• 제목/요약/키워드: refuge facility

검색결과 14건 처리시간 0.025초

초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구 (A Study on the Improvement of the Refuge safety area in High-rise Buildings Type)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.

비상시 대피시설로 전환가능한 주민시설 디자인에 관한 연구 (A Study on the Community Facility Design Convertible to Refuge in case of Emergency)

  • 김희교
    • 한국산학기술학회논문지
    • /
    • 제15권4호
    • /
    • pp.2503-2510
    • /
    • 2014
  • 본 연구는 평상시에는 주민시설의 기능을 수행하며, 재난의 발생 시에 주민의 대피시설로 기능전환이 가능한 주민시설의 디자인 방법을 모색하는 것에 목표를 둔다. 이를 위하여, (1)재난 및 대피공간관련 용어의 정의, (2)관련 법령 및 기준의 현황, (3)기존의 건립된 주민시설(체육센터, 문화센터)의 수용기능 현황 및 특성 등을 연구하였으며, 기능전환형 주민시설의 디자인을 위한 (1)공간구성의 요구사항, (2)미래형 주민시설을 디자인하기 위한 방안 등에 대해서 문헌연구를 진행하였다. 시 군 구의 주민시설의 계획단계에서 설계지침의 작성 시, (1)대피관련 기능의 수직적 집적화, (2)프라이버시를 고려한 공간구획 및 건축적 장치, (3)화장실, 샤워시설 등의 배치와 출입구의 적절한 복수계획 및 배치, (4)단위공간의 적정규모 등이 기능전환형 주민시설의 디자인에서 중요한 요소로 파악되었다. 향후 기능전환형 주민시설 디자인의 가이드라인이 수립되어 이재민의 발생이라는 부득이한 상황이 발생했을 때 주민의 심리적 불안감을 최소화 하면서 대피공간의 기능을 수행한다면 바람직하다고 생각된다.

관람객 행동 특성에 따른 멀티플렉스 피난시설 개선방안 연구 (A Study on the multiplex refuge facility according to visiter's behavior characteristics)

  • 조영준;김택우;김영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.187-190
    • /
    • 2005
  • By the rapid technological advance and social needs, demand of Multi Function Facility is on the increase. The multiplex is an alternative of them. In case of fire, special function of facility nay result in terrible accident. Therefore, literature and regulations survey on the multiplex were enforced, Multiplex facilities in Daejeon City were surveyed, and reformation of regulation and structural system were suggested in this study.

  • PDF

비상시 청각형 유도시설의 유도성능 평가에 관한 연구 (A Study on the evaluation of the auditory guide facility under emergency situation)

  • 나욱정;전규엽;홍원화
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1205-1208
    • /
    • 2006
  • Today, our city structure is being complicated from the development of industry. Invisible losses, life and fortune loss caused by arson is embossed in our society. The preparation of counter plan about increasing factors of fire damage is not easy. With respect to mankind life, however, it is very important. Therefore, the focus of this research examine refuge degree in each smoke density level when a fire break out in the space. I evaluated auditory guide facility thorough real scale test. In this thesis, I will propose the efficient refuge deriving facilities.

  • PDF

의료시설 내 치유환경 조성을 위한 자연요소 도입에 관한 연구 - 서울대학교병원 사례분석을 중심으로 - (A Study on the Healing Environment with Natural Elements in Healthcare Facility - Focused on the Case Study of Seoul National University Hospital -)

  • 정태종
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.61-68
    • /
    • 2019
  • The analysis of outdoor and indoor spatial composition with natural elements is required for the creation of healing environment in healthcare facility to provide basic data for the planning of hospital architecture. Literature review of healing environment and investigation on characteristics of spatial composition in architectural works and healthcare facilities have been conducted. The spatial composition of outdoor space for refuge and prospect from indoor space of Seoul National University Hospital have been analyzed. The result of this research can be summarized as followed. First of all, the main natural elements for healing environment are consisted with refuge in outdoor space and prospect from indoor space. The second one is that natural elements in Seoul National University Hospital are located in central, posterior, and lateral area of main hospital and connectivity, integration, and ERAM(3) which the characteristics of outdoor spatial composition with space syntax are focused on the museum of medicine and landscape area in the center of hospital. The third one is that the outdoor refuge and prospect from indoor space in Seoul National University Hospital can be replaced with cultural heritage like the site of Kyungmogungji and Changgyeonggung palace in and next to the hospital. In addition to the outdoor and indoor spatial composition, it is necessary to analyze the relationship between elements to develop the healing environment of hospital architecture.

대형할인점의 피난대책 및 소방시설 개선방안에 관한 연구 (A Study on the Escape Measures and Fire Protection System Improvement in Discount Stores)

  • 홍성우;이영재
    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.20-27
    • /
    • 2002
  • 본 연구는 현재 급속히 확산되고 있는 대형 할인점의 피난대책 및 소방시설 설치기준에 관한 개선방안을 제시하기 위한 것으로 주요 내용은 다음과 같다. -대형 할인매장의 피난대책. -매장의 피난시설 설치의 문제점 및 대책. -매장의 방화구획 설치의 문제점 및 대책. -매장의 옥내소화전 설치의 문제점 및 대책. 연구결과 건축계획시 면적기준에 의해 설치되는 피난계단의 경우 상주인원수에 의해 수량, 설치위치, 규격 등이 결정되어야 할 것이며, 매장 부분의 방화구획 또한 시설물 설치로 인한 장애 및 피난로 확보 차원에서 매장부분에 한하여 설치를 완화하는 대신 스프링클러 설치 기준을 강화하여야 할 것이며, 스프링클러 설치시 자진하여 옥내소화전을 추가 설치하는 경우 소화전은 상품진열 등으로 인하여 사용이 불가능한 부분이 발생하므로 매장부분에 설치되는 옥내소화전은 설치반경을 완화하여 실질적인 소화시설 사용이 가능하도록 하여야 할 것이다.

철도 시설 및 차량 분야 사고 발생에 따른 비상대응 설비 환경 분석 연구 (A Study on emergency equipments for accidents of rail infrastructure and rolling-stock)

  • 양도철;서영민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1817-1823
    • /
    • 2007
  • In this study, we have studied rail infrastructure related to emergency action to manage the risk when emergency caused by faults of facility or rail vehicle during operation happens. Especially we have compared the effect of emergency action with examining the structure of vehicle, tunnel, bridge and access road, etc which are related to emergency action. Also, we have tried to analyze effects of radio and communication equipment, lifesaving and refuge which could be used for rolling stock, station, control room, tunnel, bridge and etc, and we have presented the way of reporting the emergency to the train driver or crew, control room, outside networks which could be used by passengers in vehicle, station, railroad line. Based on these, we have analyzed the conduct of emergency action in length of time when emergency happens in railway and high-speed railway, and studied the method of which passengers could be guided safely and escape from the scene of the accident.

  • PDF

지하연계복합건축물의 피난 안전구역 면적 산정 (A Capacity of Refuge area in Multiple Occupancy Building with Underground Facility)

  • 김종성;김운형;이용재
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.272-276
    • /
    • 2011
  • 최근 발생한 부산 해운대 화재 이후 피난 활동이 제한적인 고층 건축물의 화재 안전에 대한 관심이 증대되고 있다. 그러나 현행 규정은 50층 이상의 초고층 건축물을 대상으로 하고 있으며 상대적으로 준 초고층 건축물에 대한 제도적 기반과 연구가 미비한 실정이다. 따라서 본 연구에서는 지하연계복합건축물에 관한 피난 안전구역면적 산정 기준에 대한 적용성을 분석하고자 국외의 관련 기준과 비교 분석하였다. 그 결과, 수용 인원에 관한 기준은 홍콩, 한국, 싱가포르, 중국 순으로 강화 적용하고 있으며 피난안전구역의 면적은 싱가포르의 경우 전체 수용 인원의 50% 이상과 1명당 $0.3m^2$을 전제로 하는 피난안전구역의 면적 기준이 국내의 각 층별 1/10의 면적의 합과 동일한 것으로 분석되었다.

  • PDF

서울시 지하공간 재난관리 및 재난의료 개선방안 (Disaster Management and Disaster Medical Improvement in Underground Space)

  • 배윤신;박지혜
    • 한국재난정보학회 논문집
    • /
    • 제7권2호
    • /
    • pp.110-122
    • /
    • 2011
  • 본 연구에서는 서울시 지하공간에서 화재발생시 재난관리 및 재난의료 개선방안을 지하상가를 중심으로 기술하였다. 먼저 지하공간에서의 법령 및 제도를 건축법관련, 안전관련, 소방관련, 피난관련으로 고찰해 보았다. 서울시 지하상가의 분류는 공간 및 형태적 유형에 따라 나눌 수 있으며, 유형별 형태에 따라 관리주체가 다르게 나타난다. 이러한 개별관리체계로 인하여 화재 및 재난발생 시 현장의 통합지휘체계와 현장 응급구조에 문제가 발생할 우려가 있어 향후 통합관리를 위한 대책 및 시설관리주체의 개선이 필요하다. 재해 발생 시 이송이 실제 현장에서 이루어지려면 의료진과 응급구조사가 존재하고, 현장지휘본부와의 협조가 원활해야 가능하기 때문에 평소에 재해정보와 응급의료정보가 실시간으로 파악되어야 한다. 따라서 수용의료기관 분포와 진료능력등을 고려하여 재해 발생 시 효율적인 대처방안 수립이 필요하다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.