• Title/Summary/Keyword: relative method

Search Result 6,624, Processing Time 0.043 seconds

Applicability of the HPLC Method for the Estimation of Octanol/water Partition Coefficient to Pesticides of Domestic Use (국내 사용 농약을 대상으로 한 HPLC 방법에 의한 옥탄올/물 분배계수 추정법의 적용성 검토)

  • Kim, Kyun;Kwon, Jin-Wook;Kim, Yong-Hwa
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.4
    • /
    • pp.189-196
    • /
    • 2001
  • Octanol/water partition coefficients of 52 chemicals were calculated using RP-HPLC estimation method and predicted by computer program, PCHEM. The result showed relationship between literature values and RP-HPLC observed values (relative coefficient r$^2$=0.916), but the relationship of PCHEM values with literature values was lower than RP-HPLC value (relative coefficient r$^2$=0.795). The average difference in partition coefficient between the RP-HPLC method and flask-shaking method was log Kow=0.54, while the average difference between the values predicted form the computer program and flask- shaking method was log Kow = 0.36 Compared to octanol/water partition coefficients by 3 methods (Flask-shaking, RP-HPLC, computer prediction), the octanol/water partition coefficient values based on the flask-shaking method were very similar to the literature values, while the octanol/water partition coefficient values by RP-HPLC method without to consider the dead time, and computer prediction values did not significantly differ with the literature values.

  • PDF

Vision-based Guidance for Loitering over a Target

  • Park, Sanghyuk
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.366-377
    • /
    • 2016
  • This paper presents a vision-based guidance method that allows a fixed-wing aircraft to orbit around a target at a given radius. The guidance method uses a simple formula that regulates a relative side-bearing angle estimated by a vision system. The global asymptotic stability of the associated guidance law is demonstrated, and a linear analysis is performed to facilitate the proper selection of the relevant control parameters. A flight experiment is presented to demonstrate the feasibility and performance of the proposed guidance method.

Relative Survival of Breast Cancer Patients in Iran

  • Kasaeian, Amir;Mosavi-Jarrahi, Alireza;Abadi, Alireza;Mahmoodi, Mahmood;Mehrabi, Yadollah;Mohammad, Kazem;Eshraghian, Mohammad Reza;Zare, Ali
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5853-5858
    • /
    • 2015
  • Background: The survival rate reflecting prognosis of breast cancer patients is usually estimated based on crude survival methods such as observed and cause-specific. In situations where data are based on population-cancer registries, this method may produce biased estimations. This study therefore aimed to estimate the net survival of breast cancer based on relative survival. Materials and Methods: Data for 622 breast cancer patients diagnosed at the Iran Cancer Institute during 1990-95 and tracked till the end of 2000 were analyzed. For estimation of relative survival, Ederer's second method and SAS (9.1) and STATA (11) software were used. Results: Threeyear relative survivals of 85%, 90%, 80% and 67% were observed for age groups 15-44, 55-59, 60-74, and 75+years-old, respectively. A relative survival of approximately one was observed for two subsequent years for age-group 45-59 years-old. A value greater than one for two subsequent years of follow-up was observed in the age-group 60-74 years-old. Conclusions: Tracking the diagnosis of breast cancer, the relative survival decreases as we go to higher age-groups. It is also perceived that through follow-up, relative survival first decreased and then increased a little. The statistical cure point is acceptable for age group 45-59 years-old while for age-groups 15-44 and 60-74 years old is a sign of low quality data for some follow-up intervals.

Analysis of the Internal Reliability in Relative Orientation and Independent Model Method (상호표정 및 독립모델법에서의 내적신뢰성 분석)

  • 양인태
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.5 no.1
    • /
    • pp.59-65
    • /
    • 1987
  • This paper presented the procedures for detecting gross errors, and described the influence of the number and distribution of points on the internal reliability in photogrammetric adjustment, such as relative orientation and independent model method. The use of the standard six points for relative orientation and the regular four points for independent model method result in low internal reliability. With such a distribution, gross erors in measured points might not be detected But using cluster of double or triple points instead of individual point, internal reliability improves remarkably.

  • PDF

Auditory Perception Experiment on Attribute of Road Traffic Noise Causing Annoyance with Identical Linear Sound Pressure Level (동일한 선형 음압 레벨의 도로교통소음의 성가심 유발 인자에 관한 연구)

  • An, Jang-Ho;Schang, Seo-Il;Ko, J.H.;Chun, Hyung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.641-648
    • /
    • 2006
  • This study investigates which sound quality indices except SPL raise annoyance response. For investigation, auditory perception experiments for road traffic noise with identical linear SPL were performed by Paired Comparison Method. The numerical results of a Paired Comparison experiment express relative preference about annoyance. So that these relative preference scores are to be correlated to sound quality indices, which are absolute, a transformation is required to go from the relative domain to an absolute and linear scale of preference. The results of the transformation will be the 'merit values,' which quantifies the annoyance(in this case) of the road traffic noise on a linear scale. Using multiple regression, a formula is established that can calculate predicted merit values. Furthermore, This investigation offers a method selecting sound samples that represent various sound quality indices values to use experiment.

  • PDF

RESEARCH FOR BOND STRESS-RELATIVE SLIP RELATIONSHIP (부착응력-상대슬립 관계에 대한 연구)

  • 고원준;김진호;서봉원;박선규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.221-226
    • /
    • 2002
  • This paper deals with the estimation of the bond stress based on experimental data that were tensed by axial force on both sides. It is certificated that the concrete stress condition clearly affects the bond-slip relationship. The proposed method utilizes the conventional bond-slip theories as well as the characteristics of deformed reinforcement and concrete cross-sectional area. An analytical equation for the estimation of the bond stress is formulated as the function of non-dimensional factors (e.g. bond stress, relative slip, etc.). The validity, accuracy and efficiency of the proposed method are established by comparing the analytical results with the experimental data of Ikki (1996, 1999) and the representative bond stress equations of Shima (1987). The analytical results presented in this paper indicate that the proposed method can be effectively estimated the bond stress-relative slip relationship.

  • PDF

Preparation of Macroporous Pellet from Industrial Waste Flyash by Foaming Method

  • Park, Jai-Koo;Kim, Hyun-Jung
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.638-643
    • /
    • 2001
  • Macroporous pellets were prepared from industrial waste flyash by foaming method. The surface and inside of flyash pellets, the shape was almost spherical and the average size was about 3 mm, were composed of the spherical pores interconnected through windows. The controlling of pellet size was conducted with solid loading. The flyash pellets with different relative density were characterized for porosity, average pore size, and specific surface area. As results, most physical properties had a tendency to increase as relative density decreased - extension ratio increased. The correlation between relative density and other properties was inspected through microstructural features evaluated by SEM. As a result, high porosity and high specific surface area were estimated to result from the superior connectivity between pores.

  • PDF

A Study on Design of Barrel Cam for Automatic Bulb Production Machine (전구 자동화 생산기계용 바렐 캠의 형상설계에 관한 연구)

  • Kim, Jong-Su;Yun, Ho-Eop
    • 연구논문집
    • /
    • s.33
    • /
    • pp.89-97
    • /
    • 2003
  • A barrel cam is used as a very important part of an index drive unit. The index drive unit must have an intermittent-rotational motion. The barrel typed cam and roller gear mechanism has the advantages of high reliability to perform a prescribed motion of a follower. This paper proposes a new method for the shape design of the barrel cam and also a CAD program is developed by using the proposed method. As defined in this paper, the relative velocity method for the shape design calculates the relative velocity of the follower versus cam at a center of roller, and then detemines a contact point by using the geometric relationships and the kinematic constraints, where the direction of the relative velocity must be parallel to a common tangential line at the contact point of two independent bodies, i.e. the cam and the follower. Then, the shape of the cam is defined by the coordinate transformation of the trace of the contact points. This paper presents shape design of the barrel cam in order to prove the accuracy of the proposed methods

  • PDF

Relative Measurement of Differential Electrode Impedance for Home Healthcare Device (Home Healthcare 장치를 위한 차동 전극 임피던스의 상대적인 측정)

  • Woo, Y.J.;Yoo, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.469-470
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

  • PDF

Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager

  • Yang, Jeong-Gyu;Park, Hee-Duk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.11
    • /
    • pp.1-7
    • /
    • 2016
  • In this paper, we proposed real-time relative radiometric calibration processing method for SWIR(Short Wavelength Infra-Red) sensor using 'Hyper-Spectral Imager'. Until now domestic research for Hyper-Spectral Imager has been performing with foreign sensor device. So we have been studying hyper spectral sensor device to meet domestic requirement, especially military purpose. To improve detection & identify capability in 'Hyper-Spectral Imager', it is necessary to expend sensing wavelength from visual and NIR(Near Infra-Red) to SWIR. We aimed to design real-time processor for SWIR sensor which can control the sensor ROIC(Read-Out IC) and process calibrate the image. To build Hyper-Spectral sensor device, we will review the SWIR sensor and its signal processing board. And we will analyze relative radiometric calibration processing method and result. We will explain several SWIR sensors, our target sensor and its control method, steps for acquisition of reference images and processing result.