• Title/Summary/Keyword: reliable index

Search Result 623, Processing Time 0.026 seconds

Infantile Hypertrophic Pyloric Stenosis (IHPS) -Early postoperative changes of pylorus after pyloromyotomy using ultrasonogram in patients with IHPS- (영아 비후성 유문부 협착증에서 초음파 검사를 이용한 수술 후 유문부의 조기 변화)

  • Baik, Hong-Kyu;Jung, Poong-Man;Kim, Yong-Soo
    • Advances in pediatric surgery
    • /
    • v.5 no.1
    • /
    • pp.64-68
    • /
    • 1999
  • The length, diameter and muscle thickness of the pylorus were measured by ultrasonograms in 15 infants with infantile hypertrophic pyloric stenosis(IHPS). These measurements were compared to assemble measurements of infants who came in for the routine vaccination and underwent ultrasonogram. This study also studied by ultrasound the changes in the pylorus of patients who underwent pyloromyotomy 4 weeks and 8 weeks postoperatively. According to $Carver^5$, the pyloric muscle volume(PMV) and pyloric muscle index(PMI) were calculated in each case. The pyloric muscle volume, PMI and the thickness of pyloric muscle proved to be a more reliable guide to diagnose IHPS than length and diameter of pylorus. The pyloric muscle length, diameter, thickness and pyloric muscle volume were not normalized at 4 and 8 weeks after pyloromyotomy. However, pyloric muscle index was normalized at 4 weeks postoperatively perhaps as the result of rapid weight gain after pyloromyotomy.

  • PDF

Analysis of Hydrologic Geo-Spatial Information Using Runoff-Management Model (유출관리모형을 활용한 수문학적 공간정보 분석)

  • Lee, Sang-Jin;Noh, Joon-Woo;Ahn, Jung-Min;Kim, Joo-Cheol
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.1
    • /
    • pp.97-104
    • /
    • 2009
  • GIS (Geographic Information System) is very useful in describing basin wide geographic characteristics and hydrologic analysis. This study estimated long term hydrologic variations in the Geum river basin using the SSARR rainfall runoff simulation model to provide reliable hydrologic information associated with rainfall runoff management module. Calibrated various hydrologic information such as soil moisture index, water use, direct and base flow are generated using GIS tools to display spatial hydrologic information in the unit of subbasin of target watershed. In addition, the graphic user interface toolkit designed for data compilation is expected to support efficient basin wide rainfall runoff analysis.

  • PDF

Sound Quality evaluation of the interior noise for the driving vehicle using Mahalanobis Distance (Mahalanobis Distance 를 이용한 주행중 차량 실내소음의 음질평가)

  • Park, Sang-Gil;Kim, Ho-San;Bae, Chul-Yong;Lee, Bong-Hyun;Oh, Jae-Eung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.318-321
    • /
    • 2007
  • Since human listening is very sensitive to sound, a subjective index of a sound quality is required. Therefore, in the analysis for each situation, the sound evaluation is composed with sound quality factor. Many researchers spends their effort to make a more reliable and more accurate of sound in term of sound quality index for various system noise. The previous methods to evaluation of the SQ about vehicle interior noise are linear regression analysis of subjective SQ metrics by statistics and the estimation of the subjective SQ values by neural network. But these are so depended on jury test very much that they result in many difficulties. So, to reduce jury test weight, we suggested a new method using Mahalanobis distance for SQ evaluation. Threrefore, in this study Mahalanobis distance for the vehicle interior noise was derived using the objective SQ except jury test. Finnaly, the results of the SQ evaluation was analyzed discrimination between reference and abnormal group.

  • PDF

Localized evaluation of actuator tracking for real-time hybrid simulation using frequency-domain indices

  • Xu, Weijie;Guo, Tong;Chen, Cheng
    • Structural Engineering and Mechanics
    • /
    • v.62 no.5
    • /
    • pp.631-642
    • /
    • 2017
  • Accurate actuator tracking plays an important role in real-time hybrid simulation (RTHS) to ensure accurate and reliable experimental results. Frequency-domain evaluation index (FEI) interprets actuator tracking into amplitude and phase errors thus providing a promising tool for quantitative assessment of real-time hybrid simulation results. Previous applications of FEI successfully evaluated actuator tracking over the entire duration of the tests. In this study, FEI with moving window technique is explored to provide post-experiment localized actuator tracking assessment. Both moving window with and without overlap are investigated through computational simulations. The challenge is discussed for Fourier Transform to satisfy both time domain and frequency resolution for selected length of moving window. The required data window length for accuracy is shown to depend on the natural frequency and structural nonlinearity as well as the ground motion input for both moving windows with and without overlap. Moving window without overlap shows better computational efficiency and has potential for future online evaluation. Moving window with overlap however requires much more computational efforts and is more suitable for post-experiment evaluation. Existing RTHS data from Network Earthquake Engineering Simulation (NEES) is utilized to further demonstrate the effectiveness of the proposed approaches. It is demonstrated that with proper window size, FEI with moving window techniques enable accurate localized evaluation of actuator tracking for real-time hybrid simulation.

Automated Segmentation of the Lateral Ventricle Based on Graph Cuts Algorithm and Morphological Operations

  • Park, Seongbeom;Yoon, Uicheul
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • Enlargement of the lateral ventricles have been identified as a surrogate marker of neurological disorders. Quantitative measure of the lateral ventricle from MRI would enable earlier and more accurate clinical diagnosis in monitoring disease progression. Even though it requires an automated or semi-automated segmentation method for objective quantification, it is difficult to define lateral ventricles due to insufficient contrast and brightness of structural imaging. In this study, we proposed a fully automated lateral ventricle segmentation method based on a graph cuts algorithm combined with atlas-based segmentation and connected component labeling. Initially, initial seeds for graph cuts were defined by atlas-based segmentation (ATS). They were adjusted by partial volume images in order to provide accurate a priori information on graph cuts. A graph cuts algorithm is to finds a global minimum of energy with minimum cut/maximum flow algorithm function on graph. In addition, connected component labeling used to remove false ventricle regions. The proposed method was validated with the well-known tools using the dice similarity index, recall and precision values. The proposed method was significantly higher dice similarity index ($0.860{\pm}0.036$, p < 0.001) and recall ($0.833{\pm}0.037$, p < 0.001) compared with other tools. Therefore, the proposed method yielded a robust and reliable segmentation result.

Measuring health activation among foreign students in South Korea: initial evaluation of the feasibility, dimensionality, and reliability of the Consumer Health Activation Index (CHAI)

  • Park, MJ;Jung, Hun Sik
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.192-197
    • /
    • 2020
  • Foreign students in South Korea face important challenges when they try to maintain their health. As a measure of their motivation to actively build skills for overcoming those challenges, we evaluated the 10-item Consumer Health Activation Index (CHAI), testing its feasibility, dimensionality, and reliability. There were no missing data, there was no floor effect, and for the total scores the ceiling effect was trivial (< 2%). Results of the Kaiser-Meyer-Olkin test and Bartlett's test of sphericity indicated that the data were suitable for the detection of structure by factor analysis. The results of parallel analysis and the shape of the scree plot supported a two-factor solution. One factor had 3 items concerning "my doctor" and the other factor had the 7 remaining items. Reliability was high for the 10-item CHAI (alpha = 0.856), for the 3-item subscale (alpha = 0.838), and for the 7-item subscale (alpha = 0.857). Reliability could not be improved by deletion of any items. Use of the CHAI to gather data from these foreign students is feasible, and reliable results can be obtained whether one uses the total score from all 10 items or scores from the proposed 7-item and 3-item subscales.

Rasch Analysis of the Korean Version of the Fullerton Advanced Balance Scale

  • Jeon, Yong-jin;Kim, Gyoung-mo
    • Physical Therapy Korea
    • /
    • v.24 no.4
    • /
    • pp.20-28
    • /
    • 2017
  • Background: Rasch analysis has the advantage of placing both the items and the person along a single ratio scale and calibrates person ability and item difficulty onto an interval scale by logits. Therefore, Rasch analysis has been recommended as a better method for evaluating functional outcome questionnaires than traditional analyses. Objects: The aim of current study was to investigate item fit, item difficulty, rating scale, and separation index of the Korean version of the Fullerton Advanced Balance (KFAB) scale using Rasch analysis. Methods: In total, 93 patients with stroke (male=58, female=35) participated in this study. To investigate the item fit, difficulty, rating scale, and separation index of the KFAB scale, Rasch analysis was completed by the Winsteps software program. Results: In this study, all items of the KFAB scale were included in the Rasch model. The most difficult item was 'standing with feet together and eyes closed', and the easiest item was 'two-footed jump'. The rating scale was a 4-point scale instead of the original 5-point scale. Person and item separation indices showed high values that can identify a person with a wide range of balance ability. Conclusion: The KFAB scale appears to be a reliable and valid tool to assess balance function in patients with stroke. Furthermore, the scale was found to discriminate among stroke patients of varying balance abilities.

A Study on the Kansas Marital Satisfaction Scale (결혼 만족도 척도에 관한 연구 - Kansas Marital Satisfaction Scale을 중심으로)

  • 김득성
    • Journal of Families and Better Life
    • /
    • v.7 no.2
    • /
    • pp.85-94
    • /
    • 1989
  • The purpose of the study was to examine the characteristics of the Kansas Marital Satisfaction Scale(KMSS). KMSS was designed as a short and direct assessment of marital satisfaction. The scale consists of three items where respondents are directly asked how satisfied they are with their marriage, with their partner as a spouse, and with their relationship with their spouse. 1) Through item analysis, three items were significant discrimination for husbands and wives. 2) The KMSS consisted of 1 factor for husbands and wives. 3) Cronbach alpha estimates of internal consistency reliability of 93 for husband and of 89 for wives. 4) For wives, the item means between satifaction with their marriage and satisfaction with their relationsphip with their husbands were significantly different, even though the items were highly correlated. For husbands, three item means weren't significantly different. 5) The distribution of responses to the scale for husbands and wives departed si nificantly from normality in terms of skewness and kurtosis. 6) The scale was correlated, in expected directions, with the Marital Comparison Level Index (MCLI) and Marital Instability Index(MII), for husbands and wives. In conclusion, the scale offers promise for use in clinical evaluation and survey research where a brief but reliable measure of marital satisfaction is required.

  • PDF

The Detection of the Internal Defect in the Glass Using Auto Focusing Method (자동 초점 기법을 이용한 유리 내부 결함 검출)

  • Jy, Yong-Woo;Jhang, Kyung-Young;Jung, Ji-Hwa;Kim, Suk-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.1047-1054
    • /
    • 2004
  • Internal defects in the glass, like-as micro-voids, micro-cracks, or inclusions, easily cause the failure when the glass is exposed to the shock or the thermal variation. In order to produce the highly reliable glass product, the precision inspection of the defect in the glass is required. For this purpose, this paper proposes a machine vision technique based on the auto-focusing method, which searches the defect and measures the location under the fact that the edge image of defect must be the most clear when the focal plane of CCD camera is coincided with the defect. As for the search index, the gradient indicator is presented. The basic principles are verified through the simulations for the computer-generated defect images, where the affects of defect shape, gray level of background, and the brightness of the defect image are also analyzed. Finally, experimental results for actual glass specimens are shown to confirm the applicability of this method to the actual field.

Reliability analysis on flutter of the long-span Aizhai bridge

  • Liu, Shuqian;Cai, C.S.;Han, Yan;Li, Chunguang
    • Wind and Structures
    • /
    • v.27 no.3
    • /
    • pp.175-186
    • /
    • 2018
  • With the continuous increase of span lengths, modern bridges are becoming much more flexible and more prone to flutter under wind excitations. A reasonable probabilistic flutter analysis of long-span bridges involving random and uncertain variables may have to be taken into consideration. This paper presents a method for estimating the reliability index and failure probability due to flutter, which considers the very important variables including the extreme wind velocity at bridge site, damping ratio, mathematical modeling, and flutter derivatives. The Aizhai Bridge in China is selected as an example to demonstrate the numerical procedure for the flutter reliability analysis. In the presented method, the joint probability density function of wind speed and wind direction at the deck level of the bridge is first established. Then, based on the fundamental theories of structural reliability, the reliability index and failure probability due to flutter of the Aizhai Bridge is investigated by applying the Monte Carlo method and the first order reliability method (FORM). The probabilistic flutter analysis can provide a guideline in the design of long-span bridges and the results show that the structural damping and flutter derivatives have significant effects on the flutter reliability, more accurate and reliable data of which is needed.