• 제목/요약/키워드: removal of Fe

검색결과 711건 처리시간 0.031초

컬럼실험을 통한 Fe-loaded zeolite의 Cd& Cr(VI) 동시제거 반응성 평가 (Simultaneous Removal of Cd &Cr(VI) by Fe-loaded zeolite in Column System)

  • 이아라;이승학;박준범
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.151-154
    • /
    • 2005
  • Laboratory column experiments for simultaneous removal of Cd and Cr(VI) are conducted using newly developed material, referred to as Fe-loaded zeolite, which has both reduction ability of iron and ion exchange ability of zeolite. Breakthrough curves were obtained from each column experiment, and described with advection-dispersion equation. Apparent parameters including $K_{app}\;and\;D_{app}$ were newly introduced for effectively describing the Cr(VI) breakthrough curve. $K_{app}$ decreased with increasing initial contaminant concentration and with decreasing flow rates. Whereas, $D_{app}$ were not significantly affected by initial contaminant concentration or flow rate.

  • PDF

Alamine 336을 이용한 염화네오디뮴 수용액으로부터 Fe 제거 (Iron Removal from Neodymium Chloride Solution with Alamine 336)

  • 엄형춘;이진영;김철주;손정수;윤호성
    • Korean Chemical Engineering Research
    • /
    • 제46권3호
    • /
    • pp.512-515
    • /
    • 2008
  • 본 연구는 염화네오디뮴 수용액으로부터 Fe 성분 제거를 위하여 Alamine 336을 이용한 Fe의 용매추출을 수행함에 있어서, Alamine 336의 농도, 염산 및 염소이온 농도에 따른 Fe 추출 특성 및 유기상으로 추출된 Fe의 탈거공정에 있어 상비와 탈거 용액의 염산 농도의 영향들을 고찰하였다. Alamine 336을 사용하여 Nd, Fe 혼합 용액으로부터 Fe 만을 선택적으로 추출할 수 있다는 것을 확인하였으며, 수상의 염산 및 염소이온 농도 증가에 의해 Fe의 추출율이 증가하였다. Fe가 추출된 Alamine 336을 증류수로 탈거할 경우 A/O비 4인 조건에서 99%의 Fe를 탈거할 수 있었으며, 탈거 용액의 염산 농도가 증가할수록 Fe 탈거율이 감소하였다.

Fe-Mn-Si 산화물을 이용한 인제거 흡착연구 (Phosphate removal using novel combined Fe-Mn-Si oxide adsorbent)

  • 맹민수;이해균;독고석
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.631-639
    • /
    • 2013
  • 국내 하수처리장 인 방류기준이 강화되어 다양한 방법의 인 제거기술이 적용되고 있다. 흡착은 비교적 간단하면서 효과적으로 인을 제거할 수 있다. 본 연구에서는 흡착제인 Fe-Mn-Si oxide와 Fe-Mn oxide을 개발하여, 인 제거효율을 검토하였으며 이 흡착제에 대하여 Kinetic과 Isotherm모델을 비교하였다. 두 흡착제의 최대흡착양은 각각 47.8, 35.5 mg-$PO{_4}^{3-}/g$이었고, 이들은 낮은 pH에서 효과적으로 흡착하였다. Freundlish isotherm 모델이 Langmuir 모델보다 Fe-Mn-Si oxide의 흡착에 더 적합했다. 이온성 용액은 인이 흡착되는 과정에서 음이온들과 경쟁관계로 흡착능이 감소되었다. 비록 음이온과 humic물질들로부터 흡착에 영향을 받지만 Fe-Mn-Si oxide는 Fe-Mn oxide보다 흡착능이 크게 나타났다.

A highly effective route for removal of Hg2+ from the waste water using 3-nitrobenzelidenemalononitrile as a modifier of Fe3O4@SiO2 nanoparticles

  • Mosleh Mehryar;Ghasem Marandi
    • Advances in nano research
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2024
  • SiO2-coated magnetic nanoparticles (Fe3O4@SiO2 NPs) were modified by 3-nitrobenzelidenmalononitrile and used as green linkages for removal of Hg2+ form the wastewater. In this research, it has been attempted to refer to the harmful effects of mercury ions for living things and how to remove such ions using very easy and practical technique. This study shows that by optimizing the test conditions, the efficiency of the removal of harmful ions such as mercury from the water contaminated with these ions can be increased. Conditions such as temperature, speed of agitation, pH of solution were tested for removal of mercury ions. The advantages of this method over other methods listed in the article are the rapid and easy nanocry synthesis. The generated and modified Fe3O4@SiO2 nanoparticles were characterized by X-ray diffraction, fourier transform infrared and scanning electron microscopy spectroscopy. The results show that the synthesized magnetic nanoparticles have the excellent performance for the removal of mercury(II) ion from the waste water.

Removal characteristics of organic matter during pretreatment for membrane-based food processing wastewater reclamation

  • Jang, Haenam;Lee, Wontae
    • Membrane and Water Treatment
    • /
    • 제9권4호
    • /
    • pp.205-210
    • /
    • 2018
  • In this study, we investigated coagulants such as polyaluminum chloride (PACl) and ferric chloride ($FeCl_3$) and the combination of a coagulant and powdered activated carbon (PAC) for the removal of dissolved organic matter (DOM) from fish processing effluent to reduce membrane fouling in microfiltration. The efficiency of each pretreatment was investigated through analyses of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$). Membrane flux and silt density index (SDI) analyses were performed to evaluate membrane fouling; molecular weight distributions (MWD) and fluorescence excitation-emission matrix (FEEM) spectroscopy were analyzed to assess DOM characteristics. The results demonstrated that $FeCl_3$ exhibited higher DOC and $UVA_{254}$ removals than PACl for food processing effluent and a combination of $FeCl_3$ and PAC provided comparatively better results than simple $FeCl_3$ coagulation for the removal of DOM from fish processing effluent. This study suggests that membrane fouling could be minimized by proper pretreatment of food processing effluent using a combination of coagulation ($FeCl_3$) and adsorption (PAC). Analyses of MWD and FEEM revealed that the combination of $FeCl_3$ and PAC was more efficient at removing hydrophobic and small-sized DOM.

The Importance of Reaction Mechanisms in Interpreting the Arsenic Reactive Transport of FeS-coated Sand Column

  • Han, Young-Soo;Demond, Avery H.;Hayes, Kim F.
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제20권5호
    • /
    • pp.1-10
    • /
    • 2015
  • FeS, as a natural reduced iron mineral, has been recognized to be a viable reactive material for As(III) sequestration in natural and engineered systems. In this study, FeS-coated sand packed columns were tested to evaluate the As(III) removal capacities under anaerobic conditions at pH 5, 7 and 9. The column obtained As(III) removal capacity was then compared with the capacity result obtained from batch reactors. In the comparison, two different approaches were used. The first approach was used the total As(III) removal capacity which method was proved to be useful for interpreting pH 5 system. The second approach was used to consider sorption non-linearity and proved to be useful for interpreting the pH 9. The results demonstrated that a mechanistic understanding of the different removal processes at different pH conditions is important to interpret the column experimental results. At pH 5, where the precipitation of arsenic sulfide plays the major role in the removal of arsenic, the column shows a greater removal efficiency than the batch system due to the continuous dissolution of sulfide and precipitation of arsenic sulfide. At pH 9, where adsorption mainly governs the arsenic removal, the sorption nonlinearity should be considered in the estimation of the column capacity. This study highlighted the importance of understanding reaction mechanism to predict column performance using batch-obtained experimental results.

Enhancement of Methylene Blue dye adsorption by Fe-Hydroxyapatite composite

  • Cifci, Deniz Izlen
    • Advances in environmental research
    • /
    • 제5권4호
    • /
    • pp.225-235
    • /
    • 2016
  • Synthesized hydroxyapatite (Hyd) and Fe-hydroxyapatite (Fe-Hyd) composite were used for the removal of Methylene Blue (MB) from aqueous solutions in this study. The effect of adsorbent amount, pH and initial MB concentration were carried out to investigate in the aqueous solution. The kinetic study shows that the MB adsorption process with Hyd or Fe-Hyd follow pseudo-second order kinetic model. Experimental results are well fitted to the Langmuir isotherm model. The maximum adsorption capacities of Hyd and Fe-Hyd were obtained as 2.90 mg/g and 5.64 mg/g for MB according to Langmuir Isotherm models, respectively. Fe-Hyd composite increased the adsorption capacity of Hyd by 1.95 times that Hyd. It is concluded that Fe-Hyd composite is promising and economical adsorbent for MB removal in the aqueous solution.

철 접촉재를 이용한 간헐폭기식 활성슬러지 공법에 의한 인의 제거 (Removal Phosphorus Using Iron Contactor by Intermittent Aeration Activated Sludge Process)

  • 이영신;김동민
    • 한국환경보건학회지
    • /
    • 제19권4호
    • /
    • pp.33-37
    • /
    • 1993
  • The problem for the removal of phosphorus increased due to reasons like eutrophication control. However its removal and operating criteria were not well developed. This study was made for enhanced removal of P by iron contactor by intermittent aeration activated sludge process. Experiment was conducted to find the effects of organic substance load and HRT, nutrient removal efficiency. When applied organic substance load and HRT, II &III reactor were good treatment efficient while come from Fe of iron contactor. Release of phophorus from II &III reactor sludge under anaerobic condition was low. As the process developed, the content of released ionized Fe from iron contactor increased. In addition, the rate of phosphorus removal became accelerating, and the removed sludge was stabilized in the existence of insoluble status.

  • PDF

Synthesis of magnetite iron pumice composite for heterogeneous Fenton-like oxidation of dyes

  • Cifci, Deniz Izlen;Meric, Sureyya
    • Advances in environmental research
    • /
    • 제9권3호
    • /
    • pp.161-173
    • /
    • 2020
  • The removal of two dyes, namely Methylene Blue (MB) and Reactive Brillant Red (RR) from aqueous solution was investigated using magnetite iron coated pumice (MIP) composite in the Fenton-like oxidation process. A weight ratio of 2.5 g (with the molar ratio of Fe3+ to Fe2+ to be 2) (5%) of iron to the total pumice (50 g) was enabled during synthesis of catalyst. Surface composition and characteristics of the catalyst were assessed by SEM-EDX, FT-IR, Raman spectral analysis. The effect of the amount of pumice solely used or MIP, H2O2 concentration, pH and initial concentration of MB or RR dyes on Fenton-like process efficiency was investigated. EDAX spectrums of pumice and MIP showed that oxygen and silisium are the major elements. The Fe content of MIP increased to 2.24%. SEM, FT-IR and Raman spectrums confirmed the impregnation of Fe on pumice surface. The experimental results revealed that high removal rates of dyes could be obtained using MIP that demonstrated a higher stability for removal of MB dye. pH affected the removal efficiency of both dyes and the degradation of both dyes was sharply dropped when pH was increased above 4. The removal of dyes did not significantly change with increasing H2O2 concentration. Degradation rates of both MB and RR dyes increased 3.3 and 2.8 times with the use of MIP compared to pumice alone, respectively. Furthermore, MIP enabled a good removal efficiency at higher dye concentrations. It can be emphasized that MIP composite can be used in the heterogeneous Fenton-like systems considering the economic and easily separation aspects.

펜톤산화에 따른 복합폐수의 처리효율연구 (Treatment Efficiency of Complex Wastewater by Fenton's Oxidation Condition)

  • 성일화
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.446-450
    • /
    • 2006
  • In order to treat the wastewater containing organic compound, pre-treatment system connected with MSP(molecular separation process) was investigated. With the aim of selecting an optimum process of Fenton's oxidation, removal efficiency of each process in the optimum reaction condition was recommended. The $Fe/H_{2}O_{2}$(ferric sulfate to hydrogen peroxide)reagent is referred to as the Fenton's regent, which produces hydroxyl radicals by the interaction of Fe with $H_{2}O_{2}$. The powerful oxidizing ability and extreme kinetic reactively of the hydroxyl radical was well established. Increasing dosage of $Fe/H_{2}O_{2}$ increased removal efficiency as molar ratio of $Fe/H_{2}O_{2}$ between 0.2 and 2.5. Optimum dosage of molar ratio was 1. The removal efficiency for reaction condition was increased as pH decreased when the molar ratio of $Fe/H_{2}O_{2}$ was 1.7. Fenton's oxidation was most efficient in the reaction time 35 min for complex wastewater. Also, coagulation aid experiments using kaolin resulted in 3% of kaolin dosage.