• Title/Summary/Keyword: removable dentures

Search Result 144, Processing Time 0.029 seconds

Valplast$^{(R)}$ flexible removable partial denture for a patient with medically compromised conditions : a clinical report (전신적 질환자 및 예후가 불량한 환자에서 Valplast$^{(R)}$ 탄성 국소의치의 적용)

  • Choi, Bohm;Kim, Seong-Hun;Lee, Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.295-300
    • /
    • 2009
  • Statement of problem: As the number of elders is growing with the advancement of medicine, partially or fully edentulous patients have increased. Medically compromised conditions are common in the older population so that it should be taken into account in prosthetic treatment planning as well as their economic conditions. In the older patients, removable prosthesis has been preferred to implant prosthesis. However, cast metal based removable partial dentures also has several limitations. Purpose: In this report, we present several cases of Valplast$^{(R)}$ flexible denture which were fabricated in patients who had medically compromised conditions or whose remaining teeth showed a relatively poor prognosis. Results & Conclusion: This article describes an alternative treatment for a partially edentulous patient with mouth opening limitation, after cancer surgery, compromised general condition and questionable remaining teeth. In these patients, Valplast$^{(R)}$ flexible denture was used because of its unique characteristics and the results were all satisfactory. Patients had 1-2 check-up and there were no postoperative pain or fracture of denture up to now.

Implant-assisted removable partial denture restoration in small number of residual teeth in mandible: A case report (하악 소수 잔존치 환자에서 임플란트 보조 국소의치 수복 증례)

  • Jong-Ha Park;Jee-Hwan Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.215-223
    • /
    • 2024
  • The patient in this case presented with a desire to have new dentures due to discomfort with existing ones. At the initial visit, all of teeth were missing except for the mandibular left second molar. As the patient was 65 years old, treatment with dentures and implant-supported prostheses was possible under the national health insurance system, and the patient opted for the mandibular denture using implant. Temporary prostheses were initially provided for patient adaptation, and following successful adaptation period, the treatment progressed. A maxillary complete denture and a mandibular implant-supported denture using two implants in the canines were fabricated. The mandibular denture is a Kennedy Class II removable partial denture which consists of a six-unit porcelain fused to metal fixed dental prostheses supported by the implant in the canines on both sides and left second molar serving as the abutments. Despite severe bone resorption and insufficient abutment teeth, the patient expressed satisfaction with the treatment results. In cases with economic and anatomical constraints affecting the feasibility of complete denture, implant-supported overdenture, and implant-supported fixed dental prostheses, an implant-assisted removable partial denture using implant surveyed crowns proves to be a viable and effective alternative treatment option. Nevertheless, the current dearth of scientifically rigorous studies underscores the necessity for meticulous regular check-up and occlusal assessment.

Factors influencing the frequency of denture adjustments after delivery of complete denture: a retrospective study (총의치 장착 후 의치 조정 횟수에 영향을 미치는 요인에 관한 후향적 연구)

  • Lee, Seungwon;Yoon, Joon-Ho;Yoo, Jin-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.239-245
    • /
    • 2022
  • Purpose. The purpose of this study was to analyze the frequency and duration of adjustments after delivery of complete denture according to age, sex, arch with complete denture, insurance coverage of a denture, type of antagonist, the experience of wearing denture, the period of edentulism, and the type of denture base. Materials and methods. For 5 years, medical records of patients aged 65 or older who had treated full dentures were assessed for the frequency and duration of follow-up visits after complete denture delivery. Statistical analysis was performed at the 5% level of significance to analyze the correlation between the frequency and duration of follow-up according to sex, insurance coverage, arch with the complete denture, type of denture base, type of antagonist, experience of wearing a denture, age, and healing period. Results. 247 complete dentures were included in this study. The median frequency of follow-up visits was 3, and the median duration of follow-up was 36 days. Lower dentures had significantly higher frequency of follow-up visits than upper dentures (P = .036). According to the type of antagonist, dentures opposing a complete denture had a significantly higher frequency of follow-up visits than dentures opposing a removable partial denture (P = .016). There was no statistically significant difference in the frequency and duration of adjustments after delivery of complete denture by age, sex, insurance coverage, healing period, the experience of wearing a denture, and type of denture base. Conclusion. Within the limitations of the present study, lower complete dentures or dentures opposing a complete denture had an increased frequency of follow-up visits.

A SURVER OF THE ACTUAL CONDITIONS ON THE PRODUCTION OF DENTAL PROSTHESIS (치과보철기공물 제작실태에 관한 조사연구)

  • Bae, Jung-Soo;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.358-394
    • /
    • 1995
  • The author studied the actual conditions on the production of dental prosthesis made in laboratories, and also studied interrelationships between dentists and laboratory technicians in both personal and technical aspects. Two hundred-eighty four technicians, work in dental laboratories presently, were surveyed via mail and direct contact during the period from June 1 to June 30 and August 27 to August 28 in 1994 respectively. The obtained results were as follows : 1. Among the respondents, 90.5% we re working in commercial dental laboratories and their laboratories were mainly located in the Seoul area(40.9%, P<0.05). The numbers of employees in these laboratories were less than 10 persons(70.0%, P<0.01), and 75.9% of these laboratories have been in operation less than 15 years. 2. Most laboratory procedures were accomplished according to established disciplines. However, procedures such as die trimming in fixed restorations and the qualifications of the people designing removable partial dentures were not. Other problem areas were boxing of the working cast, the person determining the posterior palatal seal area, selection and arrangement of artificial teeth, occlusion rim correction and laboratory remounting of the processed denture in complete denture restorations. 3. Only half of the requesting dentists could send work authorizations to the laboratories with their work and even so, its contents were quite lacking. Consequently, there must be some standards in writing work authorization. 4. Technicians most desired clean and accurate impressions in fixed and removable dentures, and enough tooth reduction in porcelain fused to metal restorations. 5. For the establishment of better relationships between dentist and dental technician, the respondents desired the establishment of equal footing first(33.5%), and frequent conversations and muture understanding second(25.9%).

  • PDF

A STUDY ON THE FATIGUE AND PHYSICAL PROPERTIES OF TITANIUM USED IN REMOVABLE PARTIAL DENTURES (국소의치용 티나늄의 피로도 및 물리적 성질에 관한 연구)

  • Kim Hak-Sun;Kim Kwang-Nam;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.249-267
    • /
    • 1994
  • The purpose of this study was to compare the fatigue, physical properties, flexibility and surface roughness of titanium used in removable partial dentures with those of a type IV and alloy and a cobalt- chromium alloy. Fatigue testing subjected the test specimen to rapid cycling at a given stress until failure occurred by using a small-sized, electrodynamic type bending fatigue testing machine. The S-N curves for the framework materials were generated. For tensile testing, a tensile bar as described in the ADA Specification No.14 was subjected to tensile loading until failure occurred. Load-displacement curves were generated for 18 gauge round specimen and tapered half round specimen. Then the flexibilities were calculated. The surface roughnesses were compared by analyzer. Through analyses of the data, the following conclusions were obtained. 1. The fatigue property of titanium was higher than that of a type IV gold alloy$(p\leq0.05)$, but there was no significant difference between titanium and a cobalt-chromium alloy $(p\geq0.05)$. 2. The yield strength, the ultimate tensile strength and Victors hardness of titanium were higher than those of a type IV gold alloy but lower than those of a coalt-chromium alloy$(p\leq0.05)$. 3. The percentage of elongation and reduction of area of titanium were the highest $(p\leq0.05)$. 4. The surface roughness of titanium was the greatest$(p\leq0.05)$. 5. The flexibility of titanium was lower than that of a type IV gold alloy but higher than that of a cobalt-chromium alloy$(p\leq0.05)$.

  • PDF

PERIODONTAL AND PROSTHETIC FINDINGS IN PATIENTS TREATED WITH REMOVABLE PARTIAL DENTURES OR DISTALLY EXTENDING CANTILEVER BRIDGES (가철성 국소의치와 후방연장 계속가공의치를 장착한 환자의 치주 및 보철 상태)

  • Kim, Jeong-Chan;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.635-645
    • /
    • 1993
  • This study was perfomed to investigate the prosthodontic and periodontal status of the abutment teeth in distally extending bridges(DEBs) (78 cases) and removable partial dentures(RPDs) (43 cases) for 122 patients (55 males and 57 females) visiting department of Periodontology, Seoul National University Hospital. The average wearing periods were 67.8 months for DEBs and 66.4 months for RPDs. 38.4% of the patients in DEBs and 35.9% in RPDs complainted of chewing discomfort and 22.6% and 24.4% were not chewing on the prosthodontically - treated sides, respectively. In DEBs, when the restoration for 2nd molar supported by 1st molar & 2nd premolar was grouped to type 1, 1st molar supported by 1st & 2nd premolars was type 2, and 1st & 2nd molars supported by 1st & 2nd premolars was type 3, there was a significant differences only in the tooth mobility score among clinical parameters (type 2>type 1>type 3). In RPDs, when bilateral free-end case was grouped to type 1, and unilateral case was type 2, there was a significant difference in the Gingival index (type 1>type 2). In DEBs, 62.8% of restoration were overcontoured, 72% had interproximal space closures, 30.5% overextended pontics and 86.6% overhanging margins. In RPDs, 24.4% of the restorations were overcontoured, 45.5% had interproxinal space closures and 58.3% overhanging margins. From these results of this study, periodontal problems caused by prosthodontic defects were considered to be contributing factors in chewing discomfort.

  • PDF

Clinical and radiographic evaluations of implants as surveyed crowns for Class I removable partial dentures: A retrospective study

  • Yoo, Soo-Yeon;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.108-121
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate survival rates and marginal bone loss (MBL) of implants in IC-RPDs. MATERIALS AND METHODS. Seventy implants were placed and used as surveyed crowns in 30 RPDs. The survival rates and MBL around implants based on multiple variables, e.g., position, sex, age, opposing dentitions, splinting, type of used retainer, and first year bone loss, were analyzed. Patient reported outcome measures (PROMs) regarding functional/esthetic improvement after IC-RPD treatment, and complications were also inspected. RESULTS. The 100% implant survival rates were observed, and 60 of those implants showed MBL levels less than 1.5 mm. No significant differences in MBL of implants were observed between implant positions (maxilla vs. mandible; P = .341) and type of used retainers (P = .630). The implant MBL of greater than 0.5 mm at 1 year showed significantly higher MBL after that (P < .001). Splinted implant surveyed crowns showed lower MBL in the maxilla (splinted vs. non-splinted; P = .037). There were significant esthetic/functional improvements observed after treatment, but there were no significant differences in esthetic results based on implant position (maxilla vs. mandible). Implants in mandible showed significantly greater improvement in function than implants in the maxilla (P = .002). Prosthetic complication of IC-RPD was not observed frequently. However, 2 abutment teeth among 60 were failed. The bone loss of abutment teeth was lower than MBL of implants in IC-RPDs (P = .001). CONCLUSION. Class I RPD connected to residual teeth and strategically positioned implants as surveyed crowns can be a viable treatment modality.

Implant assisted removable partial denture with implant surveyed crown: A 20-month follow-up case report (단일 임플란트 서베이드 크라운을 이용한 하악 임플란트 융합 국소의치: 20 개월 경과 관찰 증례 보고)

  • Roh, Kyoung-Woo;Jeon, Young-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.323-329
    • /
    • 2018
  • Traditional options for posterior edentulous treatment include removable partial dentures and implant fixed prostheses. Recently, the concept of implant assisted removable partial denture, in which two treatments are fused, has been introduced in consideration of systemic health and patient's needs, costs, residual alveolar bone status and so on. Implant assisted removable partial denture has the advantage of increasing the retention and stability of the denture and improving its esthetics in cases of large bone defects or biomechanical disadvantages. In addition, it is possible to strategically place the implants in a site where the alveolar bone is relatively sufficient, thereby overcome the limit of the conventional removable partial denture design as well as reducing the burden on a wide range of implant surgery. Cost reduction is also expected. In this case, the patient was treated by placing the implant in both premolar sites of the mandible and fabricating the distal extension removable partial denture with the implant fixed prosthesis as an abutment. After delivering the definitive prosthesis, the patient showed satisfaction with the masticatory function and esthetics. and has been regularly followed-up for more than one year. The following 20-months follow-up case report describes the design of an implant-assisted-removable partial denture (IARPD) in which two cementretained implant crowns used to provide support and stability.

Full mouth rehabilitation of severely worn dentition with implants and removable partial dentures (심한 마모를 가진 환자에서 임플란트와 가철성 국소의치를 이용한 전악수복 증례)

  • Lee, Shin Eon;Lee, Won Sup;Lee, Cheol Won;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.70-76
    • /
    • 2018
  • Excessive tooth wear can lead to decrease in occlusal vertical dimension and can cause pathological changes in the oral environment and masticatory system. When recovering occlusal vertical dimension and occlusion, accurate diagnosis and analysis are essential. This clinical case describes a 75-year-old woman with severely worn dentition due to loss of the posterior support. Full mouth rehabilitation with occlusal vertical dimension increment was planned. Clinical and radiographic examinations, occlusal vertical dimension evaluation, and diagnostic wax-up were performed and patient adaptability was evaluated using provisional restorations. As for definitive restoration, considering economic condition of the patient, removable partial denture was fabricated and solitary implants were placed in the mandibular left and right posterior region to increase support and retention of the removable partial denture. During one year of follow-up, functional and esthetic outcomes were observed satisfactory.

Comparison of internal adaptation of removable partial denture metal frameworks made by lost wax technique and printing technique of pattern using CAD (Lost wax technique과 CAD를 이용한 pattern의 프린팅 방식으로 제작된 가철성 국소의치 금속구조물의 적합도 비교)

  • Choi, Wonjun;Woo, Yi-Hyung;Kim, Hyeong-Seob;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.17-24
    • /
    • 2018
  • Lost wax technique of casting wax patterns has been used principally to make metal frameworks of removable partial dentures. Since the development of digital technology and CAD, metal frameworks can be built through digital surveying and framework designing. Many cases proved that resin patterns made by CAD printing method were well adapted to internal oral structure and final metal frameworks also showed good internal adaptation as well. The metal frameworks of a removable partial denture were made by both lost wax technique and CAD technique and were applied to a patient with severe alveolar bone loss. Using CAD data and fit checker, internal adaptation of both metal frameworks were evaluated by comparing the gap between surveyed crown and its structure. This study is to prove that metal frameworks by both techniques showed adaptation that can be applied in clinical field.