• 제목/요약/키워드: residential concentration

검색결과 355건 처리시간 0.024초

부산 지역 도로변과 주거지역의 NO와 NO2 농도 특성 (Characteristics of NO and NO2 at Roadside and Urban Residential Locations in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제27권7호
    • /
    • pp.587-595
    • /
    • 2018
  • This research investigated the characteristics of NO and $NO_2$ concentration at roadside (Choryangdong) and residential (Sujeongdong) locations in Busan. The NO concentration at roadside and residential were 34.7 and 8.0 ppb, respectively, and $NO_2$ at roadside and residential were 31.6 and $18.0ppb\;{\mu}g/m^3$, respectively. The NO concentration was the highest in winter at roadside at 37.1 ppb, followed by 35.0 ppb and 34.0 ppb in summer and fall, respectively. $NO_2$ concentration was the highest in spring at roadside at 39.6 ppb, followed by 30.4 ppb and 28.3 ppb in fall and winter, respectively. Number of exceedances per year of 1 hr limit value (0.10 ppm) for $NO_2$ at roadside and residential were 3,585 and 3 hours, respectively. Number of exceedances per year of 24 hr limit value (0.06 ppm) for $NO_2$ at roadside and residential were 32 and 1 days, respectively. Number of exceedances per year of 1 hr limit value (0.1 ppm) for $O_3$ at roadside and residential were 1 and 14 days, respectively. These results indicated that understanding the relationship between roadside and residential could provide insight into establishing a strategy to control urban air quality.

부산지역 도로변과 주거지역의 PM10과 PM2.5 농도 특성 (Characteristics of Fine Particles at Roadside and Urban Residential Locations in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제27권7호
    • /
    • pp.577-586
    • /
    • 2018
  • This research investigated the characteristics of $PM_{10}$ and $PM_{2.5}$ concentration at roadside (Choryangdong) and residential (Sujeongdong) locations in Busan. The $PM_{10}$ concentration at roadside and residential locations were 50.5 and $42.9{\mu}g/m^3$, respectively, and $PM_{2.5}$ at roadside and residential were 28.1 and $23.9{\mu}g/m^3$, respectively. The roadside/residential ratio of $PM_{10}$ and $PM_{2.5}$ concentration were 1.18, and the $PM_{2.5}/PM_{10}$ ratio at roadside and residential were 0.55 and 0.56, respectively. The $PM_{10}$ concentration in spring at roadside were $64.6{\mu}g/m^3$, and were the highest, followed by $48.0{\mu}g/m^3$ and $45.2{\mu}g/m^3$ in winter and summer. Number of exceedances per year of the daily limit value for $PM_{10}$ at roadside and residential were 66 and 39 days, respectively. The $PM_{10}$ and $PM_{2.5}$ concentration, and $PM_{2.5}/PM_{10}$ ratio at roadside were $53.0{\mu}g/m^3$, $29.0{\mu}g/m^3$ and 0.55 for day, and $45.5{\mu}g/m^3$, $26.7{\mu}g/m^3$ and 0.59 for night, respectively. These results indicate that understanding the relationship between roadside and residential could provide insight into establishing a strategy to control urban air quality.

겨울철 열섬 및 산소농도의 측정을 통한 주거지별 국지기후의 특성분석 (Analysis on Residential Micro Climate of the Urban Heat Island and Oxygen Concentration in Winter)

  • 황지욱;김소정
    • 한국환경과학회지
    • /
    • 제13권12호
    • /
    • pp.1023-1032
    • /
    • 2004
  • Rapid progress in urbanization has resulted in a change of the micro climate, especially in the urban area. In order to investigate the phenomenon of the heat island in the residential micro climate, a field survey was carried out by 4 sets of the residential type in Jeonju under typical winter synoptic condition. As analytic methode, it is used the comparison on the relation of the Land-to-Coverage Rate to Heat Island and Oxygen Concentration. And as a key question it is asked how stable characteristics of the micro climate will result from the survey of the Heat Island and the Oxygen Concentration, used as indicator. To ensure the trustworthy result of research, it is calculated the critical influence of the wind velocity and the Land-to-Covearage Rate. As a result of comparative analysis, it could be confirmed that the local temperatures in all sets of the residential type were higher than the average temperature in Jeonju. But the housing type A 'exclusive use for housing zone' has relativly the most stable and best living condition. On the contrary the residential type B and D has the worst toward the oxygen concentration in the time zone 9-12 a.m., which didn't reach the minimum of the oxygen concentration $20.5{\%}.$ It means that the higer the development and population density is, the worse is the situation of the Quality of Life in the residential types in accordance with the heat island and oxygon con­centration.

인체 호흡 영역에서의 대구시 대기질에 관한 연구 (Breathing Zone Air Quality in Taegu)

  • 조완근;손상호
    • 한국환경과학회지
    • /
    • 제5권1호
    • /
    • pp.7-14
    • /
    • 1996
  • Two experiments were conducted to evaluate breathing zone air quality in Taegu, using automatic analyzers for four air quality standards($SO_2$, $NO_2$, CO, and $O_3$). First, air target compounds were measured for 8 to 12 hours in each of two commercial areas and five residential areas. Second, air target compounds were hourly measured for 24 hours in each of two commercial areas, two residential areas, and an industrial complex area. Based on the first experiment the breathing zone air was more polluted in the commercial area as compared to the residential area, while the second experiment showed that the breathing zone air was polluted rather in the residential are3 as compared to the commercial area. The second experiment also indicated that there was some variation of breathing zone air concentration with time and measuring sites. Diurnal variation of breathing zone air concentrations was consistent with previous studies which measured at building height. The highest breathing zone air concentration was shown in Seongseo industrial complex area. An unusual finding of this study was that $SO_2$ concentration in the breathing zone air of Bisandong, a typical residential area of Taegu, was higher than that of other residential areas, even higher than that of Seongseo industrial complex area.

  • PDF

서울시 대기중 유기오염물질의 농도와 돌연변이원성에 대한 연구 (Atmospheric concentration and mutagenicity of organic pollutants of suspended particulate in Seoul)

  • 신동천;정용;문영한;노재훈
    • Journal of Preventive Medicine and Public Health
    • /
    • 제23권1호
    • /
    • pp.43-56
    • /
    • 1990
  • To evaluate the difference of concentration and mutagenicity of organic pollutants between residential and traffic area of Seoul, air samples were collected in Bulkwang (residential) and Shinchon (traffic) area. Samples were analyzed to measure the concentration of extractable organic matters (EOM) and their subfractions and mutagenicities were tested using Salmonella typhimurium TA 98. The concentrations of polycyclic aromatic hydrocarbons (PAHs) were also measured by gas-chromatography and compared between two areas. The results were as follows ; 1. While the concentration of total suspended particulate (TSP) in residential area was below the environmental standard in annual average, the concentration in traffic area was above the standard and was up to its maximum $256{\mu}g/m^3$ in November. The difference of TSP concentrations in both areas of each month was statistically significant (P<0.05). 2. The concentration of fine particle in traffic area was significantly higher compare to that in residential area and showed statistically significant monthly difference in both areas (P<0.05). The proportion of concentration of fine particle to TSP was 55-68%. 3. Mean concentrations of EOM in residential and traffic areas were $4.3{\mu}g/m^3\;and\;5.3{\mu}g/m^3$ respectively. The proportion of amount of EOM from fine particle to EOM from TSP was 70-88%. 4. While the percentage of polar neutral organic compounds (POCN) of fine particle in Bulkwang's sample was higher compare to Shinchon's sample, the percentage of aliphatic compounds of fine particle in Shinchon's sample was higher compare to Bulkwang's sample. The percentages of PAH fraction were as low as 6-10% in both areas. 5. The mutagenic activity of nit concentration of organic matters extracted from fine particle was higher compare to that of coarse particle and was increased when metabolically activated with S9. Mutagenicities with metabolic activation calculated by unit air volume were significantly different between residential and traffic area, $17\;revertants/m^3$\;and\;22\;revertants/m^3$ respectively. 6. The concentrations of benzo(a)pyrene in fine particle of traffic and residential areas were $3.10ng/m^3\;and\;2.02ng/m^3$ respectively. Sixteen PAHs were higher in samples of traffic area compare to residential area and also concentrations of PAHs in fine particle were higher compare to coarse particle.

  • PDF

부산지역 최근 4년간(2015~2018년) PM10과 PM2.5농도의 시·공간적 변화 특성 (Spaciotemporal Variation of PM10 and PM2.5 Concentration for 2015 to 2018 in Busan)

  • 전병일
    • 한국환경과학회지
    • /
    • 제29권7호
    • /
    • pp.749-760
    • /
    • 2020
  • This study investigates the characteristics of diurnal, seasonal, and weekly roadside and residential concentrations of PM10 and PM2.5 in Busan, as well as relationship with meteorological phenomenon. Annual mean PM10 and PM2.5 concentrations in Busan were 44.2 ㎍/㎥ and 25.3 ㎍/㎥, respectively. The PM2.5/PM10 concentration ratio was 0.58. Diurnal variations of PM10 and PM2.5 concentrations in Busan were categorized into three types, depending on the number of peaks and times at which the peaks occurred. Roadside PM10 concentration was highest on Saturday and lowest on Friday. Residential PM10 concentration was highest on Monday and lowest on Friday. Residential PM2.5 concentration was highest on Monday and Tuesday and lowest on Friday. PM10 and PM2.5 concentrations were highest on Asian dust and haze, respectively. The results indicate that understanding the spaciotemporal variation of fine particles could provide insights into establishing a strategy to control urban air quality.

신축 공동주택에서 플러쉬아웃에 따른 폼알데하이드 농도 저감 효과에 관한 연구 (Effects of Flush-out in the Reduction of Formaldehyde in Newly Built Residential Buildings)

  • 박상인;김주한;박준석
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.116-122
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out in the reduction of formaldehyde concentration in newly built residential buildings. The field measurements were conducted on two complexes of multi-residential buildings which are located in the suburban area of Seoul. About eight samples of residential buildings were selected to measure the changes in formaldehyde concentrations after flush-out from the two apartment complexes. The concentration of formaldehyde was measured using DNPH cartridge and HPLC. From the results of the field measurements, it was established that indoor formaldehyde concentration decreases 27.6~54.2% in the samples after flush-out. The number of days that the flush-out were conducted was noted to have no significant influence on the reduction rate of formaldehyde concentration when the flush-out continued more than 7 days. The comparison with Bake-out showed that flush-out also can reduce formaldehyde in newly built buildings as same levels of it.

실내 CO2 농도와 PIR 신호를 활용한 주거건물의 재실 추정 알고리즘에 관한 연구 (A Study on the Algorithm for the Occupancy Inference in Residential Buildings using Indoor CO2 Concentration and PIR Signals)

  • 이규남;정근주
    • 대한건축학회연합논문집
    • /
    • 제20권6호
    • /
    • pp.113-119
    • /
    • 2018
  • Occupancy-based heating control is effective in reducing heating energy by preventing unnecessary heating during unoccupied period. Various technologies on detecting human occupancy have been developed using complicated machine learning algorithm and stochastic methodologies. This study aims at deriving low-cost and simple algorithm of occupancy inference that can be implemented to residential buildings. The core concept of the algorithm is to combine the occupancy probabilities based on indoor CO2 concentration and PIR(passive infrared) signals. The probability was estimated by applying different levels of decrement ratio depending on CO2 concentration change rate and aggregated PIR signals. The developed algorithm was validated by comparing the inference results with the occupancy schedule in a real residential building. The results showed that the inference algorithm can achieve the accuracy of 75~99%, which would be successfully implemented to the control of residential heating systems.

국내 외국인 집중거주지의 유지 및 발달 - 서울시 대림동을 사례로 - (The Sustain Growth of the Foreigners' Residential Concentration in Korea : A Case Study of Daelim-dong, Seoul)

  • 이정현;정수열
    • 한국지역지리학회지
    • /
    • 제21권2호
    • /
    • pp.304-318
    • /
    • 2015
  • 최근 장기체류 외국인이 수적으로 증가하면서 이들의 집중거주지가 형성되었고 그것이 장기적으로 발달할 것으로 예견된다. 본 연구는 외국인 집중거주지가 유지되고 발달하는 동력과 과정을 살펴보고자 한다. 이에 국내 외국인 중 가장 수가 많은 중국 국적인의 대표적인 집중거주지인 서울시 대림동을 사례로 그들의 일상생활에 필요한 주거, 노동, 급양, 교육, 여가, 교통, 공동체 등 존재기본기능을 분석하였다. 그 결과 대림동은 모든 존재기본기능을 수행하면서 중국 국적인의 한국 생활을 용이하게 하고 나아가 신규 이주민을 흡인하는 것으로 드러났다. 외국인 이주민 집중거주지 형성에 대한 기존 논의는 선진국 출신 외국인에게는 '자민족 단합'을, 개도국 출신 외국인에게는 '이주국에서의 차별'을 주요 요인으로 보았다. 하지만 그 유지와 발달 측면에서는 개도국 출신 외국인의 집중거주지도 자민족 단합이 투영된 존재기본기능을 통해 성장함을 확인할 수 있었다.

  • PDF

미세먼지 입경농도 분포의 지역별 특성 (Regional Characteristics of Particle Size Distribution of PM10)

  • 이용기;이기종;이재성;신은상
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.666-674
    • /
    • 2012
  • The purpose of this study is to propose management strategies to lower the level of $PM_{10}$ concentration. First, this study analyzes the characteristics of particle sizes in three different areas, the residential, the roadside, and the industrial areas. Second, it has examined the size of particles which can influence on the increase of $PM_{10}$ concentration level. The distribution of particle size for $PM_{10}$ concentration was not different by regions. The highest portion in the observed $PM_{10}$ is near $0.3{\mu}m$. In addition, both near $2.5{\mu}m$ and near $5.0{\mu}m$ are found higher in portion. The fractions of $PM_{1.0}$ and $PM_{2.5}$ in $PM_{10}$ are 68.2% and 75.8% respectively. The fraction of $PM_{1.0}$ in $PM_{2.5}$ is 89.8%. The particle diameters contributed to the increase of $PM_{10}$ concentration are different by regions. In the residential area, the sizes of near $0.6{\mu}m$ and near $3.3{\mu}m$ particles are found to be the cause for the increase of $PM_{10}$ concentration level. However the particle sizes for the increase of $PM_{10}$ concentration level are $0.8{\mu}m$ and $0.5{\mu}m$ in roadside and industrial area respectively. Therefore, fine particles are found as the key factors to raise $PM_{10}$ concentration level in the two areas, while both fine and coarse particles are in the residential areas. When examined the $PM_{10}$ concentration level change, it was categorized by two different time zones, the high concentration level time and the lower concentration time. In high concentration time, the $PM_{10}$ concentration has increased in the morning in the residential and roadside areas. On the contrary, the level has increased in the evening in the industrial area. In low concentration time, the level of $PM_{10}$ concentration in the roadside area is significantly higher in the morning than the concentration level of other times. There is no significantly different concentration level found in the both residential and industrial areas throughout the day.