• Title/Summary/Keyword: relative time study

Search Result 2,593, Processing Time 0.031 seconds

Estimation of Nursing Cost for Hemodialysis Using RBRVS(Resource Based Relative Value Scale);Severe Hemodialysis Patients (자원기준 상대가치를 이용한 혈액투석실 간호원가 산정;중증 대상자를 중심으로)

  • Kim, Moon-Sil;Han, Su-Jung;Kim, Jung-A;Kim, Ji-Hyun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.11 no.1
    • /
    • pp.33-44
    • /
    • 2005
  • Purpose: This study was aimed to estimate nursing cost for hemodialysis of tertiary hospitals using Resource Based Relative Value Scale(RVRBS). Method: First, we calculated nursing workload of the each hemodialysis-nursing behaviors compared with basic nursing behavior(check vital sign) for the most severe hemodialysis patients in general hospitals. Second, we measured each spent time according to each nursing behaviors. Third, we computed Resource Based Relative Value(RBRV) scores and nursing expenses of each 14 nursing behavior for hemodialysis. Finally, we estimated nursing cost of each hemodialysis-behavior for the most severe hemodialysis-patients in general hospitals. Result: The mean RBRV scores for each nursing behaviors were from 218.9 to 383.9 points. The highest RBRV socres were 383.9(Complication during hemodialysis). The Nursing behavior that spent the most time was "access the vascular( 31.7 minutes)". Nursing cost per hemodialysis for the patient with severe condition was estimated 63,455(won). Conclusion: Total average workload was 347.6 points and total spent time was 306.5 minutes for 14 hemodialysis nursing behaviors provided to severe patients. There were clear differences in nursing workload and cost according to patient's severity-mild, moderate and severe class.

  • PDF

The Study on the Atmospheric Corrosion Tests of Materials in Northeast Asia (동북 아시아 지역에서의 대기중 재료부식 시험에 관한 연구)

  • 김선태;임봉빈
    • Journal of Environmental Science International
    • /
    • v.7 no.3
    • /
    • pp.361-368
    • /
    • 1998
  • The structure such as building and cultural properties was composed of various materials like wood, metal and stone that have been utilized and exposed to air, wind and rain far a long time. However, because of their special characteristics as structure, collecting of samples that may involve their destruction cannot be permitted, ever for material analysis. Therefore, h order to study the Influence of atmospheric pollution on structure, atmospheric corrosion tests were achieved by making use of materials(bronze. ancient copper, copper, steel and marble) in field exposure tests. Atmospheric exposure sites are selected from places which are characterized by urban, rural, Industrial and marine enoronments In Northeast Asia. According to the results of atmospheric corrosion tests: The corrosion rates of Industrial states In china were more serious than other sampling sites. In the correlation of meteorological factors. wet hours was defiled as Intogeacted hours under that atmospheric temperature is above $0^{\circ}C$ and relative humidity in above 80% that has a great influence on corrosion tests of materials in case of a short time. The relative humidity was above about 75% that resulted in great increase of corrosion rates. In the esimation of corrosion rates between materials, corrosion rates of steel was about thirty times and decuple larger than that of other materials excluding marble in unshelterd exposure and In sheltered exposure.

  • PDF

A Comparative Study of Transistor and RC Pulse Generators for Micro-EDM of Tungsten Carbide

  • Jahan, Muhammad Pervej;Wong, Yoke San;Rahman, Mustafizur
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.3-10
    • /
    • 2008
  • Micro-electrical discharge machining (micro-EDM) is an effective method for machining all types of conductive materials regardless of hardness. Since micro-EDM is an electro-thermal process, the energy supplied by the pulse generator is an important factor in determining the effectiveness of the process. In this study, an investigation was conducted on the micro-EDM of tungsten carbide (WC) to compare the performance of transistor and resistance/capacitance (RC) pulse generators in obtaining the best quality micro-hole. The performance was measured by the machining time, material removal rate, relative tool wear ratio, surface quality, and dimensional accuracy. The RC generator was more suited for minimizing the pulse energy, which is a requirement for fabricating micro-parts. The smaller-sized debris formed by the low-discharge energy of RC micro-EDM could be easily flushed away from the machined zone, resulting in a surface free of burrs and resolidified molten metal. The RC generator also required much less time to obtain the same quality micro-hole in WC. Therefore, RC generators are better suited for fabricating micro-structures, producing good surface quality and better dimensional accuracy than the transistor generators, despite their higher relative tool wear ratio.

A Study on the Development of Adsorption-Desorption Systems Using Thermoelectric Devices for Improved Energy Efficiency (에너지 효율 향상을 위한 열전소자를 이용한 흡·탈착 시스템 개발 연구)

  • Jik-Su Yu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_2
    • /
    • pp.981-989
    • /
    • 2024
  • In recent years, there has been a growing focus on preserving the global environment and utilizing resources efficiently. The significance of energy conservation has led to the development of systems that recycle waste heat from factories and use eco-friendly refrigerants. This study aims to enhance the performance of adsorption-desorption systems using thermoelectric devices, which are known for their ability to convert temperature differences into electrical energy. The research focuses on improving the efficiency of these systems by integrating thermoelectric modules to cool the adsorption side and heat the desorption side, thus enhancing overall system performance. The experiments utilized a typical thermoelectric device and silica gel as the adsorbent. Key experimental parameters included varying the inlet air temperature and relative humidity on the desorption side. The results indicated that increasing the relative humidity of the inlet air on the desorption side significantly enhanced the overall mass transfer coefficient while reducing the completion time of the process. Similarly, higher inlet air temperatures led to an increase in the mass transfer coefficient and a decrease in process completion time. These findings suggest that optimizing the operational conditions of thermoelectric devices can substantially improve the performance of adsorption-desorption systems, offering potential benefits for applications in ventilation systems and other related fields.

Agricultural tractor roll over protective structure (ROPS) test using simplified ROPS model

  • Ryu-Gap Lim;Young-Sun Kang;Dae-Hyun Lee;Wan-Soo Kim;Jun-Ho Lee;Yong-Joo Kim
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.771-783
    • /
    • 2022
  • In this study, the feasibility of alternative tractor Roll Over Protective Structure (ROPS) designed to evaluate conditions required for testing was confirmed. In accordance with Organization for Economic Cooperation and Development (OECD) code 4, the required load energy of the tractor ROPS was determined. First, the tractor ROPS test was performed and a repeated test was performed using a simplified ROPS as an alternative tractor ROPS. The test procedure is first rearward, second lateral, and last forward based on ROPS. The load test device consists of a load cell that measures force and a LVDT that measures deformation. Precision was confirmed by calculating the relative standard deviation of the simplified ROPS repeated test. Accuracy was analyzed by calculating the mean relative error between the mean measured values in the simplified ROPS test and the tractor ROPS test. As a result, the relative standard deviation was less than 2.5% for force and 3.3% for maximum deformation overall, showed the highest precision in lateral load. The mean relative error value for force measured at the lateral load of simplified ROPS was 0.5%, showing the highest accuracy. In the front load test, the mean relative error of maximum deformation was 20.5%, showing the lowest accuracy. The mean relative error (MRE) was high in the forward load test was because of structural factors of the ROPS. The simplified ROPS model is expected to save money and time spent preparing tractors.

A Systematic Comparison of Time Use Instruments: Time Diary and Experience Sampling Method (생활시간 연구를 위한 측정도구의 비교 : 경험표집법과 시간일지)

  • Jeong, Jae-Ki
    • Survey Research
    • /
    • v.9 no.1
    • /
    • pp.43-68
    • /
    • 2008
  • This study compares two instruments for time use study: The time diary and the Experience Sampling Method (ESM), While previous studies show that the ESM and the full-diary are similar with respect to aggregate estimates, No previous study has examined the concordance rates of individual records from both instruments. Based on the subsamples who completed both instruments during the same time period from 500 family studies conducted by the Alfred P. Sloan Center on Parents, Children, and Work at the University of Chicago, we systematically compares the two instruments and evaluates their relative strengths. The results suggest that time diaries provide less biased time use estimates. and that compared to the time diary, the ESM provides a more detailed description of everyday life. The implications of further researches are discussed.

  • PDF

Influence of Time Stress on EEG Characteristics Related with Human Errors (시간 압박이 인간과오 관련 뇌파 특성에 미치는 영향)

  • Lim, Hyeon-Kyo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.83-90
    • /
    • 2011
  • It is well known that urgency resulted from time stress can be a great cause to industrial accidents. Therefore, time stress has been studied in the aspect of macroscopic view, namely industrial safety management, but has not been studied in microscopic view such as psychophysiological approach. Among diverse psychophysiological indices, Electroencephalogram(EEG) would be on of the most objective psychophysiological research technique on human errors though few research has been taken yet. This study aimed to get characteristics of human error while committing a simple arithmetic addition task by utilizing the power spectrum technique of EEG data. Each experiment was composed of 2 tasks under different condition - with and without time stress. As subjects, 5 young undergraduate students in their early twenties participated in this study. The results advocated a well-known fact that time stress downgrades the performance of human workers. However, correct answer rate and response time were not significantly influenced by time stress factor which might be explained by the constructural factor adopted in the present study. As in the previous studies, among various EEG-related measures, relative band power ratios of ${\alpha}$ and ${\beta}$ waves to sum of ${\alpha}$,${\beta}$,${\theta}$ wave powers, namely $P_{{\alpha}/({\alpha}+{\beta}+{\theta})}$ and $P_{{\beta}/({\alpha}+{\beta}+{\theta})}$ seemed to be the most effective measures to grasp variation of brain activities in time-stressed situation so that discussions were expanded about their variations.

A Study of Washing Conditions on Soil-release -Laundering P/C Fabric- (세탁조건이 세정 효과에 미치는 영향에 관한 연구 -P/C혼방직물을 중심으로-)

  • Nam Sang-woo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.1 s.26
    • /
    • pp.69-80
    • /
    • 1988
  • In this study, we have compared the relative importance of various washing condition affecting on soil release for P/C blended fabrics. P/C blended fabrics were soiled by the pad-dry method with aqueous and oily soil. The washing procedures of soiled samples were performed by Atlas Launder-Ometer with 27 wash conditions which are combinations of wash temp. wash time and detergent cone. The degree of soil-release was evaluated with CIE 1976 Lab color difference before and after washing. Multiple regression analysis was used to evaluate the optimum wash conditions and the relative importance of the factors providing maximum soilremoval.

  • PDF

Ecological resilience of soil oribatid mite communities after the fire disturbance

  • Kim, Ji Won;Jung, Chuleui
    • Journal of Ecology and Environment
    • /
    • v.36 no.2
    • /
    • pp.117-123
    • /
    • 2013
  • This study investigated the impact of the fire disturbance and the pattern of recovery of soil dwelling oribatid mite communities with respect to the resilience from the fire disturbance. Oribatid mites are important decomposer animals of plant debris in soil with the feeding habits of saprophagy and mycophagy. Massive wild fire reduced soil oribatid mite abundance and diversity. The impact varied relative to the intensity of the disturbance. The proportion of the species common to the non-disturbed natural site increased as the time after the disturbance elapsed, which implying some degree of naturalness occurring in reorganization phase of the oribatid mite community. From the sites with different degree of fire impact, we found higher diversity in intermediately disturbed sites than in severely disturbed or non-disturbed site, supporting the intermediate disturbance hypothesis. Also this study showed that with differential degree of disturbance plots, resilience pattern after the disturbance can be explored even with shorter period research relative to the ecological succession of community.

A study on the performance of variable damper type suspension for tracked vehicle (가변댐퍼식 궤도차량용 현수장치의 성능에 관한 연구)

  • 이재순;김승무
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.3 no.2
    • /
    • pp.34-42
    • /
    • 1981
  • The feasibility of using fluidic components for improving certain performance characteristics of the suspension systems for tracked vehicle is investigated. This study describes three variable damping systems for which the damping coefficients are function of relative velocity and absolute a of the vehicle body. Through the comparison analysis between constant damping coefficient damper and each of variable dampers. the followings were found: (1)Fluidic Diode Damper gave less accelerations, (2)Both Fluidic Diode Damper and Relative Velocity Damper gave the less time for which the wheel is off the ground, (3) At low vehicle velocity Fluidic Diode Damper gave low energy dissipation rate, while at high vehicle velocity Turbulence Accelerometer Damper gave low energy dissipation rate.

  • PDF