• 제목/요약/키워드: repetition maximum

검색결과 146건 처리시간 0.021초

Plasma Display Panel용 산화마그네슘 박막의 산화영역에서의 스퍼터 성막기술 (A sputtering technique of magnesium oxide thin film in oxide mode for plasma display panel)

  • 최영욱;김지현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1874-1875
    • /
    • 2004
  • A high rate deposition sputtering process of magnesium oxide thin film in oxide mode has been developed using a 20 kW unipolar pulsed power supply. The powersupply was operated at a maximum constant voltage of 500 V and a constant current of 40 A. The pulse repetition rate and the duty were changed in the ranges of 10 ${\sim}$ 50 kHz and 10 ${\sim}$ 60 %, respectively. The deposition rate increased with increasing incident power to the target. Maximum incident power to the magnesium target was obtained by the control of frequency, duty and current. The deposition rate of a moving state was 9 nm m/min at the average power of 1.5 kW. This technique is proposed to apply high through-put sputtering system for plasma display panel.

  • PDF

용액내 단분자의 형광소멸시간 계측 (Measurement of fluorecence decay times of single molecules in solution)

  • 고동섭
    • 한국광학회지
    • /
    • 제10권1호
    • /
    • pp.1-4
    • /
    • 1999
  • 공초점 현미경 시스템을 사용하여 반복률이 17MHz이며, 중심파장이 638nm인 극초단 펄스 다이오드 레이저에 의해서 여기된 단분자의 형광폭발신호를 게측하였다. 에칠렌글리콜 용액에 있는 적색 색소 분자(JA22)를 시료로 사용하였다. 시상관 단광자 계수기응 사용하여 단분자들의 현광소멸곡선을 수집하였으며, maximum likelihood estimator로 그것들을 분석하였다. 색소 분자당 40개 이상의 광자수를 가지고 분석하였을 때, 21%의 오차 확률로 형광소멸시간을 계측하는 것이 가능하였다.

  • PDF

산화 마그네슘 박막의 스퍼터 제조기술 (Sputtering technique for magnesium oxide thin films)

  • 최영욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1560-1561
    • /
    • 2006
  • A high rate deposition sputtering process of magnesium oxide thin film in oxide mode has been developed using a 20 kW unipolar pulsed power supply. The power supply was operated at a maximum constant voltage of 500 V and a constant current of 40 A. The pulse repetition rate and the duty were changed in the ranges of $10{\sim}50\;kHz$ and $10{\sim}60%$, respectively. The deposition rate increased with rising incident power to the target. Maximum incident power to the magnesium target was obtained by the control of frequency, duty and current. The deposition rate of a moving state was 9 nm m/min at the average power of 1.5 kW.

  • PDF

Effect of Wrist Resistance Training on Motor Control and Strength in Young Males

  • Kim, You-Sin;Kim, Dae-Hoon
    • 한국운동역학회지
    • /
    • 제24권3호
    • /
    • pp.309-315
    • /
    • 2014
  • The aim of the present study was to investigate the effects of 6-week wrist resistance training on wrist torque control. Nineteen subjects were randomly assigned to either the wrist training group (n=9) or the control group (n=10). The training group performed wrist exercises for six directions (flexion, extension, pronation, supination, radial deviation, and ulnar deviation) while the control group did not. Testing for the isometric torque control error, one-repetition maximum (1-RM) strength, and isokinetic maximum torque (angular velocity of $60^{\circ}/s$ wrist movements) were conducted before and after six weeks of resistance training and after every two-week interval of training. The wrist training group showed significant decreases in isometric torque control error in all six directions after the 2-week resistance training, while the control group did not show significant increase or decrease. The training group showed significant increases in the maximum strength in all six directions assessed by 1-RM strength and isokinetic strength tests after the 4-week resistance training, while the control group did not show any statistically significant changes. This study shows that motor control ability significantly improves within the first two weeks of resistance training, while the wrist strength significantly improves within the first four weeks of resistance training in wrist training group compared to the control.

Maximum Likelihood-based Automatic Lexicon Generation for AI Assistant-based Interaction with Mobile Devices

  • Lee, Donghyun;Park, Jae-Hyun;Kim, Kwang-Ho;Park, Jeong-Sik;Kim, Ji-Hwan;Jang, Gil-Jin;Park, Unsang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권9호
    • /
    • pp.4264-4279
    • /
    • 2017
  • In this paper, maximum likelihood-based automatic lexicon generation using mixed-syllables is proposed for unlimited vocabulary voice interface for East Asian languages (e.g. Korean, Chinese and Japanese) in AI-assistant based interaction with mobile devices. The conventional lexicon has two inevitable problems: 1) a tedious repetition of out-of-lexicon unit additions to the lexicon, and 2) the propagation of errors during a morpheme analysis and space segmentation. The proposed method provides an automatic framework to solve the above problems. The proposed method produces a level of overall accuracy similar to one of previous methods in the presence of one out-of-lexicon word in a sentence, but the proposed method provides superior results with the absolute improvements of 1.62%, 5.58%, and 10.09% in terms of word accuracy when the number of out-of-lexicon words in a sentence was two, three and four, respectively.

사이클링 초최대운동(Supra maximal training)시 RPM과 족관절의 운동학적 분석 (Kinematic characteristics of the ankle joint and RPM during the supra maximal training in cycling)

  • 이용우
    • 한국운동역학회지
    • /
    • 제15권4호
    • /
    • pp.75-83
    • /
    • 2005
  • The purpose of this study was to determine the kinematic characteristics of the ankle joint and RPM(repetition per minutes) during the supra maximal training in cycling. For this study, 8 national representative cyclists, distance cyclists in track and road, were selected. During the super-maximum pedalling, kinematic data were collected using a six-camera(240Hz) Qualisys system. the room coordinate system was right-handed and fixed in the back of a roller for cycle, with right-handed orthogonal segment coordinate systems defined for the leg and foot. Lateral kinematic data were recorded at least for 3 minutes while the participants pedal on a roller. Two-dimensional Cartesian coordinates for each marker were determined at the time of recording using a nonlinear transformation technique. Coordinate data were low-pass filtered using a fourth-order Butterworth recursive filter with cutoff frequency of 15Hz. Variables analyzed in this study were compared using a one factor(time) ANOVA with repeated measures. The results of investigation suggest that the number of rotating pedal was decreased with time phase during the super-maximum pedaling. Maximum angle of the ankle joint showed little in change with time phase compared with minimum angle of that.

최대 근력과 관련하여 EMG 상관관계에 관한 기초 연구 (A Basic Correlational Study of the Relationship between Maximum Muscle Power and EMG)

  • 이성복;김동준;김경호
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1815-1820
    • /
    • 2017
  • In this paper, a study was conducted to estimate the maximum muscle strength which is a standard for selecting exercise intensity in weight training. We designed a device that estimates the muscle fatigue from the EMG signal, expecting to show a correlation between peak muscle strength and fatigue. Curl - Dumbbell was performed using a 4 kg dumbbell and the frequency change of the EMG was observed. At this time, the designed device acquires the signal using the MCU and finally Matlab was used to confirm the change in the center frequency value. The results of 10 subjects were analyzed using SPSS regression analysis. The statistical results showed a correlation of $R^2$ 0.583 and Significant probability of 0.010, and the relation of Y = 8.144-2.097 (slope (MDF)) was obtained. In conclusion, if the wearable device is manufactured in the form of a wearable device and the user can recommend the exercise intensity, the system will be able to retry the more efficient exercise.

고전압 Nano-second펄스 전자총에 관한 연구 (Study on HV Nano-second Pulse Electron Gun System)

  • 손윤규;박성주;장성덕;오종석;조무현;남궁원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1391-1393
    • /
    • 1995
  • An electron gun system for the Pohang Light Source has been installed and operated successfully. The basic design parameters are acceleration voltage of 80 kV, maximum peak emission current of 5 A, minimum pulse width of 1 ns, and maximum repetition rate of 100 Hz. The gun has a triode structure and is composed of a cathode, a focusing electrode(Wehnelt), and an anode. To sustain a $5{\times}10^{-9}$Torr vacuum, a $230{\ell}/s$ Ion pump has been adopted. We adopted a control and monitoring system based on the fiber-optic technology. In this article, we present the structure and operation principle of the system with special interest on the nanosecond pulser, remote control and monitoring system.

  • PDF

Effects of Different Cool-down Exercise Methods on Muscle Strength and Endurance of the Lower Extremities

  • Bae, Chang-Hwan;Cho, Sung-Hyoun;HwangBo, Gak
    • International Journal of Contents
    • /
    • 제8권2호
    • /
    • pp.97-102
    • /
    • 2012
  • The purpose of this study was to investigate the effects of various cool-down exercises on muscular strength and endurance. After receiving a treadmill training for main exercise, the subjects conducted isotonic and isometric cool-down exercises four times for three weeks. Isotonic exercise with leg press of 10kg was repeated by 20 times and isometric exercise was conducted at flexion of hip joint and knee joint with leg press of 10kg by maintaining it for 6 sec and resting for 2 sec by 20 times. Muscular strength after exercise was measured with 1 RM by times and muscular endurance with maximum repetition frequency using time to keep for loading the weight of 10 RM and 65% of maximum muscular strength. As a result of comparing and analyzing measured values, exercise recovery shape of isotonic and isometric cool-down group were more effective than rest recovery shape of the control group. The isometric cool-down group was more effective than isotonic cool-down group. In conclusion, isometric exercise was more effective than isotonic exercise or simple rest on muscular strength and endurance.

조석현상이 방조제 경계면의 응력-변형 거동에 미치는 영향 분석 (The Analysis of Tidal Effect on Stress-Strain Behavior in the Boundary Surface of Sea Dike Embankment)

  • 임성훈
    • 한국농공학회논문집
    • /
    • 제55권2호
    • /
    • pp.1-8
    • /
    • 2013
  • This study was performed for the purpose of analyzing the effect of tide on the stress-strain behavior in the boundary surface of sea dike embankment. Tide is a dynamic condition, but there are not suitable numerical models to solve the dynamic embankment condition caused by tide. So the analysis was simplified to quasi dynamic as follow. First, seepage by tide was analyzed according to elapsed time, and the results of the analysis at every hour during one periodic cycle time of 12 hours were applied to the pore water pressure conditions of stress-strain analysis with hyperbolic model by Duncan and Chang. The place at which maximum shear strain took place in the analysis result moved up and down repeatedly along the boundary of the dredged sand fill section and the crashed stone filter section. The value of maximum shear strain was large at high water level of tide. This result means that contraction and relaxation occur in turn repeatedly at every specific position along the boundary, and the repeated action compact loose position with sand moved down from the upper position by gravity. The experiment with the small sea dike model showed the result consistent with the numerical analysis. The surface of sea side on the dike collapsed at high water level after a couple of repetition of the rising and falling of water.