• 제목/요약/키워드: removal efficiency for nitrate

검색결과 124건 처리시간 0.026초

Nitrate Removal in a Packed Bed Reactor Using Volatile Fatty Acids from Anaerobic Acidogenesis of Food Wastes

  • Lim, Seong-Jin;Ahn, Yeong-Hee;Kim, Eun-Young;Chang, Ho-Nam
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권6호
    • /
    • pp.538-543
    • /
    • 2006
  • A packed bed reactor (PBR) was fed with nitrate containing synthetic wastewater or effluent from a sequencing batch reactor used for nitrification. The C source introduced into the PBR consisted of volatile fatty acids (VFAs) produced from anaerobic acidogenesis of food wastes. When nitrate loading rates ranged from $0.50\;to\;1.01\;kg\;N/m^{3}{\cdot}d$, the PBR exhibited $100{\sim}98.8%\;NO_{3}^{-}-N$ removal efficiencies and nitrite concentrations in the effluent ranged from $0\;to\;0.6\;NO_{2}^{-}-N\;mg/L$. When the PBR was further investigated to determine nitrate removal activity along the bed height using a nitrate loading rate less than $1.01\;kg\;N/m^{3}{\cdot}d$, 100% nitrate removal efficiency was observed. Approximately 83.2% nitrate removal efficiency was observed in the lower 50% of the packed-bed height. When reactor performance at a C/N ratio of 4 and a C/N ratio of 5 was compared, the PBR showed better removal efficiency (96.5%) of nitrate and less nitrite concentration in the effluent at the C/N ratio of 5. VFAs were found to be a good alternative to methanol as a carbon source for denitrification of a municipal wastewater containing 40 mg-N/L.

Remediation Groundwater contaminated with Nitrate and Phosphate using Micellar-enhanced ultrafiltration

  • 백기태;양지원
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.334-337
    • /
    • 2002
  • The drinking water industry faces a growing number of difficultiesin the treatment of groundwater for drinking water production. Groundwater sources are frequently contaminated with nitrates and phosphates due to usage of chemical fertilizer In this study, feasibility of micellar enhanced ultrafiltation (MEUF) was investigated to remediate groundwater contaminated with nitrate and phosphate. Ultrafiltration membrane was cellulose acetate with molecular weight cut off (MWCO) 10,000 and celtyl pyridinium chloride (CPC) was used to form pollutant-micelle complex with nitrate and phosphate. The results show that nitrate and phosphate rejections are satisfactory. The removal efficiency of nitrate and phosphate show 80% and 84% in single pollutant system, respectively with 3 molar ratio of CPC to pollutants. In the multi-pollutant systems, the removalefficiency increased to 90 % and 89 % for nitrate and phosphate, respectively, The presence of nitrate in the solutions did not affect the removal of phosphate and that of phosphate did not affect the removal of nitrate. The concentration of CPC in the permeate and removal efficiency of CPC was a function of the concentration of CPC in the feed solutions.

  • PDF

Study on Simultaneous Removal of Nitrogen and Phosphorus Using Zeocarbon

  • Hong, Ji-Sook;Suh, Jeong-Kwon
    • Carbon letters
    • /
    • 제11권2호
    • /
    • pp.112-116
    • /
    • 2010
  • The objective of this study was to evaluate the possibility of simultaneous removal of ammonium, nitrate and phosphorus in water using the zeocarbon. In this study, the surface of zeocarbon was modified by acid because of difficulty in application of water treatment. After surface modification, the strength was enhanced about 62% higher than that of original one. The removal efficiency of ammonium and nitrate using the modified zeocarbon was about 47% and 32%, respectively and were higher than that of zeocarbon. In batch type experiment on the simultaneous removal of ammonium, nitrate and phosphorus, the presence of phosphorus did not have influence on nitrogen removal efficiency. Concomitantly, removal efficiency of phosphorus was obtained was about 35%. This indicates that the surface modified zeocarbon can be applied for simultaneous removal of nitrogen and phosphorus. Consequently, our results could be used as basic data to design of one-stage nitrogen/phosphorus simultaneous removal system.

염화철 처리 활성탄에 의한 질산염 제거 (Nitrate Removal by $FeCl_3$-Treated Activated Carbon)

  • 정경훈;최형일;정오진
    • 한국환경보건학회지
    • /
    • 제27권1호
    • /
    • pp.63-68
    • /
    • 2001
  • A laboratory experiment was performed to invstigate the nitrate removal using FeCl$_3$ -treated activated carbon. Iron chloride(III) was coated onto the surface of activated carbon. The removal efficiency of nitrate was increased with increasing of FeCl$_3$ was used for coating material. About 22~26mg of Fe per unit g of activated carbon was adsorbed. The nitrate removal was not affected by the pH under the experiment range of pH, but the pH value in solution decrease to 3.5~4.0 after reaction. The removal efficiency of nitrate was increased with increasing of dosage of adsorbents. Ammonia was not detected and the Fe concentration as low as 0.22mg/$\ell$ was desorbed from the adsorbents. The adsorbents was regenerated using KCl solution, and recovery was 76.6% at 1 M of KCl. The adsorption of nitrate by FeCl$_3$-treated activated carbon followed the Freundlich isotherm equation and the Freundlich constant, 1/n, was 0.346. These results showed that the FeCl$_3$-treated activated carbon could serve as the basis of a useful nitrate removal.

  • PDF

Process Development for Effective Denitrification by Biofilter Using Loess Ball

  • CHOI DU BOK;LEE DONG BYUNG;CHA WOL SUK
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권2호
    • /
    • pp.412-420
    • /
    • 2005
  • In order to investigate factors affecting the denitrification in the F-STEP PROCESS using a loess ball as support media and Pseudomonas DWC 17-8, calcining temperature, loess ball size, pH, nitrate concentration, working temperature, and inhibitor were studied in batch mode using synthetic sludge. A 5- 10 mm of loess ball (960$^{circ}$ of calcining temperature) was the most suitable for denitrification. When the initial pH was increased from 3.0 to 7.0, the removal efficiency of nitrate was increased. Specifically, at initial pH of 7.0, the maximum removal efficiency of nitrate was 5.0 mg/min. When the initial concentration of nitrate was increased from 100 to 400 mg/l, the removal efficiency of nitrate was proportional to the concentration of nitrate. The maximum removal efficiency of nitrate was 5.72 mg/min at 400 mg/l of initial concentration. When the operating temperature was increased from 10 to 30$^{circ}$, the removal efficiency of nitrate was increased from 0.76 to 6.15 mg/min, and at above 40$^{circ}$ of operating temperature, it was decreased from 4.0 to 2.0 mg/min. Among the various inhibitors, higher than 10$^{-1}$ M of sodium azide abolished this reaction completely. When the KCN concentration was above 10$^{-1}$ M, the reaction was inhibited completely. In the case of 2,4-dinitrophenol and sodium sulphide, it was inhibited at above 10$^{-2}$ M completely. For testing the various flow orders of the F-STEP PROCESS for effective denitrification using practical wastewater, continuous experiments under the optimum conditions were carried out for 60 days. Among the various processes, the PROCESS A gave the highest efficiencies of denitrification, nitrification, and total nitrogen (TN) removal with 86.5, 89.5, and $90\%$, respectively. For scale-up in the PROCESS A, real farm wastewater was used and pilot tests carried out for 90 days. The denitrification efficiency was $97.5\%$, which was increased by $12.7\%$. The efficiencies of TN removal and nitrification were 96.6 and $70.0\%$, respectively. The removal efficiency of chemical oxygen demand (COD) was $63.7\%$, which was increased by $20\%$.

질소 제거를 위한 전기화학적 처리 공정의 최적 운전조건 및 폐수 성상에 따른 영향에 관한 연구 (A Study on the Optimum Operating Conditions and Effects of Wastewater Characteristics in Electrochemical Nitrogen Removal Process)

  • 심주현;강세한;서형준;송수성
    • 대한환경공학회지
    • /
    • 제31권1호
    • /
    • pp.29-34
    • /
    • 2009
  • 표면처리폐수 내 질산성 질소를 제거하기 위한 전기화학적 처리공정에서 전극간격, 환원제, 1단 처리수 반송, 타 물질과 동시 처리 등 네 가지 조건을 변화시키며 실험을 진행하였다. 실험 결과, 전극간격은 10 mm일 때 질산성 질소 제거효율이 높았으며 10 mm 보다 전극간격이 좁아질 경우 농도분극 현상의 증가로 인해 제거효율이 감소하며 10 mm 보다 넓어질 경우 전압이 상승하여 에너지 소모가 증가하였다. 환원제 영향에 대한 실험 결과, 질산성 질소가 환원되는 과정에서 수소가 소모되기 때문에 수소이온 농도가 높은 산성조건에서 더 원활한 환원반응이 이루어졌으며 아연을 1.2배 투입할 경우 질산성 질소와의 반응량이 증가하여 질산성 질소 제거효율이 증가하였다. 1단 처리수를 반송할 경우 난류가 형성되어 환원전극에 부착된 아연이 탈착되어 재 이용되고 내부 확산이 증가하여 농도분극현상이 감소함으로 인해 질산성 질소 제거효율이 증가하였으며 아연 투입량 감소 효과가 나타났다. 암모니아성 질소는 질산성 질소 제거에 영향을 미치지 않았고 폐수 내 염소성분이 충분할 경우 질산성 질소와 동시 처리에도 문제가 없는 것으로 나타났다. 중금속은 환원되는 과정에서 전자를 소모하여 질산성 질소 제거효율은 감소하지만 전류밀도 증가나 본 장치의 전단을 중금속 제거용으로 사용하는 방법 등으로 해결이 가능할 것으로 생각한다.

Performance of PEG on immobilization of zero valent metallic particles on PVDF membrane for nitrate removal

  • Chan, Yi Shee;Chan, Mieow Kee;Ngien, Su Kong;Chew, Sho Yin;Teng, Yong Kang
    • Membrane and Water Treatment
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2018
  • The principal objective of this study is to investigate the effect of Polyethylene Glycol (PEG) crosslinking in Polyvinylidene Fluoride (PVDF) in immobilization of Fe and bimetallic Fe/Cu and Cu/Fe zero valent particles on the membrane and its efficiency on removal of nitrate in wastewater. PVDF/PEG polymer solution of three weight compositions was prepared to manipulate the viscosity of the polymer. PEG crosslinking was indirectly controlled by the viscosity of the polymer solution. In this study, PEG was used as a modifier of PVDF membrane as well as a cross-linker for the immobilization of the zero valent particles. The result demonstrates improvement in immobilization of metallic particles with the increase in crosslinking of PEG. Nitrate removal efficiency increases too.

혐기성 슬러지에 의한 폐수의 질소 제거에 관한 연구 (A Study on the Nitrogen Control in the Wastewater by Upflow Anaerobic Sludge Blanket.)

  • 은종극
    • 환경위생공학
    • /
    • 제12권2호
    • /
    • pp.75-81
    • /
    • 1997
  • The study was investigated with denitrification of wastewater containing nitrate using upflow anaerobic sludge blanket process. Contents of this study were the determination of nitrate removal efficiency by various hydrogen donor addition, relationship between HRT, nitrate loading rate and growth constant of microorganism in case or various hydrogen donor addition etc. Results from this study were summurized as follows. In case of adding methanol, ethanol, sodium acetate as hydrogen donor, treatability of wastewater contained 200mg/l as nitrate was about 91%. But in addition of ethanol, sodium acetate in wastewater contained 40mg/l as nitrate, nitrate removal efficiency was 80%. While the treatment of nitrate showed the yield coefficient of microorganisms(Y) as 234.8, 234.35, and 247.68 g/VSS/g nitrate, respectively, showed specific growth rate(K) as 0.885, 0.934 and 0.917 respectively.

  • PDF

Efficiency of a hybrid solid digestion-denitrification column in suspended solid and nitrate removal from recirculating aquaculture system

  • Pungrasmi, Wiboonluk;Chaisri, Ratchadaporn;Malaphol, Ekachai;Powtongsook, Sorawit
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.175-180
    • /
    • 2015
  • This research focused on the solid and nitrate removal efficiency in a solid digestion-denitrification column. The 20 L up-flow column consisted of 18 L acrylic column with 2 L down-comer inlet tube located in the middle. In the first part, the wastewater with high suspended solids from the Tilapia fish tank was applied into the sedimentation unit at 5 variable flow rates i.e., 11.25, 25.71, 60, 105.88 and 360 L/h. The results indicated that the flow rate of 11.25 L/h (0.57 m/h) gave the highest solid removal efficiency of $72.72%{\pm}8.24%$. However, the total suspended solids removal was highest at 360 L/h (18.13 m/h). In the second part, methanol was added as an external organic carbon source for denitrification process in a hybrid column containing settled solids. The COD:N ratios of 0.5:1, 1:1, 2:1, 3:1, 4:1, 5:1 and 6:1 were investigated and compared with control without methanol addition. This experiment was operated at the HRT of 1 h with 450 L wastewater from recirculating aquaculture pond containing 100 mg-N/L sodium nitrate. The results indicated that the COD:N ratio of 3:1 gave the highest nitrate removal efficiency of $33.32%{\pm}21.18%$ with the denitrification rate of 5,102.88 mg-N/day.

순환여과식 양식 시스템에 있어서의 고정화 탈진균에 의한 질산염 제거 (Nitrate Removal by Immobilized Denitrifying Bacteria in Recirculating Aquaculture System)

  • 김상희;김필균;김중균
    • 생명과학회지
    • /
    • 제9권6호
    • /
    • pp.698-703
    • /
    • 1999
  • For the nitrate removal in recirculating aquaculture system, a denitrifying bacterium, Pseudomonas fluorescens, was isolated from municipal sewage and the cells were immobilized in modified-polyvinly alchol (PVA) gel beads. The immobilized cells in both the fixed-and fluidized-bed reactors showed 98% of denitrification efficiency with 6hr HRT, and the removal efficiency of total organic carbon (TOC) was above 90%. Form scanning electron microscopy (SEM) observation, it was known that biofilm formed in fixed-bed reactor was thicker than that formed in fluidized-bed reactor as operation time passed.

  • PDF