• Title/Summary/Keyword: relative humidity (RH)

Search Result 345, Processing Time 0.023 seconds

Changes in the Amount of PEG Free-Flowing Back from PEG-Treated Waterlogged Archaeological Wood and the Compressive Strength According to Relative Humidity Conditions (습도조건에 따른 PEG 처리 수침고목재의 PEG 용출량 및 압축강도 변화)

  • Jo, Ah Hyeon;Lee, Kwang-Hee;Choi, Tae-Ho;Go, In Hee;Seo, Jeong-Wook
    • Journal of Conservation Science
    • /
    • v.36 no.3
    • /
    • pp.225-235
    • /
    • 2020
  • The present study aimed to monitor changes in the amount of PEG free-flowing back from PEG-treated woods and compressive strength changes with change in relative humidity from 90% to 30%. The change in the relative humidity was done 3 times. For the current study, water-logged wood (Prinus group) was used and the wooden blocks cut out of it were subjected to 3 different impregnation methods combined with different drying conditions as follows: 1) impregnating with 80% PEG#4000 followed by drying in nature (hereafter PEG80), 2) impregnating with 40% PEG#4000 and then drying in vacuum freeze drying equipment (hereafter PEG40), and 3) impregnating with 40% PEG#4000 in t-butanol, followed by drying in the vacuum freeze drying equipment (hereafter TB40). It was verified that most of the PEG was free-flowing back from the PEG-treated woods; however, a small amount of left PEG was observed on the lumen surface. The amount of PEG free-flowing back from the PEG-treated woods increased whenever the relative humidity changes from 90% to 30%. The compressive strengths of PEG80 and TB40 were increased whenever the relative humidity changed from 90% to 30%, whereas PEG40 decreased. The current study showed how to control the relative humidity to effectively manage PEG-treated waterlogged woods.

A Study on Metal Oxide based Humidity Sensor with Excellent Humidity Sensing Characteristics (감습특성이 우수한 금속산화물계 습도센서 연구)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1982-1988
    • /
    • 2009
  • $TiO_2$ films are fabricated using silk printing method. Heat treatment temperature of films is 600[$^{\circ}C$]. From the analysis of microstructure, grain size of $TiO_2$ films is about $0.2{\sim}0.3[{\mu}m]$. Thickness of films is 30.19[${\mu}m$] and surface uniformity of films is good. From the analysis of crystalline structure, $TiO_2$ films transform anatase phase to rutile phase. Capacitance of films increases according to increase relative humidity and decrease measuring frequency. Hysteresis characteristics of capacitance and impedance are best at 45[%RH] and 75[%RH] respectively. Impedance of films increases according to decrease measuring frequency.

Comparison of Dynamic Sorption and Hygroexpansion of Wood by Different Cyclic Hygrothermal Changing Effects

  • Yang, Tiantian;Ma, Erni
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.191-203
    • /
    • 2016
  • To investigate the dynamic sorptive and hygroexpansive behaviors of wood by different cyclic hygrothermal changing effects, poplar (populus euramericana Cv.) specimens, were exposed to dynamic sorption processes where relative humidity (RH) and temperature changed simultaneously in sinusoidal waves at 75-45% and $5-35^{\circ}C$ (condition A) and where RH changed sinusoidally at 75-45% but temperature was controlled at $20^{\circ}C$ (condition B), both for three cyclic periods of 1, 6, and 24 h. Moisture and dimensional changes measured during the cycling gave the following results: Moisture and transverse dimensional changes were generally sinusoidal. Moisture and dimensional amplitude increased with increasing cyclic period but all were lower for thicker specimens. The amplitude ratio of condition A to condition B ranged from 1.0 to 1.6 with the maximum value of 1.57 occurring at the shortest cyclic period, not as much as expected. T/R increased as cyclic period increased or specimen thickness decreased. T/R from condition B was weaker than that from condition A. Sorption and swelling hysteresis existed in both conditions. Sorption hysteresis was negatively related to cyclic period but in positive correlation with specimen thickness. Sorption hysteresis was found more obvious in condition B, while moisture sorption coefficient and humidity expansion coefficient showed the opposite results.

Humidity Sensing Properties of Iodine-doped PPA Thin Films (Iodine-doped PPA 박막의 감습특성)

  • Min, Nam-Ki;Kang, Hyun-Sik;Kim, Tae-Yoon;Kim, Suk-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1561-1563
    • /
    • 1998
  • A capacitive humidity sensor is used as a test device to characterize the performance of iodine doped polyphenylacetylene(PPA) thin films in relative humidity sensing application In comparison with undoped PPA thin films. the iodine doped PPA films showed higher sensitivity(0.19pF/%RH), better linearity(4.2%FS), much lower hysteresis and lower temperature coefficients(0.043 $\sim$ 0.067pF/$^{\circ}C$) over a wide range of relative humidity.

  • PDF

Capacitive Humidity Sensors using lodine-doped Polyphenylacetylene Thin Films (요오드가 도우핑된 폴리페닐아세틸렌 박막을 이용한 정전용량형 습도센서)

  • Min, Nam-Ki;Jin, Joon-Hyung;Kim, Tae-Yoon;Hong, Suk-In
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.6
    • /
    • pp.335-340
    • /
    • 2000
  • We report the results of a preliminary investigation on capacitive humidity sensors using iodine-doped polyphenylacetylene(PPA) thin films. PPA was prepared from phenylacetylene(PA), chemically doped with iodine, and characterized by DSC, $^1H$-NMR and FTIR spectra. The iodine-doped PPA sensors showed a sensitivity of 0.20pF/%RH, a linearity of 3.8%FS, a negligible hysteresis, and a low temperature coefficients of $0.043~0.067pF/^{\circ}C$ over a wide range of relative humidity. These results are expected to open up the possibility of iodine-doped PPA thin films as relative humidity sensors.

  • PDF

Real-Time Micro-Weather Factors of Growing Field to the Epidemics of Rice Blast (벼 도열병 Epidemics에 미치는 재배 포장 실황기상 요인)

  • Kwon, Jae-Oun;Lee, Soon-Gu
    • Research in Plant Disease
    • /
    • v.8 no.4
    • /
    • pp.199-206
    • /
    • 2002
  • It was investigated on the relationship of the rice blast epidemics and the real-time meteorological factors, at the experimental paddy field in 1997. Weather factors(temperature, relative humidity, irradiation, precipitation, the direction of wind, wind speed, soil temperature and leaf-wetness, etc) were measured by using the automated weather station. The most influenced weather factor to blast epidemics, was the average max-temp($R^2$= 0.95) during 10 days before leaf blast epidemics, while the least thing was wind speed($R^2$= 0.24). The most potential weather factors correlated with the blast epidemics were T-ave(average temperature), T-max(maximum temperature), RH(Relative Humidity) and RD(Relative Humidity > 90% hrs). A statistics model(the regression equation) of the blast epidemics with the potential weather factors, was established as tallows ; Y = -3410.91 - 23.91 $\times$ T-ave + 28.56 $\times$ T-max + 41.0 $\times$ RH - 3.75 $\times$ RD, ($R^2$= 0.99). (T-ave >= 19$^{\circ}C$, T-max - T-ave >= 5.2$^{\circ}C$ and RH% >= 90.4%). According to the fitness test($\chi$$^2$) of the model, the observed blast disease severity was quite close to those expected.

Effects of environmental parameters on chloride-induced stress corrosion cracking behavior of austenitic stainless steel welds for dry storage canister application

  • Seunghyun Kim;Gidong Kim;Chan Kyu Kim;Sang-Woo Song
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.317-327
    • /
    • 2024
  • This study investigated the chloride-induced stress corrosion cracking (CISCC) behavior expected to occur in welds of austenitic stainless steel, which are considered candidate materials for dry storage containers for spent nuclear fuel. The behavior was studied by varying temperature, relative humidity (RH), and chloride concentration. 304L-ER308L welded plates were processed into U-bend specimens and exposed to a cyclic corrosion chamber for 12 weeks. The CISCC behavior was then analyzed using electron microscopy. A previous study by the authors confirmed that CISCC occurred in ER308L at 60 ℃, 30% RH, and 0.6 M NaCl via selective corrosion of δ-ferrite. When the temperature was lowered from 60 ℃ to 50 ℃, CISCC still occurred. However, when the humidity was reduced to 20% RH, CISCC did not happen. This can be attributed to the retardation of the deliquescence of NaCl at lower humidity, which was insufficient to promote CISCC. Furthermore, increased chloride concentration to 1.0 M resulted in the absence of CISCC and widespread surface corrosion with severe pitting corrosion because of the increase in thin film thickness.

Evaluation of thermal comfort and cooling loads for a multistory building

  • Lykartsis, Athanasios;B-Jahromi, Ali;Mylona, Anastasia
    • Advances in Energy Research
    • /
    • v.5 no.1
    • /
    • pp.65-77
    • /
    • 2017
  • The latest UK Climate Projections (UKCP09) show that mean daily temperatures will increase everywhere in the United Kingdom. This will significantly affect the thermal and energy performance of the current building stock. This study examines an institutional fully glazed building and looks into the changes in the cooling loads and thermal comfort of the occupants during the occupied hours of the non-heating period. Furthermore, it investigates the effect of relative humidity (RH) on thermal comfort. The Design Summer Year (DSY) 2003 for London Heathrow has been used as a baseline for this study and the DSY 2050s High Emissions scenario was used to examine the performance of the building under future weather conditions. Results show a 21% increase of the cooling loads between the two examined scenarios. Thermal comfort appears to be slightly improved during the months of May and September and marginally worsen during the summer months. Results of the simulation show that a relative humidity control at 40% can improve the thermal comfort for 53% of the occupied hours. A comparison of the thermal comfort performance during the hottest week of the year, shows that when the relative humidity control is applied thermal comfort performance of the 2050s is similar or better compared to the thermal comfort performance under the baseline.

Equilibrium Moisture Content of Korean Ginseng (인삼(人蔘)의 평형함수율(平衡含水率)에 관(關)한 연구(硏究))

  • Choi, B.M.;Lee, J.H.;Park, S.J.;Kim, C.S.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.247-259
    • /
    • 1992
  • This study intended to measure the desorption and adsorption EMC of four years old Peeled ginseng, Unpeeled ginseng and Taegeuk ginseng under various conditions$20^{\circ}C$, $30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$) and five levels of relative humidity from 31% to 88%) by the static method. Four widely used EMC models were selected and evaluated. Also the empirical model was evaluated. The results are summarized as follows ; 1) EMC difference between ginseng size was not found but found between ginseng species. EMC difference between Peeled ginseng and Unpeeled ginseng was not found. EMC of Peeled ginseng and Unpeeled ginseng was higher than that of Taegeuk ginseng. 2) The hysteresis, which is difference between desorption and adsorption EMC, was found. Desorption EMC was higher than adsorption EMC. The hysteresis at the same temperature decreased as relative humidity increase. The difference of hysteresis between Peeled ginseng and Unpeeled ginseng was not large and the hysteresis of Taegeuk ginseng was smaller than those of other species. 3) Among the selected models, Henderson model was the best to predict the adsorption EMC of White ginseng(Peeled and Unpeeled ginseng), and Oswin model was the best to predict the desorption EMC of White ginseng and the desorption and adsorption EMC of Taegeuk ginseng. The models are as follows ; (a) White ginseng(Peeled and Unpeeled ginseng) ${\circ}$ Desorption EMC(Oswin model) : $$M=(0.1272-0.0007420T){\cdot}[RH/(1-RH)]^{(0.4164+0.001368T)}$$ ${\circ}$ Adsorption(Henderson model) : $$1-RH={\exp}[-0.0003480T_k\;{M_o}^{0.9231}]$$ (b) Taegeuk ginseng ${\circ}$ Desorption EMC(Oswin model) : $$M=(0.1051-0.0008439T)[RH/(1-RH)]^{(0.4553+0.003425T)}$$ ${\circ}$ Adsorption EMC(Oswin model) : $$M=(0.08247-0.0007559T){\cdot}[RH/(1-RH)]^{(0.5760+0.005540T)}$$ 4) The developed empirical models could predict the desorption and adsorption EMC for White and Taegeuk ginseng more precisely than selected models. The empirical models are as follows ; (a) White ginseng(Peeled and Unpeeled ginseng) ${\circ}$ Desorption EMC : $$M=0.124-0.000647T-0.216RH+0.373RH^2$$ ${\circ}$ Adsorption EMC : $$M=0.0879-0.000663T-0.197RH+0.399RH^2$$. (b) Taegeuk ginseng ${\circ}$ Desorption EMC : $$M=0.159-0.000728T-0.429RH+0.565RH^2$$ ${\circ}$ Adsorption EMC : $$M=0.123-0.000662T-0.384RH+0.555RH^2$$.

  • PDF

Occurrence of White Rust and Growth of Chrysanthemum 'Baekma' by Control of Relative Humidity with Night Ventilation and Heating in the Greenhouse (국화 '백마'의 시설재배에서 야간 환기와 난방에 의한 상대습도 조절에 따른 흰녹병 발생과 생육)

  • Yoo, Yong Kweon;Roh, Yong Seung;Nam, Byung Cheol
    • Horticultural Science & Technology
    • /
    • v.34 no.6
    • /
    • pp.845-859
    • /
    • 2016
  • This study was conducted to examine the effect of nighttime ventilation and heating on changes in temperature and humidity, the occurrence of white rust, and growth of standard chrysanthemum (Dendranthema grandiflorum) 'Baekma' in a greenhouse. For the ventilation treatments, the mean nighttime humidity in the control greenhouse, which had a closed side window, was higher (94.5%), but the humidity in the natural and natural+fan ventilation treatments was lower (74.3% and 72.8%, respectively). The rate of occurrence of white rust at 34 days after treatment was 100, 98.3, 75.6, and 43.3% for the control, fan ventilation, natural ventilation, and natural+fan ventilation treatments, respectively. The number of infected leaves and telia were the lowest in the natural+fan ventilation treatment compared with the other treatments. The growth of the chrysanthemum 'Baekma' was significantly suppressed in the control because of the occurrence of white rust and high humidity, while plant height, number of leaves, stem diameter, and fresh weight were the greatest in the natural+fan ventilation treatment. For the heating treatments, the mean nighttime temperature of the control (RH 95% heating), which was heating and held at 95% humidity, was $18.4^{\circ}C$, while the temperature of the heating treatment, which was held at 70% relative humidity (RH 70% heating) was $25.8^{\circ}C$. The rate of occurrence of white rust (34.4%), number of infected leaves (0.9), and telia (1.0) were the lowest in the RH 70% heating treatment compared with the other heating conditions. Also, the RH 70% heating treatment showed the best growth in terms of plant height, stem diameter, number of leaves, and fresh weight. Therefore, the natural+fan ventilation and RH 70% heating treatments were effective for the control of white rust and the growth of standard chrysanthemum 'Baekma' in a greenhouse.