• Title/Summary/Keyword: relatively efficiency

Search Result 1,866, Processing Time 0.039 seconds

Evaluation of the Effects of the Longitudinal Baffle on Settling Efficiency within Rectangular-shaped Sedimentation Basin (장방형 침전지내 도류벽의 침전효율에 대한 영향 평가)

  • Park, No-Suk;Kim, Seong-Su;Seo, In-Seok;Min, Kyong-En
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.573-581
    • /
    • 2009
  • In the case that the average velocity within rectangular-shaped sedimentation basin is less than 1.5cm/sec, and Froude number less than $10^{-6}$, it can not be expected that the longitudinal baffle improves the sedimentation efficiency. Also, since relatively lower velocity increases the effect of geostrophic body force, asymmetric flow pattern on a plane occurs within the basin. From the results of CFD (Computational Fluid Dynamics) simulation, in the case that the highest velocity within rectangular-shaped sedimentation basin is over 1.5cm/sec, and Froude number over $10^{-6}$, it can be expected that the longitudinal baffle installed within rectangular-shaped sedimentation basin improves the sedimentation efficiency.

Performance Analysis on the Design Variables of a Turbo Blower (터보블로어 설계인자의 성능특성 연구)

  • Jang, Choon-Man;Yang, Sang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.47-51
    • /
    • 2011
  • This paper describes the shape optimization of a blower impeller used for a refuse collection system. Two design variables, which are used to define the blade angles of an impeller, are introduced to increase the blower performance. A blower efficiency is selected as an object function, and the shape optimization of the blade angles is performed by a response surface method (RSM). Three-dimensional Navier-Stokes equations are introduced to analyze the internal flow of the blower and to find the value of object function for the training data. Relatively good agreement between experimental measurements and numerical simulation is obtained in the present study. Throughout the shape optimization, blower efficiency for the optimal blade angles is successfully increased up to 3.6% compared with that of reference at the design flow rate. Detailed flow field inside the turbo blower is also analyzed and discussed.

A Selection Process of Input and Output Factors Using Partial Efficiency in DEA (부분 효율성 정보를 이용한 DEA 모형의 투입.산출 요소 선정에 관한 연구)

  • 민재형;김진한
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.23 no.3
    • /
    • pp.75-90
    • /
    • 1998
  • The improper use of input and output factors in DEA has a critical and negative impact on the efficiency measurement and the discernment of decision making units(DMUs) : hence the proper selection Process of the factors should precede the actual applications of DEA. In this paper, we propose a new approach to selecting proper factors based on Tofallis' partial efficiency evaluation method(1996). With the approach, the factors aye clustered by measuring their respective partial efficiencies and analyzing the rank correlations of them. The method and procedure we propose in this paper are then applied to measure the efficiencies of the public libraries in Seoul District area, and the results show that the proposed approach can provide meaningful information to improve discernment of the DMUs while using less number of input factors (and less information). The proposed method can be effectively used in the situation where the number of the DMUs to be considered is relatively small compared to the number of available input and output factors, which usually lessens the power to identify the inefficient units in DEA.

  • PDF

Advanced Sewage Treatment by the Modified SBR(Sequencing Batch Reactor) Process (변형 연속회분식 반응기를 이용한 오수의 고도처리)

  • 김병군;서인석;홍성택;정위득
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.46-51
    • /
    • 2002
  • This study was performed to treat a sewage at the upper stream of dam using modified sequencing batch reactor, During the operating period, average $COD_{cr}$, removal efficiency was about 85% but average T-N and ${PO_4}^{3-}-P$ removal efficiencies were 43% and 30% respectively. Because the organic matter was very low compared with nitrogen and phosphorous in influent($BOD_{5}/{NH_4}^{+}-N{\;}={\;}2,{\;}BOD_{5}/{PO_4}^{3-}-P{\;}={\;}15.6$), nitrogen and phosphorus removal efficiency was relatively low. Average nitrogen removal efficiency was 50 % at $10^{\circ}C$ or above and it was 36 % at $10^{\circ}C$ or below. As reactor was located in outdoor without any thermostat, temperature decreased at least $2.4^{\circ}C$ in the winter season. Therefore, if we would apply this modified sequencing batch reactor to sewage which concentration of organic matter was very low compared with nitrogen and phosphorous, we have to addition of external carbon and installation of any thermostat.

A Study On the Development of Facility Management Performance Evaluation system by Analyzing Current FM Practices of Commercial Office Buildings (Commercial Office의 Facility Management(FM) 업무 현황 분석을 통한 성과 평가체계 구축 방안)

  • Yoon, Jong-Han;Cha, Hee-Sung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.89-90
    • /
    • 2016
  • Despite the rise of importance of Facility Management(FM), relatively little attention was paid to evaluate FM efficiency and drive for greater FM efficiency. The purpose of the present paper is to offer a quantitative analysis of 14 Key Success Factors(KSF) and 22 detailed maintenance practices in order to develop FM evaluation system. In addition, from survey with Owner/Property Manager group and Facility Manager group, the present paper measures both importance of detailed maintenance practices and performance satisfaction. It is expected that by using the result of this survey, this paper helps increase efficiency in FM. Moreover, It is expected that this paper will be used as base line data in developing FM practice evaluation system.

  • PDF

Effect of Operating Conditions on Drying Efficiency for Coal Drying Facilities in a Steel Making Plant (제철플랜트용 석탄건조설비에서 운전조건 변경이 건조성능에 미치는 영향)

  • Jeon, Hae-Seak;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.5 no.4
    • /
    • pp.73-79
    • /
    • 2009
  • Increase of consumption in limited coal reserves leads prices surging. As a result, iron works which produce products with coal are in difficulties. Accordingly, it is required a lot of research of using non-caking coal that is relatively low cost and has abundant reserves. Direct drying and indirect drying are two major methods of drying the coal. Recently, to minimize the needed calories and to save energy, using fluidbed or fluidizing method is a recent main trend of minimizing the size of the facility and maximizing energy efficiency. However there is also disadvantage such as increasing facility investment because of installing additional facilities in the latter part. In this study, we will have theoretical researches on the indirect drying method with heat exchange system which have been traditionally used. As a result it is expected to increase the efficiency of the facility operation.

  • PDF

Performance Characteristics according to the Outlet Impeller Blade Shape of a Centrifugal Blower (원심블로어 임펠러 토출 날개 형상에 따른 성능특성)

  • Lee, Jong-Sung;Jeon, Hyun-Jun;Jang, Choon-Man
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.6
    • /
    • pp.12-18
    • /
    • 2013
  • This paper presents the performance characteristics of a centrifugal blower using the design parameters of an impeller blade. Two design variables, the bending length from the blade trailing edge and bending angles of an impeller blade, are introduced to analyze the effects on the blower performance. Three-dimensional Navier-Stokes equations with shear stress transport turbulence model are introduced to analyze the performance and internal flow of the blower. Relatively good agreement between experimental measurements and numerical simulation at the design flow condition is obtained. Throughout present study, it is known that pressure increases as the bending length from the trailing edge and bending angle increase while efficiency decreases. But efficiency is decreased. Detailed flow field inside the centrifugal blower is also analyzed and compared.

Highly efficient phosphorescent polymer OLEDs fabricated by screen printing

  • Lee, D.H.;Choi, J.S.;Cho, S.M.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.694-697
    • /
    • 2007
  • We demonstrate the use of screen printing in the fabrication of highly efficient phosphorescent polymer organic-light-emitting devices (OLEDs) based on a green-emitting $Ir(ppy)_3$ and a host polymer PVK. We incorporate PBD in the polymer host as an electron-transporting dopant and ${\alpha}-NPD$ as a hole transporting dopant. The best screen printed single-layer device exhibits very high peak luminous efficiency of 63 cd/A at a relatively high operating voltage of 17.1 V at the luminance of $650\;cd/m^2$. We observed the highest luminance of $21,000\;Cd/m^2$ at 35V. Due to the high operating voltage, despite of the high peak luminous efficiency the peak power efficiency was found to be 12.2 lm/W at the luminance of $470\;cd/m^2$ (15.9 V).

  • PDF

Effect of Lighting Saving Using High Efficiency Reflector (고효율 반사갓을 이용한 등기구 저감효과)

  • Cho, Huyn-Kyung;Kim, Jae-Chul;Jung, Seung-Bock;Im, Sang-Kug
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.148-153
    • /
    • 2006
  • This paper analyzes the effect of the energy saving and evaluates the economics using High Efficiency lighting. About 18 percent (17,000GWh) of total power demands in Korea m consumed i]l the lighting field. There isa lot of energy potential that can be saved because the power demand isolwer relatively than the others parts. The existing lighting that its length and electric energy are 32[mm] and 40[w] can alternate with high efficiency lighting which its length and electric energy are 26[mm] and 32[w]. Two Lightings is measuring the illumination and the electric energy and then are analyzed into the effect of the lighting saving by measurement.

  • PDF

Effect of Cations on the open-Circuit Photovoltage and the Charge-Injection Efficiency of Dye-Sensitized Nanocrys-talline Rutile $TiO_2$ Films

  • Park, Nam Gyu;Jang, Sun Ho;Kim, Gang Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.10
    • /
    • pp.1047-1048
    • /
    • 2000
  • Dye-sensitized nanocrystalline rutile $TiO_2$ solar cells were prepared, and the influence of Li+ and 1,2-dimethyl-3-hexyl imidazolium ions in the electrolyte on the photovoltaic properties was compared. The electrolyte con-taining Li+ ions produced a lower open-circuit photovoltage than the electrolyte with 1,2-dimethyl-3-hexyl im-idazolium ions, suggesting that the adsorption of Li+ ions to the rutile $TiO_2$ surface causes a shift in the band edges toward more positive potentials. At the same time, both the short-circuit photocurrent and the maximum value of the incident-photon-current conversion efficiency (IPCE) of the electrolyte containing Li+ ions were relatively higher. Data analysis suggests that presence of adsorbed Li+ ions improves via the phenomenon of band-edge movement the charge-injection efficiency by altering both the energy and number of excited state levels of the dye that participate in electron injection.