• Title/Summary/Keyword: required rooms

Search Result 156, Processing Time 0.03 seconds

A Research on the Total Emergency Room Time for Child Patients under 14 years suffering from External Injuries using Medical Information (의료정보를 활용한 14세 이하 외상환자 응급실 총 경유시간에 미치는 요인)

  • Jeon, Eun-Ju;Kim, Kwang-Hwan
    • Korea Journal of Hospital Management
    • /
    • v.13 no.4
    • /
    • pp.27-45
    • /
    • 2008
  • This research focused on a total of 378 patients with external injuries under the age of 14 who visited the emergency center at a university hospital in Korea, during the months of January, April, August and November between January and December of 2007. In addition, the survey was conducted only on even number days and ranged across the whole year to reflect the impact of seasonal characteristics on the collected data. The research focused on determining the characteristics and inflicting cause of these patients with external injuries, analyzed the total time spent in the emergency room and obtained the following results. 1. When classifying the patients into different genders, the proportion of males (67.5%) was higher than that of females (32.5%). According to the different age groups, the highest ratio, at 61.1 %, was patients under the age of six. 2. Looking at the total number of minutes spent in the emergency room, the longest amount of time occurred during April with 162.7 minutes, followed by 121.9 minutes in January and 92.4 minutes in November. August had the shortest period of time spent in the emergency room, a significant statistical difference from the other periods of the year (p<0.001). 3. Regarding the amount of time required for each examination, patients required to provide a urine test spent an average of 204.7 minutes while those who did not spent 113.5 minutes on average. This is a 5% statistical difference among the two groups (p>0.05). 4. Looking at the five most commonly diagnosed problems in the emergency room, the total number of people with these top five commonly diagnosed illnesses comprised 55.6%, or 210 patients out of 378. 5. Utilizing the Decision Tree Model to estimate the total number of minutes required per visit, the first classifications were made using a chemical examination factor. People subject to chemical classification spent an average of 177.7 minutes, which was longer than the overall average of 115.2 minutes, and those exempt from chemical examination spent an average of 103.8 minutes, which was shorter than the average Conclusion; Effort to curtail the total time spent in emergency rooms is vital in guaranteeing efficient management of hospitals and providing medical services. The delay experienced by many comprehensive professional medical centers must be resolved through the establishment of effective delivery of medical services, increased supply of patient rooms and other policy oriented implementations. However, for now, this problem must be resolved by increasing the level of patient satisfaction and guaranteeing effective operation of patient rooms, which will significantly contribute to the general management and success of hospitals and institutions.

  • PDF

A Result of Field Survey for Ergonomic Work Risk Factors in General Hospital (의료업종의 작업위험요인에 대한 실태조사 결과)

  • Kim, Jin-Young;Kim, Yeong-Mee;Kim, Day-Sung;Im, Heung-Jae;Kim, Jeung-Ho;Kang, Seong-Kyu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.91-100
    • /
    • 2007
  • The purposes of this research are to survey work-related risk factors of musculoskeletal disorders(MSDs) in various departments and tasks at general hospitals in non-manufacturing sectors, and to use basic data derived from the survey results in preventing work-related MSDs in hospital workers. Investigation started in March of 2006 and continued for 6 months in 220 general hospitals at Seoul, Incheon, Kyeongi, and Kangwon area. Investigators visited and interviewed workers in hospitals to identify the presence of tasks of musculoskeletal burden, the investigation results of ergonomic risk factors required by the Occupational Safety and Health Law, statistical analysis from questionnaire for musculoskeletal symptoms, and major departments and tasks that have such risk factors. Twenty-seven percents of hospitals finished the investigation of ergonomic risk factors, and 69% did not do the investigation while remained 4% did not have such factors in their hospitals. The rank order of major departments that had such musculoskeletal burdens was kitchen rooms of 143, managing departments/computer rooms/dispensaries of 137, physical treatment rooms of 109, nursing departments of 96, radiological and clinical laboratories of 63. Eighteen hospitals that did not hold legal duties by the section 148 of labor minister decree practiced prevention programs of MSDs according to the labor-management cooperation. Nursing departments ranked in the first place for the numbers of musculoskeletal symptoms of 438. Managing departments/computer rooms/dispensaries, kitchen rooms, and medical treatment departments held 127, 52 and 45 symptoms, respectively. The magnitude order of physical symptom areas followed shoulder of 185, backs and waist of 166, hand wrists of 120, necks of 110, and legs/feet of 106. The departments and jobs that had major work-related ergonomic risks were patient transporting, central supplying, patient nursing (moving patients into wheel-chairs, changing of patient posture and sheet alteration), manual transporting, operation, and managing/computer departments.

A Study on Methods for Utilizing Digital Room in Public Library (공공도서관 디지털자료실 활성화 방안 연구)

  • Moon, Sung-Been;Kim, Pan-Jun;Lee, Mi-Kyeung
    • Journal of the Korean Society for information Management
    • /
    • v.26 no.1
    • /
    • pp.321-350
    • /
    • 2009
  • The purpose of this study is to find methods for utilizing digital room in public library and its efficient operation by analyzing the status quo of the digital rooms in public libraries, which had been built nation-widely about 5 years ago. It is found that it is urgent to supplement and improve the infrastructure of them. It is also required to build multi-functional digital rooms and an integrated operational system for digital rooms. Implementation of an integrated operational system, first of all, for applicable sections of digital room may be the best alternative. The multi-functional digital rooms can be built, which, in addition to its traditional function, can include a variety of original information resources and function of information creation using application programs, as well as functions such as education, information services, online/offline community creation, and activating information sharing. In the future, the digital rooms in public libraries must play a significant role as online/offline spaces, which are not the places for use and access to internet information resource, but for information/knowledge sharing and collaborative activities. It also must provide a communication channel between librarians and users as well as among users themselves.

Relationship between the Distribution of Space doses in X-ray Rooms and the "Inverse Square Law of Distance" (X선 촬영실 내 공간선량의 분포와 거리 역자승 법칙과의 관련성)

  • Choi, Seong-Kwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.301-307
    • /
    • 2013
  • In the present study, space doses generated during X-ray radiography of hand, head, and abdomen, etc. were examined and whether the intensity of space doses of scattering rays is attenuated by the "inverse square law of distance" was figured out. First, the space doses of X-ray with small amounts of generated scattering rays such as hand radiography were mostly attenuated by the "inverse square law of distance" and were not detected at all at a distance of 2m. Second, the space doses of X-ray with large amounts of generated scattering rays such as head or abdomen radiography attenuated in higher rates than the rates under the "inverse square law of distance" at distances ranging from 30cm to 1m from the center of the irradiation field and were attenuated by the "inverse square law of distance" at distances ranging from 1m to 2m. Therefore, in X-ray rooms, the subject should be at least 2m away from the center of the irradiation field in the case of hand radiography and X-ray exposure prevention actions using protective devices are required in the entire spaces of the X-ray rooms in the case of head or abdomen radiography.

Evaluating Appropriateness of Medication Use in the Operating Rooms of a Tertiary Hospital: Based on Survey (일개 병원의 수술실 약제관련 업무 적정화 방안연구: 설문조사를 중심으로)

  • Lee, Ye Ji;Jeong, Kyeong Hye;Kim, Young Nam;Kim, Eun Young
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.3
    • /
    • pp.230-237
    • /
    • 2016
  • Background: Since the use of opioid analgesics is frequent in operation rooms (OR), the risk of medication error is high; however the use of medication in the OR has been operating independently with the hospital pharmacy. Therefore, the assessment on management of medication use in operation and the pharmacist's role is needed. Methods: We conducted the literature review and survey from anesthesiologists, operating nurses at Chung-Ang Hospital on management of medication for operation use, awareness on need for medication management efficiency, need for satellite pharmacy in the operating room and its effect. Results: 56% of medical staffs responded that management of medication in the operating room is efficient; however, 82.6% responded that they felt the inconvenience in medication delivery to the OR when additional prescription was ordered. 51.5% also responded that extra time was required for management of narcotics and inventory/record keeping. 80% agreed that there could be lost costs due to prescription missed. Medical staffs responded improving the drug management system could increase the OR efficiency (87%), and eventually bring the increase in hospital revenue (80.4%). Those who responded that implementation of OR satellite pharmacy was needed include physicians (84.6%), nurses (63.6%), and also responded that it'd bring more profit to the hospital by increasing the efficiency in OR (60.9%). Conclusion: For efficient management of medications, implementation of OR satellite pharmacy would lead to improved drug management and increased efficiency in OR and reduced cost and improved patient care.

A Study on Design Elements of Main Control Room in Nuclear Power Plants by Analyzing Space Characteristics (원자력발전소 주제어실의 공간특성에 따른 디자인 요소에 관한 연구)

  • Lee, Seung-Hoon;Lee, Tae-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.6
    • /
    • pp.249-256
    • /
    • 2010
  • For guaranteeing for security of nuclear power plant, ergonomic factors have been applied to design of main control room, core area for management and control of nuclear power plant, but design elements for performance of operators have been ignored. As the behaviors of operators are important for security of nuclear power plant, space design which makes them pleasant psychologically and makes them maintain attention on security equipments ceaselessly is required. Therefore, the purpose of this study is to analyze space characteristics of main control rooms according to regulations of nuclear power plant and general guidelines of space design, and to offer basic data for designing of main control room which makes operators pleasant psychologically and physically. At first, theoretical issues related with design of main control room are reviewed and several premises of space are developed by abstracting design elements from common space and regulations of nuclear power plant and, then integrating each design elements interactively. In short, the improvement of system environment based on human-machine interface space has brought about perceptual, cognitive, and spatial changes and has realized next generation of main control rooms. And, differences and similarities between ordinary space and main control room, which ergonomic sizes and regulations are applied and is VDT environment based on LDP, are discussed in relation to 13 design elements and 17 space premise.

A Study on the Architectural Planning of the Angiography Unit in General Hospital (종합병원 혈관조영촬영유니트의 건축계획에 관한 연구)

  • Yun, Woo-Yong;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.2
    • /
    • pp.69-77
    • /
    • 2006
  • Angiography means that a check up to know an abnormal condition in all the blood vessels include from the heart, aortae, cerobrovascular and abdonominal artery to hands and feet. Main examples of this are cerebral angiography, abdominal, liver for urinary anomaly, renovascular angiography, and artery and vein in arms and legs. Angiography uses radial rays or angiography equipment for an image output during interventional procedure and compositive diagnosis. The acts which performed in a projection room have changed drastically. In general, it is performed by using equipment which is attached one or two C-arms and the method of inserting catheter in vein after anesthesia. For this reason, some rooms that consist of angiography room units should be planned not only for expensiveness equipment and facilities also to be germ-free. Nowadays, in the angiography unit case, it is placed independently as the central part of many hospitals. It does not belong to the imaging medical department any more as considering raising filming times and the relation between C.C.U.(coronary care unit) and operation unit. This means the acts performed are diversified and well-organized rooms in support of diagnosis are required. However, it is difficult to plan the angiography room unit due to domestic researches and data on this unit are not enough. Therefore, this study aims at bringing up basic issue for architectural planning of the angiography unit in general hospital.

  • PDF

A Study on Space Planning of High School Considering the Management Realities of Education Curricula (교육과정 운영실태를 고려한 고등학교의 공간계획에 관한 연구 - 방과후 활용을 중심으로 -)

  • Lee, Jae Lim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.3 no.2
    • /
    • pp.51-74
    • /
    • 2003
  • This study has presented construction planning data or material. which can maximize the efficiency of school facilities; in other words, to utilize school facilities as local continuing education facilities in terms of use rate, as well as to make school facilities to accommodate the 7th education curricula. This study has been carried out through questionnaire survey on currently executed various curricular operation types, targeting people in charge of drawing up and operation of the curricula in liberalarts high school. The questionnaire survey has also been conducted on ideal teaching-learning type by subject, targeting teachers in charge of individual subject. The expansion of specialized curricula rooms and classrooms, as well as classrooms by level and ICT-related rooms, are required to invigorate continuing education, which utilizes smooth operation of the 7th education curricula and school facilities. I also assume that implementation of school curricula and the role as local continuing education facilities can be fulfilled, through activated deployment type and operation programs with which management of the facilities becomes easy, in order to utilize those classrooms to be used for continuing education.

  • PDF

Human Factors Evaluations of Alarm Displays in Main Control Rooms

  • Choe, Pilsung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • Objective: This study proposes an alarm display and compares it with the one(alarm tile display) widely used in main control rooms(MCRs) of nuclear power plants. Background: Catching up with the rapid development of computer technologies, advanced MCRs has been required. Using modern technologies of computers and visual displays, we have a lot of potential to improve user performance and satisfaction as well as safety in MCRs. Method: The alarm bar display has been proposed to reduce some potential problems of the alarm tile display in this study. Human factors evaluations were conducted to compare both types of displays. Two interfaces of bar alarm and tile alarm were simulated on the desktop computer for the user-involved experiment. Eight students participated in the experiment with the within-subject design. Results: The alarm bar was slightly better in terms of situation awareness, and preferred to understand alarm dynamics. The alarm tile was slightly or significantly better in other measures. Conclusion: Both alarm displays have their own advantages and disadvantages. Therefore, combining benefits of both displays can be used to optimize the design of alarm displays. Application: The proposed display is expected to compensate the existing displays for certain purposes.

A Study on Verification for the Design of Bio Safety Level 3 Laboratory by using Multi-zone Simulation (멀티죤 시뮬레이션을 이용한 생물안전 3등급(BSL3)시설의 설계 검증에 관한 연구)

  • Lee, Hyun-Woo;Choi, Sang-Gon;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.745-750
    • /
    • 2009
  • In Korea, since the implementation of the GMO Law, the intrest of biosafety level 3(BL3) lab. is increasing. In this study, using CONTAM which is applying multizone modelling, the multizone simulation for design verification of BL3 lab. was performed. In BL3 lab., because required air change rate is greater than general estimated air-conditioning load and it is difficult to maintain room pressure difference efficiently, to maintain pressure difference between laboratory rooms is important through sealing condition of doors and proper airflow control of laboratory rooms. In this study, about BL3 lab.(M. tuberculosis research lab.), the multizone simulation for four kind of biohazard scenarios was performed in the case of unexpected spread of contaminants in the laboratory room, anteroom, corridor and inside of BSC. Multizone simulation results show that these approach methods are used as a tool for the design and verification of BL3 lab.

  • PDF