• Title/Summary/Keyword: reservoir level

Search Result 556, Processing Time 0.029 seconds

Operational Water Temperature Forecast for the Nakdong River Basin Using HSPF Watershed Model (HSPF 유역모델을 이용한 낙동강유역 실시간 수온 예측)

  • Shin, Chang Min;Na, Eun Hye;Kim, Duck Gil;Kim, Kyunghyun
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.6
    • /
    • pp.673-682
    • /
    • 2014
  • A watershed model was constructed using Hydrological Simulation Program Fortran to predict the water temperature at major tributaries of Nakdong River basin, Korea. Water temperature is one of the most fundamental indices used to determine the nature of an aquatic environment. Most processes of an aquatic environment such as saturation level of dissolved oxygen, the decay rate of organic matter, the growth rate of phytoplankton and zooplankton are affected by temperature. The heat flux to major reservoirs and tributaries was analyzed to simulate water temperature accurately using HSPF model. The annual mean heat flux of solar radiation was estimated to $150{\sim}165W/m^2$, longwave radiation to $-48{\sim}-113W/m^2$, evaporative heat loss to $-39{\sim}-115W/m^2$, sensible heat flux to $-13{\sim}-22W/m^2$, precipitation heat flux to $2{\sim}4W/m^2$, bed heat flux to $-24{\sim}22W/m^2$ respectively. The model was calibrated at major reservoir and tributaries for a three-year period (2008 to 2010). The deviation values (Dv) of water temperature ranged from -6.0 to 3.7%, Nash-Sutcliffe efficiency(NSE) of 0.88 to 0.95, root mean square error(RMSE) of $1.7{\sim}2.8^{\circ}C$. The operational water temperature forecasting results presented in this study were in good agreement with measured data and had a similar accuracy with model calibration results.

Design of the spillway for dams with concentration of inflow in short time and reservoir water level rapidly. (단시간 유입량 집중 및 수위 급상승 댐의 여수로 계획)

  • Kim, Woon-Tae;Kang, Tae-Ho;Han, Jeong-Sik;Choi, Byung-Kyu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.478-478
    • /
    • 2011
  • 중소규모 댐 계획시, 댐 하류 홍수피해 저감, 합리적 운영, 유지관리 및 경제성 측면올 고려한 댐 계획은 무엇보다 중요하다. 지금까지 국내에서 계획/건설된 대규모 뱀에서와는 달리, 비교적 작은 규모의 유역에 있어서 댐 계획은 댐 유역 및 저수지의 수리 수문학적 특성 즉, 빠른 시간에 홍수량의 저수지 유입으로 저수지 수위가 급상승하는 등, 일반적인 기존 댐들과는 다른 특정을 지닌 중소규모유역 댐의 여수로 계획을 소개하고자 한다. 여수로 계획을 한 댐 유역의 특성으로 유역면적 약 $33km^2$, 총저수용량 2,211 만 $m^3$, 홍수조절용량 349만 $m^3$의 소규모 저수지를 가진 댐이다. 지방하천 최상류에 위치하는 유역면적이 작은 댐에서의 일반적인 수문학적 특징은 홍수도달시간이 1 시간 내외로 빠르고, 저수지 수위상승 속도가 0.2~0.3m/분 정도로 빠르게 나타난다. 이러한 수리 수문학적 특징 때문에 댐 여수로 수문 조작시간이 충분치 않으므로, PMF 유입과 같은 긴급한 상황에서는 댐을 월류할 가능성을 배제할 수 없다. 따라서 일반적으로 대규모 댐의 여수로 수문을 이용, 단독으로 홍수조절을 수행하던 기존 댐들과는 달리 소규모 댐에 적합한 특성을 지닌 여수로 계획의 필요성이 대두된다. 검토대상 여수로 형식으로는 국내 다목적댐에서 대부분 채택하고 있는 조절형 여수로, 무문식 여수로를 도입한 조절형+비조절형 여수로, 방류관식 여수로, 복합형 여수로 등을 안전성, 유지관리성 및 시공성 측면 등을 다각적으로 검토하였으며, 그 결과로 소규모 댐의 여수로 형식으로는 조절형+비조절형 여수로가 가장 적합한 형식이라고 판단하였다. 그러나, 여수로 형식 이 조절형+비조절형과 같이 폭이 100m가 넘는 광폭의 여수로에서 등폭 도수로를 채택할 경우 감세공의 폭이 과다해지는 문제점은 등폭 도수로와 도수로 끝단부에 도류벽을 설치하여 유수 에너지를 도류벽에서 1 차 감세한 후 댐에서 보편적인 정수지형 감세공으로 유수를 소통시키는 형식으로 계획하였다. 이러한 측수로형 감세공을 도입하여 정수지형 감세공 규모를 줄이는 경제적인 효과도 얻을 수 있도록 계획하였다.

  • PDF

Impact of Pig Slurry from WangGoong Farm Cluster on Water Quality of the Iksan Stream

  • Choi, Hong-Lim;Suresh, A.;Babu, T.;Mansyur, Mansyur
    • Journal of Animal Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.549-561
    • /
    • 2011
  • Livestock wastewater is being discharged without treatment from Hasen's pig farm cluster in WangGoong (WG) area into the Iksan Stream, eventually flowing into the ManGyung (MG) at the upstream junction. Although it is well known that before discharge, wastewater must satisfy the pig slurry discharge standards; because of ongoing remodeling, proper treatment is not being performed. According to public records, wastewater from the WG pig farm cluster is responsible for 3.6% of MG River pollution and 2.0% of the SaeManGuem (SMG) Reservoir pollution. As a result, upstream water treatment quality has become primary concern for development of the SMG project. All physicochemical constituents and pathogenic microbes, such as chemical oxygen demand ($COD_{Cr}$), biochemical oxygen demand ($BOD_5$), total suspended solids (TSS), total nitrogen (TN), total phosphorous (TP), fecal coliforms, Escherichia coli and Salmonella at the effluent of WG Plant (S-1) exceed the effluent standards. This is mainly due to insufficient wastewater treatment: the WG Plant is under renovation to increase water purification efficiency. By comparing the water quality at the S-7 junction, where the the Iksan Stream (pig farms) and the Wanggoong Stream (no pig farms) merge, it is clear that farming facilities and improper treatment can critically affect surrounding water quality. While it is clear throughout this study that the level of all physicochemical parameters and pathogenic microbes along the Stream decreased due to sedimentation, biodegradation and/or dilution. An alarming problem was discovered: the existence of pathogenic microbe count(E coli, Salmonella) in the lagoon wastewater and the stream water. Not only were high concentrations of these pathogens themselves found, but the potential existence of more serious pathogens could rise to more dangerous conditions.

The experimental study for hemodynamic changes in the heart-lung preparatio by autoperfusion (자가관류법에 의한 체외심폐의 혈역학적 변동에 관한 실험적 연구)

  • 한승세
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.179-190
    • /
    • 1989
  • The experimental study for extracorporeal preservation of the heart-lung preparation by autoperfusion system was performed in 10 dogs. Under intravenous Pentothal endotracheal anesthesia bilateral thoracotomies were performed. A 24F cannula connected to a plastic reservoir bag located 100 cm above the level of the heart was introduced into the aortic arch. Left subclavian, innominate artery, and descending aorta were ligated and divided. Both vena cavae were ligated and divided after the bag was half filled with blood. A 24F catheter inserted into right atrium and connected to the plastic bag in order to keep constant the preload. The thoracic trachea was intubated and the lungs were ventilated. The heart-lung preparations were removed en bloc and floated in a $34^{\circ}C$ bath of Hartmann solution. The preparations were observed for from 2 hours to 8 hours, with the average of 5.2 hours. Hemodynamic and hematologic variables were measured during preharvest and autoperfusion. The pH revealed severe respiratory alkalosis due to very low $PaCO_2$ during autoperfusion ; $PaO_2$ remained constant for 130-140 mmHg; $A-aDO_2$ increased markedly. The static inspiratory pressure [SIP] at late autoperfusion [6hr] increased significantly as compared with at early autoperfusion [2hr]. There was no difference between white blood cell counts from right atrium and those of left atrium. Heart rates remained constant for 110-120/min; cardiac outputs maintained to approximately 0.6L/min; mean aortic pressures, 75 mmHg; mean pulmonary arterial pressures, 15-18 mmHg; mean right atrial pressures, 9-13 mmHg; mean left atrial pressures, 12 mmHg lower than those of right atrium. Serum Na maintained with normal range during autoperfusion; K increased significantly; Ca decreased progressively. Hemoglobin and hematocrit decreased significantly during autoperfusion. The study demonstrated that stable hemodynamics could be maintained throughout the experiment and the preparation of the lung seemed to be inadequate, especially after 3-4 hours, such as high $A-aDO_2$, increased SIP, and scattered atelectasis and edema in their gross appearances.

  • PDF

Semi-Continuous Electrowinning of LiCl-$Li_2O$ Molten Salt (LiCl-$Li_2O$ 용융염에서의 리튬의 반연속적 전기정련)

  • Jin-Mok, Hur;Chung-Seok, Seo;Sun-Seok, Hong;Dae-Seung, Kang;Seong-Won, Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.211-217
    • /
    • 2004
  • A Li recovery technology has been developed and related experimental verification efforts were carried out to improve the economical viability and environmental friendliness of the 'Advanced Spent Fuel Conditioning Process' being developed at KAERI. This technology is characterized by the combination of 1) the electrolysis of $Li_2O$ in a molten salt by using a porous non-conducting magnesia container at the cathode, 2) the separation of the Li in the container from the molten salt by elevating the container above the level of a molten salt, 3) the transport of the Li in the container by using a vacuum siphon to a separated reservoir. Li was semi-continuously recovered from a LiCl-$Li_2O$ molten salt with a more than 95% yield by using the developed technology.

  • PDF

Optimum Size Analysis for Dam Rehabilitation Using Reliability Analysis (신뢰성 분석을 통한 기존 댐 재개발의 적정규모 결정의 관한 연구)

  • Kwon, Hyun-Han;Moon, Young-Il;Choi, Byung-Gyu;Yoon, Yong-Nam
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.2
    • /
    • pp.97-110
    • /
    • 2005
  • This paper presents a procedure of evaluation of reservoir capacity for additional water storage for dam rehabilitation. One of the techniques on the extension of rainfall has been developed, and the daily stream flows were simulated by the NWS-PC long-term rainfall-runoff model with the input of the extended daily rainfall which was stochastically generated by the nonhomogeneous markov chain model. We peformed a reliability analysis to Guisan dam about the optimal capacity of dam rehabilitation by using performance criteria that Hashimoto et al. (1982) presented. We estimated that the most suitable water level is approximately 155EL.M. suggested that this method can use supplemental methods to estimate optimum dam scale.

Water Quality Assessment using Trophic Status Index and Attached Diatom Index in 10 Reservoirs including Ye-dang Reservoir of Chungcheongnam-do (충남 예당저수지를 포함한 10개 저수지의 영양단계 및 부착규조지수를 이용한 수질평가)

  • Song, Mi-Ae;Kim, Ji-Won;Kim, Hun-Nyun;Kong, Dong-Soo;Lee, Ok-Min
    • Korean Journal of Ecology and Environment
    • /
    • v.44 no.2
    • /
    • pp.155-171
    • /
    • 2011
  • The research assessed water quality using physico-chemical factors, trophic status index and attached diatom index in 10 reservoirs located in Chungcheongnam-do from October 2007 to June 2008. The physico-chemical water quality assessments revealed that Dangjin-gun (St. 1~5), which displayed a high chemical oxygen demand (V and VI) and chlorophyll-${\alpha}$ (Eutrophic-Hypereutrophic), was more polluted than Yesan and Cheongyang-gun. The sample were also hypereutrophic [trophic status index (TSI) 74.6] and ${\beta}$-mesosaprobic [diatom assemblage index to the organic water pollution (DAIpo) 44.47]. Yesan and Cheongyang-gun. Which were mid-level in their pollution status, were eutrophic (TSI 56.9) and ${\alpha}$-oligosaprobic (DAIpo 60.11). TSI correlated strongly with the attached diatom index (of DAIpo 0.60~0.62, and trophic diatom index of 0.72~0.74). Hence, the attached diatom index can be used with the trophic status assessment of lakes using TSI, and lake trophic status index (LTSI).

Determination of Cadmium(II) and Copper(II) by Flame Atomic Absorption Spectrometry after Preconcentration on Column with Pulverized Amberlite XAD-4 with Bismuthiol I

  • Park, Dong-Seok;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.8
    • /
    • pp.1375-1382
    • /
    • 2007
  • A column preconcentration method with pulverized Amberlite XAD-4 loaded with bismuthiol I (BI) has been developed for the determination of trace Cd(II) and Cu(II) in various real samples by flame atomic absorption spectrophotometry. Various experimental conditions, such as the size of XAD-4, adsorption flow rate, amount of bismuthiol I, stirring time for adsorbing bismuthiol I on XAD-4, pH of sample solution, amount of XAD-4- BI, desorption solvent, and desorption flow rate, were optimized. Also, the adsorption capacity and the adsorption rate of Cd(II) and Cu(II) on XAD-4-BI were investigated. The interfering effects of various concomitant ions were investigated, Bi(III), Sn(II) and Fe(III) were found to affect the determination. But the interference by these ions was completely eliminated by adjusting the amount of XAD-4-BI resin to 0.70 g, although the adsorption flow rate was slower. For Cd(II) our proposed technique obtained a dynamic range of 0.5-40 ng mL-1, a correlation coefficient (R2) of 0.9913, and a detection limit of 0.3 ng mL-1. For Cu(II), the corresponding values were 2.0-120 ng mL-1, 0.9921 and 1.02 ng mL-1. To validate this proposed technique, the aqueous samples (stream water, reservoir water, tap water and wastewater), the diluted brass sample and the plastic sample, as real samples, were used. Recovery yields of 91-103% were obtained. These measured data were not different from ICP-MS data at 95% confidence level. Our proposed method was also validated using rice flour CRM (normal, fortified) samples. From the results of our experiment, we found that the technique we present here can be applied to the determination of Cd(II) and Cu(II) in various real samples.

Empirical Formula of Delay Time for Groundwater Recharge in the Representative Watersheds, Jeju Island (제주 대표유역에 대한 함양지체시간의 경험식)

  • Kim, Nam Won;Na, Hanna;Chung, Il-Moon;Kim, Youn Jung
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.9
    • /
    • pp.743-752
    • /
    • 2014
  • Delay time for groundwater recharge means the travel time from the bottom of soil layer to groundwater through vadose zone after infiltration from rainfall. As it is difficult to measure delay time, we suggested an empirical formula which is derived by using linear regression between altitude and delay time. For the regression analysis, 4 major gauging watersheds were chosen (Hancheon, Kangjeongcheon, Oedocheon, Cheonmicheon) with 18 measured groundwater level stations. To verify this empirical formula, derived equation from linear reservoir theory was applied to compute delay time and to compare estimated amounts of groundwater recharge using both methods. The result showed good agreement. Furthermore, if derived empirical formula would be linked with SWAT model, the spatial time delay effect in the watershed could be reflected properly.

Analysis on the sediment sluicing efficiency by variation of operation water surface elevation at flood season (홍수기 운영수위 변화에 따른 배사 효율 분석)

  • Jeong, Anchul;Kim, Seongwon;Kim, Minseok;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.971-980
    • /
    • 2016
  • In general, efficient operation of sediment sluicing is important in economical aspect. In this study, the efficiency of sediment sluicing by various operation at water surface elevation on multi-functional weirs were analyzed using Nays2DH, and we focused on the Dalsung weir at Nakdong river. The results of this study shows that, the same number of flushing channels and water gates were developed due to sediment sluicing, and sediment deposition occurred in upstream region of flushing channels. Also, the sediment sluicing efficiency increased by approximately 4.6% and sedimentation decreased by approximately 4.5% at EL. 14.5 m for operations on water surface elevation exceeding EL. 14.0 m. The mitigation of reservoir sedimentation and extension of maintenance dredging period are possible if the variation of sediment sluicing efficiency in various operation at water surface elevation during flood season are considered.