• Title/Summary/Keyword: relay location

Search Result 112, Processing Time 0.023 seconds

Effect of Resource Allocation in Differential Distributed Cooperative Networks with Mixed Signaling Scheme (혼합된 변조 방식을 적용한 차등 분산 협력 네트워크의 자원 할당 효과)

  • Cho, Woong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1131-1136
    • /
    • 2020
  • Cooperative networks enhance the performance of communication systems by combining received signals from the several relay nodes where the source node transmits signals to relay nodes. In this paper, we analyze the effect of resource allocation in cooperative networks. We assume that the cooperative networks use the conventional modulation scheme between the source and relay nodes, and adopt space-time code between the relays and destination node. Both the synchronous and differential modulations are applied for the conventional scheme and differential modulation is used for the space-time code. We consider relay location and energy allocation for resource allocation, and the performance of cooperative networks depending on the number of relay is also investigated.

Knowledge-Based Approach Using Support Vector Machine for Transmission Line Distance Relay Co-ordination

  • Ravikumar, B.;Thukaram, D.;Khincha, H.P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.363-372
    • /
    • 2008
  • In this paper, knowledge-based approach using Support Vector Machines (SVMs) are used for estimating the coordinated zonal settings of a distance relay. The approach depends on the detailed simulation studies of apparent impedance loci as seen by distance relay during disturbance, considering various operating conditions including fault resistance. In a distance relay, the impedance loci given at the relay location is obtained from extensive transient stability studies. SVMs are used as a pattern classifier for obtaining distance relay co-ordination. The scheme utilizes the apparent impedance values observed during a fault as inputs. An improved performance with the use of SVMs, keeping the reach when faced with different fault conditions as well as system power flow changes, are illustrated with an equivalent 265 bus system of a practical Indian Western Grid.

Achievable Rate Region Bounds and Resource Allocation for Wireless Powered Two Way Relay Networks

  • Di, Xiaofei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.2
    • /
    • pp.565-581
    • /
    • 2019
  • This paper investigates the wireless powered two way relay network (WPTWRN), where two single-antenna users and one single-antenna relay firstly harvest energy from signals emitted by a multi-antenna power beacon (PB) and then two users exchange information with the help of the relay by using their harvested energies. In order to improve the energy transfer efficiency, energy beamforming at the PB is deployed. For such a network, to explore the performance limit of the presented WPTWRN, an optimization problem is formulated to obtain the achievable rate region bounds by jointly optimizing the time allocation and energy beamforming design. As the optimization problem is non-convex, it is first transformed to be a convex problem by using variable substitutions and semidefinite relaxation (SDR) and then solve it efficiently. It is proved that the proposed method achieves the global optimum. Simulation results show that the achievable rate region of the presented WPTWRN architecture outperforms that of wireless powered one way relay network architecture. Results also show that the relay location has significant impact on achievable rate region of the WPTWRN.

A Study on Distance Relay characteristics for Transmission Line with the Unified Power Flow Controller (송전선로에 UPFC연계시 거리계전기 동작특성에 관한 연구)

  • Suh, Jung-Nam;Jung, Chang-Ho;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.220-222
    • /
    • 2001
  • This paper represents impedance calculation of the distance relay using PSCAD/EMTDC software for transmission line involving the UPFC (Unified Power Flow Controller) device, which is the most vigorous component of FACTS. The presence of the UPFC significantly affects the line parameters of transmission system, which are also influenced by the distance relay setting. Moreover depending on the UPFC location and its parameters, zones of setting the distance relay will be changed. The presence of the UPFC in the fault loop affects both voltage and current seen by relay. Therefore, the distance relay should be taken into account the variable injected voltage of the UPFC.

  • PDF

Control Strategy against Undesirable Zone 3 Relay Operation in Voltage Instability

  • Lee Byong-Jun;Song Hwa-Chang
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.144-151
    • /
    • 2005
  • This paper presents a framework for determining control strategies against unwanted tripping actions during relay operation that plays a very important role in cascading events leading to voltage collapse. The framework includes an algorithm for quick identification of possible zone 3 relay operation during voltage instability. Furthermore, it comes up with the control strategy of load shedding at the selected location with active power and relay margin criteria. In addition, Quasi Steady-State (QSS) simulation is employed to obtain time-related information that is valuable in the determination of control strategy. As a case study, an example applying the framework is shown with the modified New England 39-bus system.

Agent-Based Distance Relaying Algorithm for Phase-to-Ground Faults (에이전트 환경에서의 1선지락 거리계전 알고리즘)

  • Hyun, Seung-Ho;Jin, Bu-Gun;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1885-1891
    • /
    • 2007
  • This paper presents a distance relaying algorithm for phase-to-ground faults in transmission lines under Multi-Agent protection environment. In normal condition, a distance relay agent stores the latest states, e.g., voltage of source side, voltage of the opposite side and the loading conditions, etc., through communication between the agents. Once a fault occurs, the relay calculates the fault location using the knowledge about the states just before the fault happens. This stand-alone operation is to improve reliability under the fault condition at which the accuracy or time required for communication may not be guaranteed. The mathematical expression of fault location is derived through loop analysis, before hand, in the manner that both fault current from the opposite end and fault resistance are included implicitly so that their effects are minimized. The suggested algorithm is applied to a typical transmission system with two power sources on both ends to show its effectiveness.

The Real-Time Distance Relay Algorithm Using fault Location Estimation Information for Parallel Transmission Line (병행 2회선 송전선로에서 고장점 위치 추정정보를 이용한 실시간 거리계전 알고리즘)

  • 이재규;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • This paper presents the real-time implemented distance relay algorithm which the fault distance is estimated with only local terminal information. When a single-phase-to-earth fault on a two-parallel transmission line occurs, the reach accuracy of distance relay is considerably affected by the unknown variables which are fault resistance, fault current at the fault point and zero- sequence current of sound line The zero-sequence current of sound line is estimated by using the zero sequence voltage which is measured by relaying location Also. the fault resistance is removed at the Process of numerical formula expansion. Lastly, the fault current through a fault point is expressed as a function of the zero-sequence current of fault line, zero-sequence current of sound line, and line, and fault distance. Therefore, the fault phase voltage can be expressed as the quadratic equation of the fault distance. The solution of this Quadratic equation is obtained by using a coefficient of the modified quadratic equation instead of using the square root solution method. After tile accurate fault distance is estimated. the mote accurate impedance is measured by using such an information.

Optimal Transmission Method in Cooperative Relay Communication Systems with Hierarchical Modulation (계층변조를 적용한 협력 중계 통신시스템의 최적 전송기법)

  • Jeon, Min-Cheol;Lee, Su-Kyoung;Seo, Bo-Seok
    • Journal of Broadcast Engineering
    • /
    • v.15 no.2
    • /
    • pp.224-231
    • /
    • 2010
  • In this paper, we analyze the performance of the cooperative relay communication system which uses orthogonal frequency division multiplexing(OFDM) with hierarchical subcarrier modulation. In the cooperative relay communication system, data transmission is accomplished in two time slots. In the first time slot, the source broadcasts the signal to the relay and to the destination. The relay demodulates the received signal, remodulates and forwards it to the destination in the second time slot. The source uses hierarchical modulation for subcarriers to deal with the signal-to-noise power ratio (SNR) difference in the source-relay and source-destination links. The bit error rate (BER) of the relay transmission system with hierarchical modulation depends on the hierarchical modulation parameter. First, we derive the relationship between BER and the parameter, and find the optimal parameter giving the minimum BER through computer simulations. Then, we analyze the performance of the proposed cooperative relay communication system according to the relay location. From this results, we find optimal relay location to maximize the BER performance.

A Study on Receiving Performance Improvement of LTE Using Hybrid OFDMA/SC-FDMA (Hybrid OFDMA/SC-FDMA를 이용한 LTE 수신성능 개선에 관한 연구)

  • Park, Chan-Hong;Jang, Sung-Won;Park, Sang-Joo;Han, Young-Hwan;Seong, Hyeon-Kyeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.158-161
    • /
    • 2010
  • In the paper, the researcher has proposed to install a relay between Base Station (BS) and Mobile Station (MS) to improve receiving performance of the downlink transmission method of Long Term Evolution (LTE) system whose standards now being established by 3GPP. By setting the distance between the location of BS and the relay installed as by 500m, 1000m, and selecting OFDMA and SC-FDMA as transmission method, the researcher conducted a study to improve the receiving performance of LTE. The results from study revealed that when the location of Relay Station (RS) was closer to BS, it was better to use OFDMA at BS, and SC-FDMA at RS. On the contrary, when the distance between BS and RS was farther, it was better to use SC-FDMA at BS, and OFDMA at RS. In addition, around the center zone between the location of BS and of MS, the researcher was able to improve the receiving performance of the system by utilizing the transmission method suitable for the situation in that area.

  • PDF

Application of Fault Location Method to Improve Protect-ability for Distributed Generations

  • Jang Sung-Il;Lee Duck-Su;Choi Jung-Hwan;Kang Yong-Cheol;Kang Sang-Hee;Kim Kwang-Ho;Park Yong-Up
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.137-144
    • /
    • 2006
  • This paper proposes novel protection schemes for grid-connected distributed generation (DG) units using the fault location algorithm. The grid-connected DG would be influenced by abnormal distribution line conditions. Identification of the fault location for the distribution lines at the relaying point of DG helps solve the problems of the protection relays for DG. The proposed scheme first identifies fault locations using currents and voltages measured at DG and source impedance of distribution networks. Then the actual faulted feeder is identified, applying time-current characteristic curves (TCC) of overcurrent relay (OCR). The method considering the fault location and TCC of OCR might improve the performance of the conventional relays for DG. Test results show that the method prevents the superfluous operations of protection devices by discriminating the faulted feeder, whether it is a distribution line where DG is integrated or out of the line emanated from the substation to which the DGs are connected.