• Title/Summary/Keyword: repetition maximum

Search Result 146, Processing Time 0.026 seconds

The penetration characteristic due to the repetition.concentration rainfall in soil cut-slopes (토사절토사면에서 반복 집중강우에 의한 침투특성)

  • Lee, Jeong-Yeob;Koo, Ho-Bon;Rhee, Jong-Hyun;Kim, Seung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.670-675
    • /
    • 2006
  • The purpose of this study is the infiltration characteristics of soil cut-slope by the repetition & concentration rainfall. The maximum rainfall concentrate from June until September which is a rainy season in our country Stability analysis of soil cut-slopes has been conducted by limit equilibrium method on Seep/w and finite element method on Slope/w.

  • PDF

Effect of Deposition Rate on the Property of ZnO Thin Films Deposited by Pulsed Laser Deposition

  • Kim Jae-Won;Kang Hong-Seong;Lee Sang-Yeol
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.98-100
    • /
    • 2006
  • ZnO thin films were deposited at different repetition rates of 5 Hz and 10 Hz by pulsed laser deposition. X-ray diffraction (XRD) full widths at half maximum (FWHMs) of (002) ZnO peak in ZnO thin film deposited at 5 Hz and 10 Hz was 0.22 and $0.26^{\circ}$, respectively. The grain size of ZnO thin film deposited at 5 Hz was larger than that of 10 Hz. The variation of repetition rates did not have an effect on the optical property of ZnO thin films. The degradation of the crystalline quality and surface morphology in ZnO thin film deposited at 10 Hz resulted from supersaturation effect by decrease of time interval between a ZnO particle arriving on a substrate by laser shot and a ZnO particle arriving on a substrate by next laser shot.

Design and evalution of pulsed $CO_2$ laser system using high repetition ratio and high precision (고반복율 및 고정밀방식을 이용한 펄스형 $CO_2$ Laser 시스템 설계 및 평가)

  • 김흥수;김휘영
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.8
    • /
    • pp.1055-1062
    • /
    • 2001
  • Study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 KHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate, gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2$$N_2$:He = 1:3:10, 1:1.5:5, 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average outpu was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2$$N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

A Study on the High Repetition Rate Pulsed $CO_2$ Laser Using IGBT (IGBT를 이용한 고반복 펄스형 $CO_2$ 레이저 개발에 관한 연구)

  • Chung, H.J.;Kim, D.W.;Lee, D.H.;Yoon, S.H.;Lee, Y.S.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1072-1074
    • /
    • 1999
  • In this study, it is the purpose to develope a cheap and compact pulsed $CO_2$ laser with pulse repetition rate range of 1 kHz. We used a IGBT switched power supply as a power supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate gas pressure, and gas mixture rate have been investigated. The experiment was done under the condition of total pressure of $CO_2:N_2$:He = 1.3:10, 1:1.5:5 1:9:15 from 6 Torr to 15 Torr and pulse repetition rate from 100 Hz to 900 Hz. As a result, the maximum average output was about 20.5 W at the total pressure of 15 Torr, the gas mixture $CO_2:N_2$:He = 1:9:15 and the pulse repetition rate of 700 Hz.

  • PDF

A Study on the Development of High Efficieny $CO_2$ Laser : Output Characteristics of Pulsed $CO_2$ Laser Using SMPS Method (고효율 $CO_2$ Laser 개발 연구 : SMPS 방식 펄스형 $CO_2$ Laser의 출력특성)

  • Chung, Hyun-Ju;Lee, Dong-Hoon;Nam, Gyung-Hoon;Kim, Do-Wan;Chung, Young-Hwan;Lee, Yu-Soo;Kim, Hee-Je;Cho, Jung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.730-734
    • /
    • 1999
  • In this study, it is the purpose to develope a cheap and compact repetitively pulsed $CO_2$ laser with pulse repetition rate range of 180 Hz. We used a SCR switched power supply as a high voltage pulsed supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate and gas pressure have been investigated. The experiment was done under the condition of total pressure of $CO_2, N_2$ and He from 4 Torr to 16 Torr and pulse repetition rate from 4 Hz to 180 Hz. As a result, the maximum average output was about 19.6W at the total pressure of 12 Torr and the pulse repetition rate of 180Hz.

  • PDF

Effects of Varied Resistance Training Intensities and Rest Intervals Between Sets on iEMG, Repetition Rate, and Total Work (저항운동의 운동 강도별 세트 간 휴식시간 차이가 근수축력, 반복횟수 및 총운동량에 미치는 영향)

  • Song, Sang-Hyup;Lee, Young-Soo;Han, Aleum;Kim, Si-Young;Go, Sung-Sik
    • 한국체육학회지인문사회과학편
    • /
    • v.51 no.5
    • /
    • pp.639-647
    • /
    • 2012
  • The purpose of this study was to examine the effects of varied resistance training intensities and rest intervals between training sets on integral electromyography (iEMG), repetition rate, and total work. All subjects, 14 college students, were tested one repetition maximum (1RM). Then, all subjects were weekly tested with 9 practice procedures, composed of diverse intensities (60, 75, 90% of 1RM) and rest intervals (1, 3, 5 min). As results show, to maintain the same load and target repetition maximum for an untrained person, muscular power training (90% of 1RM), muscular hypertrophy training (75% of 1RM), and muscular endurance training (60% of 1RM) should be applied with 5 min or longer rest interval periods for 3 training sets. In addition, 2 training sets with 3 min rest intervals and a set with an 1 min rest interval were capable by the subjects. Thus, at least 3 min or longer rest intervals should be applied to maintain multiple training sets. In case for muscular endurance training, which requires shorter rest intervals, the intensity of exercise should be adjusted to 60% of 1RM or less. In conclusion, depending on diverse purposes of resistance training such as improving muscular power, muscular hypertrophy, or muscular endurance, appropriate exercise intensity and rest intervals should be applied.

Development of 4Hz Medical Ruby Laser System with Double Cavities using Multi-Resonant Converter (다중 공진형 컨버터를 이용한 이중 캐비티 구조의 4Hz 의료용 루비레이저 시스템 개발)

  • Lee, Jae-cheol;Zheng, Tao;Shengxu, Piao;Xu, Guo-Cheng;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1207-1211
    • /
    • 2015
  • Various laser systems have been widely used in almost all industrial technologies because they have high energy density, directivity and coherence. Recently the clinical application is becoming wider in medical parts such as incurable disease, diagnosis and so on. Generally, ruby laser beam has the greatest efficacy for removing tattoos, freckle and other skin problem. But current medical ruby laser system has the maximum repetition rate of 2Hz and optical output beam energy of 1J. Many medical doctors really want to have a high repetition ruby laser system because that can reduce the operation time. We investigated a new ruby laser system with high repetition rate of 4Hz using double cavities. Furthermore, we develop a new power supply system adopting zero voltage switching(ZVS) to minimize switching loss by LLC resonant converter designed as 2kW class.

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

Starting Current Application for Magnetic Stimulation

  • Choi, Sun-Seob;Bo, Gak-Hwang;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • A power supply for magnetic-stimulation devices was designed via a control algorithm that involved a start current application based on a resonant converter. In this study, a new power supply for magnetic-stimulation devices was designed by controlling the pulse repetition frequency and pulse width. The power density could be controlled using the start-current-compensation and ZCS (zero-current switching) resonant converter. The results revealed a high-repetition-frequency, high-power magnetic-stimulation device. It was found that the stimulation coil current pulse width and that pulse repetition frequency could be controlled within the range of 200-450 ${\mu}S$ and 200-900 pps, respectively. The magnetic-stimulation device in this study consisted of a stimulation coil device and a power supply system. The maximum power of the stimulation coil from one discharge was 130 W, which was increased to 260 W using an additional reciprocating discharge. The output voltage was kept stable in a sinusoidal waveform regardless of the load fluctuations by forming voltage and current control using a deadbeat controller without increasing the current rating at the starting time. This paper describes this magnetic-stimulation device to which the start current was applied.

The Experimental Study in the Micro Drilling of Excimer Laser on Pyrex Glass (엑시머 레이저를 이용한 파이렉스 유리의 미세 구멍 가공)

  • Lee, Chul-Jae;Kim, Ha-Na;Jeong, Yun-Sang;Jun, Chan-Bong;Park, Young-Chul;Kang, Jung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.99-103
    • /
    • 2012
  • Presently, A glass is widely used in telecommunication system, optoelectronic devices and micro electro mechanical systems. Micro drilling of glass using the laser can save processing cost and improve the accuracy. This paper experiments micro drilling using KrF excimer laser on the pyrex glass of $500{\mu}m$ thickness. We have experiment to find out optimum laser machining conditions of micro drilling of glass and ablation depth and influence by processing parameter suc'h pulse repetition rate, energy density and number of pulses. Pulse repetition rate don't influence ablation depth at the micro drilling of pyrex glass. Energy density influence micro drilling of parallelism and maximum thickness that can be drilled. Ablation depth is most influenced by number of pulses.