• Title/Summary/Keyword: repeated measurements

Search Result 439, Processing Time 0.027 seconds

The Stereomicroscope and SPM Study on the Marginal Change of Porcelain Crown in Various Repeated Instrumentations for Periodontal Therapy (치주처치를 위한 기구의 반복 사용시 도재관 변연부 변화에 관한 입체 및 주사탐침현미경적 연구)

  • Lee, Si-Cheol;Chung, Chin-Hyung;Yim, Seong-Bin
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.455-472
    • /
    • 2000
  • Instrumentation for periodontal therapy may induce marginal damage which increases plaque accumulation and result in periodontal disease. But there have not been many reports of instrumentations on the artificial crown so far. Therefore this study is conducted to evaluate the effects of various repeated instrumentations on the porcelain crown marginal portion. Of the 10 extracted periodontally diseased maxillary first premolars, were 12 proximal surface used in this study. The finishing line of the preparation was placed on the root surface below CEJ and then the crown was cast and cemented in usual manner. Every 4 surfaces of the 3 instruments-curet, ultrasonic scaler, and ultrasonic curet- is used. and four samples used in each instruments. The relevant procedures and measurements were repeated 3 times in each surfaces. Marginal gap is measured by the microscope and surface roughness, Scannig Probe Microscope. Measurements are made at 5 points in each surfaces, making 20 points in each instrument. The results evaluated statistically were as follows 1. As instrumentation was repeated, both marginal gap and roughness were increased in all group 2. In the hand curet, marginal gap was increased every instrumentation and roughness was increased after second. 3. In the ultrasonic scaler, both marginal gap and roughness were increased every instrumentation. 4. In the ultrasonic curet, marginal gap was increased after third instrumentation and roughness was increased after second. 5. Marginal gap and roughness used by the ultrasonic curet were lower than the others and no difference was seen between the hand curet and ultrasonic scaler From the results of this study, the ultrasonic curet was useful in some aspect, but careful instrumentation was needed. Furthermore it was important to minimize the instrumentation through complete periodontal therapy before setting and adequate plaque control.

  • PDF

Effects of Different Intensities of Repeated Hypoxic Stress on Immune Functions in Mice (마우스에서 반복적 저산소 스트레스 정도에 따른 면역동성 효과)

  • 강동원;김건태;김동구
    • Toxicological Research
    • /
    • v.15 no.1
    • /
    • pp.27-34
    • /
    • 1999
  • To study the nature of differentially manifested adaptive response of an organism according to the intensities of the stress, the immune effects of different levels of repeated hypoxia were investigated. Four experimental groups (NH : not -handled, 20% : handled, 15% or 10% : exposed to 15% or 10% $\textrm{O}_2$ 씨오투 with balanced nitrogen, respectively) of mice were exposed to different levels of hypoxia for 60 min/day, 5days/week in a repeated and intermittent manner. After 8 weeks' exposure to hypoxia environment, mice were subjected to immune function measurements, A decreased proportion of CD3+ CD8 phenotype cells in the study of splenocyte subsets was observed in the 10% group. Ovalbumin-stimulated IgG2a production was increased in the 15% group, while no changes were noted in the IgGl and IgM production. No significant changes of the antigen-stimulated splenocyte proliferation and the natural killer cell cytotoxicity were found. These results show that the stress effects on the immune systems can be varied according to the strength of the stress and that a mild level of repeated hypoxic stress can enhance the immune function of mice in this experimental model.

  • PDF

가우스의 오차론에 근거한 정규분포 배경의 역사적 고찰

  • 구자흥
    • Journal for History of Mathematics
    • /
    • v.12 no.1
    • /
    • pp.1-12
    • /
    • 1999
  • The first part of this thesis discusses the types and the properties of errors, one of which makes up systematic errors of measurements, removable by detecting their causes, the other errors of accidental causes which can not be removed. The final part of this thesis deals with the historical background of the Gaussian distribution by Hershel, Hagen, Laplace and Gauss from the late 18th century to the early 19th century. It can be concluded that the accidental idea and the treatment of accidental error distribution by Gauss Is the best one based on the assumption that the most probable value of true value is the arithmetic mean of data, obtained by repeated measurements of a given quantity.

  • PDF

Study on an Electrode Attachment Method Suitable for Underwater Electromyography Measurements

  • Han, Seul-ki;Park, Jung-seo;Nam, Taek-gil
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.95-98
    • /
    • 2015
  • PURPOSE: This study was conducted to devise a method of preventing water infiltration into the surface electrodes during EMG measurements underwater and on the ground and to check the reliability of Electromyography (EMG) measurements when underwater. METHODS: Six healthy adults were selected as subjects in this study. The measurements in this study were conducted in pool dedicated to underwater exercise and physical therapy room in the hospital building. An MP150 (Biopac Systems, US, 2010) and a BioNomadix 2-channel wireless EMG transmitter (Biopac Systems, US, 2012) was used to examine the muscle activity of rectus femoris, biceps femoris, tibialis anterior, gastrocnemius of dominant side. The subjects repeated circulation tasks on the ground for more than 10 min for enough surface electrode attachment movement. After a 15-min break, subjects performed the circulation task underwater(water depth 1.1m, water temperature $33.5^{\circ}C$, air temperature $27^{\circ}C$), as on the ground, for more than 10 min, and the MVIC of each muscle was measured again. SPSS v20.0 was used for all statistical computations. RESULTS: The maximum voluntary isometric contraction (MVIC) values between the underwater and on the ground measurements showed no significant differences in all four muscles and showed a high intraclass correlation coefficient (ICC) of >0.80. CONCLUSION: We determined that EMG measurements obtained underwater could be used with high reliability, comparable to ground measurements.

A Reliability Study of Tape and Photography Measurement Techniques for Scapular Position (줄자 및 사진촬영 측정을 이용한 어깨뼈 벌림 측정에 대한 신뢰도 연구)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Ha, Sung-Min
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.74-80
    • /
    • 2013
  • The purpose of this study was to determine the reliability of distance measurements from the medial border of the scapula to the spinous process of the thoracic vertebrae when obtained using tape and photography measurements. The study included 20 healthy subjects (10 males, 10 females); for a total of 40 scapula measurements. The distance measurements made using tape or photography methods were conducted with the subject in a standing position. Repeated tape and photography measurements were conducted in two sessions on different days by two examiners to assess the inter-rater and intra-rater reliability of the two methods. The reliability of scapular distance measured using tape and photography methods was tested using intraclass correlation coefficients (ICC(3,1)) and the standard error of measurement (SEM). The inter-rater reliability of the tape measurement method was excellent (ICC=.77) and the intra-rater reliability was fair to good (ICC=.74). The inter-rater and intra-rater reliabilities of the photography measurement method were excellent (ICC=.76 and .76 respectively). Our results suggest that photography measurement is an objective and qualitative measurement tool for scapular distance measurements.

Linear Trend Comparison of Repeated Measures Data among Treatments with a Control (반복측정 자료에서 개제기올기를 이용한 대존군과 처리군들의 선형추세 검정법)

  • Kwon, Jae-Hoon;Kim, Dong-Jae
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.6
    • /
    • pp.945-957
    • /
    • 2009
  • Repeated measurement data among several treatments with a control is often used in the field of medicine study. In this paper, we suggest a method for comparison of the linear trend of responds followed time among several treatments with a control based on repeated measurement data. First, we estimate slope from each subject and generate samples using the slope estimated previous. And then, we test the difference among treatment with a control by ANOVA F test, Jonckheere-Terpstra test, updated control group procedure using generated samples. Monte Carlo Simulation is adapted to compare the power and experimental significance levels in various configuration.

Comparison of the Balancing Capacity and Strength of Taping for the Knee Joint and Repeated Measurements (무릎관절 멀리건 테이핑이 균형능력과 각근력에 미치는 효과와 측정의 반복에 의한 효과 비교)

  • Park, Bo-hyun;Choi, Su-hong;Kim, Sung-joong;Park, Su-hyung;Oh, Kang-o
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2018
  • Background: The purpose of this study was to compare the effects of mulligan taping on knee joints on balance ability and strength with repeated measurements. Methods: Seventeen patients were randomly assigned to the 8 taping group and the 9 repeat measurement group. To measure the balance ability, fall risk assessment equipment was used, and the measurement of the muscle strength was performed by using the equipment of the same company. Results: Balanced abilities and muscle strength were increased in groups with taping only after Mulligan taping. Conclusions: The application of mulligan taping did not have the effect of stimulating the inherent receptive sensation. However, active grouping of the knee joint taping only, and muscle strength and muscle strength were increased. It increases the stability and activity of the muscles that operate on the balance of the active knee joint and muscle strength, thereby enhancing exercise prevention and prevention performance and exercise performance.

Reliability of External Ear Measurements Obtained by Direct, Photocopier Scanning and Photo Anthropometry

  • Liu, Bor-Shong;Tseng, Hsien-Yu;Chia, Tung-Chung
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.1
    • /
    • pp.20-27
    • /
    • 2010
  • The purpose of this study was to compare the consistency of external ear measurements obtained by electronic digital caliper, photocopier scanning and digital photographic methods. Photogrammetric measurements were made after image editing software was used to optimize the brightness, contrast, size and image clarity. The CorelDRAW dimension tool was used to create a dimension line that measured the vertical and horizontal length between any two landmarks. Results of repeated measures analysis of variance revealed no significant differences in length and width of the pinna between the three methods. The reliability of the three measurement techniques showed a high degree of consistency. Further study and efforts could be extended to measurement hands, foots and facial dimensions by present techniques.

A Logit Model for Repeated Binary Response Data (반복측정의 이가반응 자료에 대한 로짓 모형)

  • Choi, Jae-Sung
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.2
    • /
    • pp.291-299
    • /
    • 2008
  • This paper discusses model building for repeated binary response data with different time-dependent covariates each occasion. Since repeated measurements data are having correlated structure, weighed least squares(WLS) methodology is applied. Repeated measures designs are usually having different sizes of experimental units like split-plot designs. However repeated measures designs differ from split-plot designs in that the levels of one or more factors cannot be randomly assigned to one or more of the sizes of experimental units in the experiment. In this case, the levels of time cannot be assigned at random to the time intervals. Because of this nonrandom assignment, the errors corresponding to the respective experimental units may have a covariance matrix. So, the estimates of effects included in a suggested logit model are obtained by using covariance structures.

ERRORS IN DIGITIZED LATERAL CEPHALOMETRIC RADIOGRAPHY (계수 영상화된 측모 두부방사선 규격사진의 계측오차)

  • Jean Seon-Doo;Cho Bong-Hae;Nah Kunng-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.105-116
    • /
    • 1997
  • The purpose of this study is to evaluate the cephalometric reproducibility in digitized cephalometric radiography by comparing the measurement errors between the remeasured and retaken conventional and digitized lateral cephalometric radiography. The mean of the differences and error percentage of each cephalometric measurement were obtained using 96 lateral cephalometric radiography from 48 patients between the age of 11 and 13. The results were as follows; 1. The repeated measurement group of conventional radiography showed least amount of mean differences while those of the retaken measurement group of digitized image showed largest amount of mean differences in every measurement. 2. The measurements which showed statistically significant difference between the conventional radiography and digitized image were S-Go, Ar-Go, S-Ar-Go and S-sN-sNT in repeated measurement group. 3. The measurements which showed statistically significant difference between the repeated and retaken measurement groups were N-S-Ar, MP-Ll and S-sN-sPog in conventional radiography and S-N, Go-Me and N-A in digitized Image. 4. Large amount of error percentage was shown at A-N-B and N-A in retaken measurement group of conventional radiography and N-S-Ba and A-N-B in retaken measurement group of digitized image. 5. The amount of error percentage at Ar-Go and N-S- Ar in retaken measurement group of conventional radiography and S-N, N-A, S-N-B and N-S-Ba in retaken measurement group of digitized image was more than double than those from remeasured groups.

  • PDF