• 제목/요약/키워드: relative fluorescence intensity

검색결과 46건 처리시간 0.025초

Changes in Hydrophobic Surface of Collagen by Chondroitin Sulfate : Fluorescence Intensity Measurements with Bis-ANS as the Probe

  • Kim, Sung-Koo
    • 한국식품영양과학회지
    • /
    • 제24권3호
    • /
    • pp.446-453
    • /
    • 1995
  • The improtant components of extracellular matrix(ECM) are collagen and chondroitin sulfate. The hydrophobic surface of collagen is one of the determining factors of diameter of collagen fiber and also is closely related to the aging phenomena. The controlling mechanism of the diameter of collagen fiber influenced by the interaction with chondroitin sulfate was evaluated using bis-ANS as a hydrophobic probe. Hydrophobic surface area of collagen molecule shielded by chondroitin sulfate was evaluated. Relative fluorescence intensity of collagen in thepresence of chondroitin sulfate was measured using bis-ANS as a hydrophobic probe. The fluorescence intensity decreased with the increase in chondroitin sulfate up to 3.8 chondroitin sulfate/collagen(mole/mole). Further increase in the ratio of chondroitin sulfate to collagen did not change the fluorescence intensity. Similar changes in the relative fluorescence intensity were observed for both rat tail and lathyrific rat skin collagen. The fluorescence intensity indicated by the binding between bis-ANS and hydrophobic sites of collagen was pH dependent, and the shielding effect of collagen-chondroitin sulfate interaction could not be detected at pH above 6.0. This is probably due to the charge repulsions caused by negative charged collagen molecules at higher pH.

  • PDF

KrF 레이저를 이용한 희박연소화염과 매연화염에서의 NO계측 (NO measurements in lean and soot flame using KrF laser)

  • 손성민;고동섭;이중재;오승묵;강건용;김종욱
    • 한국광학회지
    • /
    • 제12권3호
    • /
    • pp.177-183
    • /
    • 2001
  • KrF 레이저를 여기광원으로 사용하여 희박연소화염과 매연화염에서 각각 청색편이된 NO형광 신호를 측정하였다. 두 화염에 대해서 여기광의 세기와 NO 첨가량에 따른 NO 신호와 배경잡음의 세기를 계측하고 그 결과를 정성적으로 분석하였다. 또한 희박연소화염에서 위치에 따른 NO 신호의 세기도 관측하였다.

  • PDF

하치조신경 절단 후 흰쥐 삼차신경절에서 VIP-IR의 변화 (VIP IMMUNOREACTIVITY IN THE RAT TRIGEMINAL GANGLION AFTER INFERIOR ALVEOLAR NERVE AXOTOMY)

  • 김흥중;박주철;김현섭;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.225-234
    • /
    • 2000
  • The purpose of this study was to investigate the distribution and fluorescene intensity of vasoactive intestinal polypeptide(VIP) immunoreactive cells in rat trigeminal ganglion after inferior alveolar nerve axotomy. The animals were divided into normal and two experimental groups. The experimental animals were sacrificed at 14th and 28th day after inferior alveolar nerve axotomy. The trigeminal ganglion was removed and immersed in the 4% paraformaldehyde-0.2% picric acid in 0.1M phosphate buffer. Serial frozon sections about $16{\mu}m$ in thickness were cut with a cryostat. The immunofluorescence staining was performed. The rabbit anti-VIP(1 : 8,000) was used as primary antibody and fluorescene isothiocynate(FITC)-conjugated anti-rabbit IgG(1 : 80) as secondary antibody. The slides were observed under confocal laser scanning microscope. Three-dimensional images were constructed from 9 serial images(each $1{\mu}m$ in thickness) made by automatic optical sectioning. Unprocessed optical sections were obtained and stored on a optical disk. Color picture were printed by a video copy processor. The results were as follows; 1. The appearance of VIP immunoreactive cells in the mandibular part of trigeminal ganglion was 8.79${\pm}$1.99% in normal group and 39.16${\pm}$5.62% in 14 days, 16.25${\pm}$2.39% in 28 days after inferior alveolar nerve axotomy groups. 2. The relative fluorescence intensity of VIP immunoreactive cell bodies in the mandibular part of trigeminal ganglion was 134.40${\pm}$10.39 in normal group and 192.88${\pm}$14.06 in 14 days, 143.10${\pm}$5.02 in 28 days after nerve axotomy groups. Therefore, the relative fluorescence intensity of 14 days after nerve axotomy group was 43.3% higher than intensity of normal group. 3. In optical single section analysis of VIP immunoreactive cell bodies, white cell bodies(moderate fluorescence intensity) were the most abundant in normal and 28 days after nerve axotomy groups. Whereas, in 14 days after nerve axotomy group, red cell bodies(high fluorescence intensity) were the most abundant. 4. In optical serial section analysis of VIP immunoreactive cell bodies, red cell bodies(high fluorescence intensity) were observed in a part of the 9 sections of normal and 24 days after nerve axotomy groups. Whereas, red cell bodies were observed in all of the 9 sections of 14 days after nerve axotomy group. 5. The results indicates that number and fluorescence intensity of VIP immunoreactive cells were increased in the mandibular part of trigeminal ganglion following inferior alveolar nerve axotomy.

  • PDF

Absorption and Fluorescence Spectra of Dy(Ⅲ) Complexes with Some Terdentate Ligands

  • 정승희
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권6호
    • /
    • pp.650-654
    • /
    • 1992
  • Absorption and fluorescence spectra are reported for four different 1 : 3 $Dy^{3+}$ : ligand systems in aqueous solution under mild alkaline pH conditions. The ligands included in this study are oxidiacetate, dipicolinate, iminodiacetate and methyliminodiacetate. The oscillator strengths for the 4f→4f multiplet-to-multiplet transitions are empirically determined from the absorption spectra and the intensity parameters ${\Omega}_{\lambda}$}(${\lambda}$ = 2, 4, 6) for the systems are also obtained by applying the Judd-Ofelt theorem to the observed oscillator strengths. The values of the intensity parameters for the systems are compared and discussed in terms of ligand structural properties to investigate how the intensity parameters can response to the minor changes in the ligand environment. In addition, the relative oscillator strengths for fluorescence are evaluated and compared to the results obtained from absorption spectra.

안트라센이 포함된 새로운 호스트 화합물의 합성과 물성 (Synthesis and Fluorescent Properties of New Host Compound Containing Anthracene Moiety)

  • 장승현
    • 한국환경과학회지
    • /
    • 제17권12호
    • /
    • pp.1373-1380
    • /
    • 2008
  • Anthracene appended new host compounds have been synthesized by imine reaction. Fluorescent open chain host compounds Trisanthryl-tris(2-aminoethyl)imine 1 was synthesized from the reaction of tris(2-aminoethyl)amine and anthracene-9-carboxaldehyde in EtOH. Tris-10-chloroanthryl-tris(2-aminoethyl)imine 2 was synthesized from tris(2-aminoethyl)amine and 10-chloro-9-anthraldehyde in EtOH. The structures of all reaction product were identified by $^1H$ NMR, $^{13}C$ NMR, GC/MS, FAB Mass, IR spectrum and DSC. Cation complexation behavior was investigated by fluorescence spectroscopy measurements. The capability of transition metals cation recognition between fluorescent open chain host compound 1, 2 were investigated with $Co^{2+},\;Ni^{2+}\;and\;Cu^{2+}$. The fluorescence intensity was increased by host compounds corresponding guest cations. The relative order of fluorescence intensity changes were $Co^{2+}>Cu^{2+}>Ni^{2+}$. Compound 2 is very sensitive fluorescent sensor of $Co^{2+}$ ion.

한라산 구상나무 잎의 엽록소형광의 일변화와 계절적 변화 (Diurnal and Seasonal Variation of Chlorophyll Fluorescence from Korean Fir Plants on Mt. Halla)

  • 오순자;고정군;김응식;오문유;고석찬
    • 환경생물
    • /
    • 제19권1호
    • /
    • pp.43-48
    • /
    • 2001
  • 구상나무 침엽의 엽록소형광과 생육지의 환경요인의 일변화를 계절별로 조사하여 환경요인의 변화에 따른 구상나무의 환경 적응성을 규명하였다. 광계 II의 광화학적 효율, 즉 Fv/Fm은 겨울에는 0.19-0.36으로 매우 낮은데 반하여 여름에는 0.8-0.86으로 높았다. 낮시간의 Fv/Fm이 겨울에는 아침, 저녁보다 상대적으로 높아서 겨울철 한낮의 환경조건이 구상나무 잎의 광합성기구에 우호적으로 작용을 하는 것으로 판단된다. 여름에는 낮시간에 광억제가 다소 일어나지만 Fv/Fm이 전반적으로 높아 낮시간의 환경 조건이 구상나무에 광피해를 야기하지는 않는 것으로. 해석되었다. 비광화학적 엽록소형광 소멸 능력, 즉 NPQ는 겨울에는 0-0.01로 밤과 낮의 차이가 없이 매우 낮았고, 여름에는 낮시간에 0.76으로 높았다. 따라서 구상나무는 여름철 환경 스트레스로부터 광계 II를 보호하는 조절 기구가 잘 발달한 것으로 판단되었다. 겨울에는 Fv/Fm이 온도, 광량, 상대습도와 모두 정의 상관관계를 보였으나 NPQ는 환경요인 모두와 상관성이 없는 것으로 나타났다. 여름에는 Fv/Fm이 온도와 광량과는 음의 상관관계를 나타낸 반면에 상대습도와는 정의 상관관계를 보였다. 따라서 구상나무 생육지의 조건하에서 겨울에는 온도, 광량, 상대습도의 증가는 모두 광합성 효율을 증가시키는 반면에 여름에는 높은 온도와 광량이 광억제를 야기할 수 있는 것으로 사료된다.

  • PDF

Acridine Fluorescence Behaviors in Different Polymeric Microenvironments Directed by C2-Proton-Acidity of Imidazolium-Based Ionic Liquids

  • Ji, Myoung-Jin;Kim, Jong-Gyu;Shin, Ueon-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권8호
    • /
    • pp.2489-2493
    • /
    • 2012
  • A new fluorescent system (acridine/RTIL hybrid gel) confined in the 3D micro-structure of a poly(lactic acid) membrane were prepared from 1-butyl-3-methylimidazolium-based ionic liquids ([bmim]X (X = $SbF_6$, $NTf_2$, Cl); RTILs), poly(lactic acid) (PLA), and acridine via the sol-gel route. SEM images showed that, in the presence of [bmim]$SbF_6$ and [bmim]$NTf_2$, 3D-ly paticulated structures were created inside the PLA membranes and acridine/RTIL hybrid gels were confined in gabs of particulates. However, the use of [bmim]Cl induced the formation of a 3D-ly porous structure containing the hybrid gel of acridine/[bmimCl in the micropores. The three fluorescent systems exhibited different fluorescence behaviors (fluorescence maximum and intensity) depending on the C2-H acidity scale of the RTILs (or their anion type). Acridine gels hybridized with [bmim]$SbF_6$ and [bmim]$NTf_2$ showed blue fluorescence with relative high intensity, whereas the hybrid gel with [bmim]Cl exhibited almost no fluorescence under dry conditions. However, the acridine/[bmim]Cl hybrid system in the micro-porous PLA membrane started to emit fluorescent light under humid conditions and showed a possible response, indicating that it could be applied as a humidity sensor.

The Properties of Beam Intensity Scanner(BInS) in IMRT with Phantom for Three Dimensional Dose Verification

  • Young W. Vahc;Park, Kwangyl;Byung Y. Yi;Park, Kyung R.;Lee, Jong Y.;Ohyun Kwon;Park, Kwangyl;Kim, Keun M.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.64-64
    • /
    • 2003
  • Objectives: Patient dose verification is clinically the most important parts in the treatment delivery of radiation therapy. The three dimensional(3D) reconstruction of dose distribution delivered to target volume helps to verify patient dose and determine the physical characteristics of beams used in intensity modulated radiation therapy(IMRT). We present Beam Intensity Scanner(BInS) system for the pre treatment dosimetric verification of two dimensional photon intensity. The BInS is a radiation detector with a custom made software for relative dose conversion of fluorescence signals from scintillator. Methods: This scintillator is fabricated by phosphor Gadolinium Oxysulphide and is used to produce fluorescence from the irradiation of 6MV photons on a Varian Clinac 21EX. The digitized fluoroscopic signals obtained by digital video camera will be processed by our custom made software to reproduce 3D relative dose distribution. For the intensity modulated beam(IMB), the BInS calculates absorbed dose in absolute beam fluence, which are used for the patient dose distribution. Results: Using BInS, we performed various measurements related to IMRT and found the followings: (1) The 3D dose profiles of the IMBs measured by the BInS demonstrate good agreement with radiographic film, pin type ionization chamber and Monte Carlo simulation. (2) The delivered beam intensity is altered by the mechanical and dosimetric properties of the collimating of dynamic and/or static MLC system. This is mostly due to leaf transmission, leaf penumbra, scattered photons from the round edges of leaves, and geometry of leaf. (3) The delivered dose depends on the operational detail of how to make multileaf opening. Conclusions: These phenomena result in a fluence distribution that can be substantially different from the initial and calculative intensity modulation and therefore, should be taken into account by the treatment planing for accurate dose calculations delivered to the target volume in IMRT.

  • PDF

Europium-Enoxacin Complex as Fluorescence Probe for the Determination of Folic Acid in Pharmaceutical and Biological Samples

  • Alam, Al-Mahmnur;Kamruzzaman, Mohammad;Lee, Sang-Hak;Kim, Young-Ho;Min, Kyung
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권9호
    • /
    • pp.3055-3060
    • /
    • 2012
  • A simple, rapid and sensitive spectrofluorometric method was developed for the determination of folic acid (FA), based on its quenching effect on the fluorescence intensity of enoxacin (ENX)-europium ($Eu^{3+}$) complex as a fluorescent probe. Fluorometric interaction between ENX-$Eu^{3+}$ complex and FA was studied using UV-visible and fluorescence spectroscopy. The quenched fluorescence intensity at an emission wavelength of 614 nm was proportional to the concentration of FA. Optimum conditions for the determination of FA were investigated. Under optimal conditions, the reduced fluorescence intensity at 614 nm was responded linearly with the concentration of FA. The linearity was maintained in the range of $1.25{\times}10^{-9}$ to $1.50{\times}10^{-7}$ M (R = 0.9986) with the limit of detection ($3S_b/m$) (where $S_b$ is the standard deviation of blank and m is the slop of linear calibration curve) of $6.94{\times}10^{-10}$ M. The relative standard deviation (RSD) for 9 repeated measurements of $1.0{\times}10^{-9}$ M FA was 1.42%. This method was simple, cost effective, and relatively free of interference from coexisting substances. Successful determinations of FA in pharmaceutical formulation and biological samples with the developed method were demonstrated.