• 제목/요약/키워드: residual phase

검색결과 697건 처리시간 0.028초

A Novel Cogging Torque Reduction Method for Single-Phase Brushless DC Motor

  • Park, Young-Un;Cho, Ju-Hee;Rhyu, Se-Hyun;Kim, Dae-Kyong
    • Journal of Magnetics
    • /
    • 제18권2호
    • /
    • pp.117-124
    • /
    • 2013
  • Single-phase, brushless DC (BLDC) motors have unequal air-gaps to eliminate the dead-point where the developed torque is zero. Unfortunately, these unequal air-gaps can deteriorate the motor characteristics in the cogging torque. This paper proposes a novel design for a single-phase BLDC motor with an asymmetric notch to solve this problem. In the design method, the asymmetric notches were placed on the stator pole face, which affects the change in permanent magnet shape or the residual flux density of the permanent magnet. Parametric analysis was performed to determine the optimal size and position of the asymmetric notch to reduce the cogging torque. Finite element analysis (FEA) was used to calculate the cogging torque. A more than 28% lower cogging torque compared to the initial model with no notch was achieved.

Evaluation of Shear-Induced Phase Transformation of $\beta$-Cristobalite by Fiber Push-Out Technique

  • Sang Jin Lee;Dong Zhu;Jae Suk Sung
    • The Korean Journal of Ceramics
    • /
    • 제3권3호
    • /
    • pp.208-212
    • /
    • 1997
  • Shear-induced phase transformation behavior of chemically stabilized $\beta$-cristobalite was studied by the fiber push-out technique. To obtain the critical grain size for phase transformation, the hot-pressed polycrystalline $\beta$-cristobalite, which was used as the interphase between fiber and matrix, was annealed at $1300^{\circ}C$ for 10h. Two types of fibers, mullite and sapphire fiber, were used in this study. Debonding between mullite fiber and cristobalite interphase occurred at a critical load of 230 MPa. Static friction and fiber sliding were continuously followed by debonding. Shear-induced transformation induced cracks in the cristobalite interphase at the debonding stage. In the case of the sapphire fiber, the debonding occurred at a lower load of 180 MPa due to the residual stress in the interface caused by the difference in thermal expansion coefficients between the fiber and the cristobalite interphase. The load was insufficient for shear-induced phase transformation.

  • PDF

저수조 내 잔류염소 감소에 미치는 주요 영향 인자에 관한 문헌연구 (A Review Study on Major Factors Influencing Chlorine Disappearances in Water Storage Tanks)

  • 노유래;김상효;최성욱;박준홍
    • 한국방재안전학회논문집
    • /
    • 제9권2호
    • /
    • pp.63-75
    • /
    • 2016
  • 안전한 수돗물 공급을 위해 정수처리장부터 최종 단계인 수도꼭지까지 일정 수준 이상의 잔류염소농도가 유지되어야 한다. 하지만 국내 문헌에 따르면 상수공급의 전체 과정 중에 30-60%의 잔류염소가 소실되고, 이에 대한 주요 원인으로 정수처리 과정에서 염소 사용량 감소 추세, 급수배관 내에서 염소분해 손실, 여름철의 높은 온도에 의한 잔류염소 분해 속도 증가, 급수배관의 노후화에 따른 잔류염소 손실, 저수조 내 저장 시 잔류염소 감소 발생 등이 파악되었다. 이러한 이유로 저수조를 거치는 급수 방식의 경우 최종 수도꼭지의 잔류염소 농도가 기준치보다 낮아질 개연성이 높고, 용량과 체류시간을 단순히 고려하는 기존의 저수조 설계 방식으로 인해서 수돗물 공급의 안전성에 대한 우려가 존재한다. 이의 개선 방안 도출을 위해서 본 연구에서는 저수조 내 잔류염소 감소에 관여하는 주요 기작들인 수체 내 잔류염소 분해, 벽체 표면 흡착, 그리고 증발에 의한 물질전달을 수학적으로 묘사하는 공식들과 계수 값들을 문헌을 통해서 획득하고, 일반적 저수조 조건에서 모델 시뮬레이션을 수행하였다. 그 결과 저수조에 유입되는 수돗물 내 유기물 농도, 수돗물이 저수조에 유입되는 수리학적조건(난류 정도), 그리고 저수조 벽체 표면 재질의 흡착능 등이 저수조 내 잔류염소 감소에 주요 영향 인자들임을 알 수 있었다. 본 연구에서 획득된 결과들은 잔류염소 감소를 최소화하여 안전한 수돗물 공급을 가능하게 하는 새로운 저수조 설계기법이나 기술 개발에 유용하게 활용될 것이다.

엑시며 레이저에 의해 형성된 다결정 실리콘 박막의 Angle wrapping에 의한 깊이에 따른 특성변화 (New Analysis Approach to the Characteristics of Excimer Laser Annealed Polycrystalline Si Thin Film by use of the Angle wrapping)

  • 이창우;고석중
    • 한국재료학회지
    • /
    • 제8권10호
    • /
    • pp.884-889
    • /
    • 1998
  • 대면적의 비정질 실리콘 박막을 가우스 분포(Gaussian Profile)의 일차원 선형빔(line shape beam)을 가지는 엑시머 레이저를 사용하여 결정화를 시켰다. (Corning 7059 glass)위에 증착된 비정질 실리콘 박막이 재결정화된 실리콘 박막의 경우, 두께에따라 결정화되는 모양이 다르게 나타났다. 따라서 두께에 따라 결정화되는 상태의 변화를 조사하기 위하여 angle wrapping 방법을 새롭게 도입하여 깊이에 따른 Si층이 5${\mu}m$ 이상되도록 angle wrapping한 후에 박막의 두께에 따른 micro-raman spectra를 측정하여 결정화상태에 따른 잔류응력을 조사하였다. 또한 기판의 온도가 상온인 경우에 엑시머 레이저의 밀도가 300mJ/${cm}^2$에서 열처리한 경우에 재결정화된 Si 박막의 잔류응력에 박막의 표면에서 박막의 깊이에 따라 $1.3{\times}10^10$에서 $1.6{\times}10^10$을 거쳐 $1.9{\times}10^10$ dyne/${cm}^2$으로 phase의 변화에 따라 증가하였다. 또한 기판의 온도가 $400^{\circ}C$에서 최적의 열처리 에너지 밀도인 300mJ/${cm}^2$에서는 박막의 깊이에 따른 결정화 상태의변화에 따라 thermal stress 의 값이 $8.1{\times}10^9$에서 $9.0{\times}10^9$를 거쳐 $9.9{\times}10^9$ dyne/${cm}^2$으로 변화하는 것을 알 수 있다. 따라서 liquid phase에서 solid phaserk 변화함에 따라 stress값이 증가하는 것을 알 수 있다.

  • PDF

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF

MSPD 전처리법과 HPLC를 이용한 Furazolidone의 계란내 잔류분석 (Matrix Solid-Phase Dispersion (MSPD) Isolation and Liquid Chromatographic Determination of Residual Furazolidone in Eggs)

  • 서계원;이재일;이채용;이정치
    • 한국식품위생안전성학회지
    • /
    • 제18권2호
    • /
    • pp.43-50
    • /
    • 2003
  • A liquid chromatographic method, using matrix solid-phase dispersion (MSPD) is developed for the extraction of residual furazolidone in chicken eggs. Blank or fortified egg samples (0.5 g) were blended with Octadecylsilyl (Bulk $C_{18}$, 40${\mu}{\textrm}{m}$, 18%. load, endcapped. 2 g) derivatized silica. After homogenization, $C_{18}$/egg and Na$_2$S $O_4$matrix were transferred to a column made of 10 ml glass syringe and filter paper and compressed 4.0∼4.5 ml volume. The column was washed with 8 ml of hexane and dried under $N_2$ gas. Furazolidone was eluted with acetonitrile (8 ml) under gravity. The eluate containing furazolidone was free from interfering compounds when analyzed by HPLC with UV detection (365 nm, photodiode array). Calibration curves were linear (r = 0.99985) and inter- (1.47%) and intra-assay (5.29%) variabilities for the concentration range examined (7.8∼497 ng/g of eggs, 20 ${mu}ell$ injection volume) were indicative of an acceptable methodology for the analysis of furazolidone. Average recovery of furazolidone added to egg was 96.2%. The limit of detection for the proposed method was 1 ng/g for furazolidone. The method using MSPD is proposed as an alternative assay to the classical method which involves the use of large volumes of a harmful solvent and requires a long tedious separation and clean-up processes prior to its determination.

H.264/SVC의 계층간 화면내 예측에서 보간법에 따른 부호화 성능 분석 (Performance Analysis of Coding According to the Interpolation filter in Inter layer Intra Prediction of H.264/SVC)

  • 길대남;정차근
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.225-227
    • /
    • 2009
  • International standard specification, H.264/SVC improved from H.264/AVC, is set up so as to promote free use of huge multimedia data in various channel environments.;H.264/AVC is a international standard speicification for video compression, adopted and commercialized as standard for DMB broadcasting by JVT of ISO/IEC MPEG and ITU-T VCEG. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding. Among prediction technologies, 'inter-layer intra prediction' is to use co-located block of up sampled sublevels as a prediction signal. At this time, application of interpolation is one of the most important factors to determine encoding efficiency. SVC's currently using poly-phase FIR filter of 4-tap and 2-tap respectively to luma components. This paper is written for the purpose of analyzing encoding performance according to the interpolation. For this purpose, we applied poly-phase FIR filter of '2-tap', '4-tap' and '6-tap' respectively to luma components and then measured bit-rate, PNSR and running time of interpolation filter. We're expecting that the analysis results of this paper will be utilized for effective application of interpolation filter. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding.

  • PDF

SPME를 이용한 Geosmin과 2-MIB분석 시 잔류염소의 영향에 관한 연구 (Effect of Residual Chlorine on the Analysis of Geosmin and 2-MIB Using SPME (Solid Phase Microextraction))

  • 김성진;홍성호;민달기
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.713-719
    • /
    • 2005
  • SPME (Soild phase microextraction) has been used in the analysis of many volatile organic compounds, such as geosmin and 2-methylisoborneol (2-MIB), trihalomethanes (THMs) in drinking water. SPME fiber is characterized by high adsorption capacity (DVB/CAR/PDMS, DVB/PDMS etc.). Although the highly active adsorption capacities of the SPME fiber are often to the chemical functional group, surface properties play a significant role in determining the surface adsorption capacities. The objectives of this study were to evaluate effect of residual chlorine on analysis of geosmin and 2-MIB. Image taken by SEM before preloaded with chlorine, the surface and porous media was almost perfect spherical shape and no clogging of pores. However, after preloaded with chlorine the surface was aggregated and pore was blocked. The recovery rate of geosmin and 2-MIB coexisting with chlorine was reduced by 35 to 62%. The recovery rate with preloaded with chlorine was reduced by 25 to 43%. The lower concentration of geosmin and 2-MIB and the higher concentration of chlorine existed in water, the lower the recovery rate was.

HF 증기상 식각과 열처리를 이용한 다결정 규소 미세 구조체의 제작 (Fabrication of Polysilicon Microstructures Using Vapor-phase HF Etching and Annealing Techniques)

  • 박경호;이춘수;정영이;이재열;이용일;최부연;이종현;유형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.603-605
    • /
    • 1995
  • We present a novel method. to fabricate surface micromachined structures without their sticking on the substrate. An anhydrous HF/$CH_3OH$ vapor-phase etching (VPE) of sacrificial $SiO_2$ layers was employed to release 0.5-2 {\mu}m$ thick polysilicon cantilevers. The fabricated structures were observed using scanning electron microscope and 3-dimensional optical microscope. The results show that we can successfully make cantilever beams up to 1200{\mu}m$ long without sticking. Annealing effects on residual stress of polysilicon microstructures were also investigated. Anneal ins at 1100$^{\circ}C$ for 1 hour was found to be effective to release the residual stress of the polysilicon microstructures. These VPE and anneal ins techniques will be useful in surface micromachining technologies.

  • PDF

Residual determination of Ceftiofur in Raw Bovine Milk by Liquid Chromatography-Electrospray Mass Spectrometry

  • Lim, Jong-hwan;Park, Byung-kwon;Kim, Myoung-seok;Jang, Beom-Su;Kim, Doo;Yun, Hyo-in
    • 대한수의학회지
    • /
    • 제44권3호
    • /
    • pp.367-371
    • /
    • 2004
  • This report describes the determination of ceftiofur residues in milk from treatment of lactating dairy cattle by intramuscular injection of three consecutive daily doses of about 1 mg /kg BW, the recommended label dosing. The separation of ceftiofur was achieved on $C_1_8$ reverse phase column. The mobile phase consisted of 0.1% trifluoracetic acid in water (A) and 0.05% acetic acid in acetonitrile (B) and grediently flowed at the flow rate of 0.4 mL/min. As a result of analysis of blank raw bovine milk samples, matrix interference was not shown. Limit of detection and limit of quantitaion was 0.5 ng/mL and 1 ng/mL, respectively. The values of precision and recovery satisfied the guideline of National Veterinary Research and Quarantine Service (NVRQS, Korea). The mean residual concentration of ceftiofur in milk did not exceed 3.71 ng/mL when ceftiofur was administered intramuscularly to lactating dairy cattle for 3 consecutive days at 1 mg/kg of BW per day. It is much lower than the proposed MRL (100 ng/mL) of ceftiofur in milk.