• Title/Summary/Keyword: reliquefaction

Search Result 21, Processing Time 0.028 seconds

Characteristics of boil-off-gas partial re-liquefaction systems in LNG ships (LNG선박용 BOG 부분재액화 시스템 특성 연구)

  • Yun, Sang-Kook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.174-179
    • /
    • 2016
  • To protect the ocean environment, the use of liquefied natural gas (LNG) carriers, bunkering ships, and fueled ships is increasing. Recently, Korean shipbuilders have developed and supplied a partial reliquefaction facility for boil-off-gas (BOG). Despite reasonable insulation, heat leakage in vessel storage tanks causes LNG to be continuously evaporated as BOG. This research analyzed the maximum liquid yield rate for various partial reliquefaction systems (PRS) and considered related factors affecting yields. The results showed a liquid yield of 48.7% from an indirect PRS system (heat exchanges between cold flash gas and compressed natural gas), and 41% from a direct PRS system (BOG is mixed with flash gas and discharged from a liquid-vapor separator). The primary factor affecting liquid yield was heat exchanger effectiveness; the exchanger's efficiency and insulation characteristics directly affect the performance of BOG reliquefaction systems.

LNG 선박 건조현황과 인력수요 예측

  • Park, Jin-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.93-95
    • /
    • 2006
  • 최근 LNG 선박의 발주량이 급증함에 따라 LNG 선에 승무할 인력의 심각한 부족이 예상되고 있다. 이러한 LNG 선박에 승무할 인력 특히 고급 사관의 부족은 선박 자체의 안전뿐 아니라 궁극적으로는 LNG 수송체계의 안전에도 큰 영향을 미치게 될 것이다. 이 발표에서는 현재 전세계 상선대의 현황에서 출발하여, 최근 LNG 선박의 발주 현황, LNG 선박에 적용되는 최신 기술 및 엔진 등에 대하여 살펴 본 후에 전세계 LNG 선박 수주 잔량을 근거로 하여 필요 인력을 예측해 본다.

  • PDF

The New Trend of Propulsion and BOG Handling System from LNGCs (최근 LNG선의 추진 및 BOG 처리장치의 동향)

  • Kim, M.E.;Lee, K.W.;Lee, Y.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.940-945
    • /
    • 2005
  • In recent years, the LNGC fleet is expanded unprecedentedly. Ship's owners and shipbuilders are focusing on technology and reliability of new propulsion system from economical, environmental and safety angles. This paper give describes the new trend of propulsion system and boil off gas handling system from LNG carriers.

  • PDF

Study on the Comparison of New and Used Reliquefaction System of Boil-Off-Gas by LNG Cold Energy (냉열을 이용한 LNG 증발기체 BOG 재액화 신공정과 기존공정에 관한 비교연구)

  • Lee, Dong-Hyuck;Jang, Chang-Bong;Jung, Sang-Yong;Kim, Jung-Hwan;Lee, Heon-Seok;Kim, Bum-Su;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.42-46
    • /
    • 2010
  • BOG(Boil Off Gas) is formed about 0.05 vol%/day from LNG(Liquefied Natural Gas) tanks of LNG receiving terminal. To recycle the BOG using direct contacting, Previously the quantities of LNG and BOG is mixed at the ratio of 11:1 by mass. However simple this process uses, there is the difficulty of processing operation resulted from decrease of using LNG in summer. To complement these shortcomings, Advantages of the process are investigated by comparison of cost and analysis of the indirect contact method using LNG cold energy. It was studied that principles and types of development using LNG cold energy which is abandoned in the carburettor and found how to contact each to find the appropriate cold energy development process. Therefore, in this research, the indirect contact method will be investigated the feasibility of a comparative analysis by using HYSYS.

Economic Optimization Study for a $125,000m^3$ Class LNG Carrier

  • Lee, Kyu-Yeul;Lee, Dong-Kon;Jung, Ho-Hyun;Lee, Chul-Hee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.4
    • /
    • pp.1-9
    • /
    • 1984
  • This study is concerned with the economic aspects of $125,000m^3$ class LNG carriers with different propulsion plant such as conventional steam turbine and slow speed diesel engine with reliquefaction plant. The ship's speed and L/B ratio were optimized with criterion of required freight rate(RFR) by using the PROCAL computer program package. In order to investigate the effect of fuel oil price, round trip distance and boil-off rate on the RFR and the optimum speed, sensitivity analysis were also performed.

  • PDF

A Study on the Experimental Measurements and Its Recovery for the Rate of Boil-Off Gas from the Storage Tank of the CO2 Transport Ship (CO2 수송선 저장탱크의 BOG 측정 실험 및 회수에 관한 연구)

  • Park, Jin-Woo;Kim, Dong-Sun;Ko, Min-Su;Cho, Jung-Ho
    • Clean Technology
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • $CO_2$ is generated by the combustion reaction, when getting the energy from fossil fuel. If the carbon dioxide emissions increases more, the global warming problem will become more serious. CCS (carbon capture storage) needs to be developed for the prevention of this. When liquefied $CO_2$ is transported, BOG (boil-off gas) is generated because of several problems. In the study, by injecting liquefied $CO_2$ in two tanks which contains $40m^3$each, the amount of BOG and its composition were measured during 30 days when generating pressure changes and external heat, loading, unloading. In result, 16,040 kg of BOG was generated and the composition has been found out to be 99.95% $CO_2$ and 0.05 % $N_2$. Also, we conducted simulation process for reliquefaction of generated BOG with vapor compression cycle using the PRO/II with PROVISION version 9.2. As a result, the refrigeration cycle of the total circulation flow rate was 42.07 kg/h and the condenser utility consumption was 48.85 kg/h.

Development of partial liquefaction system for liquefied natural gas carrier application using exergy analysis

  • Choi, Jungho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.5
    • /
    • pp.609-616
    • /
    • 2018
  • The cargo handling system, which is composed of a fuel gas supply unit and cargo tank pressure control unit, is the second largest power consumer in a Liquefied Natural Gas (LNG) carrier. Because of recent enhancements in ship efficiency, the surplus boil-off gas that remains after supplying fuel gas for ship propulsion must be reliquefied or burned to regulate the cargo tank pressure. A full or partial liquefaction process can be applied to return the surplus gas to the cargo tank. The purpose of this study is to review the current partial liquefaction process for LNG carriers and develop new processes for reducing power consumption using exergy analysis. The developed partial liquefaction process was also compared with the full liquefaction process applicable to a LNG carrier with a varying boil-off gas composition and varying liquefaction amounts. An exergy analysis showed that the Joule-Thomson valve is the key component needed for improvements to the system, and that the proposed system showed an 8% enhancement relative to the current prevailing system. A comparison of the study results with a partial/full liquefaction process showed that power consumption is strongly affected by the returned liquefied amount.

A Study on Reliquefaction Behavior of Railway Embankment Using 1g Shaking Table Test (1g 진동대 실험을 이용한 철도 제방의 재액상화 거동 연구)

  • Chae, Minhwan;Yoo, Mintaek;Lee, Il-Wha;Lee, Myungjae
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.11
    • /
    • pp.71-81
    • /
    • 2021
  • The purpose of this study is liquefaction phenomenon was simulated using the 1g shaking table test. Analysis of liquefaction and Re-liquefaction behavior according to the ground conditions was analyzed when an embankment exists above the ground. The soil used in the experiment was silica sand and the ground composition was a liquefied layer of 50cm (Case 1), a non-liquefied layer of 17.5cm and a liquefied layer of 32.5cm (Case 2). The embankment was formed by fixing the height of 10cm and the slope of the slope at a ratio of 1:1.8. For seismic waves, excitation of a 5Hz sine wave was performed for 8 seconds, and a total of 5 case excitations were performed. In Case 1, it was confirmed that liquefaction occurred at all depths during the first vibration excitation at the free-field and that liquefaction did not occur at all depths except 5cm at the third vibration excitation. At the center of the embankment, liquefaction occurred up to a depth of 20cm during the first vibration excitation, and it was confirmed that liquefaction did not occur at all depths except for a depth of 5cm during the second vibration excitation.