• Title/Summary/Keyword: relative effects

Search Result 4,163, Processing Time 0.028 seconds

EMC/ERH of Rough Rice and Brown Rice (벼 및 현미의 평형함수율/평형상대습도)

  • Choi B. M.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.2 s.109
    • /
    • pp.95-101
    • /
    • 2005
  • Adsorption and desorption experiments were carried out on rough rice and brown rice (Nampyung) at 5, 15, 25, 35, $45^{\circ}C$ for moisture contents between 8.7 and $25\%$ (db). The method employed was to measure the equilibrium relative humidity (ERH) of air in contact with the grain under static conditions, using an electronic hygrometer The effects of temperature and moisture contents were investigated, and the measured values were fitted to the modified Henderson, the modified Chung-Pfost, the modified Halsey and the modified Oswin model. The ERHs of rough rice and brown rice decreased with an decrease in moisture content and temperature, and the effects of temperature was no significant at moisture content of $25\%$ (db). Equilibrium moisture content (EMC) of brown rice was higher than rough rice at same temperature and relative humidity. Desorption EMC is higher than the adsorption, but there is no significant difference between desorption and adsorption EMC in moisture content near $25\%$ (db) at rough rice and near 9, 21 and $25\%$ (db) at brown rice. The modified Oswin model was the best in describing the adsorption EMC and the modified Chung-Pfost model was the best in describing the adsorption ERH of rough rice. The modified Oswin model was the best in describing the adsorption EMC/ERH of brown rice. The modified Chung-Pfost model was the best in describing the desorption EMC/ERH of rough rice and brown rice.

Effects of the Maghemite for Explosive accident Prevention to Liquefied Petroleum Gas (LPG 폭발사고 예방을 위한 Maghemite의 영향)

  • 박영구
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.67-78
    • /
    • 1996
  • Gas sensing element, $\gamma-Fe_2O_3$was synthesized by dehydration, reduction, and oxidation of $$${\gamma}$-FeOOH, which was synthesized with $FeSO_4\;{\cdot}\;7H_2O$ and NaOH. They were produced as a bulk-type, a thick film-type. Then, their responses and mechanisms of response to the gas of liquefied-petroleum were studied. The qualities of gas sensing elements are decided by the structure and the relative surface area. In the process of $\alpha-FeOOH $synthesis, the effects of reaction conditions as the equivalent ratio, on the structure and the relative surface area of gas sensing element were observed. The changes of the structure were measured with XRD, SEM, TG-DTA and BET. The resistance changes of the synthesized gas sensor in the air were measured. The response ratio were also measured for the changes of working temperature and gas concentration. As a result of analysis with XRD, it was confirmed that the the best conditions for the synthesis of $\alpha -FeOOH$ were equivalent ratio 0.65. The thick film-type element of $\gamma-Fe_2O_3$responded more quickly than the bulk-type did. The structure and the relative surface area of the $\alpha-FeOOH $were confirmed as the important factors deciding gas response charcteristics.

  • PDF

Abiotic effects on calling phenology of three frog species in Korea

  • Yoo, Eun-Hwa;Jang, Yi-Kweon
    • Animal cells and systems
    • /
    • v.16 no.3
    • /
    • pp.260-267
    • /
    • 2012
  • Calling behavior is often used to infer breeding patterns in anurans. We studied the seasonal and diel calling activities of anuran species in a wetland in central Korea to determine the calling season and to evaluate the effects of abiotic factors on male calling. Acoustic monitoring was used in which frog calls were recorded for a full day, once a week, throughout an entire year. Using acoustic monitoring, we identified three frog species in the study site. Males of Rana dybowskii called in late winter and early spring; we thus classified this species as a winter/spring caller. The results of binary logistic regression showed that temperature, relative humidity, and 1-day lag rainfall were significant factors for male calling in R. dybowskii. Temperature and relative humidity were important factors for the calling activity of R. nigromaculata, whereas 24-h rainfall and 1-day lag rainfall were not significant. Thus, we determined R. nigromaculata to be a summer caller independent of weather. In Hyla japonica, relative humidity, 24-h rainfall, and 1- day lag rainfall were significant for male calling, suggesting that this species is a summer caller dependent on local rain.

Optimum design of viscous dampers to prevent pounding of adjacent structures

  • Karabork, Turan;Aydin, Ersin
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.437-453
    • /
    • 2019
  • This study investigates a new optimal placement method for viscous dampers between structures in order to prevent pounding of adjacent structures with different dynamic characteristics under earthquake effects. A relative displacement spectrum is developed in two single degree of freedom system to reveal the critical period ratios for the most risky scenario of collision using El Centro earthquake record (NS). Three different types of viscous damper design, which are classical, stair and X-diagonal model, are considered to prevent pounding on two adjacent building models. The objective function is minimized under the upper and lower limits of the damping coefficient of the damper and a target modal damping ratio. A new algorithm including time history analyses and numerical optimization methods is proposed to find the optimal dampers placement. The proposed design method is tested on two 12-storey adjacent building models. The effects of the type of damper placement on structural models, the critical period ratios of adjacent structures, the permissible relative displacement limit, the mode behavior and the upper limit of damper are investigated in detail. The results of the analyzes show that the proposed method can be used as an effective means of finding the optimum amount and location of the dampers and eliminating the risk of pounding.

Chaotic phenomena in the organic solar cell under the impact of small particles

  • Jing, Pan;Zhe, Jia;Guanghua, Zhang
    • Steel and Composite Structures
    • /
    • v.46 no.1
    • /
    • pp.15-31
    • /
    • 2023
  • Organic solar cells utilized natural polymers to convert solar energy to electricity. The demands for green energy production and less disposal of toxic materials make them one of the interesting candidates for replacing conventional solar cells. However, the different aspects of their properties including mechanical strength and stability are not well recognized. Therefore, in the present study, we aim to explore the chaotic responses of these organic solar cells. In doing so, a specific type of organic solar cell constructed from layers of material with different thicknesses is considered to obtain vibrational and chaotic responses under different boundaries and initial conditions. A square plate structure is examined with first-order shear deformation theory to acquire the displacement field in the laminated structure. The bounding between different layers is considered to be perfect with no sliding and separation. On the other hand, nonlocal elasticity theory is engaged in incorporating the structural effects of the organic material into calculations. Hamilton's principle is adopted to obtain governing equations with regard to boundary conditions and mechanical loadings. The extracted equations of motion were solved using the perturbation method and differential quadrature approach. The results demonstrated the significant effect of relative glass layer thickness on the chaotic behavior of the structure with higher relative thickness leading to less chaotic responses. Moreover, a comprehensive parameter study is presented to examine the effects of nonlocality and relative thicknesses on the natural frequency of square organic solar cell structure.

Self-reported Irritation Symptoms among Workers Exposed to Ultra-low Relative Humidity and Thionyl Chloride (극건조 환경에서 염화티오닐 동시 노출자의 자각증상 경험률)

  • Chae, Yoo Mi
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.412-424
    • /
    • 2015
  • Objectives: An ultra dry air environment of nearly ${\leq}2%$ RH is often required in lithium battery factories. The objective of this study is to evaluate the subjective eye, pulmonary, nose, and skin symptoms of workers exposed to ultra-low relative humidity and thionyl chloride. Methods: We recruited 274 workers using a self-reported questionnaire in March 2014. Those who worked in ultra-low relative humidity and with thionyl chloride were identified and their prevalence of symptoms was compared with that of other workers. We excluded white collar workers, researchers and other workers who were exposed to various hazard factors, and finally included 164 workers. Results: There were significant differences in the rate of self-reported eye and skin symptoms between exposure group_1 and exposure group_2. Exposure group_2 experienced more frequent eye, and skin symptoms. Multinomial logistic regression analysis for experience of dry eye symptoms and skin symptoms in exposure group_2 showed that dry eye symptoms (odds ratio [OR], 6.33, 95% confidence interval [CI], 2.19-18.24, p<0.001), and itchiness (OR, 6.45, 95% CI, 1.94-21.43, p<0.01) were the significant variables. The complaints of workers experiencing ultra-low relative humidity and thionyl chloride were high compared with other workers. Conclusion: These findings suggest that exposure to ultra-low relative humidity and thionyl chloride may be associated with more frequent eye and skin symptoms than exposure to ultra-low relative humidity alone. The current precautions to protect workers from the adverse effects of ultra-low relative humidity and thionyl chloride appear to be insufficient, indicating that additional management plans to reduce symptoms should be considered.

Measuring the Relative Risk Aversion Coefficients of Apple Farmers (사과 농가의 상대위험회피계수 추정)

  • Lin, Qing-Long;Yeo, Jun-Ho;Kim, Tae-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1036-1044
    • /
    • 2015
  • This paper estimates the relative risk aversion coefficients of apple farmers. Two hypothetical situations are designed and two-stage questionnaires are conducted for each situation. A utility function that has constant relative risk aversion was used, and it was assumed that the relative risk aversion coefficients follow a log-normal distribution. To reduce the hypothetical bias, the data was collected from repetitive questions. As a result, the mean and standard deviation of the relative risk aversion coefficients of apple farmers was 10.915 and 7.516, respectively. The relative risk aversion coefficients conditional on a survey response in each category were also measured. These findings can be used as parameters to analyze the effects of risk management tools.

Competition for Water in Two Populations of Impatiens pallida (Balsaminaceae) from Contrasting Water Environments (수분환경이 다른 서식지에서 자란 Impatiens pallida 의 두 개체군간 수분에 대한 경쟁)

  • Yang, Hyo-Sik;James B. McGraw
    • The Korean Journal of Ecology
    • /
    • v.19 no.2
    • /
    • pp.165-178
    • /
    • 1996
  • We investigated the role of competition in adaptation to varying water availability levels for two ecotypically-differentiated populations of Impatiens pallida found naturally in low- vs. high-water environments. In a greenhouse experiment, seedlings were grown in pure cultures at two densities (n=1 and 2 plants per pot) and in mixed cultures (n=2) under low-, medium- and high-water treatments. The two populations were shown to be genetically distinct across the range of environmental conditions in the greenhouse experiment, confirming previous findings. The two populations had similar morphological responses to density and water availability in pure cultures and mixtures, but the population from the high-water environment showed a greater growth response to high water availability than did the population from the low-water environment and the difference in growth between the two populations decreased from the high-water to low-water treatment. Relative competitive ability of two populations were compared under three different water treatments and two densities. Differential response to watering treatment and density were not reflected in a difference in relative competitive ability. Relative yield totals were significantly greater than 1 overall. The niche differentiation suggested by RYTs>1 may be responsible for the lack of differential competitive effects observed for populations in the three vatering treatments.

  • PDF

Solvent Effect on $Rb^+$ to $K^+$ Iron Mutation: Monte Carlo Simulation Study

  • Kim, Hak Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.5
    • /
    • pp.503-509
    • /
    • 2000
  • The solvent effects on the relative free energies of solvation and the difference in partition coefficients (log P) for $Rb^+$ to $K^+$ mutation in several solvents have been investigated using Monte Carlo simulation (MCS) of statistical perturbation theory(SPT). In comparing the relative free energies for interconversion of one ion pair, $Rb^+$ to $K^+$, in $H_2O$(TIP4P) in this study with the relative free energies of the computer simulations and the experimental, we found that the figure in this study with the relative free energies of the computert simulations and the experimental, we found that the figure in this study is $-5.00\pm0.11$ kcal/mol and those of the computer simulations are $-5.40\pm1.9$, -5.5, and -5.4 kcal/mol. The experimental is -5.1 kcal/mol. There is good agreement among various studies, taking into account both methods used to obtain the hydration free energies and standard deviations. There is also good agreement between the calculated structural properties of this study and the simulations, ab initio and the experimental results. We have explained the deviation of the relationship between the free energy difference and the Onsager dielectric function of solvents by the electron pair donor properties of the solvents. For the $Rb^+$ and $K^+$ ion pair, the Onsager dielectric function of solvents (or solvent permittivity), donor number of solvent and the differences in solvation dominate the differences in the relative free energies of solvation and partition coefficients.

Analysis of behavioral characteristics of liquefaction of sand through repeated triaxial compression test and numerical analysis

  • Hyeok Seo;Daehyeon Kim
    • Geomechanics and Engineering
    • /
    • v.38 no.2
    • /
    • pp.165-177
    • /
    • 2024
  • Liquefaction phenomenon refers to a phenomenon in which excess pore water pressure occurs when a dynamic load such as an earthquake is rapidly applied to a loose sandy soil ground where the ground is saturated, and the ground loses effective stress and becomes liquid. The laboratory repetition test for liquefaction evaluation can be performed through a repeated triaxial compression test and a repeated shear test. In this regard, this study attempted to evaluate the effects of the relative density of sand on the liquefaction resistance strength according to particle size distribution using repeated triaxial compression tests, and additional experimental verification using numerical analysis was conducted to overcome the limitations of experimental equipment. As a result of the experiment, it was confirmed that the liquefaction resistance strength increased as the relative density increased regardless of the classification of soil, and the liquefaction resistance strength of the SP sample close to SW was quite high. As a result of numerical analysis, it was confirmed that the liquefaction resistance strength increased as the confining pressure increased under the same relative density, and the liquefaction resistance strength did not decrease below a certain limit even though the confining pressure was significantly reduced at a relatively low relative density. This is judged to be due to a change in confining pressure according to the depth of the ground. As a result of analyzing the liquefaction resistance strength according to the frequency range, it was confirmed that there was no significant difference from the laboratory experiment results in the basic range of 0.1 to 1.0 Hz.