sik;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • Statement of problem: when using resin for class II restoration, micoleakage by instrumentation can be regarded as the primary negative characteristic. A review of the available literature suggests that using flowable resin as liner to decreased microleakage. Purpose: The aim of this study was to determine the influence of the nanofilled flowable resin lining on marginal microleakage after load cycling in class II composite restoration fillings using nanofiller resin. Material and methods: 24 extracted premolars were prepared with class II cavity. F group was restored the nanofilled resin with the nanofilled flowable resin as liner. NF group was restored the nanofilled resin only. After restoration, an experiment was performed on 2 groups using a 300N load at 104, 105 and 106 cycles. Prior to and before each load cycling, it was gauged length on total marginal microleakage, axial marginal microleakage and buccal, gingival, lingual marginal microleakage. Data were analyzed with the Mann-Whitney test & Kruskal-Wallis test. Results: There were statistically significant differences between 2 groups and between individual groups. (P <.05) The result showed less microleakage in teeth restored by the nanofilled resin, which was lined by the nanofilled flowable resin. Conclusion: There was significant reduction in microleakage when the nanofilled flowable resin lining was placed underneath the nanofilled resin in class II composite restoration fillings.

THE CHARACTERISTICS OF RESIN INFILTRATED INCIPIENT CARIOUS LESIONS (Resin infiltration을 시행한 법랑질 초기 우식 병소의 특성)

  • Kim, Eun-Young;Kwon, Min-Seok;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • The concept of resin infiltration which was born in an innovative philosophy to arrest the incipient caries. However, the structural changes of resin infiltrated lesions have not yet explained completely. The liquid resin might contribute not only to maximizing the penetration but to deteriorating physical stability. This study was performed to examine some physical and histological features of resin infiltrated incipient carious lesions. With the specimen of resin infiltrated lesions, microhardness by nanoindentation in depth profile, morphology of resin tags were revealed after HCl dissolution, and degree of microleakage were assessed. The percentage of microhardness of surface layer and lesion body of untreated specimen to sound enamel was 64.6% and 24.6% respectively, while that of resin-infiltrated lesions was 72.1%, showing significant difference (p<0.05). The resin tags observed under SEM had relatively homogeneous length of 433(282~501) ${\mu}m$ on the average. Among 20 specimens for microleakage assessment, 13 specimens showed no leakage while 5 and 2 showed leakage into outer and inner half of lesion respectively. It was thought the infiltrant resin penetrates deeply and homogeneously into lesion body and improves its hardness with relatively good physical stability.

Effect of polymerization temperature on the mechanical properties of provisional prosthesis resins (중합 온도가 임시 보철용 수지의 기계적 성질에 미치는 영향)

  • Hong, Min-Ho;Ha, Jung-Yun;Kwon, Tae-Yub
    • Korean Journal of Dental Materials
    • /
    • v.44 no.4
    • /
    • pp.311-318
    • /
    • 2017
  • The purpose of this study was to examine the effects of the curing sequence and polymerization temperature on the flexural strength and microhardness of two provisional resins (Bis-acryl resin composite and polymethyl methacrylate (PMMA)). Polymerization was carried out under various conditions, in air at $25^{\circ}C$ (control) and in hot water (40, 50, 60, 70, and $80^{\circ}C$). The flexural strength test was conducted according to ISO-4049. The Knoop hardness was measured. For the Bis-acryl resin, the temperature up to $50^{\circ}C$ did not increase the flexural strength nor the hardness of the bis-acryl resin composite (p>0.05) but higher temperatures increased the strengths. For the PMMA resin, flexural strength increased with temperatures up to $70^{\circ}C$ and then decreased slightly. Bis-acryl resin composite had higher mechanical properties than the PMMA resin. The effect of heat was more pronounced in the bis-acryl resin composite than in the PMMA resin (p<0.05).

Effect of artificial aging on mechanical and physical properties of CAD-CAM PMMA resins for occlusal splints

  • Julia Correa Raffaini;Eduardo Jose Soares;Rebeca Franco de Lima Oliveira;Rocio Geng Vivanco;Ayodele Alves Amorim;Ana Lucia Caetano Pereira;Fernanda Carvalho Panzeri Pires-de-Souza
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.227-237
    • /
    • 2023
  • PURPOSE. This study aimed to assess and compare the color stability, flexural strength (FS), and surface roughness of occlusal splints fabricated from heat-cured acrylic resin, milled polymethyl methacrylate (PMMA)-based resin, and 3D-printed (PMMA) based-resin. MATERIALS AND METHODS. Samples of each type of resin were obtained, and baseline measurements of color and surface roughness were recorded. The specimens were divided into three groups (n = 10) and subjected to distinct aging protocols: thermomechanical cycling (TMC), simulated brushing (SB), and control (without aging). Final assessments of color and surface roughness and three-point bending test (ODM100; Odeme) were conducted, and data were statistically analyzed (2-way ANOVA, Tukey, P <.05). RESULTS. Across all resin types, the most significant increase in surface roughness (Ra) was observed after TMC (P < .05), with the 3D-printed resin exhibiting the lowest Ra (P < .05). After brushing, milled resin displayed the highest Ra (P < .05) and greater color alteration (∆E00) compared to 3D-printed resin. The most substantial ∆E00 was recorded after brushing for all resins, except for heat-cured resin subjected to TMC. Regardless of aging, milled resin exhibited the highest FS (P < .05), except when compared to 3D-printed resin subjected to TMC. Heat-cured resin exposed to TMC demonstrated the lowest FS, different (P < .05) from the control. Under control conditions, milled resin exhibited the highest FS, different (P < .05) from the brushed group. 3D-printed resin subjected to TMC displayed the highest FS (P < .05). CONCLUSION. Among the tested resins, 3D-printed resin demonstrated superior longevity, characterized by minimal surface roughness and color alterations. Aging had a negligible impact on its mechanical properties.

Evaluation of the Effect of Various Root Planing Instruments on the Root Surfaces (수종의 기구를 이용한 치근면 활택술후 치근면의 변화)

  • Kim, Tae-Beom;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.65-80
    • /
    • 1999
  • The purpose of this study was to evaluate the effects of periodontal curet and various rotating instruments on the root surfaces. Thirty-five extracted teeth with advanced periodontal disease were used. They was root planed with periodontal curet, periodontal Perio-Clean bur, periodontal Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur. To find dentinal tubule orifices on the root surface, tetracycline HCI solution was applied to the one tooth of treated each group. Then, root surfaces were investigated using scanning electron microscope. Amount of loss of cementum was evaluated by loss of tooth substance index. The results were as follows. 1. Groups treated with periodontal curet and Perio-Clean bur showed irregular surface and concavities. Concavities seemed to be lacunae of cementocyte. Other groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur showed partially opened dentinal tubule orifice. 2. Groups treated with periodontal curet and Perio-Clean bur and tetracycline HCl showed irregular surface. No dentinal tubule orifice was seen. Other groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur and tetracycline HCl showed dentinal tubule orifice with various shape and size. 3. Loss of tooth substance indices were compared between groups. There was no statistically difference between periodontal curet and Perio-Clean bur groups. There were statistically differences between periodontal curet and Roto-Perio bur, ET bur, and diamond fissure bur groups. As a result of this study, groups treated with Roto-Perio bur, resin polishing ET bur, and resin polishing diamond fissure bur showed more cementum removed than groups treated with periodontal curet and Perio-Clean bur. Therefore, in a conventional treatment for periodontal disease, it was recommended that periodontal curet or Perio-Clean bur should be used. In a treatment for regeneration of periodontal tissue, it was recommended that Roto-Perio bur, resin polishing ET bur, or resin polishing diamond fissure bur should be used

  • PDF

THE EFFECT OF DENTURE CLEANSERS ON THE BOND STRENGTH AND THE SURFACE HARDNESS OF RELINE RESIN TO DENTURE BASE RESIN (의치 세정제가 의치상 레진과 이장용 레진의 결합강도와 표면경도에 미치는 영향)

  • Kim Kyea-Soon;Jeong Hoe-Yeol;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.493-502
    • /
    • 2003
  • Statement of problem : Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour and resorption of underlyng bony structure. Self-curing hard reline resins offers the immediate and relatively inexpensive means to be recondition the surface of denture base directly However weak bond between denture base resin and reline material can harbor bacteria, promote staining, or result in complete separation of the two materials. Purpose : The purpose of this study was to evaluate the effect of denture cleansers on bond strength and surface hardness of reline resin to denture base resin Denture base resin beams($60.0{\times}15.0{\times}3.0mm$) were made with Lucitone 199. Material and methods : 10mm section was removed from the center of each specimen. The samples were replaced in the molds and the space of l0mm sections were packed with Tokuso Rebase reline material. The specimens were immersed in denture cleansers (Polident, Cleadent) and were evaluated after 1 week, 2 weeks, and 4 weeks. The bond strength and surface hardness of self-curing hard reline materials to heat-curing denture base resin were measured using an UTM (universal testing machine). Results and conclusion : 1) There was no significant difference of usage, kind, and denture cleaner by application time on the bonding strength of self-curing hard reline resin to denture base resin. 2) There was no significant difference of usage, kind, and denture cleaner by application time on the surface hardness, but the surface hardness showed decreasing tendency, as the time of immersion was extended. 3) The failure modes of the specimens was initially adhesive failure and finally cohesive failure of self-curing hard reline resin.

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

  • Choi, Hyo-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.310-320
    • /
    • 2000
  • Statement of the problem. The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw relation and to align artificial teeth and try-in it in the mouth. The accuracy of jaw relation record is affected by the accuracy, stiffness and stability of the record base. So, the accuracy of record base is the most important requirements of jaw relation records. Purpose of study. The purpose of this study was to evaluate the gap that occurred over the palatal area of a maxillary record base fabricated with autopolymerizing resin and light-curing resin. Methods/material. The maxillary record bases were fabricated out of autopolymerizing resin that is used the most frequently in clinics and light-curing resin that attracts special attention for its several merits. The light-curing resin was made by two kinds of polymerization methods, which are one step curing method and multiple step curing method. All record bases were cut in certain positions of the master cast 1 hour and 1 day later after fabrication and the accuracy of the master cast was measured and analyzed with a microscope. Results. A pattern of gap formation between the record base and the maxillary cast was observed in all specimens. According to kinds of resins, autopolymerizing resin was significantly more accurate than light-curing resin. There was no statistical difference according to time lapse, and in all three groups, the maximum discrepancy occurred at the posterior border in the mid-palatal region. Conclusion. The autopolymerizing resin is better than light-curing resin, and multiple step curing method is more accurate than one step curing method when using light-curing resin.

  • PDF