• Title/Summary/Keyword: reinforcement behavior

검색결과 1,825건 처리시간 0.029초

전단보강에 따른 일방향 중공슬래브의 휨 성능 평가 (Evaluation on Flexural Performance of One-Way Hollow Slabs according to the Shear Reinforcement)

  • 유유진;석근영;김기철;강주원
    • 한국공간구조학회논문집
    • /
    • 제14권2호
    • /
    • pp.79-86
    • /
    • 2014
  • The purpose of this study is intended to determine the validity of shear reinforcement by evaluating flexural performance in the hollow slab. The hollow slab is relatively light and second moment of inertia is large. Due to these characteristics, it can be used to slab system efficiently. Therefore the prediction of the structural behaviors is very important because of decrease of shear and flexural strength which is caused by hollow section of slab interior. In this study, the flexural test were performed to analyze the flexural capacity of the hollow slab w/ or w/o shear reinforcement. A total of six full scale specimens were tested. These specimens have three cases of reinforcing bar ratio, 0.009, 0.018 and 0.024. To verify the flexural behavior such as ultimate load, load-deflection and crack pattern, the flexural experiment were tested by using loading frame. Experimental results have shown that the flexural behavior are depend on the reinforcing bar ratio. Also the hollow slab with shear reinforcement have shown flexural behavior. Therefore, it is appropriate that the hollow slab is reinforced by shear reinforcement to improve the flexural performance of the hollow slab.

The effect of tensile reinforcement on the behavior of CFRP strengthened reinforced concrete beams: An experimental and analytical study

  • Javad Sabzi;M. Reza Esfahani;Togay Ozbakkaloglu;Ahmadreza Ramezani
    • Steel and Composite Structures
    • /
    • 제46권1호
    • /
    • pp.115-132
    • /
    • 2023
  • The present study experimentally and analytically investigates the effect of tensile reinforcement ratio and arrangement on the behavior of FRP strengthened reinforced concrete (RC) beams. The experimental part of the program was comprised of 8 RC beams that were tested under four-point bending. Results have shown that by keeping the total cross-section area of tensile reinforcing bars constant, in specimens with a low reinforcement ratio, increasing the number and decreasing the diameter of bars in the section lead to 21% and 29% increase in the load-carrying capacity of specimens made with normal and high compressive strength, respectively. In specimens with high reinforcement ratio, a different behavior was observed. Furthermore, the accuracy of the existing code provisions and analytical models in predicting the load-carrying capacity of the FRP strengthened beams failed by premature debonding mode were evaluated. Herein, a model is proposed which considers the tensile reinforcement ratio (as opposed to code provisions) to achieve more accurate results for calculating the load carrying capacity of FRP strengthened RC beams.

Flexural behavior of titanium bar reinforced granite with various reinforcement ratio

  • Lim, Woo-Young
    • Structural Engineering and Mechanics
    • /
    • 제74권6호
    • /
    • pp.757-769
    • /
    • 2020
  • Granite is commonly used in the construction of the ancient stone pagodas of Korea. The material has excellent weathering resistance and durability, as well as high compressive strength. Most of the stone-made state-designated architectural heritage of Korea is made of granite. Therefore, the understanding of the structural feasibility of stone-made architectural heritage is crucial. Even though, until now, experimental studies for the reinforced stone have been rarely performed. This study intends to suggest a new methodology for the reinforcement of granite using a threaded titanium bar. Through the experimental study, the flexural behavior of the reinforced granite depending on the reinforcement ratio is investigated. Based on the test results, a moment-displacement relationship for the design of reinforced granite is suggested.

탄소섬유쉬트로 보강된 RC부재의 철근량에 따른 휨 보강성능 (Effect of Steel Reinforcement Ratio on the Flexural Behavior of RC Beams Strengthened with CFRP Sheets)

  • 유영찬;최기선;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.177-180
    • /
    • 2006
  • Experimental study has been performed in order to evaluate the effects of steel reinforcement ratio on the flexural behavior of RC beams strengthened with CFRP sheets. The steel reinforcement ratio of $0.78%({\rho}_s/{\rho}_b=24%)$ is selected to have balance failure when control RC beams were strengthened with 1 ply CFRP sheet. Total 6 half-scale specimens were manufactured including each unstrengthened specimens, which have 3 different reinforcement ratios. The specimens strengthened with CFRP sheet consist of under- or over-reinforced beams for the balanced failure condition. Moreover, the behavior of un strengthened or strengthened beams were compared to evaluate flexural performance. The results of this study show that the over-reinforced specimens were failed by concrete crushing prior to CFRP sheet failure by debonding or rupture. On the contrary, the under-reinforced specimen were failed by rupture of CFRP sheet.

  • PDF

The effect of fiber reinforcement on behavior of Concrete-Filled Steel Tube Section (CFST) under transverse impact: Experimentally and numerically

  • Yaman, Zeynep
    • Structural Engineering and Mechanics
    • /
    • 제82권2호
    • /
    • pp.173-189
    • /
    • 2022
  • This study presents an experimental and numerically study about the effects of fiber reinforcement ratio on the behavior of concrete-filled steel tubes (CFST) under dynamic impact loading. In literature have examined the behavior of GFRP and FRP wrapped strengthened CFST elements impact loads. However, since the direction of potential impact force isn't too exact, there is always the probability of not being matched the impact force of the area where the reinforced. Therefore, instead of the fiber textile wrapping method which strengthens only a particular area of CFST element, we used fiber-added concrete-filled elements which allow strengthening the whole element. Thus, the effect of fiber-addition in concrete on the behavior of CFST elements under impact loads was examined. To do so, six simply supported CFST beams were constructed with none fiber, 2% fiber and 10% fiber reinforcement ratio on the concrete part of the CFST beam. CFST beams were examined under two different impact loads (75 kg and 225 kg). The impactors hit the beam from a 2000 mm free fall during the experimental study. Numerical models of the specimens were created using ABAQUS finite element software and validated with experimental data. The obtained results such as; mid-span displacement, acceleration, failure modes and energies from experimental and numerical studies were compared and discussed. Furthermore, the Von Misses stress distribution of the CFST beams with different ratio of fiber reinforcements were investigated numerically. To sum up, there is an optimum amount limit of the fiber reinforcement on CFST beams. Up to this limit, the fiber reinforcement increases the structural performances of the beam, beyond that limit the fiber reinforcement decreases the performances of the CFST beam under transverse impact loadings.

밴드형 전단보강근으로 보강된 무량판 슬래브 내부접합부의 구조 거동 평가 (Evaluation of Structural Performance of Flat Plate-Column Interior Connections with Folded Bend Shear Reinforcement)

  • 이범식;박성식;박지영;방종대;전명훈;조건희
    • 토지주택연구
    • /
    • 제4권4호
    • /
    • pp.371-382
    • /
    • 2013
  • 불균형 모멘트가 작용하는 무량판 슬래브 내부접합부를 대상으로 폐쇄형 전단보강근으로 보강한 1개 실험체와 밴드형 전단보강근으로 전단보강한 2개의 실험체를 제작하여 구조성능을 평가하였다. 구조성능평가 결과, 구조설계기준(KBC 2009)으로 평가한 불균형모멘트는 실험결과의 95%로 매우 잘 일치하나, 개정 구조설계기준(KCI 2012)으로 산정한 불균형모멘트는 실험결과의 약 60%에 불과하여, 내부접합부의 불균형모멘트를 과대평가하는 것으로 나타났다. 밴드형 전단보강근은 기존 전단보강근과 비교하여 유사한 구조성능을 가지며, 시공성이 우수한 것으로 나타나 중진지역의 무량판구조물 설계 시 적용할 수 있는 것으로 평가되었다.

전단보강근비에 따른 고강도 철근콘크리트 내력벽의 이력특성 (Effects of Web Reinforcement Amount on Hysteretic Behavior of High Strength Reinforced Concrete Structural Walls)

  • 최근도;정학영;윤현도;최장식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.85-90
    • /
    • 1994
  • Three high strength reinforced concrete structural walls were tested under the combined action of a constant axial and a horizontal cycle load. The aim of the tests has been to investigate the effects of the web horizontal reinforcement on hysteretic behavior of wall. The results have helped to identify the causes of wall failure and have demonstrated the web horizontal reinforcement does not appear have a significant effect on shear capacity, stiffness and energy dissipation but have a significant effect on the failure mode of the walls.

  • PDF

지하 철근 콘크리트 박스 구조물의 내진해석방법 및 철근 배근 상세에 관한 연구 (The Study of detailng for concrete reinforcement and Seismic Analysis Method for Underground Reinforced Concrete Box Structures)

  • 이명수;한상철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1215-1222
    • /
    • 2005
  • The object of this thesis is an study on detailing for concrete reinforcement and analytical study for seismic behavior of underground reinforced concrete box structures using the established seismic analytical method. Using the established seismic analytical method that has been presented in various documents seismic behavior of buried reinforce concrete box structures is compared. From the comparsion, it is shown that feasibility and detailing detailng for concrete reinforcement and seismic method for seismic analysis of buried reinforced concrete box structures.

  • PDF

Effect of spiral reinforcement on flexural-shear-torsional seismic behavior of reinforced concrete circular bridge columns

  • Belarbi, Abdeldjelil;Prakash, Suriya;You, Young-Min
    • Structural Engineering and Mechanics
    • /
    • 제33권2호
    • /
    • pp.137-158
    • /
    • 2009
  • This paper investigates the behavior of reinforced concrete (RC) circular columns under combined loading including torsion. The main variables considered in this study are the ratio of torsional moment to bending moment (T/M) and the level of detailing for moderate and high seismicity (low and high transverse reinforcement/spiral ratio). This paper presents the results of tests on seven columns subjected to cyclic bending and shear, cyclic torsion, and various levels of combined cyclic bending, shear, and torsion. Columns under combined loading were tested at T/M ratios of 0.2 and 0.4. These columns were reinforced with two spiral reinforcement ratios of 0.73% and 1.32%. Similarly, the columns subjected to pure torsion were tested with two spiral reinforcement ratios of 0.73% and 1.32%. This study examined the significance of proper detailing, and spiral reinforcement ratio and its effect on the torsional resistance under combined loading. The test results demonstrate that both the flexural and torsional capacities are decreased due to the effect of combined loading. Furthermore, they show a significant change in the failure mode and deformation characteristics depending on the spiral reinforcement ratio. The increase in spiral reinforcement ratio also led to significant improvement in strength and ductility.

묶음 대각철근을 적용한 철근콘크리트 연결보의 이력거동 평가 (Cyclic Behavior of Reinforced Concrete Coupling Beams with Bundled Diagonal Reinforcement)

  • 한상환;권현욱;신명수;이기학
    • 한국지진공학회논문집
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2014
  • Diagonal reinforced coupling beam of coupled shear walls can provide sufficient strength and stiffness to resist lateral force. However, the reinforcement details for coupling beams required by ACI 318 (2011) are difficult to construct because of the reinforcement congestion and confined interior area. This study presents experimental results about the seismic performance of coupling beams having bundled diagonal reinforcement to improve the workability. Experiments were conducted using half scaled precast coupling beams having an aspect ratio of 2.0. It was observed that the bundled diagonal reinforced coupling beams can develop seismic performance similar to the coupling beams with requirement details specified in ACI 318 (2011).